Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.5 LAccepted-AOC 11 A KUTCHERY ROAD BALUGANJ AGRA 282001 UP | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹49.7 L+₹18,467 (0.37%)Rejected-AOC 64 A JASRAJ MANSION 1ST FLOOR OLD HANUMAN LANE KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹50.0 L+₹53,002.25 (1.07%)Rejected-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹50.7 L+₹1.2 L (2.46%)Rejected-AOC SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L4 | Rejected-AOC NOT LOWEST | |
| 5 | Rejected-Technical 1446 ELITE ENTERPRISES NORTH SOLAPUR NEAR SUSHIL MARATHI SCHOOL SOLAPUR MAHARASHTRA 413004 | SOLAPUR | MAHARASHTRA | 413004 | - | Rejected-Technical As per Para 7 of NIT of the subject tender scan copy of DD with application uploaded but hard copy not recd by this office till date. Hence, It is recommended that T Bid to be rejected and Seven days will be given to rectify the deficiency |
Tender Value
₹45.3 L
EMD Value
₹90,600
Closing Date
3 Nov 2023, 6:00 pmClosed
GE (NW) MANKHURD
GE (NW) MANKHURD MUMBAI-88
ADDN/ALTN AND SPL REPAIRS TO DEF/BURNOUT ELECT PDBs INCL POWER DISTR CABLES AT THANE AND SPL REPAIRS TO BER ELECT APPLIANCES AND PROVN OF POWER SUPPLY FOR AC UNITS INCL SUMMER COOLING APPLIANCES AT TANAJI UNDER GE (NW) MANKHURD
2023_MES_623782_1
8261/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (NW) MANKHURD
AS PER NIT AND TENDER DOCUMENTs
9 documents required · 9 mandatory
₹500
GE (NW) MANKHURD
₹90,600
27 Jan 2024
18 Oct 2023
4 Nov 2023
18 Oct 2023
3 Nov 2023
24 Oct 2023
Amount
Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed.
Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
M & L for sand cushioning by spreading in trenches crushed sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge. Note : Sand after punning down will be measured
M & L for sand cushioning by spreading in trenches crushed sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge.
Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250 mm x 150 mm x 40 mm laid in trenches all as specified. Make - MEHTAB/ NATIONAL TILES
Supply and Laying or fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 25 Sqmm 3.5 core including necessary connection and providing cable lugs as required all as specified.
S& F of HDPE pipe 100mm dia for laying in ground, road crossing etc for cable protection including necessary fittings , clamps for supports, etc all as directed. Make - PRAYAG/ SUDHAKAR
S& F of HDPE type pipe, PN-10, 50 mm dia for laying in ground, road crossing etc for cabe protection including necessary fittings for wall and ducting with required clamps and supports, etc all as directed by Engineer in charge. Note : Required Clamps and supports shall be fixed on wall with distance 1.00 RM as directed by Engr-in-Charge.
M&L for cutting existing road/hard standing not exc 45x60 cm in wide & depth getting out excavated material for laying of cable returning filling & well rammaing watering finish suraface 10 cm from top including provision of PCC 1:3:6 for repairing, including removal of surplase soil all as directed
M&L for cutting existing road/hard, dense soil not exc 45x45 cm in wide & depth getting out excavated material for laying GI tube returning filling & well ramming watering finish suraface 10 cm from top using PCC 1:3:6; of not less than 4 inch including removal of surplase soil all as directed
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 4 Core including taking down of old u/s cable complete all as specified. Make - KEI/ Polycab/ Universal/ Havells
All as per Item No 8 herein before but of size 35 Sqmm 3.5 Core complete all as specified. Make - KEI/ Polycab/ Universal/ Havells
All as per Item No 8 herein before but of size 150 Sqmm 3.5 Core complete all as specified. Make - KEI/ Polycab/ Universal/ Havells
All as per Item No 8 herein before but of size 240 Sqmm 3.5 Core complete all as specified. Make - KEI/ Polycab/ Universal/ Havells
All as per Item No 8 herein before but of size 300 Sqmm 3.5 Core complete all as specified. Make - KEI/ Polycab/ Universal/ Havells
Supply and fix 4 core 2.5 sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade ISI marked complete all as specified and directed.
S&F Cable jointing kit for 11 KV (Earthed) grade cable for indoor End termination Heat shrink type joint complete with jointing material and accessories suitable for 3/ 3.5 core XLPE armoured aluminium conductor cable of size 240 Sqmm to 300 Sqmm complete all as specified and directed. Make - DENSON/ 3M/ REYCHEM
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 400 sqmm complete all as specified and directed. Make - DENSON/ 3M/ REYCHEM
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed. Make - DENSON/ 3M/ REYCHEM
M&L for earthing complete with GI earth plate electrode 600x 600x 3 mm buried directly in ground with top edge of the plate not less than 1.5 mtrs below normal gound level and connected to earth test point by means of GI Strip of size 32x6 mm all as specified and shown in electric plate No 3 of MES SSR Part-I 2009 including earthwork, PCC chamber, CI cover, protection and watering pipe, funnel, mesh etc all as required at site and all as directed. Note: (1). 7.5 RM GI strip in deemed to be included in quoted rates beyond 7.5 RM strip shall be measured and paid separately (2) Rate quoted by the tenderer is deemed to include salt & Charcoal upto & above 450 mm top of GI earth plate.
M&L for earthing using galvanised earth lead wire 4.0 mm dia complete with galvanised steel earth plate electode 600mmx600mmx6mm thick buried directly in ground, earth pit not less than 2.25 meters deep below ground level connection to and including GI strip of size 32x6mm to the extend 7.5 mtr as earth lead by means of GI bolts, Nuts etc. with provision of charcoal and salt all as per electrical plate No 3 of SSR Part I including water arrangement with GI Pipe 20 MM dia (medium Grade), earth lead protection pipe 50mm madium grade with bends, elbow etc. from earth plate to test point, excavation and earth work returning, filling, ramming and removing of soil to distance not exc 50mtr, make good to match with existing surface making PCC pit (Earth chamber) having internal size 30cm x 30cm x 30cm and outer size 60cm x 60cm x 60cm with RCC reinforced cover 50mm thick with one lifting handle made of 8mm dia MS bar funnel wie mesh and testing on completion including making test point on wall as per SSR specification all as specified and directed. Note: (1). 7.5 RM Copper strip in deemed to be included in quoted rates beyond 7.5 RM strip shall be measured and paid separately (2). Earth resistance of earth pit should be less than 0.5 Ohms. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (3) Rate quoted by the tenderer is deemed to include salt & Charcoal upto & above 450 mm top of plate.
Supply and Fix fix GI strip 32 mm x 6 mm earth contunity conductor laid in ground or drawn in conduit pipe or fixed to polesor for loop earthing etc all as directed by Engg in Charge.
Supply& fixing in repairs of Chequered plate Fe 410-W(Gde-E- 250)A quality- for cable trenches, ladders including equal angle trench frames, including cutting as per requirement of site, square cut or notched (ordinary and counter sunk) forming holes, without any including providing handles
Supply& fixing in repairs for mild steel work confirming to Fe-290, GdeE-165 in stairs/ladders including stringes, treades, landing, balusters, hand rails etc including applying two coat of paint over one coat of red oxide complete all as specified and directed.
M & L for PCC 1:3:6, type C-2, (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for pcc 1:2:4 type B-1 using 20 mm graded stone agrregates as in pedestal of pole/ strut and in copping including necessary form work and finishing exposed faces of concrete even and smooth using extra cement all as directed by engineer in charge .
Supply & fix in repairs GI cable tray with cover of size 300 mm X 100 mm (Appx 2.0 mm) including spacers, screws, saddles for fixing the trunking in wall/GI sheets of shed complete all as specified and directed.
Supply install, testing and commissioning in renewal LT Power Distribution Board (CPRI Approved) indoor type Powder coated cubical type Indoor factory fabricated made out of 2 mm thick CRCA sheet & suitable for 3 Phase 4 wire 415 V, 50 Hz tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated in an approved factory having modern fabrication process powder coating in approved shade having thickness not less than 100 microns provided with suitable gasket to make it dust/ vermin proof & general construction confirming to IS : 8623/93 and size to accommodate all accessories/fittings, compartmentalized in construction to accommodate all accessories. The TPN bus bar shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval not more than 500 mm through out the length of the TPN bus bar. The Cubicle incomer MCCB as well as outgoing MCCBs shall have copper TPN extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coated sleeves. The cubicle shall have a bottom channel of size 50x50x6 mm duly coated with zinc metal coating having thickness not less than 100 microns. A detachable predrilled powder coated gland plate should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front and back openable lockable /openable by key from both sides having chromium plated 19mm dia fancy locks,louvers and air vent gasket for natural flow of air. The Panel shall be powder coated with pure polyster siemens grey structural RAL 7032 shade. The degree of protection of outer shell shall be IP-54. All control wires shall be with 2.5 sqmm multistrand copper conductors and shall be properly bunched, tied, ferruled for proper identification and crimped with adequate size of lugs. A detachable predrilled gland plate of thickness 2.0 mm powder coated should be used at the bottom. Adhesive type gasket shall be used to make panel vermin proof/ Dustproof Complete as specified and consisting the following :- Make of LT Panel - Lotus Power Gear Pvt Ltd/ Universal Switch Gear Control/ Power Switch Gear & Control/ Vidhyut Technologies India Pvt Ltd. or any CPRI approved manufacturer i) Electrolytic Copper Busbar TPN 1200 Amps -1 Set ii) Air Circuit Breaker, AC, 50 cycles, 3 phase, 4 Pole (Manual Draw Out Type) rated current rating 800 Amps and of breaking capacity 50 KA- 1 No (Incoming) Make - Legrand/ L&T/ C&S/ ABB iii) On load Changeover swtich 400 Amps FP, operating on 415 V, 50 Hz, AC supply complete - 2 No Make - L&T/ Legrand/C&S/ Schneider/ ABB iv) MCCB 400 Amp, 3 Pole, 415V, 50 Hz Icu50 KA (Ics = 75%Icu), Thermal magnetic type - 01 Nos (Outgoing) Make - L&T/ Legrand/C&S/ Schneider/ABB v) MCCB 320 Amp, 3 Pole, 415V, 50 Hz Icu36 KA (Ics = 75%Icu), Thermal magnetic type - 01 Nos (Outgoing) Make - L&T/ Legrand/C&S/ Schneider/ABB vi) MCCB 250 Amp, 3 Pole, 415V, 50 Hz Icu36 KA (Ics = 75%Icu), Thermal magnetic type - 03 Nos (Outgoing) Make - L&T/ Legrand/C&S/ Schneider/ABB vii) MCCB 200 Amp, 3 Pole, 415V, 50 Hz Icu36 KA (Ics = 75%Icu), Thermal magnetic type - 04 Nos (Outgoing) Make - L&T/ Legrand/C&S/ Schneider/ABB viii) MCCB 100 Amp, 3 Pole, 415V, 50 Hz Icu25 KA (Ics = 75%Icu), Thermal magnetic type - 02 Nos (Outgoing) Make - L&T/ Legrand/C&S/Schneider/ABB ix) MCB 32 Amp, 3 Pole, 415V, 50 Hz Icu16 KA (Ics = 75%Icu) - 02 Nos (Street light) Make - L&T/ Legrand/C&S/ Schneider/ABB x) MF Meter 4410 series -01 No Make - L&T/ C&S/ Schneider or equivalent xi) Indicating Lamps LED Type-03 Nos Make - L&T/ C&S/ Schneider or equivalent xii) Street Light Time switch, 16 Amps & 2 Pole Contactor 40 Amp - 1 No Make - L&T/ C&S/ Schneider or equivalent Note –: The Lay out drawing of the panel shall be got approved by the contractor from GE before the panel fabrication work.
Supply install, testing and commissioning in renewal LT Power Distribution Board (CPRI Approved) indoor type Powder coated cubical type Indoor factory fabricated made out of 2 mm thick CRCA sheet & suitable for 3 Phase 4 wire 415 V, 50 Hz tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated in an approved factory having modern fabrication process powder coating in approved shade having thickness not less than 100 microns provided with suitable gasket to make it dust/ vermin proof & general construction confirming to IS : 8623/93 and size to accommodate all accessories/fittings, compartmentalized in construction to accommodate all accessories. The TPN bus bar shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval not more than 500 mm through out the length of the TPN bus bar. The Cubicle incomer MCCB as well as outgoing MCCBs shall have copper TPN extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coated sleeves. The cubicle shall have a bottom channel of size 50x50x6 mm duly coated with zinc metal coating having thickness not less than 100 microns. A detachable predrilled powder coated gland plate should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front and back openable lockable /openable by key from both sides having chromium plated 19mm dia fancy locks,louvers and air vent gasket for natural flow of air. The Panel shall be powder coated with pure polyster siemens grey structural RAL 7032 shade. The degree of protection of outer shell shall be IP-54. All control wires shall be with 2.5 sqmm multistrand copper conductors and shall be properly bunched, tied, ferruled for proper identification and crimped with adequate size of lugs. A detachable predrilled gland plate of thickness 2.0 mm powder coated should be used at the bottom. Adhesive type gasket shall be used to make panel vermin proof/ Dustproof Complete as specified and consisting the following :- Make of LT Panel - Lotus Power Gear Pvt Ltd/ Universal Switch Gear Control/ Power Switch Gear & Control/ Vidhyut Technologies India Pvt Ltd. or any CPRI approved manufacturer i) Electrolytic Copper Busbar TPN 400 Amps -1 Set ii) On load Changeover swtich 250 Amp, 4 Pole, operating on 415 V, 50 Hz, AC supply complete -1 No Make - L&T/ Legrand/C&S/ Schneider/ ABB iii) MCCB 250 Amp, 3 Pole, 415V, 50 Hz Icu36 KA (Ics = 75%Icu), Thermal magnetic type - 01 Nos (Outgoing) Make - L&T/ Legrand/C&S/ Schneider/ABB iv) MCCB 200 Amp, 3 Pole, 415V, 50 Hz Icu36 KA (Ics = 75%Icu), Thermal magnetic type - 01 Nos (Outgoing) Make - L&T/ Legrand/C&S/ Schneider/ABB v) MCCB 100 Amp, 3 Pole, 415V, 50 Hz Icu25 KA (Ics = 75%Icu), Thermal magnetic type - 04 Nos (Outgoing) Make - L&T/ Legrand/C&S/ Schneider/ABB vi) MCCB 63 Amp, 3 Pole, 415V, 50 Hz Icu16 KA (Ics = 75%Icu), Thermal magnetic type - 03 Nos (Outgoing) Make - L&T/ Legrand/C&S/ Schneider/ABB vii) MCB 32 Amp, 3 Pole, 415V, 50 Hz Icu16 KA (Ics = 75%Icu) - 02 Nos (Street light) Make - L&T/ Legrand/C&S/ Schneider viii) MF Meter 4410 series -01 No ix) Indicating Lamps LED Type-03 Nos x) Street Light Time switch, 16 Amps & 2 Pole Contactor 40 Amp - 1 No Make - L&T/ C&S/ Schneider or equivalent Note –: The Lay out drawing of the panel shall be got approved by the contractor from GE before the panel fabrication work.
Supply and fixing ceiling fans complete with blades, down rods accessories etc operating with electronic regulator on 230 V, 1200 mm sweep. Min air delivery 210 CFM full load wattage 26 to 32 watts, High Speed conforming to IS 374 :2019, colour white BEE 5 star rated with brushless direct current motor (BLDC) without remote complete including taking down old unserviceable fan to MES store all as directed by Engr-in-Charge. Make : BAJAJ (Model : ENERGOS 28) / ORIENT (I FALCON) Note : Unserviceable ceiling fans shall be deposit to MES store.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW, 230V / 50Hz, Temperature Range 25 to 70 degree celcius & working pressure 0.8 Bar capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed. Make : AO SMITH / RACOLD / BAJAJ / JAQUAR Note : Contractor will give the warranty - 5 Years of Tank, 2 Years of Heating Element and 2 Years on Other Parts on Geyser supplied.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.20 of capacity 2 Ton electric driven single phase 230 Volt. Make :- Voltas/ LG/ Blue Star/ Carrier
S&F single pole and neutral enclosure with a two pin and earth and metal clad plug socket complete with one single pole MCB 20 Amp 240 Volts complete all as specified including concealing in wall and directed.
Supply & fixing for sub main wiring with two single core 4.0 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade down in through rigid flexible where applicable non metalic PVC casing caping with and including PVC insulated 4.0 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed including taking down of old sub main wiring Note : 1. Two runs of Single core cable, one run of earth wire & PVC Cassing Capping will be measured and paid one unit. Make - Havells/ Polycab/ KEI
Supply and fix copper tube of size 1/4" bore including brazing etc with rubberised insulation and tape suitable for supply pipes for air conditioners complete all as specified and directed.
Supply and fix copper tube of size 5/8" bore including brazing etc with rubberised insulation and tape suitable for supply pipes for air conditioners complete all as specified and directed.
Supply and fix PVC drain pipe of size 5/8" bore for supply pipes for air conditioners complete all as specified and directed.
Supply and fix Heavy duty Water Proof Powder coated mounting bracket for installation of outdoor unit of air condiioner made out of 2 mm thick high grade steel with suitable fastener, MS nuts, bolts M8 x 45mm, washer, bolt M8 x 30mm nut, bolts & washers etc. duly painted complete set all as specified and directed. Make :- Companion Sleek, Aircool Sales Corporation or equillant make.
Supply & fixing MCCB 4 Pole,415 V, fixed type, 125 Amps with breaking capacity 16 KA including connecting up electrically with proper lugs glands and including all necessary fittings complete all as specified and directed. Make -Havells/Indoasaian/Legrand/ABB/Schnider
S & F MCCB TPN DB, 4 way TPN (vertical type), double door, 415 Volts and including cutting chases in wall, concealing DB in wall, making good the disturbed surfaces and making all connections complete all as specified and directed. Note: Quoted rate shall be deemed to include for provision of copper bus bar of 200 Amps rating. Make -Havells/Indoasaian/Legrand/ABB/Schnider
Supply and fixing SP 63 Amps rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
-Ditto- all as per item No 11 here-in-before but for SP 40 Amps, 240V, 10KA 'C' curve miniature circuit breaker (MCB) complete all as specified and directed. Note : A sum of Rs 23,850.00 towards sch of credit shall be deducted to arrive the contract sum.
M/s Mukesh Engineers
Shree Ayyappa Engineering
cooltech engineering services
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .