Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 LAccepted-Finance | ₹6.3 L | L1 | Accepted-Finance L-1, Due to LOA Issue |
| 2 | Rejected-Technical | - | - | Rejected-Technical Not Eligible due to Annexure-1 and 2 not Attached. Signed bid copy not attached. Turnover and Working Capital Certificate not attached,hence your bid can not accepted, Hence bid is Rejected. |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not Eligible due to Annexure-1 and 2 not Attached. Signed bid copy not attached. Turnover and Working Capital Certificate not attached,hence your bid can not accepted, Hence bid is Rejected. |
Tender Value
₹6.4 L
EMD Value
₹19,100
Closing Date
24 Mar 2026, 3:30 pmClosed
Dy. General Manager
O/o The D.G.M. (STM-STC) Dn. M.Deep, Budni, Bhairunda
Estimate for 11kv Bifurcation Rujankhedi AGR feeder Seelkanth S/s Under Bhairunda D/c under Bhairunda Dn.
2026_MKVVC_491770_1
DGM/STM-STC/MBB/Tender/2730/02 Dt. 17-03-2026
Open Tender
Electrical Works
60 days
Rujankhedi to Seelkanth
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
₹19,100
Yes
20 May 2026
17 Mar 2026
25 Mar 2026
17 Mar 2026
24 Mar 2026
17 Mar 2026
WPB160x160mm,30.44 Kg/Meter H beam,13 mtr long
140 Kg.,8.0 Mtrs. long PCC pole
IRON STEEL SCRAP h-beam 9 mtr long)
M S Channel 100X50x6 mm
M.S.Angle 50x50x6 mm
M S Angle 65X65X6 mm
11 KV Pin Insulator Polymer Composit (5 KN)
33 KV (45KN) Composite Polymer Disc Insulators
11 KV(45KN) Composite Polymer Disc Insulators
11 KV Strain hardware (T&C type) fittings
11 KV.C.Ts.(Outdoor dry type) 300-150/5-5 Amps
11 KV Single Phase PTs. (Resin Molded)
11 KV VCB, Outdoor Porcelain clad type with complete structure and accessories excluding CT & pannel
11 KV control & relay panel with numerical static relay for double feeder protection
11 KV, ISOLATOR 800 AMP.(Turn and twist type)
9 KV Gapless type(5 KA) polymer lightening arrestor
3 phase 4 wire 3x63.5 volts lb=5 amps Imax = 10 amp, HT trivector meter class of accuracy 0.5s, DLMS Compliant category A Meters along with GSM (GPRS compatible ) modems (For substation metering)
ACSR Panther conductor 0.20 sq. inch (200 sq.mm Al.Eq.)
AAAC Dog conductor 0.10 sq. inch (100 sq.mm. Al.Eq.)
AAAC Raccoon conductor 0.075 sq. inch (80 sq.mm. Al.Eq.)
Copper Control Cable 2 Core. 2.5 Sq.mm. (Unarmoured)
Copper Control Cable 4 Core. 2.5 Sq.mm. (Unarmoured)
Copper Control Cable 8 Core. 2.5 Sq.mm. (Unarmoured)
Copper Control Cable 12 Core. 2.5 Sq.mm. (Unarmoured)
G.I. Wire 3.15 mm. (10 SWG)
M.S.Flat 50x6 mm
M S FLAT 65X8 mm
Erection of Plinth per VCB- 33KV or 11KV
Stay Insulators 90X65mm
Back filling of poles with boulders.
Earthing Coil of 115 Turns of 50 MM.Dia and 2.5 Mtr. Lead of 4.0 MM G.I Wire
Earthing for PCC Pole 4.00 mm-8 SWG G.I wire- 0.8 Kg, per pole
M.S.Nuts with Bolts
Jointing Sleeves suitable for Dog (100Sq.mm.Al. Eq. ) AAAC conductor
Jointing Sleeves suitable for Rabbit (55Sq.mm.Al. Eq. ) AAAC conductor
Aluminium Binding wire and tape
Back Clamp for 140 Kg PCC Pole MS Flat 50x6 mm
MS strain plate 65x8mm 250mm long
STAY GI WIRE 7/4.00 MM.(7/8 SWG)
STAY WIRE 7/3.15 MM.(7/10 SWG)
Stay set complete without Stay wire 16 mm. (Painted)
Stay set 20 mm. complete without Stay wire (Painted)
Clamp 65X8 mm Flat of MS Flat for H-Beam ( Each weight 3.2 kg)
Danger Boards Enamelled 11 KV
Danger Boards Enamelled 33 KV
Red oxide paint
Aluminium paint
Concreting of stay (20 mm / 25 mm) @ 0.3 cmt. per stay
Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay
Stringing of Each 11 KV Bus-upper and lower bus including, drop jumpering and jointing with clamps,through outgoing VCB/ ME/ DP, upto station transformer
Concreting of foundation of VCB (1:3:6) @ 3.5 cmt per VCB plinth
Concreting of structures & foundation (1:3:6)
G.I. STRIP 25X3 MM1
G.I.Pipe 40 mm Dia C grade type
Galvanized nut & bolt with washer
Bentonite compound powder
33 KV composite polymer Strain set with hard ware suitable for Panther Conductor
Stone Block/Pre cast block for base pedding(450X450X75MM)
Carpet guarding
Marshelling box with 10 no. connectors
SHEET METAL METER BOX SUITABLE FOR H.T. STATIC TRAVECTOR METERS WITH TTB
T CLAMP FOR 33KV & 11KV BUS, SUBSTATION upto DOG
Anti climbing devices ( Barbed wire 2.24 mm dia, 14 SWG)
Labour Charges & all Fabrication Charges (STC Sub Division will provide the raw material like M.S. angle, M.S. Channel, M.S. flat, etc. to the contractor and the contractor will fabricate the items like V-cross arm, Top clamp, D.C. Channel, clamp, etc. as per site condition. Those fabrication charges are included in the Labour charges.) no extra amount will be paid.
Transportation Charges for All Equipments & Materials from area store to site & Site to Area store Bhopal
GST on Transportation @5%
GST on (Contractor side Material + Labour) @18%
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.10 MB
New_SBD_Rujankhedi.pdf
Tender Documents • 1.34 MB
BOQ_581384.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid