| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.7 CrAccepted-AOC A 1 409 MADHU VIHAR NEAR SEC 3 PKT 16 DWARKA NEW DELHI DELHI 110059 INDIA UDYAM DL 10 0026465 | WEST DELHI | DELHI | 110059 | ₹1.7 Cr Quoted ₹1.8 Cr | L-1 | Accepted-AOC Become L-1 |
| 2 | L-2₹1.9 Cr+₹12.1 L (6.89%)Rejected-Finance 218 2ND FLOOR U S COMPLEX 120 MATHURA ROAD NEW DELHI 110076 | SOUTH | DELHI | 110076 | ₹1.9 Cr+₹12.1 L (6.89%) | L-2 | Rejected-Finance Become L -2 |
| 3 | L-3₹1.9 Cr+₹15.1 L (8.61%)Rejected-Finance | ₹1.9 Cr+₹15.1 L (8.61%) | L-3 | Rejected-Finance Become L -3 |
| 4 | L-4₹2.0 Cr+₹29.3 L (16.8%)Rejected-Finance | ₹2.0 Cr+₹29.3 L (16.8%) | L-4 | Rejected-Finance Become L -4 |
| 5 | L-5₹2.2 Cr+₹41.2 L (23.6%)Rejected-Finance 2 44 A 4 KALU SARAI HAUZ KHAS DELHI SOUTH WEST DELHI DELHI 110016 | SOUTH DELHI | DELHI | 110016 | ₹2.2 Cr+₹41.2 L (23.6%) | L-5 | Rejected-Finance Become L -5 |
Tender Value
₹2.6 Cr
EMD Value
₹5.2 L
Closing Date
9 Nov 2022, 6:00 pmClosed
AGM(E-E)
O/o AGM (E-E), Safdarjung Airport
Running operation and maintenance of pump set, Int. and Ext. Electrical installations of INA Residential Colony Pocket- A and B, Guest House, Medical Centre etc. at Safdarjung Airport, New Delhi. (for the year of 2022-24).
2022_AAI_131767_1
AAI/SAP/Engg(E)/ARMO -INA/2022-23
Open Tender
Electrical Works
Works
730 days
Safdarjung Airport
Please refer Tender Document.
15 documents required · 15 mandatory
₹1,180
₹5.2 L
28 Jul 2025
17 Oct 2022
11 Nov 2022
18 Oct 2022
9 Nov 2022
18 Oct 2022
18 Oct 2022 - 25 Oct 2022
Amount
SH-I- Operation & maintenance
Running operation and maintenance of Internal and External Electrical installations, water supply pumps and DG sets etc. at INA colony pocket A & B, Guest House, Medical Centre etc, i/c on all working days i/c Saturdays, Sundays, Gazetted holidays & National holidays i/c carrying out routine preventive/ breakdown maintenance and record keeping etc. by deploying the following minimum man power as per specification, terms and conditions of tender document complete as required for one month in shift basis (round the clock) as per the requirement of works. The agency has to quote the rate in conformity with para no. 12 of special condition of contract. Note: Supervisor is required to be deployed on all working days i/c Saturdays, Gazetted holidays & National holidays except Sundays and for Data entry operator required to be deployed on all working days i/c Saturdays & Gazetted holidays except Sundays & National holidays. i) Supervisor – 1 ii) Data Entry Operator (Highly Skilled) – 1 iii) Wireman (Skilled) – 7 iv) Wireman cum DG operator (Skilled) - 6 v) Pump Operator (Skilled) – 03 vi) Khallasi (Unskilled) – 14
SH-II: Miscellaneous minor repair works for E&M installations, as per specification, as & when required with prior approval of Engineer in charge.
Complete servicing of different type & model ceiling fans i/c greasing, replacement of cotter pin, rubber bush, bolts & nuts i/c dismantling, reinstallation of fan at the existing location as reqd.(excluding replacement of bearing )
Painting of following installations in position with synthetic enamelled paint by spray/ brush painting by one or more coats including scraping, cleaning of surface & writing actual nomenclature with highlighted colour on the installation after painting etc.
Distribution boards /out door panel/ Feedar piller etc.
Post top poles single /double Arms, height up to 4 mtr
Street light pole height upto 7 to 9 mtrs
Labour charges for lowering & lifting i/c dismantling of different sizes submersible pump set/ jet assembly alongwith pipe lines, cable from the existing bore, as & when reqd. re-installing back of the same i/c cost of cable joint & minor items such as nut bolt & rubber packing etc. (charges for repairing or rectification of fault of pump/ motor will be paid separately).
Providing & replacement of top and bottom bearing / bush of ceiling fans i/c associated work as per the requirment of following fans i/c dismantling and reinstallation of fan with testing, commissioning etc.as reqd.(Dismantled material shall be the property of tenderer)
Light weight ceiling fan/ Exhaust fan
Medium weight ceiling fan
12" Exhaust fan
Providing and replacement of damage/ rusted GI pipe line of submersible/ monoblock pump set, as & when reqd. with following size i/c threading cutting and accessories such as flange, socket, gasket, nut - bolts, washer etc. as reqd. I/c transportation to site of work.( make: Tata/Jindal)
2" dia GI 'B' class Pipe
3" dia GI 'B' class Pipe
Providing and fixing wood wool pads (1 set of 3 nos.) of good quality of suitable size for 4000 cum/hr capacity desert cooler at different locations & floors i/c dismantling, existing pads if reqd.
Rewinding of the following ceiling fan, desert cooler motors etc i/c dismantling, transportation to workshop & back i/c connection, testing & commissioning as reqd. (Dismantled material shall be the property of tenderer)
Ceiling fan of all makes and models.
Desert cooler fan motor of all makes and models.
Exhaust Fan of all makes & model up to 300mm.
Exhaust Fan of all makes & model of size more then 300mm & up to 450mm.
Rewinding of the following water pump motors and replacement of Bearing , bushes, water seal of pump motors etc i/c dismantling, transportation to workshop & back i/c connection, testing & commissioning as reqd. (Dismantled material shall be the property of tenderer)
12.5 HP, 3-Phase, Monoset Openwell pump
7.5 HP, 3- Phase, Monoblock/ booster pump set
5 to 6 HP, 3- Phase, Submersible pump set
Repairing of following capacity of submersible/ monoblock water supply pumps & replacement of all required unserviceable parts such as discharge bowl/ discharge bearing, intermediate bowl/ impeller/ upthrust collar/ intermediate ball bearing/ pump shaft/ Suction inlet/ suction adapter/ pump motor coupling / water seal /rotor polishing & tuning of rotor etc i/c lathe work, dismantling, transportation to workshop & back and reinstallation i/c testing & commissioning as reqd. (Dismantled material shall be the property of tenderer)
12.5 HP, 3-Phase, Monoset Openwell pump
5 to 6 HP, 3-Phase submersible pump set
7.5 HP, 3- Phase Monoblock/ booster pump set
Detection of LT cable fault by using LT cable fault locator machine on the route of cable laying at site & locate the fault at pin-pointing i/c excavation of soil etc as required.
SH-III- Supply of the following items as per specifications & reqired Makes, as and when required with prior approval of engineer in charge.
36 watt Electronic Ballast suitable for 36 watt FTL. (Make: Havells or equivalent)
36 watt fluorescent tube light.
36/40 Watt FTL Starter. (Make: Universal/Bajaj/ Philiphs/Havells)
1x36/40 W FTL fixture with domestic electronic ballast (without lamp).
Supply of 40 Amp double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA. (Make: L&T or equivalent)
Supplying of following rating, 240/415 V, 10 kA, "C" curve miniature circuit breaker (MCB):- (Make: L&T or equivalent)
6 A to 32 A, SP MCB.
32 Amp., DP MCB.
40 Amp., DP MCB.
63 Amp., DP MCB.
100 Amp., DP MCB.
Providing of following rating, breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders:- (Make: L&T or equivalent)
63 Amp., 25 KA,4 Pole MCCB.
125 Amp,36 KA ,4 Pole MCCB.
160 Amp,36 KA,4 Pole MCCB.
250 Amp.,36 KA 4 Pole MCCB.
Supplying of following piano type switch/ socket:-
5/6 amps switch. (Make: Anchor or equivalent)
5/6 Amps. Bell push switch. (Make: Anchor or equivalent)
15/16 A switch. (Make: Anchor or equivalent)
3 pin 5/6 A socket outlet. (Make: Anchor or equivalent)
6 pin 15/16 A socket outlet. (Make: Anchor or equivalent)
Supplying following modular switch/ socket:-
10A switch. (Make: Anchor or equivalent)
10A Bell push switch. (Make: Anchor or equivalent)
20A switch. (Make: Anchor or equivalent)
3 pin 5/6A socket outlet. (Make: Anchor or equivalent)
6 pin 15/16A Shuttered socket outlet. (Make: Anchor or equivalent)
Door bell ding-dong suitable to operate at 220-240 volt ,50 Hz. (Make: Anchor or equivalent)
6/16 Amp plate type switch socket assembly (Without box). (Make: Anchor or equivalent)
Supply of 6/16 Amp SS combine shutter type with box and fixing holes. (Make: Anchor or equivalent)
3 pin ,15/16 Amps Plug top. (Make: Anchor or equivalent)
12 watt surface mounted round type LED down lighter fitting with IP-54.
7 to 9 watt LED bulb (pin type).
20W (±10%) T8 4 feet LED tube light rod
20W (±10%) T8 4 feet LED tube light fitting (i/c batten & tube rod)
Supply of 12 volt , 25 plate 180 AH storage type lead acid battery etc as reqd. (as and when required). (Make: Exide, Model: Xpress or equivalent)
Battery water (Pack of 5 Ltrs.). (Make: Exide, Model: Distillo or equivalent)
Batten holder (Polycarbonate). (Make: Anchor or equivalent)
100 Watt Stepped type Fan regulator (1 module), suitable to operate at 220-240 volt, 50 Hz. (Make: Anchor or equivalent)
100 Watt Stepped type fan regulator (2 module), suitable to operate at 220-240 volt, 50 Hz. (Make: Anchor or equivalent)
100 Watt Stepped type Modular Fan regulator (1 module), suitable to operate at 220-240 volt, 50 Hz. (Make: Anchor or equivalent)
100 Watt Stepped type Modular Fan regulator (2 module), suitable to operate at 220-240 volt, 50 Hz. (Make: Anchor or equivalent)
5/6 Amp, Four outlet socket power strip with fuse protection , switch and having extension cord of minimum 1.5 mtrs. (Make: Anchor or equivalent)
15/16 Amp, Four outlet socket power strip with fuse protection , switch and having extension cord of minimum 1.5 mtrs. Cord. (Make: Anchor or equivalent)
Supply of capacitor of following rating:- (Make: Havells or equivalent)
1.75 MFD Capacitor.
2.5 MFD Capacitor.
18 watt submersible pump for Desert Cooler suitable to operate at 220-240 volt ,50 Hz. (Make: Khaitan Zolta or equivalent)
Supply of FR-LSH,PVC insulated single core, industrial grade copper conductor (Unsheathed) flexible cables,1100 Volts confirming to IS-694:-
1.5 Sqmm (90 mtr. length).
2.5 Sqmm (90 mtr. length).
4.0 Sqmm (90 mtr. length).
6.0 Sqmm (90 mtr. length).
Supply of PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694:-
3 core , 1.5 sq mm cable (100 Mtr).
3 core , 2.5 sq mm cable (100 Mtr).
Supply of flat 3 core 4 sq mm (100 Mtr) PVC insulated and PVC sheathed industrial or submersible pump motor cable, 1100 volts, confirming to IS 694
Supply of following sizes of 1.1kv grade multicore Aluminium conductor XLPE insulated PVC sheathed armoured cable (as per IS : 7098:1988 with upto date amendments) complete as requried as per specifications:-
2x6 sq.mm.
2x10 sq.mm.
3.5 core, 35 Sqmm, Aluminium cable
3.5 core, 95 Sqmm, Aluminium cable
3.5 core, 150 Sqmm, Aluminium cable
PVC Gang Box for the following switches / Sockets:-
1 no. 5 Amp switch. (Make: Anchor or equivalent)
1 no. 5 Amp switch & 1 no. 5 Amp socket. (Make: Anchor or equivalent)
2 no. 5 Amp switch & 2 no. 5 Amp socket. (Make: Anchor or equivalent)
PVC Channel of ISI marked heavy duty 1.6 mm thick of following sizes (one channel of 2 mtr. Length):- (Make: AKG or equivalent)
Twin Twisted Flexible copper wire 23/76 (90 mtr length).
Supplying and fixing of phenolic laminated sheet cover on existing metal box of following sizes (nominal size) on surface or in recess with suitable size as required.
125 mm X 125 mm
200 mm X 125 mm
275 mm X 175 mm
Industrial plug Top 3 Pin, 20 amp. (Make: Anchor or equivalent)
Industrial Socket 3 Pin, 20 amp. (Make: Anchor or equivalent)
3P MNX 32 power contactor. (Make: L&T or equivalent)
Overload relay:- (Make: L&T or equivalent)
Relay range 6-10 amp.
Relay range 9-15 amp.
Relay range 14-23 amp.
Single Phase Preventor. (Make: L&T or equivalent)
Star Delta Starter for 12.5HP 3Phase motor. (Make: L&T or equivalent)
SS Cordless 1.2 Litres Electric Kettle. (Make: Bajaj or equivalent)
Heat Convector of 2000W suitable to operate at 220-240V, 50Hz. (Make: Havells/ Bajaj or equivalent)
Room Heater (oil type) having 11 wave fins, 2900W with fan ,suitable to operate at 220-240V, 50Hz. (Make: Havells/ Bajaj or equivalent)
Room Heater of 800W having double rod suitable to operate at 220-240V, 50Hz. (Make: Havells/ Bajaj or equivalent)
15 Litre capacity vertical type water heater, rated power 2KW, suitable to operate at 220-240V, 50Hz, (Geyser). (Make: Havells Model: MONZA DX or equivalent)
Ceiling Fan of size 1200mm sweep including all accessories, suitable to operate at 220-240V,50Hz. (Make: Havells, Model: Velocity or equivalent)
Wall Fan having 400mm sweep,suitable to operate at 220-240V, 50Hz. (Make: Havells, Model: Swing or equivalent)
Pedestal Fan 450mm sweep,suitable to operate at 220-240V, 50Hz. (Make: Havells, Model: Sprint Hi-Speed or equivalent)
Exhaust fan having 200mm sweep, Non metallic body suitable to operate at 220-240V, 50Hz. (Make: Havells, Model: Ventil Air DX White or equivalent)
Exhaust Fan , 300 mm sweep, 1300-1400 rpm, heavy duty type, metal body,suitable to operate at 220-240V, 50Hz. (Make: Havells, Model: Turbo Force SP or equivalent)
SH-IV Misc. Electrical Works
CIS GLOBAL INFRATECH PRIVATE LIMITED
ANAND AND COMPANTY
SRS ENGINEERS
SWASTIK ELECTROTECH PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .