Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹43.4 LAccepted-AOC 2 10 PANCHANANTALA ROAD KOLKATA 700 041 | KOLKATA | WEST BENGAL | 700041 | L-1 | Accepted-AOC Being lowest bidder | |
| 2 | L-2₹44.7 L+₹1.3 L (3.04%)Rejected-Finance 3 IBRAHIM ROAD KHIDDERPORE KOLKATA 700023 | KOLKATA | WEST BENGAL | 700023 | L-2 | Rejected-Finance Other than lowest bidder | |
| 3 | L-3₹45.2 L+₹1.8 L (4.16%)Rejected-Finance | L-3 | Rejected-Finance Other than lowest bidder | |
| 4 | L-4₹45.7 L+₹2.3 L (5.36%)Rejected-Finance GC ROAD ABDUL LATIF ROAD PO TITAGARH KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | L-4 | Rejected-Finance Other than lowest bidder | |
| 5 | L-5₹46.3 L+₹2.9 L (6.59%)Rejected-Finance 7 11 1 BROJONATH LAHIRI BISHNUPUR SOUTH 24 PGS WEST BENGAL 743503 | 24 PARAGANAS SOUTH | WEST BENGAL | 743503 | L-5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | BHASKAR SUPPLY AGENCY L6 | KWALITY CONSTRUCTION L4 | MS AP CONSTRUTION AND CO L7 | EASTERN REFRIGERATION AND ELECTRICAL CO L2 | RADHA ENTERPRISE L8 | SK CONSTRUCTION SYNDICATE & ENGG CO L5 | PINKY CO. L3 | ARATI TRADING CO L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Design, supply, erection, testing and commissioning of indoor type power distribution panel of overall size not less than 1850mm width x 1700mm Height x 400mm depth, M.S. Channel Base Frame (to be mounted on the 3 side covered brick pedestal of height 300mm above floor level) suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos aluminium bus bars of rating 600 amps, Provision of Spreader link to incoming / outgoing side of MCCBs for termination of cables / busbars and FRP / DMC Cable connectors for termination of outgoing cables from pump starters / MCBs.The Panel shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of panel boards and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-54 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 2.00mm thick CRCA mild steel sheet and 2.00mm thick gland plate and having compartmentalized construction for individual switchgears / Pump Starters and Bus Bars and having front and rear opening facility and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The panel shall be comprising of the followings :- | 1 | Each Job | 4,72,000 ₹4,72,000 | 51,502 ₹51,502 Lowest | 4,44,000 ₹4,44,000 | 4,25,000 ₹4,25,000 | 4,55,000 ₹4,55,000 | 4,18,000 ₹4,18,000 | 4,50,000 ₹4,50,000 | 4,25,000 ₹4,25,000 |
| 1.01(a) Panel mounted Front operated type ON Load Change over switch with rotary handle suitable for 415 Volts, 50 Hz supply and capacity 400 Amps 4 Pole - 01 Nos. Make HAVELLS (Euroload) / LAURITZ KNUDSEN / HPL(Socomec) b) Incomer MCCB 4 Pole, 400 Amps, 36 KA with rotary handle (adjustable thermal 100% - 80% - 02 Nos (Make : LEGRAND / L&T / SCHNEIDER/H/HAVELLS) c) Outgoing MCCB 4 Pole, 325 Amps,36 KA with rotary handle (adjustable thermal 100% - 80% - 01 No. (Make : LEGRAND / L&T / SCHNEIDER/HAVELLS) d) Outgoing MCCB 4 Pole, 200A Amps,36 KA with rotary handle (adjustable thermal 100% - 80% - 01 Nos. (Make : LEGRAND / L&T / SCHNEIDER/HAVELLS) e) Outgoing MCCB 4 Pole, 160A Amps,25 KA with rotary handle (adjustable thermal 100% - 80% - 03 Nos. (Make : LEGRAND / L&T / SCHNEIDER/HAVELLS) f) Digital Voltmeter (96mm x 96mm) 4.5 digit with accuracy class 1 - 01 No (AE / RISHABH / L&T / CONZERV) | |||||||||||
| 1.02g) Volt Meter selector switch 6 amps (3 position + OFF) - 01 No (KAYCEE / L&T / SG) h) Digital Ammeter(96mm x 96mm) - 01 No (with 3 Nos CT 250/5) (AE / RISHABH / L&T / CONZERV) j) Ammeter selector switch 6 amps (3 position + OFF) - 01 No (KAYCEE / L&T / SG) k) CT having ratio 400/5, tape wount, BPL rated burden 05 VA - 03 Nos (Kappa/L&T/ RISHABH/C&S) l) LED indicator lamp, 22mm with cluster LED (Red-Yellow-Blue) - 01 Set (L&T / RAAS / TEKNIK / ESSEN) m) Bakellite cable connector 4 way (32 / 63 Amps) - 08 Nos (ACDC / RAMANUJ) Power & Control Wiring : (i) All Power Wiring from bus bar to outgoing MCCBs Upto 100 Amps shall be carried out by Gray coloured 1100 volt grade single core multiflexible type copper wire of nominal cross sectional area 35.0 sqmm and for 160 amps MCCB with 70.0 sqmm,400 A MCCB with 90.0 sqmm copper wire or suitable size Cupper strip duly insulated with coloured heat shrink type PVC sleeve. (ii) All Control Wiring for Metering / LED Indicators shall be carried out by Gray coloured 1100 volt grade single core multiflexible type copper wire of nominal cross sectional area 1.5 sqmm with MCB protection.. Cable Entry / Exit All the cable entry / exit shall be throgh bottom . Suitable size gland plate shall be provided for that purpose. Note : Drawing of panel board shall have to be got approved from Engineer-in-Charge before placing of order for fabrication work. Location : Block 19 of Turf View | |||||||||||
| 2.00 | Design, supply, erection, testing and commissioning of outdoor type LT Feeder Pillar of overall size not less than 1400 mm Height (Without Canopy & Base Channel)x 1450 mm width x 350 mm Depth, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick / PCC. pedestal of height 450 mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 400 amps, Provision of Spreader link to both incoming and outgoing side of MCCBs for termination of cables. The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-54 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.15mm thick CRCA Stainless steel sheet for outer shell & canopy and 2.0mm thick for inner doors / partations and 3.15mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility with double layer shutter and rear opening facility with single layer shutter with locking facility and 4 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :- | 1 | Each Job | 3,17,000 ₹3,17,000 | 3,90,000 ₹3,90,000 | 2,98,000 ₹2,98,000 | 2,76,000 ₹2,76,000 | 3,19,000 ₹3,19,000 | 3,20,000 ₹3,20,000 | 2,75,000 ₹2,75,000 Lowest | 3,10,000 ₹3,10,000 |
| 2.01PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables. BUS BARS & INTERNAL CONNECTIONS :- The bus bars should be made of Aluminium, duly insulated with 1100 volts grade standard colour coded heat shrink type PVC sleeves and rigidly mounted on suitable size 'F' class insulators of non hygroscopic non combustable, track resistant,high strength FRP / SMC / DMC material. 4 Nos Aluminium bus bars of rating 400 amps, . For all internal connections from main bus bars to switch gears shall be carried out with suitable size 1100 v grade PVC insulated copper wire as per the current carrying capacity of individual switch gears. Earthing bar shall be provided as per standard practice and shall be made of Galvanized Steel flats of size 25mm x 6 mm CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLSH grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges. INCOMING :- MCCB 250 Amps (25 KA) 4 Pole Adjustabble thermal (80% to 100%) and fixed magnetic protection -01 No | |||||||||||
| 2.02OUTGOINGS :- (a) Outgoing MCCB 4 Pole, 160 Amps,16 KA with rotary handle (adjustable thermal 100% - 80% - 04 No. (Make : LEGRAND / L&T / SCHNEIDER/HAVELLS) d) Outgoing MCCB 4 Pole, 125A Amps,16 KA with rotary handle (adjustable thermal 100% - 80% - 03 Nos. (Make : LEGRAND / L&T / SCHNEIDER/HAVELLS) e) Digital Voltmeter (96mm x 96mm) 4.5 digit with accuracy class 1 - 01 No (AE / RISHABH / L&T / CONZERV) f) Volt Meter selector switch 6 amps (3 position + OFF) - 01 No (KAYCEE / L&T / SG) g Digital Ammeter(96mm x 96mm) - 01 No (with 3 Nos CT 250/5) (AE / RISHABH / L&T / CONZERV) h) Ammeter selector switch 6 amps (3 position + OFF) - 01 No (KAYCEE / L&T / SG) j) CT having ratio 250/5, tape wount, BPL rated burden 05 VA - 03 Nos (Kappa/L&T/ RISHABH/C&S) (vi) Aluminium bus bar 4 Nos suitable for current rating 400 Amps duly mounted on FRP / DMC insulators - 01 Set a) LED Phase Indicating light, shrouded type, 22mm, with cluster LED - 07 set of 3 lamps (RED,YELLOW & BLUE) b) Danger Notice Plate duly written in Signal Red colour on Aluminium plate in English & Hindi language and of size not less than 150mm x 100mm - 02 Nos. | |||||||||||
| 2.03Note:- (a) All incoming & outgoing feeders to be marked with aluminium name plates duly rivetted on the front inner door of the feeder pillar. (b) All the cable entry / exit will be through bottom only, duly glanded with single compression type brass cable gland of suitable size. Cost of end termination of cable shall deemed to be included in the cost of feeder pillar. (c) All the inner / outer doors should have locking facility through castle locks (d) Cost of all civil work for brick pedestal, duly plastered, shall deemed to be included in the unit rate quoted, no separate payment shall be allowed for this. (e) The dimention of Panel Board as mentioned above is tentative. If it is required to be enhanced to accomodate the switchgears and maintaining the gaps as per IE Rules, it should be enhanced as per requirement without any extra cost to the department. (f)The thickness of MS Sheet for outer shell and canopy shall be of 3.0mm and inner doors and partitions shall be of 2.0 mm (g) The Panel Board should be designed in such a way that adequete workable space is made available inside every compartments. (h) The drawing of the Panel Board shall have to be got approved by Garrison Engineer before starting of fabrication process. Location : Near Pump House of Block 19 (TV) | |||||||||||
| 3.00 | Design, supply, erection, testing and commissioning of indoor type LT Panel of overall size not less than (1800 mm width x 1700mm Height x 450mm Depth), M.S. Channel Base Frame (to be mounted on the floor/brick wall through grouting bolt) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos cupper bus bars of rating 600 amps, Provision of Spreader link to incoming / outgoing side of MCCBs for termination of cables / busbars and extended cupper bars for termination of outgoing cables from MCCBs.The Panel shall be duly fabricated in an approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of panel boards and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-54 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 2.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front and rear opening facility and mild steel channel (MC-75) base frame at bottom, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The panel shall be comprising of the followings :- | 1 | Each Job | 4,45,000 ₹4,45,000 | 4,90,000 ₹4,90,000 | 4,45,000 ₹4,45,000 | 4,30,000 ₹4,30,000 Lowest | 4,60,000 ₹4,60,000 | 4,44,000 ₹4,44,000 | 4,35,000 ₹4,35,000 | 4,45,000 ₹4,45,000 |
| 3.01(a) Panel mounted Front operated type ON Load Change over switch with rotary handle suitable for 415 Volts, 50 Hz supply and capacity 400 Amps 4 Pole - 01 Nos. Make HAVELLS (Euroload) / LAURITZ KNUDSEN / HPL(Socomec) b) Incomer MCCB 4 Pole, 400 Amps, 36 KA with rotary handle (adjustable thermal 100% - 80% - 02 Nos (Make : LEGRAND / L&T / SCHNEIDER/H/HAVELLS) c) Outgoing MCCB 4 Pole, 200 Amps,25 KA with rotary handle (adjustable thermal 100% - 80% - 03 No. (GE office Panel & Senapati Bhawan Feeder) (Make : LEGRAND / L&T / SCHNEIDER/HAVELLS) d) Outgoing MCCB 4 Pole, 160A Amps,25 KA with rotary handle (adjustable thermal 100% - 80% - 03 Nos. (Make : LEGRAND / L&T / SCHNEIDER/HAVELLS) e) Digital Voltmeter (96mm x 96mm) 4.5 digit with accuracy class 1 - 01 No (AE / RISHABH / L&T / CONZERV) f) Volt Meter selector switch 6 amps (3 position + OFF) - 01 No (KAYCEE / L&T / SG) g Digital Ammeter(96mm x 96mm) - 01 No (with 3 Nos CT 250/5) (AE / RISHABH / L&T / CONZERV) h) Ammeter selector switch 6 amps (3 position + OFF) - 01 No (KAYCEE / L&T / SG) j) CT having ratio 400/5, tape wount, BPL rated burden 05 VA - 03 Nos (Kappa/L&T/ RISHABH/C&S) | |||||||||||
| 3.02j) LED indicator lamp, 22mm with cluster LED (Red-Yellow-Blue) - 01 Set (L&T / RAAS / TEKNIK / ESSEN) o) Bakellite cable connector 4 way (32 / 63 Amps) - 06 Nos (ACDC / RAMANUJ) Power & Control Wiring : (i) All Power Wiring from bus bar to outgoing MCCBs Upto 100 Amps shall be carried out by Gray coloured 1100 volt grade single core multiflexible type copper wire of nominal cross sectional area 35.0 sqmm and for 160 amps MCCB with 70.0 sqmm,400 A MCCB with 90.0 sqmm copper wire or suitable size Cupper strip duly insulated with coloured heat shrink type PVC sleeve. (ii) All Control Wiring for Metering / LED Indicators shall be carried out by Gray coloured 1100 volt grade single core multiflexible type copper wire of nominal cross sectional area 1.5 sqmm with MCB protection.. Cable Entry / Exit All the cable entry / exit shall be throgh bottom . Suitable size gland plate shall be provided for that purpose. Note : Drawing of panel board shall have to be got approved from Engineer-in-Charge before placing of order for fabrication work. Location : DG ROOM PANEL OF IMH COMPLEX | |||||||||||
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
13 Sept 2025, 6:00 pmClosed
Garrison Engineer Alipore
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
REPAIR/ RENEWAL and MAINTENANCE TO SUB-STATION LT PANEL, LT CABLE and CONNECTED ACCESSORIES AT TURF VIEW AND IMH COMPLEX UNDER GE ALIPORE KOLKATA
2025_MES_727502_1
GE/ALP (8534) KOLKATA OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Alipore Kolkata
Class D category b (i)
9 documents required · 9 mandatory
₹500
Garrison Engineer Alipore
₹84,000
Yes
GE Alipore Kolkata
18 Nov 2025
23 Aug 2025
20 Sept 2025
23 Aug 2025
13 Sept 2025
6 Sept 2025
23 Aug 2025 - 30 Aug 2025
1 Sept 2025
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .