Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹4,964
Closing Date
17 Jun 2023, 2:30 pmClosed
The EE(E),ED-II,Kol
Office of Executive Engineer (E) BSNL Electrical Division- II TCO Building (1st floor) 33 B.B.D. Bag South, Kolkata - 700001
Shifting of 500 KVA transformer no.2 from CT box to the old Sub Stn. Room and allied works at Alipore TF, Kolkata
2023_BSNL_156738_1
32/TED-II/Kol/23-24
Open Tender
Electrical Works
Item Rate
10 days
TF Alipore
As per tender document
4 documents required · 4 mandatory
₹590
Yes
Accounts Officer(Cash), BSNL, O/O the GMT CAL SSA
₹4,964
Yes
O/o EE(E),ED-II,Kol
4 Aug 2023
8 Jun 2023
19 Jun 2023
8 Jun 2023
17 Jun 2023
8 Jun 2023
8 Jun 2023 - 17 Jun 2023
15 Jun 2023
Amount
Checking, testing and dismentling of faulty 500 KVA, 6.6 KV / 415 V transformer No. 1 of old sub stn after disconnecting the LT side 3 nos 3½ X 240 sq. mm PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade and HT Cable connection, neutral and body earth connection of said transformer and shifting to other place of old Sub stn house as instructed by site engineer etc. complete as reqd
Checking, testing and dismentling of 500 KVA, 6.6 KV / 415 V transformer No. 1 of CT box sub stn after disconnecting the LT side bus tranking connection and HT Cable connection, neutral and body earth connection of said transformer etc. complete as reqd
Shifting of 500 KVA, 6.6 KV / 415 Volt transformer from CT BOX to Old sub stn. of Alipore Telecom factory with the help of wooden sleeper, trochen jack etc. and placing of Faulty 500 KVA, 6.6 KV / 415 Volt transformer etc. complete as reqd.
Supplying and fixing of 25 x 5 mm copper strip for body and neutral earthing i/c fitting, fixing, connecting, testing, checking etc. complete as reqd.(approx-3.5 mtrs)
Supplying and fixing of LT side cable entry box maid out of 16 swg MS sheet (size: 500 x 450 x 235 mm) i/c fitting, fixing, testing, checking etc. complete as reqd.
Providing and fixing of 50 x 10 mm copper extention bar for cable connection of LT side of 500 KVA transformer i/c bending, drilling hole and also heat sink insulation covering the bar etc. complete as reqd.
Checking, testing of shifted 500 KVA, 6.6 KV / 415 Volt transformer from CT BOX connecting of HT cable, LT cables and neutral & body strip connection etc. and meggering and commissioning the the same etc. complete as reqd.
Supplying and fixing of cable entry box maid out of 16 swg MS sheet (size: 500 x 600 x 235 mm) i/c fitting, fixing, testing, checking etc. complete as reqd.(back side of 630 Amp. MCCB)
Supplying and fixing of 40 x 40 x 5 mm angle iron and 3 nos suitable size GI strip clamp i/c grouting the angle iron on the wall, cement plastering etc. complete as reqd.
Supplying and fixing of 400 Amp. TPN SFU with sheet steel enclosure and 3 nos 400 Amp. HRC fuse i/c fixing on the wall, connecting, testing, checking and commissioning etc. complete as reqd.
Supplying and fixing of cable entry box maid out of 16 swg MS sheet (size: 450 x 350 x 235 mm) for 400 Amp. SFU i/c fitting, fixing, testing, checking etc. complete as reqd.
Supplying and fixing of sheet steel enclosure with powder coating painting of 400 Amp. TPN SFU i/c fixing on the wall, connecting, testing, checking and commissioning etc. complete as reqd.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
a) Above 185 sq. mm and upto 400 sq. mm
b) Above 95 sq. mm and upto 185 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on existing cable tray as required.
a) Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
b) Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
a) 3½ X 185 sq. mm (57mm)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .