Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.1 LAccepted-Finance | L1 | Accepted-Finance found in order | |
| 2 | L2₹6.2 L+₹15,738 (2.58%)Accepted-Finance 213 BAHARTI NAGAR SUBASH NAGAR JAMMU JAMMU JAMMU JAMMU KASHMIR 180007 | JAMMU | JAMMU AND KASHMIR | 180007 | L2 | Accepted-Finance found in order | |
| 3 | L3₹8.4 L+₹2.3 L (37.1%)Accepted-Finance H NO 3 11 REHARI COLONY ROAD JAMMU UT OF J K 180005 | JAMMU | JAMMU | JAMMU AND KASHMIR | 180005 | L3 | Accepted-Finance found in order | |
| 4 | Rejected-Technical 1ST FLOOR SHOP NO 11 MORI GATE RAJINDER MARKET NEW DELHI DELHI 110006 INDIA | NORTH | DELHI | 110006 | - | Rejected-Technical Document Not Found in Order Because Neither EMD uploded online on portal nor physically submitted to this HQ upto 09/06/2022 till 1030 Hrs as mentioned in NIT |
Tender Value
₹7.7 L
EMD Value
₹15,375
Closing Date
8 Jun 2022, 10:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Engineer (Elect), SHQ BSF Jammu
SHQ BSF Jammu
CO BOP Buildings at BOP Makwal Fwd of 127 Bn BSF Now 16 BN BSF under SHQ BSF Jammu SH SOs Room, Garrage with POL store, Dog Kennel, Sentry Post SH Panel Installation and service connection
2022_BSF_691315_1
07/EE(E)/FTR-Jammu/2022-23
Open Tender
Electrical Works
Item Rate
BOP Makwal In AOR of 16 BN BSF under SHQ BSF Jammu
Please Refer Tender Documents
7 documents required · 7 mandatory
₹0
₹15,375
Yes
22 Jun 2022
27 May 2022
9 Jun 2022
27 May 2022
8 Jun 2022
27 May 2022
27 May 2022 - 8 Jun 2022
90 days
Amount
Supplying and Laying of one number Aluminum conductor PVC insulated and PVC sheathed armored UG cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/DWC HDPE pipe as required. at a depth upto 75 cm., as required.
2 x 25 Sqmm
3.5 x 35 Sqmm
3.5 x 95 Sqmm
3.5 x 185 Sqmm
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required
63 mm dia (OD-63 mm & ID-51 mm nominal)
90 mm dia (OD-90 mm & ID-76 mm nominal)
120 mm dia (OD-120 mm & ID-103 mm nominal)
Supplying and making end termination with brass compression gland and aluminium lugs for following sizes of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
2 x 25 Sqmm (28 mm)
3.5 x 35 Sqmm (22 mm)
3.5 x 95 Sqmm (45 mm)
3.5 x 185 Sqmm (57 mm)
SITC of cubical canopy type out door hut type Junction box having size 450 mm (L) x 300mm (D) x 450mm (H) fabricated with CRCA sheet 2 mm thick mounted on 04 Nos 35mm x 35mm x 5mm thick angle iron frame, erected in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) foundation including excavation & refilling,hinged front & back doors with locking arrangements,,cable tray with provision of fixing of glands at hte bottom,antirust design, air ventilation grooves, water drop proofing arrangement ,insluators,earthing studs,nuts bolts etc.as required including connections,painting with primer & finish paint with synthetic enamel paint 04 nos aluminium bus bar strip suitable for 100 A,415 V capacity with suitable insulated support for AL bus bar complete as required.
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Supplying and laying following size PVC pipe (in Black/Grey color) ISI marked complete etc. complete with fitting and cutting, jointing etc. on the existing culvert/fixing on wall with the help of C-clamp, fastner, bends etc. complete as required. (for culvert)
75 mm dia. Pipe for 3.5 x 25 and 3.5 x 35 sq.mm size cable
90 mm dia. Pipe for 3.5x95 sq.mm size cable
110 mm dia. Pipe for 3.5x185 sq.mm size cable
Supplying, installation, testing and commissioning of outdoor hut type feeder pillar suitable for 415 V, 3 phase, 4 wire, 50 Hz AC supply system fabricated in compartmentalized design from 2 mm thick CRCA sheet, double door type with inbuilt locking arrangement, 3 mm pasivated gland plate, depth not less than 300 mm and all connection (incoming and outcoming) will be taken out in cable alley. The panel shall be cleaning, processing and finishing with 7 tank process for powder coating in approved shade and supplied with suitable pedestal of 50mm x 50 mm x 6 mm angle iron frame with 600 mm long legs, 200 Amp 4 nos high conductivity aluminium bus bar with DMC/SMC support, earth bus as the same size as the phase bus running across the length of the panel, solid connection from main bus bar to switchgear, control wiring with 1.5 sqmm FRLSH insulated multi stranded copper conductor with cable alley, including providing and fixing following switchgear, fixing LED phase indicator and following accessories etc complete as required. The panel shall be mounted on suitable cement concrete foundation 30 cm below the ground level and 30 cm above the ground level. The panel should not less than 1200 mm x 1200 mm x 300 mm as CPRI approved. Note:- (i) Panel size indicated is nominal. The actual size shall be as per the drawing approved by the Department. Incomer i) MCCB 04 Pole 200 Amp 38-45 Ka , L frame, adjustable thermal and adjustable magnetic setting, Havells/C&S .02 nos with spreader terminals (Both these MCCBs are to be interlocked in such a way that only 01 shall ON at at time.) ii) On load change over 4 pole 200 Amp open execution type for incoming from both DG sets 1 No - (Make L & T) iii) 3 Phase Digital Ammeter CL-1.0 - 1 No. (Make :- L & T) iv) 3 PhaseDigital Voltmeter CL-1.0 - 1 No. (Make :- L & T) v) CTs 200/5A, CL-1, 15 VA, Cast Resin for metering - 3 Nos. (Make:- AE ) vi) LED Phase Indicating Lamps - 1 Set of 03 Nos. Outgoings i) MCCB 04 Pole 125 Amp Havells/C&S Fixed type 26-30 Ka breaking cap. = 02 nos with spreader terminals ii) MCCB 02 Pole 63 Amp Havells/C&S/L&T/HPL Fixed type 15-20 Ka breaking cap. 02 nos with spreader terminals
Supplying, installation, testing and commissioning of outdoor hut type feeder pillar suitable for 415 V, 3 phase, 4 wire, 50 Hz AC supply system fabricated in compartmentalized design from 2 mm thick CRCA sheet, double door type with inbuilt locking arrangement, 3 mm pasivated gland plate, depth not less than 300 mm and all connection (incoming and outcoming) will be taken out in cable alley. The panel shall be cleaning, processing and finishing with 7 tank process for powder coating in approved shade and supplied with suitable pedestal of 50mm x 50 mm x 6 mm angle iron frame with 600 mm long legs, 200 Amp 4 nos high conductivity aluminium bus bar with DMC/SMC support, earth bus as the same size as the phase bus running across the length of the panel, solid connection from main bus bar to switchgear, control wiring with 1.5 sqmm FRLSH insulated multi stranded copper conductor with cable alley, including providing and fixing following switchgear, fixing LED phase indicator and following accessories etc complete as required. The panel shall be mounted on suitable cement concrete foundation 30 cm below the ground level and 30 cm above the ground level. The panel should not less than 1200 mm x 1200 mm x 300 mm as CPRI approved. Note:- (i) Panel size indicated is nominal. The actual size shall be as per the drawing approved by the Department. Incomer i) MCCB 04 Pole 125 Amp 26-30 Ka , L frame, adjustable thermal and adjustable magnetic setting, Havells/C&S = 02 nos with spreader terminals ii) 3 Phase Digital Ammeter CL-1.0 - 1 No. (Make :- L & T) iii) 3 PhaseDigital Voltmeter CL-1.0 - 1 No. (Make :- L & T) iv) LED Phase Indicating Lamps - 1 Set of 03 Nos. Outgoings i) MCCB 04 Pole 100 Amp Havells/C&S Fixed type 26-30 Ka breaking cap. = 3 nos with spreader terminals ii) 40 Amp SPN MCB - 05 Nos (For Distribution to BOP Elements)
M/S ROYAL ENGINEERS AND CONTRACTORS
M/S AMAR PAL SINGH
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .