| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49,565Accepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹52,360−₹7,205 (12.1%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹55,863−₹3,702 (6.22%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹88,782+₹29,217 (49.1%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹99,850+₹40,285 (67.6%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹1.0 L
Closing Date
7 Jan 2021, 3:00 pmClosed
Executive Engineer
EandM Division, APWD, Prothrapur, Port Blair
Construction of Anganwadi Centre under PMJVK Scheme at Bambooflat Surya Chakra under RCD Wimberlygunj SW Providing IEI
2020_APWD_1739_1
NIT No. 48/EE/EandM/20-21
Open Tender
Electrical Works
Item Rate
30 days
South Andaman
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
Exempted
16 Feb 2021
21 Dec 2020
8 Jan 2021
22 Dec 2020
7 Jan 2021
28 Dec 2020
22 Dec 2020 - 24 Dec 2020
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. a) Group C
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required a) 5/6 A switch
b) 3 pin 5/6 A socket outlet
c) 15/16 A switch
d) 6 pin 15/16 A socket outlet
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. a) 6 Module (200mmX75mm)
b) 3 Module (100mmX75mm)
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required
Supplying of LED Lamp 12W B22 etc., as required for Batten Holder.
Supplying of LED Fitting Box Type luminaires equivalent to Crompton Cat No. IGP131LT8 - 16 and LED Lamp T8 equivalent to Crompton Cat No. LT8- 865-2 or its equivalent.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supplying and Fixing of Street Light luminaires 25 Wattage, with pressure die cast aluminium housing heat resistant glass i/c Clamping arrangement with GI Pipe etc., as required. (Equivalent to Crompton Cat Ref. LSTS - 25- CDL) including Clamping arrangement with GI Pipe etc., as required.
Supplying of A.C Ceiling fan (1200 mm) sweep 5 Star rated with Socket Type Electronic regulator i/c wiring down rod of standard length (upto 30 cm) with all accessories etc as required. Similar to make Bajaj Code No. 250467 Kassels 50 ISI Marked (White C/F) or its equivalent
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and Fixing of 9 Watt LED Mirror Light Fitting with Decorative end Caps, polycarbonate body and ribbed opal diffuser similar to havells Cat No. LHEXARP6PN1W009 or its equivalent.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator a) 8 way , Double Door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required a) Single Pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required a) 40 A
Supplying and erection of metering box made out of SMC of overall size 310 x 285 x 180mm with hinged cover and locking arrangement, viewing glass etc., as required.
Providing earthing with safe earthing electrode of galvanization 80 to 100 microns, length 2 mtr, outer dia 50 mm, inner dia 19 mm and inner space be filled with crystalline conductive mixture including filling -up with electrolite (Back fill compound) as required for safe earth electrode and providing masonary enclosure with cover plate having locking arrangement etc. as required. (Ashlok)
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required
M K ENGINEERING
DILIP RAJ
KARBHAGAM SALES AGENCY
M/s G K Construction
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .