| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAccepted-AOC INSIDE KL PARK W NO 37 IN MOGA CITY | L1 | Accepted-AOC L1 | |
| 2 | L2₹14.6 L+₹13,677.50 (0.95%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹14.8 L+₹42,437.50 (2.94%)Rejected-AOC VILLAGE KHARI KALAN PO CHOLANG DISTT JALANDHAR | JALANDHAR | L3 | Rejected-AOC L3 | |
| 4 | L4₹14.9 L+₹44,956 (3.12%)Rejected-AOC HOUSE NO 3 RAJA GARDEN EXT KAPURTHALA ROAD JALANDHAR | L4 | Rejected-AOC L4 | |
| 5 | Rejected-Technical VILL DAKALA DIST PATIALA | - | Rejected-Technical Not Eligible |
Tender Value
₹14.9 L
EMD Value
₹30,000
Closing Date
11 Oct 2023, 11:00 amClosed
Er. Nitin Kalia
Executive Engineer Water Supply and Sanitation Division No 2 Jalandhar
Prov and Installing straight tubewell of 200mm id 160 mtr deep with 15 mtr Stainless strainer with Reverse Rotary Rig Pumping Machinery Disinfections Unit Rising Main 10kgcm2 All Civil Works and Carriage Sheet as per site complete in all respects
2023_WSS_109636_1
WS SCHEME DAROLI KHURD BLOCK ADAMPUR DISTT JAL
Open Tender
Civil Works - Water Works
Item Rate
60 days
Jalandhar
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
₹30,000
8 Dec 2023
21 Sept 2023
11 Oct 2023
21 Sept 2023
11 Oct 2023
21 Sept 2023
Amount
Tubewell of Reverse Rotary Rig Drilling of 500mm dia bore with Reverse Rotary Rig in all kinds of soil including the cost of consumable stores, fuel oil and transportation of Rig to the site. complete in all respect.
Drilling of 500mm dia bore with Reverse Rotary Rig beyond 150 m depth BGL upto 300 mtr
Supplying, lowering of MS Pipe as per IS:4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore.
200mm nominal diameter (weight 33.6 kg per meters) 6.40 mm thickness
Supplying, Fixing & lowering of Stainless Steel Cage type wire wound screen as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding lectrode.to lower the strainer into tubewell bore
200mm Steel Strainer (slot size 0.75mm) 6.30 mm thickness
Supplying, Fixing & lowering of Stainless Steel Socket as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode.to lower the strainer into tubewell bore complete in all respect.
200mm internal diameter
Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect.
200mm Internal diameter
Supplying & fixing of M.S Clamp of size 150mm×12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect.
Supplying at site wooden Box of suitable size with Lid & locking arrangement for preserving strata sample collected from the bore.
Supplying & fixing of bail plug of M.S pipe complete with intverted U-Hook attached to the bottom plug complete in all respect.
200mm internal diameter (6.40 mm thickness)
Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect.
200mm internal diameter
Development and Stabilizing of the tubwell with air compressor of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Capacity of Air compressor 300 cfm at 250 PSI.
Development of stabilizing of the tubewell with submersible pump of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Collection of water sample from different strata and testing of sample from approved laboratory (Physical & chemical Analysis)
Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide etc.)
Making electric Logging of borehole with electronic well logger including cost of equipment at site etc. complete in all respect
Supplying at site of gravel of 1/16" to 1/8" sizes including pouring and packing in the annular space between the pipes assembly and the bore. The gravel should be free from dust, dirt, or the vegetable manner as per IS 4097/1967 with latest amendments (to be paid as per actual length of pipe.
Supplying and fixing mild steel cantering guides made out of 32mm x 6mm thick M.S. bar complete in all respects.
Provision for Sanitary Clay Seal (As per BIS Code IS 2800:2019) Including sterilization of Tubewell.
Rising Main Providing, Stringing out PVC pipes 10 kgf/ Providing, laying, fixing & jointing of PVC pipe as per ISI-4985 (ISI Marked with Prior approval of Engineer in- Charge ) along the tranches and laying the same in tranches to correct alignment and gradients , cutting, jointing & testing complete as per specifications. for more than 3 mtr. Street width Complete in all respect. (Manually Excavation including specials (10kgf/ cm2) Pressure
110 mm o/d PVC Pipe
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge) A Class PN-1 as per ISI
100mm i/d sluice value flanged
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department size 0.6m x 0.60m.
New Pumping Machinery Providing & installing, testing & commissioning of 1 no electrically driven Submersible Pump set capable of delivering 313 LPM against a head of 116 mtr along with electric panel board consisting of electrical appliances such as automatic Star Delta Push Button or oil imeersed starter,Main Switch,VM,AMpere Meter,ELCB,Shunt capacitor.Single phase,preventer,Indicating lamps,Kit-Kat etc. including GI column Pipe of IS 1239-2004 medium class size 80mm and Length 71mtr.(in 3mtr lengths each with flanges,screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable of 142 Mtr. Length and4.00mm2 size as per IS694-1990 reaffirmed 2000 complete in all respects
Motor 313 LPM, Head 116 Mtr.
Panel Board
Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS: 694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge. Cable (Size/Cost) 4.00mm2
Providing and laying, jointing, fixing, testing ISI Market G.I Pipe (as per IS 1239) B-Class, including cost of Specials such as tees, bends, sockets elbow etc. Cutting, threading and testing in trenches in the ground complete. Column Pipe (G.I)( Size/Length) (80mm i/d)
D.I FITTING INSIDE PUMP CHAMBER Providing and installing 100mm dia delivery main (From Tube well to Duck Foot bend including cost of D.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as D.I Bends, Tail Piece Tees etc.. inside the pump chamber as per standard design complete in all respects.
CHLORINATION & DISINFECTION Prov. & Fixing Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6 Liters of Bleaching Powder solution/ Sodium Hypo solution per hour under maximum delivery pressure upto 7 Kg.cm2, and suction lift not less than 1.5 m, as per DWSS standard specifications.
Small Cabinet type pump chamber for panel and chlorination Installation for out side Tubewell
Construction of Gravel Pit outside the Pump Chamber. (0.90m Dia.) as per standard design & drawings of public health department.
Tee Connection Existing PVC to New PVC Pipe
amanbir singh govt. contractor tarntaran
GURJIT SINGH CONTRACTOR
Suresh Kumar Jain
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .