Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 CrAdmitted-Finance FLAT NO 6C KING SAPPHIRE MORABADI HATMA PS LALPUR RANCHI JHARKHAND 834008 | RANCHI | RANCHI | JHARKHAND | 834008 | ₹4.3 Cr | L1 | Admitted-Finance |
| 2 | L2₹4.3 Cr+₹8.5 L (2.00%)Admitted-Finance | ₹4.3 Cr+₹8.5 L (2.00%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SATYA SHREE SAI CONSTRUCTION COMPANY L2 | ARYAN CONSTRUCTION L1 |
|---|---|---|---|---|---|
| 1.00Model-01 :- 05 Nos Scheme and 54 Nos H.C. | |||||
| 2.00(A) Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump (Model-01) | |||||
| 3.00Designing, Supplying, Installation, Testing & Commissioning with all tools & Parts of following Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump Suitable for minimum 125mm x 115mm bore well as per MNRE Guideline with following specifications & accessories. | |||||
| 4.00SPV arrays contains specified No of same capacity type & specification modules connected to series or parallel to obtained the required voltage & current the power output of individual PV modules should be minimum 200 watt peak. | |||||
| 5.00i) The SPV modules should be as per IEC-61215 and IEC 61730 part 1.0) | |||||
| 6.00ii) All external parts of motor pump used in submersible pump which are in contact of water is stainless steel grade 303 or higher as required. | |||||
| 7.00iii) The PV modules should be mounted on metallic structure of adequate strength and appropriate design which can withstand load of modules & High wind pressure up to 200Km/h. | |||||
| 8.00iv) The module mounting structure should be hot dip galvanized according to IS 4759. | |||||
| 9.00v) To enhance the performance of SPV water pumping system & arrangement for seasonal tilt angle Adjustment should be provided | |||||
| 10.00vi) Necessary arrangement should be provided in controller automatic start-run-stop through out the day with water level detection system. (As per MNRE Specification) | |||||
Tender Value
₹4.1 Cr
EMD Value
₹4.1 L
Closing Date
22 Jan 2022, 5:00 pmClosed
EXECUTIVE ENGINEER
Drinking Water and Sanitation Division Garhwa
Construction of Kalyanpur Group of SVS in Garhwa Block Rural Pipe Water Supply Scheme through with coverage by Tap water Facility under (JJM) Garhwa District (1st Call) (Group No. 55) 39 Nos. Scheme
2022_DWSD_55257_1
DWSD/GAR/SVS(JJM)04/2021-22
Open Tender
Civil Works
Item Wise
365 days
E.E. D.W.and S. Division Garhwa
As per mentioned in SBD
3 documents required · 3 mandatory
₹10,000
E.E. D.W.and S. Division Garhwa
₹4.1 L
Yes
Office of the R.C.E. DWSD Ranchi Zone Ranchi
8 Mar 2022
14 Jan 2022
25 Jan 2022
14 Jan 2022
22 Jan 2022
17 Jan 2022
17 Jan 2022
Amount
Model-01 :- 05 Nos Scheme and 54 Nos H.C.
(A) Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump (Model-01)
Designing, Supplying, Installation, Testing & Commissioning with all tools & Parts of following Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump Suitable for minimum 125mm x 115mm bore well as per MNRE Guideline with following specifications & accessories.
SPV arrays contains specified No of same capacity type & specification modules connected to series or parallel to obtained the required voltage & current the power output of individual PV modules should be minimum 200 watt peak.
i) The SPV modules should be as per IEC-61215 and IEC 61730 part 1.0)
ii) All external parts of motor pump used in submersible pump which are in contact of water is stainless steel grade 303 or higher as required.
iii) The PV modules should be mounted on metallic structure of adequate strength and appropriate design which can withstand load of modules & High wind pressure up to 200Km/h.
iv) The module mounting structure should be hot dip galvanized according to IS 4759.
v) To enhance the performance of SPV water pumping system & arrangement for seasonal tilt angle Adjustment should be provided
vi) Necessary arrangement should be provided in controller automatic start-run-stop through out the day with water level detection system. (As per MNRE Specification)
vii) Necessary protection such as lightening arrestor etc. should be provided to protect the controller & SPV
viii) The suction/delivery pipe shall be UPVC / H.D.P.E. pipes of appropriate size 60m or more as required minimum pressure rating of 8kg/Sq cm- PE 100 grade for pump up to 3HP & 10 Kg/Sq cm- PE 100 grade for 5 HP.
ix) All cable used shall be as per IS 694. Suitable size of cable shall be used in sufficient length for inter connection between the SPV array to SPV controller and SPV controller to solar power pump. Provision of cable shall be as per IS 14536.
x) The motor pump set should have a 5 years warranty.
xi) Control panel suitable for motor pump with arrangement of dry run & over flow protection sensor, float switch & rain prevention box. (As per MNRE Specification)
xii) The SPV controller must have IP-65 protection or must be housed in cabinet having at least IP-65 protection.
xiii) The system should be as per MNRE guide line & Eco-friendly with suitable arrangement to operate new pump manually.
xiv) With third party inspection before dispatch.
xv) Provision for web based remote monitoring of the pumps to be installed must be made through the inbuilt controllers . It should be possible to ascertain the daily water output, the power generated by PV Array ,the Up and down time of the pump during the year, number of days the pump was unused or under breakdown repairs.
The following details should be marked indelibly on the motor pump set
a) Name of the Manufacturer or Distinctive Logo.
b) Model Number.
c) Serial Number.
Solar submersible motor pump (SPV DC Type)
i) 1 HP (DC Pump) with 900 WP minimum watt P.V. Panel as MNRE pump head Max Shut-off head up to 120 mtrs. For higher or lower head or in between various modules output could be decided on prorates basis. (As per latest guide line of MNRE)
Carrying out recuperation/Yield Test for ascertaining the discharge of constructed well/ excavated profile as directed by the IEC. The test out by the drawing down water from the well/ profile below normal/subsoil water level up to full depth rise is recorded the normal water level/subsoil water level in the well / profile as well as strainer/level at pump as per design of W.S. scheme shall be recorded prior to the test including cost of all materials, over Load , Labours etc. complete as directed.
Supplying all labours, tools and equipments for dismantling of head & water tank assembly and taking out 32 mm dia old G.I. Pipe, connecting rod, cylinder assembly the dismantled components after necessary changing for making the T/W in good condition with all transportation including unused taken out materials back in store all complete job as per direction of E/I. (As per Model Estimate of Solar Energy based Mini WSS. TS done by SE, Ranchi Circle & Circle Gumla dt. 21.05.2019)
Provision of solar night lamp.
(B) 4000 Litre Capacity R.C.C. Water Tank
Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item-B ) and disposal of excavated earth as obtained to a distance up to 50 m including all lifts,levelling,ramming the foundation trenches, removing roots of trees shrubs all complete as per approved design, building specification and direction of E/I. B.C.D (3.1.1.1)
Providing P.C.C.M-150 in nominal mix of (1:2:4) in foundation with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including screening, mixing cement concrete in mixer and placing in position,vibrating,curing,taxes and royalty all complete as per building specification direction of E/I. B.C.D 5.3.1.
Providing and laying in situ Cement concrete of trap/granite/quartzite/ gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, 'plywood form work, bully/steel propups, compaction, finishing and curing, etc, complete. (By weigh batching and mix design for M-250 only. Use of L & T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (excluding M.S. or Tor reinforcement) Section-G-Plain and Reinforced Cement Concrete-item 10 b B.C.D 5.3.2.1
Providing and casting in situ Cement Concrete of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, 'plywood formwork, bully/steel prop-ups, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only.Use of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted) (excluding M.S, or Tor reinforcement) For RCC M-250 grade Column Section-G-Plain and Reinforced Cement Concrete-item B.C.D 5.3.10
A. Column Utility Room. Roof beam to Tank beam BCD - 5.3.11
Providing and casting in situ Cement Concrete of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, 'plywood formwork, bully/steel prop-ups, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted) (excluding M.S, or Tor reinforcement) For RCC M-250 grade Beams/Braces/Lintels -Section-G-Plain and Reinforced Cement Concrete-item 13 C
Total Rate - 7818+10% (BCD 5.3.10)
Total-Rate - 7827+10% (BCD 5.3.13)
Providing and casting in situ Cement Concrete of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, 'plywood formwork, bully/steel prop-ups, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted) (excluding M.S, or Tor reinforcement) For RCC M-300 grade Slabs / Landings / Vertical Walls
Total Rate - 7828+20% (BCD 5.3.13)
Total-Rate - 7818+20% (BCD 5.3.11)
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads including cost of materials,labours,royality and taxes all complete as per building specification and direction of E/I.(Mode of measurement-compacted volume).BCD-5.1.10
Providing designation 75 A one brick flat soling joints filled with local sand including cost of watering, taxes royalty all complete as per building specification and direction of E/I. (BCD 5.6.1)
Filling in foundation trenches and plinth in layers not exceeding 150mm thick, well watered,rammed,fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50M and lift of 1.5M all complete as per building specifications and direction of E/I.(Mode of measurement-compacted volume). B.C.D 5.1.7
Providing designation 75 A Brick work in C.M(1:6) in foundation and plinth with approved quality of clean coarse sand of F.M.2 to2.5 including providing 10mm thick mortar joints, cost of screening,scaffolding,raking out joints to 15mm depth,curing,taxes and royalty all complete as per building specification and direction of E/I. 5.2.3/
Providing designation 75A Brick work in C.M(1:6) in superstructure with approved quality of clean coarse sand of F.M 2 to 2.5 including providing 10mm thick mortar joints, cost of screening,scaffolding,raking out joints 15mm depth,curing,taxes and royalty all complete as per bldg. specification and direction of E/I. 5.2.11/
Providing R.C.C.M-200 in nominal mix of (1:1:5:3) in lintel with approved quality of stone chips (20mm to 6mm size) graded and clean coarse of F.M 2.5 to 3 including screening, centering, shuttering, mixing cement concrete in mixer and placing in position, vibrating striking, curing(but excluding the cost of reinforcement),taxes and royalty all complete as per building specification and direction of E/I. (5.3.11)
Providing av.63 mm thick R.C.C M-200 in nominal mix of (1:1.5:3) chhajja with approved quality of stone chips (20mm to 6mm size) graded and clean coarse sand of F.M 2.5 to 3 including in mixer and placing in position,vibrating,striking,6mm cement plaster(1:4) in ceiling and sides of chhajja with sand of F.M 1.5, curing(but excluding the cost of reinforcement) taxes, and royalty all complete as per building specification and direction of E/I. 5.3.11
Providing T.M.T steel reinforcement of different dia rods as per approved design and drawing including carriage of M.S bars to work site, cutting bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. 5.5.5
Supplying, fitting and fixing M.S grill made of 20*6 mmM.S flats as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. 5.5.12
Providing and fixing fan hooks of 16 mm dia M.S.bar & 1 meter long bent to required size and shape, placed in position and fixed in the R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/I. 5.5.13
Supplying, fitting and fixing 20 gauge G.C.I sheet gate fitted on M.S angle frame of size 60*60*6 mm including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in C/C(1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. 5.5.29
Providing 12 mm cement plaster (1:4) with clean coarse sand of F.M 1.5 including cost of screening, curing with all leads and lifts of water,scaffolding,taxes and royalty all complete as per building specification and direction of E/I. 5.7.2
Providing 12 mm cement plaster (1:6) with clean coarse sand of F.M 1.5 including cost of screening, curing with all leads and lifts of water,scaffolding,taxes and royalty all complete as per building specification and direction of E/I. BCD-5.7.03
Providing 6 mm cement plaster (1:4 ) in ceiling with clean coarse sand of F.M 1.5 including cost of screening, curing with all leads and lifts of water,scaffolding,taxes and royalty all complete as per building specification and direction of E/I. BCD-5.7.6
Providing 12 mm cement plaster (1:3) with clean coarse sand of F.M 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor,curing,taxes and royalty all complete as per building specification and direction of E/I. BCD-5.6.10
Providing 19 mm water proof cement plaster (1:3) with clean coarse sand of F.M 1.5 with 5% cico or any other approved water proofing compound including cost of screening, curing with all leads and lifts of water,scaffolding,taxes and royalty all complete as per building specification and direction of E/I. 5.7.15
Providing 1.5 mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I. BCD-5.7.11
Providing two coats of snowcem of approved shade and make over old surface including washing, cleaning, sand papering the wall,scaffolding,curing and taxes all complete as per building specification & direction of E/I.BCD-5.8.24
Extra for each coat of cement wash, distemper paint or snowcem over exterior surface for each consecutive floor above first floor including scaffolding etc all complete as per building specification & direction of E/I. BCD-5.8.25
Providing two coats of synthetic enamel paint of approved shade and make over steel surface throughly,scaffolding and taxes all papering including cost of scaffolding and taxes all complete as per building specification & direction of E/I. BCD-5.8.45
Providing and fixing G.I. pipe railing having 1.0 M height consisting 50 x 50 x 6 mm thick M. S. angles as verticals at 1.5 M c/c, and additional posts at every corner with 3 rows of 25 mm dia G.I. pipes of medium class variety as horizontal and painting 3 coats of oil paint over 1 coat of anticorrosive paint of approved colour and shade including cost of all labour, transporting bends to curved shape, etc. complete. Section-H-Miscellaneous Works 48 item -1
Providing and fixing in position M.S. ladder 0.50 M wide consisting of 75 x 10 mm M.S. flats as stringers and 16 mm dia M.S. bars in double rows as steps placed at 25 cm c/c including cost of material and labour involved, welding, anchoring and applying 3 coat of anti-corrosive paint, etc. complete as directed by Engineer-in-charge. Section-K-ANCILLARY ITEMS FOR RESERVOIRS 225 Item No-5
Carriage of materials :-
Cement 10 Km
Steel 10 Km
Bricks - 10 Km
Sand- 15 km
Stone Chips- 25 Km
(C) Rising Network :-
Earth work in excavation in foundation trenches in hard soil (Vide Classification soil item B) and disposal of excavated earth as obtained to a distance up to 50 Mtr. including all lifts, leveling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, specification and direction of E/I. (DWSD-3.1.1.1)/84
Manufacture, supply and Delivery of following Nominal dia UPVC column pipes including PVC socket (Coupler),
65mm dia -Density of pipe 1.38 to 1.43 Gm per Cm3 OD:74.5 to 75.2mm wall Thickness End:9mm to 10.7mm, Barrel 9mm to 10.7 mm, Length: 3Mtrs.Rising main
50 mm dia -Density of pipe 1.38 to 1.43 Gm per Cm3 OD:87.5 to 88.2mm wall Thickness End:9 .8 mm to 11.9mm, Barrel 7.3mm to 9 mm, Length: 3Mtrs. Delivery Pipe
Providing and fixing Gun Metal Gate valve with C I wheel of approved quality(screwed end).DSR 18.17.5
50 mm dia .
63mm dia
Lowering, Laying and Jointing H. D. P. E. in proper position including all specials by compression fitting/electro fusion and butt fusion jointing procedure as per relevant IS Code complete with all materials for jointing procedure like Electro fusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II. MJP 19-20 sec-I-IX sl no -2(i)
63 mm HDPE Pipe-
50 mm HDPE Pipe-
Providing brick massonary chamber on inner size 600x600x450 mm deep for borewell protection having 125 mm thick wall (1:4) and 75 mm RCC cover do all complete job as per E/I
Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-Charge. 3.4.2/84 (85% of item no. )
Distribution Network :-
Earth work in excavation in foundation trenches in hard soil (Vide Classification soil item B) and disposal of excavated earth as obtained to a distance up to 50 Mtr. including all lifts, leveling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, specification and direction of E/I. (DWSD-3.1.1.1)/84
Dismantling plain cement concrete work including stacking serviceable materials in countable stacks within 15 M lead and disposal of unserviceable materials with all leads all complete BCD-5.10.2
Providing PCC M-200 with nominal mix of (1:1.5:3) with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of FM 2.5 to 3.0 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, sticking, curing , taxes and royalty all complete as per specification and direction of E/I. for construction of road cutting portion- BCD-1.2.8(b)/158
Providing and supplying High Density Polyethylene pipe (HDPE pipe) of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties. PE-80 , PN- 10
63 mm HDPE Pipe- 84/112
50 mm HDPE Pipe- 84/112
32 mm HDPE Pipe- 84/112
Providing & Supply of Electro Fusion Fittings in accordance with BS EN12201 part-3 suitable for drinking water with in blank/blue colour manufactured from compounded PE80/PE100 virgin polymer and competable with PE80/PE100 pipes, in pressure rating SDR-11 with min PN12.5 rated for water application and shall be inclusive of all cost such as testing inspection charges transportation upto store, trangit insurance, loading, unloading, staking excluding GST levied by GOI & GOM in all respect etc. complete.
(1) Couplers
(a) 63 mm dia
(b) 50 mm dia
(c) 32 mm dia
(2) Eaual TEE
(a) 63 mm dia
(b) 50 mm dia
(c) 32 mm dia
(3) Elbow 90o
(a) 63 mm dia
(b) 50 mm dia
(c) 32 mm dia
(4) Reducer
(a) 63 x 32 mm dia
(5) EFR TEE
(a) 63x63x50 mm dia
(b) 50x50x32 mm dia
(6) End Cap
(a) 63 mm dia
(b) 50 mm dia
(c) 32 mm dia
Lowering, Laying and Jointing H. D. P. E./M. D.P. E. pipes in proper position including all specials by compression fitting/electro fusion and butt fusion jointing procedure as per relevant IS Code complete with all materials for jointing procedure like Electro fusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II. MJP 19-20 sec-I-IX sl no -2(i)
63 mm HDPE Pipe-
50 mm HDPE Pipe-
32 mm HDPE Pipe-
Providing and fixing Gun Metal Fullway valve with C I wheel of approved quality(screwed end)
65 mm dia . 924/32 41.5 Kg.
50 mm dia Fullway valve
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design.With common burnt clay F.P.S.(non modular) bricks of class designation
Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-Charge. 3.1.1.2/04
(D) House Connection (54 Nos)
Earth work in excavation in foundation trenches in hard soil (Vide Classification soil item B) and disposal of excavated earth as obtained to a distance up to 50 Mtr. including all lifts, leveling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, specification and direction of E/I.
Providing and supplying High Density Polyethylene pipe (HDPE pipe) of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties. PE-80 , PN- 10 20mm dia HDPE Pipe
Lowering, Laying and Jointing H. D. P. E./M. D.P. E. pipes in proper position including all specials by compression fitting/electro fusion and butt fusion jointing procedure as per relevant IS Code complete with all materials for jointing procedure like Electro fusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge 20mm dia HDPE Pipe
Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-Charge.
Providing 15 mm dia. G.I. pipe Tata or equivalent make as per IS 1239 (Part 1/2004) ISI Mark /medium quality in Stand Post. DWSD Sl. 9K (including CP+OHC)
Supplying all materials, labour and tools for fixing 15 mm dia G.I. pipes with Red lead and yarn of following nominal bore with screwed and socketed joints on wall, ceiling and floor including supplying and fitting of wall hooks or pipe clamps, wooden plugs, cutting pipes to size and threading ends if required etc. all complete as per specification and direction of Engineer-in-Charge. DWSD 3.1.1
Supplying and fixing G.I. fittings of approved make all complete as per specification and direction of E/I. DWSD 3.1.13
(a) Elbow- 15 mm dia. 3.1.13
(a) R. Socket- 20 x 15 mm dia.
(a) Nipple- 15 mm dia.
(a) Plain Socket- 15 mm dia.
Supplying and fixing G.M. ferrule of approved make in existing C.I./D.I. main Including drilling and taping C.I./D.I. main all complete as per specification and direction of E/I. 3 mm, 6 mm 10 mm dm ferrule weight not less than 425 gram. (JOSR DWSD 3.1.4.1)/85
Supplying materials , labours and equipment's for construction of 0.90M x 0.90 M size P.C.C. (1:2:4) Rectangular Platform with stand post in house including 12 mm thick cement plaster in C.M. (1:4) with neat cement punning over exposed surface all complete job, as per approved design, specification and direction of E/I. (As per Annexure II Attached)
Providing and fixing of male ended C.I.Body brass spindle valve and seat Bib cock of approved quality with extra socket all complete as per specification and direction of E/I. DWSD 3.1.5.2
Providing fitting & fixing 32 mm to 50 mm service HDPE saddle all complete job, as per approved design, specification and direction of E/I.
Hence O & M Cost for 1st year (Excluding Repair Charges)
O & M cost for 2nd Year = O & M for 1st Yr + 6% of O&M for 1st Year + Annual repairing Charges
O & M cost for 3rd Year =1.06 x 2st year
O & M cost for 4th Year =1.06 x 3rd year
O & M cost for 5th Year =1.06 x 4th year
Provision of one no SIM card & its recharging cost for RMC
Model-02 :- 34 Nos Scheme and 1351 Nos H.C.
Construction of 125mm x115mm x 90.0 M deep Drilled Tube Well
(A) Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump
Supplying all materials, labour and tools and equipment for drilling 125 x 115 mm dia bore well in any kinds of soil and rocks by using D.T.H. super rig machine and ball hammer technology including all technology inclusive of mobilization, demobilization of rigs air compressor all accessories of rigs tools and plant labour etc. all complete job including transportation charge cost of flushing charge, geographical investigation etc. all complete
(a) 0.00m Up to 30.00m depth below G.L. In Rural Areas (DWSD 118)
(b) 30.000m Up to 90.00m depth beyond . In Rural Areas
Basic rate of 125mmdia Blue UPVC Casing pipe Confirming to I.S.I . latest revision IS(12818)/2016 C.M.L. No-5543459 (DWSD 105)
Supplying all materials, labour and inserting UPVC blue pipe 125 mm internal dia casing pipe for protecting the bore hole in over burden up to hard surface as per IS 12818-1392 with latest revision all complete job with taxes as per specification and direction of E/I. (DWSD 122)
Supplying labour cement and calcium chloride or bentonite solution and equipment’s for grouting Casing pipe (DWSD 124)
Supplying all tools, equipments and labour and doing washing, flushing, and developing of drilled tube well to give clean and clear water all complete job as per direction of E/I.
Supplying labours and equipment’s including 125mm dia G.I. Cap & fitting and fixing over the casing pipe of bore well properly and taking it out as per direction of E/(DWSD 125)
Supplying materials and labours for constructing bore well chamber of 75B designation brick masonry chamber 600mmx450mm and 750mm deep internal dimension having 250mm thickness in cement mortar 1:6 including 12mm cement plaster 1:6 with 600mmx475mm RCC cover with earth work in excavation and 75mm thick PCC(1:3:6) in foundation and refilling all complete as per specification and direction of E/I (Annexure I Attached)
(B) Provision of 2 HP DC Solar Motor Pump Complete Set
Designing, Supplying, Installation, Testing & Commissioning with all tools & Parts of following Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump Suitable for minimum 125mm x 115mm bore well as per MNRE Guideline with following specifications & accessories.
SPV arrays contains specified No of same capacity type & specification modules connected to series or parallel to obtained the required voltage & current the power output of individual PV modules should be minimum 200 watt peak.
i) The SPV modules should be as per IEC-61215 and IEC 61730 part 1.0)
ii) All external parts of motor pump used in submersible pump which are in contact of water is stainless steel grade 303 or higher as required.
iii) The PV modules should be mounted on metallic structure of adequate strength and appropriate design which can withstand load of modules & High wind pressure up to 200Km/h.
iv) The module mounting structure should be hot dip galvanized according to IS 4759.
v) To enhance the performance of SPV water pumping system & arrangement for seasonal tilt angle Adjustment should be provided
vi) Necessary arrangement should be provided in controller automatic start-run-stop through out the day with water level detection system. (As per MNRE Specification)
vii) Necessary protection such as lightening arrestor etc. should be provided to protect the controller & SPV
viii) The suction/delivery pipe shall be UPVC / H.D.P.E. pipes of appropriate size 60m or more as required minimum pressure rating of 8kg/Sq cm- PE 100 grade for pump up to 3HP & 10 Kg/Sq cm- PE 100 grade for 5 HP.
ix) All cable used shall be as per IS 694. Suitable size of cable shall be used in sufficient length for inter connection between the SPV array to SPV controller and SPV controller to solar power pump. Provision of cable shall be as per IS 14536.
x) The motor pump set should have a 5 years warranty.
xi) Control panel suitable for motor pump with arrangement of dry run & over flow protection sensor, float switch & rain prevention box. (As per MNRE Specification)
xii) The SPV controller must have IP-65 protection or must be housed in cabinet having at least IP-65 protection.
xiii) The system should be as per MNRE guide line & Ecofriendly with suitable arrangement to operate new pump manually.
xiv) With third party inspection before dispatch.
xv) Provision for web based remote monitoring of the pumps to be installed must be made through the inbuilt controllers . It should be possible to ascertain the daily water output, the power generated by PV Array ,the Up and down time of the pump during the year, number of days the pump was unused or under breakdown repairs.
The following details should be marked indelibly on the motor pump set
a) Name of the Manufacturer or Distinctive Logo.
b) Model Number.
c) Serial Number.
Solar submersible motor pump (SPV DC Type)
i) 2 HP (DC Pump) with 1800 wp minimum watt P.V. Panel as MNRE pump head Max Shut-off head up to 100 mtrs. For higher or lower head or in between various modules output could be decided on prorates basis. (As per latest guide line of MNRE)
Provision of solar night lamp.
(C) 8000 Litres Capacity RCC Water Tank
Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item-B ) and disposal of excavated earth as obtained to a distance up to 50 m including all lifts,levelling,ramming the foundation trenches, removing roots of trees shrubs all complete as per approved design, building specification and direction of E/I. BCD-3.1.1.1(b)
Providing P.C.C.M-150 in nominal mix of (1:2:4) in foundation with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including screening, mixing cement concrete in mixer and placing in position,vibrating,curing,taxes and royalty all complete as per building specification direction of E/I. BCD-5.3.2
Providing and laying in situ Cement concrete of trap/granite/quartzite/ gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, 'plywood form work, bully/steel propups, compaction, finishing and curing, etc, complete. (By weigh batching and mix design for M-250 only. Use of L & T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (excluding M.S. or Tor reinforcement) Section-G-Plain and Reinforced Cement Concrete-item 10 b
Providing and casting in situ Cement Concrete of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, 'plywood formwork, bully/steel prop-ups, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only.Use of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted) (excluding M.S, or Tor reinforcement) For RCC M-250 grade Column Section-G-Plain and Reinforced Cement Concrete-item
A. Column Utility Room. Roof beam to Tank beam M-25
B. Column Tank beam to tank Roof M-30
Providing and casting in situ Cement Concrete of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, 'plywood formwork, bully/steel prop-ups, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted) (excluding M.S, or Tor reinforcement) For RCC M-250 grade Beams/Braces/Lintels -Section-G-Plain and Reinforced Cement Concrete-item 13 C
Total Rate -7818+10% (BCD 5.3.10)
Total-Rate -7827+10% (BCD 5.3.13)
Providing and casting in situ Cement Concrete of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, 'plywood formwork, bully/steel prop-ups, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted) (excluding M.S, or Tor reinforcement) For RCC M-300 grade Slabs / Landings / Vertical Walls
Total
Total
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads including cost of materials,labours,royalityand taxes all complete as per building specification and direction of E/I.(Mode of measurement-compacted volume).BCD-5.1.10/156
Providing designation 75 A one brick flat soling joints filled with local sand including cost of watering, taxes royalty all complete as per building specification and direction of E/I. BCD-5.6.2/99
Filling in foundation trenches and plinth in layers not exceeding 150mm thick, well watered,rammed,fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50M and lift of 1.5M all complete as per building specifications and direction of E/I.(Mode of measurement-compacted volume). BCD-5.1.7/156
Providing designation 75 A Brick work in C.M(1:6) in foundation and plinth with approved quality of clean coarse sand of F.M.2 to2.5 including providing 10mm thick mortar joints, cost of screening,scaffolding,raking out joints to 15mm depth,curing,taxes and royalty all complete as per building specification and direction of E/I. BCD-5.2.3/153
Providing designation 75A Brick work in C.M(1:6) in superstructure with approved quality of clean coarse sand of F.M 2 to 2.5 including providing 10mm thick mortar joints, cost of screening,scaffolding,raking out joints 15mm depth,curing,taxes and royalty all complete as per bldg. specification and direction of E/I.BCD-5.2.11/153
Providing R.C.C.M-200 in nominal mix of (1:1:5:3) in lintel with approved quality of stone chips (20mm to 6mm size) graded and clean coarse of F.M 2.5 to 3 including screening, centering, shuttering, mixing cement concrete in mixer and placing in position, vibrating striking, curing(but excluding the cost of reinforcement),taxes and royalty all complete as per building specification and direction of E/I. BCD-5.3.11
Providing av.63 mm thick R.C.C M-200 in nominal mix of (1:1.5:3) chhajja with approved quality of stone chips (20mm to 6mm size) graded and clean coarse sand of F.M 2.5 to 3 including in mixer and placing in position,vibrating,striking,6mm cement plaster(1:4) in ceiling and sides of chhajja with sand of F.M 1.5, curing(but excluding the cost of reinforcement) taxes, and royalty all complete as per building specification and direction of E/I. BCD-5.3.11
Providing T.M.T steel reinforcement of different dia rods as per approved design and drawing including carriage of M.S bars to work site, cutting bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. BCD- 1.4.2/152
Supplying, fitting and fixing M.S grill made of 20*6 mmM.S flats as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. BCD-5.5.12/94
Providing and fixing fan hooks of 16 mm dia M.S.bar & 1 meter long bent to required size and shape, placed in position and fixed in the R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/I. BCD-5.5.13/95
Supplying, fitting and fixing 20 gauge G.C.I sheet gate fitted on M.S angle frame of size 60*60*6 mm including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in C/C(1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. BCD-5.5.29/97
Providing 12 mm cement plaster (1:4) with clean coarse sand of F.M 1.5 including cost of screening, curing with all leads and lifts of water,scaffolding,taxes and royalty all complete as per building specification and direction of E/I. BCD-5.7.2
Providing 12 mm cement plaster (1:6) with clean coarse sand of F.M 1.5 including cost of screening, curing with all leads and lifts of water,scaffolding,taxes and royalty all complete as per building specification and direction of E/I. BCD-5.7.03
Providing 6 mm cement plaster (1:4 ) in ceiling with clean coarse sand of F.M 1.5 including cost of screening, curing with all leads and lifts of water,scaffolding,taxes and royalty all complete as per building specification and direction of E/I. BCD-5.7.6
Providing 12 mm cement plaster (1:3) with clean coarse sand of F.M 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor,curing,taxes and royalty all complete as per building specification and direction of E/I. BCD-5.6.10
Providing 19 mm water proof cement plaster (1:3) with clean coarse sand of F.M 1.5 with 5% cico or any other approved water proofing compound including cost of screening, curing with all leads and lifts of water,scaffolding,taxes and royalty all complete as per building specification and direction of E/I. 5.7.15
Providing 1.5 mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I. 5.7.11
Providing two coats of snowcem of approved shade and make over old surface including washing, cleaning, sand papering the wall,scaffolding,curing and taxes all complete as per building specification & direction of E/I 5.8.24
Extra for each coat of cement wash, distemper paint or snowcem over exterior surface for each consecutive floor above first floor including scaffolding etc all complete as per building specification & direction of E/I. 5.8.25
Providing two coats of synthetic enamel paint of approved shade and make over steel surface throughly,scaffolding and taxes all papering including cost of scaffolding and taxes all complete as per building specification & direction of E/I. BCD-5.8.45
Providing and fixing G.I. pipe railing having 1.0 M height consisting 50 x 50 x 6 mm thick M. S. angles as verticals at 1.5 M c/c, and additional posts at every corner with 3 rows of 25 mm dia G.I. pipes of medium class variety as horizontal and painting 3 coats of oil paint over 1 coat of anticorrosive paint of approved colour and shade including cost of all labour, transporting bends to curved shape, etc. complete. Section-H-Miscellaneous Works 48 item -1
Providing and fixing in position M.S. ladder 0.50 M wide consisting of 75 x 10 mm M.S. flats as stringers and 16 mm dia M.S. bars in double rows as steps placed at 25 cm c/c including cost of material and labour involved, welding, anchoring and applying 3 coat of anti-corrosive paint, etc. complete as directed by Engineer-in-charge. Section-K-ANCILLARY ITEMS FOR RESERVOIRS 225 Item No-5
Carriage of materials
Cement 10 Km
Steel 10 Km
Bricks - 10 Km
Sand- 15 km
Stone Chips- 25 Km
(C) Rising Network :-
Earth work in excavation in foundation trenches in hard soil (Vide Classification soil item B) and disposal of excavated earth as obtained to a distance up to 50 Mtr. including all lifts, leveling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, specification and direction of E/I. (DWSD-3.1.1.1)/84
Manufacture, supply and Delivery of following Nominal dia UPVC column pipes including PVC socket (Coupler),
65mm dia -Density of pipe 1.38 to 1.43 Gm per Cm3 OD:74.5 to 75.2mm wall Thickness End:9mm to 10.7mm, Barrel 9mm to 10.7 mm, Length: 3Mtrs.Rising main
50 mm dia -Density of pipe 1.38 to 1.43 Gm per Cm3 OD:87.5 to 88.2mm wall Thickness End:9 .8 mm to 11.9mm, Barrel 7.3mm to 9 mm, Length: 3Mtrs. Delivery Pipe
Providing and fixing Gun Metal Gate valve with C I wheel of approved quality(screwed end).DSR 18.17.5
50 mm dia .
63mm dia
Lowering, Laying and Jointing H. D. P. E. in proper position including all specials by compression fitting/electro fusion and butt fusion jointing procedure as per relevant IS Code complete with all materials for jointing procedure like Electro fusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II. MJP 19-20 sec-I-IX sl no -2(i)
63 mm HDPE Pipe-
50 mm HDPE Pipe-
Providing brick massonary chamber of inner size 600x600x450 mm deep for borewell protection having 125 mm thick wall (1:4) and 75 mm RCC cover do all complete job as per E/I
Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-Charge. 3.4.2/84
Distribution Network :-
Earth work in excavation in foundation trenches in hard soil (Vide Classification soil item B) and disposal of excavated earth as obtained to a distance up to 50 Mtr. including all lifts, leveling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, specification and direction of E/I. (DWSD-3.1.1.1)/84
Dismantling plain cement concrete work including stacking serviceable materials in countable stacks within 15 M lead and disposal of unserviceable materials with all leads all complete BCD-5.10.2
Providing PCC M-200 with nominal mix of (1:1.5:3) with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of FM 2.5 to 3.0 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, sticking, curing , taxes and royalty all complete as per specification and direction of E/I. for construction of road cutting portion- 158/1.2.8(b)
Providing and supplying High Density Polyethylene pipe (HDPE pipe) of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties. PE-80 , PN- 10
63 mm HDPE Pipe- 84/112
50 mm HDPE Pipe- 84/112
32 mm HDPE Pipe- 84/112
Providing & Supply of Electro Fusion Fittings in accordance with BS EN12201 part-3 suitable for drinking water with in blank/blue colour manufactured from compounded PE80/PE100 virgin polymer and competable with PE80/PE100 pipes, in pressure rating SDR-11 with min PN12.5 rated for water application and shall be inclusive of all cost such as testing inspection charges transportation upto store, trangit insurance, loading, unloading, staking excluding GST levied by GOI & GOM in all respect etc. complete.
(1) Couplers
(a) 63 mm dia
(b) 50 mm dia
(c) 32 mm dia
(2) Eaual TEE
(a) 63 mm dia
(b) 50 mm dia
(c) 32 mm dia
(3) Elbow 90o
(a) 63 mm dia
(b) 50 mm dia
(c) 32 mm dia
(4) Reducer
(a) 63 x 32 mm dia
(5) EFR TEE
(a) 63x63x50 mm dia
(b) 50x50x32 mm dia
(6) End Cap
(a) 63 mm dia
(b) 50 mm dia
(c) 32 mm dia
Lowering, Laying and Jointing H. D. P. E./M. D.P. E. pipes in proper position including all specials by compression fitting/electro fusion and butt fusion jointing procedure as per relevant IS Code complete with all materials for jointing procedure like Electro fusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II. MJP 19-20 sec-I-IX sl no -2(i)
63 mm HDPE Pipe-
50 mm HDPE Pipe-
32 mm HDPE Pipe-
Providing and fixing Gun Metal Fullway valve with C I wheel of approved quality(screwed end).DSR 18.17.5
63 mm dia .
50 mm dia
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design.With common burnt clay F.P.S.(non modular) bricks of class designation
Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-Charge. 3.1.1.2/84 (85% of item no 273)
(E) House Connection (1351 Nos)
Earth work in excavation in foundation trenches in hard soil (Vide Classification soil item B) and disposal of excavated earth as obtained to a distance up to 50 Mtr. including all lifts, leveling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, specification and direction of E/I.
Providing and supplying High Density Polyethylene pipe (HDPE pipe) of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties. 20mm dia MDPE Pipe
Lowering, Laying and Jointing H. D. P. E./M. D.P. E. pipes in proper position including all specials by compression fitting/electro fusion and butt fusion jointing procedure as per relevant IS Code complete with all materials for jointing procedure like Electro fusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge 20mm dia HDPE Pipe
Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-Charge.
Providing 15 mm dia. G.I. pipe Tata or equivalent make as per IS 1239 (Part 1/2004) ISI Mark /medium quality in Stand Post. DWSD Sl. 9K (including CP+OHC)
Supplying all materials, labour and tools for fixing 15 mm dia G.I. pipes with Red lead and yarn of following nominal bore with screwed and socketed joints on wall, ceiling and floor including supplying and fitting of wall hooks or pipe clamps, wooden plugs, cutting pipes to size and threading ends if required etc. all complete as per specification and direction of Engineer-in-Charge. DWSD 3.1.2(1)
Supplying and fixing G.I. fittings of approved make all complete as per specification and direction of E/I. DWSD 3.1.13
(a) 15 mm dia. Elbow 3.1.13
(a) 20 x 15 mm dia. Reducer Socket
(a) 15 mm dia. Nipple
(a) 15 mm dia. Plain Socket
Supplying and fixing G.M. ferrule of approved make in existing C.I./D.I. main Including drilling and taping C.I./D.I. main all complete as per specification and direction of E/I. 3 mm, 6 mm 10 mm dm ferrule weight not less than 425 gram. (JOSR DWSD 3.1.4.1)/85
Providing and fixing of male ended C.I.Body brass spindle valve and seat Bib cock of approved quality with extra socket all complete as per specification and direction of E/I. DWSD 3.1.5.2
Supplying materials , labours and equipment's for construction of 0.90M x 0.90 M size P.C.C. (1:2:4) Rectangular Platform with stand post in house including 12 mm thick cement plaster in C.M. (1:4) with neat cement punning over exposed surface all complete job, as per approved design, specification and direction of E/I. (As per Annexure II Attached)
Providing fitting & fixing 32 mm to 50 mm service HDPE saddle all complete job, as per approved design, specification and direction of E/I.
Hence O & M Cost for 1st year (Excluding Repair Charges)
O & M cost for 2nd Year = O & M for 1st Yr + 6% of O&M for 1st Year + Annual repairing Charges
O & M cost for 3rd Year =1.06 x 2st year
O & M cost for 4th Year =1.06 x 3rd year
O & M cost for 5th Year =1.06 x 4th year
Provision of one no SIM card & its recharging cost for RMC
Add 12% GST
Add 1% Labour Cess
SATYA SHREE SAI CONSTRUCTION COMPANY
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
SBD.pdf
Tender Documents • 3.74 MB
BOQ_74447.xls
BOQ • 1.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .