Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹60.0 L
EMD Value
₹1.2 L
Closing Date
22 Oct 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Exexutive Engineer (E), BED, Prayagraj
Exexutive Engineer (E), BED, Prayagraj
Providing, Installation, Testing and commissioning of firefighting with Wet riser System in CTO Admin building (Gand6) Floor and Micro Wave technical building (G and 3) Floor at Prayagraj (UP). (2nd Call)
2026_BSNL_292841_1
09/ATC/GEM/BSNL/ED/PRYJ/26-27
Open Tender
Electrical Works
Item Rate
180 days
Prayagraj
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹1.2 L
Yes
30 Sept 2026
30 Sept 2026
23 Oct 2026
30 Sept 2026
22 Oct 2026
30 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1SH-1 ( Wet Riser System) | |||||
| 2Main Fire Pump | |||||
| 3a) Supplying, installation, testing and commissioning of Electric driven Main Fire Pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, fire pump capable for delivery of 2280 LPM against atotal head of 70 Mtrs (Approximately) while running at 1450/1500 rpm mechanical seal as required BSNL approved make. c) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-12615: 2018. d) M.S. fabricated Common base plate, coupling,coupling guard, foundation bolts etc. as required. e) Suitable cement concrete foundation duly plastered with anti vibration pads Note: *The head of the pump is selected in a manner so as to give a minimum 3.5kgf /cm2 pressure at the highest/farthest point. **The pump room is situated on the underground water tank. | |||||
| 3.01 | 2280 lpm at 70 m Head | 1 | No | - | - |
| 4(Diesel Driven Pump) | |||||
| 5a) Supplying, installation, testing and commissioning of die sel engine driven main fire pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) (b) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze peller with stainless steel shaft, mechanical seal suitable to delivering 2280 LPM against atoatl head of 70 Mtrs ( Approxi) as required. (c) Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. (d) M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. (e) Suitable cement concrete foundation duly plastered and with anti vibration pads Note: * The head of the pump is selected in a manner so as to give a minimum 3.5kgf /cm2 pressure at the highest/farthest point. **The pump room is situated on the underground water tank. | |||||
| 5.01 | 2280 lpm at 70 m Head | 1 | No | - | - |
| 6Jockey Pump | |||||
| 7(a) Supplying, installation, testing and commissioning of electric driven pressurisation pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) (b)Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal as required. (c)Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class 'F' insulation, conforming to IS-12615: 2018. (d)M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (e) Suitable cement concrete foundation duly plastered and with anti vibration pads. Note: *The pump room is situated on the underground water tank. | |||||
| 7.01 | 180 lpm at 70 m Head | 1 | No | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.08 MB
GeMBidding-.pdf
Tender Documents • 0.52 MB
BOQ_341434.xls
BOQ • 0.52 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .