Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 CrAccepted-AOC CHENNAI | CHENNAI | CHENNAI | TAMIL NADU | ₹2.4 Cr | L1 | Accepted-AOC The lowest and negotiated tenderer |
| 2 | L2₹2.4 Cr+₹0.07 (<0.01%)Rejected-Finance MIG 303 B 13 THAARINE NIVAS TNHB PHASE II NOLAMBUR CHENNAI 600 037 | THIRUVALLUR | TAMIL NADU | 600037 | ₹2.4 Cr+₹0.07 (<0.01%) | L2 | Rejected-Finance High rate tenderer |
| 3 | L3₹2.5 Cr+₹9.6 L (4.04%)Rejected-Finance NO 3 BHARATHI STREET RAM NAGAR AMBATTUR CHENNAI 600 053 | CHENNAI | TAMIL NADU | 600053 | ₹2.5 Cr+₹9.6 L (4.04%) | L3 | Rejected-Finance High rate tenderer |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
16 Aug 2023, 6:00 pmClosed
Superintending Engineer/CC
No.132, E.V.R.Salai, Kilpauk, Chennai-10
Renovation work to the office building for Tamil Nadu Pollution Control Board at Ambattur in Chennai city
2023_TNPHC_357223_1
SE/CC/DB/3023/2023
Open Tender
Civil Works
Lump-sum
240 days
Ambattur in Chennai city
Please refer tender documents
7 documents required · 7 mandatory
₹0
₹1.5 L
13 Sept 2023
9 Aug 2023
18 Aug 2023
9 Aug 2023
16 Aug 2023
9 Aug 2023
Amount
1.1) Earth work excavation in all soils (including refilling) a. 0 to 2 mt.
1.5) Earth work excavation for Open foundation (excluding refilling) a. 0 to 2 mt.
7.2) Supply and fixing of Bituminous filler pad, 20 mm tk. for expansion joint
21.2) Teak wood Wrought & Put up a. T.W. over 2 m & below 3 m
b. T.W. below 2 m length.
25) M.S.Holdfast
31) Weathering course
37.1) White washing 3 coats (slaked)
39) M.s Grills
40) Painting - New "wood work"
41) Painting - New "iron work"
52) Supply ,laying & jointing the following pipes as per ASTM D 1785 of schedule 40 with PVC Specials (Above G.L) a. 32mm dia
b. 25 mm dia
c. 20 mm dia
52.1) G.I Pipe 20mm dia for Hot water line (Fully Concealed in walls)
Electrical arrangements 74) Charges for fixing of "Fan"
76) 8 SWG wire
78) Earthing Station IS3043 (Type I)
86) Anti termite treatment
112) Supplying & fixing of Exhaust Fan 300mm dia sweep
238) Anticorrosive treatment for steel grills
ANNEXURE 1.14.2) Providing 300mm dia Auger pile to required depth in standardised concrete mix M25 grade using 20mm gauge HBG stone jelly
2.15) Supplying and filling stone dust
3.1.3) C.C.1:5:10 for Foundation & Basement
3.2.1) P.C.C. 1:2:4 for Foundation & Basement and other similar works
6.2.3) Brick work in C.M. 1:5 (F& B) using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3")
8.2.3.2) Standardised concrete Mix M30 Grade Concrete a) In Foundation and basement
b. In Ground floor
c. In First floor
d. In Second floor
e) In Fourth floor
9.2.2) Brick work in C.M. 1:6 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") a. In Ground Floor
b) In First floor
c) In Second floor
d) In Third floor
e) In Fourth floor
10.2.2) Brick partition work in C.M. 1:4 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") 114 mm tk (B.P.) b. In Ground Floor
c. In First Floor
d. In Second Floor
18.1) Formwork using M.S.Sheet a.For Column footings, plinth beam, Grade beam, Raftbeam, Raft slab etc.,
b.Plain surfaces such as Roof slab, floor slab, Beams, lintels, lofts, sill slab, staircase, portico slab and other similar works
c.For Square and rectangular columns and small quantities
21.5.2.2) Supply and Fixing Solid UPVC door Shutter with frame
21.5.2.3) Supplying and fixing of PVC Sliding Door with Roller
215.6.1) Supplying and fixing of solid core flush door shutter of thickness 35mm a). Door size 1.000 m x 2.400 (Single Leaf)
22.2.4) Supply and fixing of Venetian Blinds for windows of best approved superior quality.
23.2.5) Supplying and fixing of Sun control film for window glass
26.1) Flooring in C.C.1:5:10
28.1) Floor plastering in C.M. 1:4, 20mm tk.
29.8.2) Supplying and fixing of Decorative special type digital Glazed tiles using Grout (Tile Joint Filler)
29.9.2) Supplying and fixing of Decorative special type digital Floor ceramic tiles (Anti-skid) using Grout (Tile Joint Filler).
32.1.1) Pressed tiles (23cmx 23cmx 20mm) mixed with Water proofing compound
33.2) Plastering in C.M. 1:5, 12mm tk.
35.3) Spl. Ceiling plastering in C.M. 1:3, 10 mm tk.
37.3.1) White washing two coats (slaked)
38.5.4) Painting with texture painting 2 coat over one coat of primer
43.1) Fabrication of Mild steel / RTS grills (without cement slurry) for all sizes of rods.
44.2.3.1") Rain water harvesting using defunct borewell and providing perforated cover slab a). Providing pit (M30)
b) Augering 30cm dia
44.5.4.1) Providing Rain Water Harvesting well ring in circular shape of 90cm
44.6") PVC SWR 110 mm dia with ISI mark type- A for Rain water down fall pipe
47.3) Supply and fixing of Stainless steel Towel rail of 75cm long and 20mm dia with brackets
53.4) Supplying & fixing of C.I Manhole cover 60 x 60 cm (50kg weight)
53.5.1) Supplying & fixing of Wash basin (Jaquar make)
54.1.1) Supplying & fixing of 15mm dia half turn CP long body tap
54.2.1) Supplying and fixing of 15mm dia half turn CP short body tap
56.3.2) Supplying & fixing of Indian Water closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade ' P' or "S' trap - in G.F.
56.4.2) Supplying & fixing of Indian Water closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade ' P' or "S' trap - Other than G.F.
57.1.1) Supplying & fixing of E.W.C.(White) 500 mm with PVC SWR grade "P" or "S" TRAP
57.1.5) Supplying & fixing of E.W.C.(Jaquar make)
58.3) PVC SWR pipe (Soil line) with ISI mark - type 'B'. a. 110 mm dia.
b. 75 mm dia.
60.1) Supplying & fixing of PVC Nahani trap (4way/2way)
67.2.3) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. MS Switch Box controlled by 5 Amps Module flush type switch at Switch board itself
68.3.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. MS Switch Box controlled by 5 Amps Module flush type switch at Convenient places.
69.3) Supplying and fixing 15amps 3 pin plug type socket (Module)
75.2) Supply and delivery of 48" (1200 mm) Fan with ISI mark with Eletronic Dimmer
77.5.1) Run off main with 2 wires of 1.5 sq.mm. PVC insulated single core multi strand fire retardant flexible copper cablewith ISI mark conforming to IS: 694/1990,1.1 kv cable. (Open wiring)
77.7.2) Run off main with 2 wires of 2.5 sq.mm. PVC insulated single core multi strand fire retardant flexible copper cablewith ISI mark conforming to IS: 694/1990,1.1 kv cable. (Open wiring)
82.3.1) Supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall
84.2.1) Run off main with 2 wires of 4 sq.mm. PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark conforming to IS: 694/1990,1.1 KV cable (Open wiring)
85.2) Providing laying and fixing 100 mm dia GI Pipe B (medium class)
93.1.1) Plastering with CM 1:3, 20mm with WPC
96.2.8) Supply and Laying Rubber Moulded Hyraulic Pressed Paver Block 63 mm thick
97.5.4) Supplying and fixing of aluminium partition wall (1/3 glass 5.5mm & 2/3 novapan sheet 12mm thick)
97.6.3) Supplying and fixing of aluminium door with 5.5mm thick plain fixed glass.
102.1.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. MS Switch Box controlled by 5 amps Module flush type switch for Administrative block and Community centre (Open wiring) a. Light point with ceiling rose
103.1.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. MS Switch Box controlled by 5 amps Module flush type switch Fan point for Administrative block and Community centre. (Open wiring)
104.1.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. MS Switch Box controlled by 5 amps Module flush type switch for Staircase light point for Administrative block and Community centre. (Open wiring)
105.3.1) Run off 4 Wires of 4 sqmm PVC insulated single core multi strand (open wiring)
107.3.1) Run off 4 Wires of 10 sqmm PVC insulated single core multi strand (open wiring)
146.9) Providing, laying and fixing of 300mm dia RCC Hume pipe NP2 Class IS 458/2003 with RCC collars
175.1.1) Supply and fixing of 7 segment (3 tier) 3 phase distribution with 6 way TPN MCB
175.2.1) Supply and fixing of 7 segment (3 - tier) type 3 phase 6 way triple pole and neutral MCB sheet steel enclosure
175.3.1) Supply and fixing of vertical type 6 way triple pole and neutral 63a TPN MCB sheet steel enclosure
177.2.1) Supply and fixing Vertical type TPN 8 way MCB with 125A 4 pole MCB
177.4.1) Supply and fixing of Industrial type Horizontal type 3phase DB with 8 way TPn MCB
180.1.1) Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection (For Neutral Earthing of UPS systems)
180.1.2) Supply and run of 25mm x 6mm GI strip flat with necessary clamps / supports on wall / floor / ground for earth connection. (Body earthing in Generator and all panels)
180.1.3) Supply and run of 25mm x 6mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection (For Neutral Earthing of Generator)
184.2.2) Supply and fixing of square type reccessed fitting with LED of best approved quality with ISI mark a) 24 W 4000k 2 x2 square type recessed fitting with LED bulb
184.2.6) Supply and fixing of 18W LED 3000K Round Type Recessed Fitting with LED bulb
186.3) Supply and fixing of 3 Nos. 5A (3 pin and 2 pin) combined flush type wall socket (for UPS plug socket)
186.4) Supply, installation, testing and commissioning of 15KVA Online UPS system operating on 415V, 50 Hz, 3 phase
207.3.1) Plastic Emulsion paint two coats with including primer for inner walls
207.3.5) Painting the old walls with two coats of interior Plastic Emulsion paint including thorough scrapping.
207.6) Painting the old iron works with two coats of synthetic enamel ready mixed paint including thorough scrapping
207.7) Painting the old wood work with two coats of approved Ist class synthetic enamel paint
213) Supply and fixing of SFRC Manhole Cover a) 600mm x 600mm
215) Dismantling the damaged weathering course in lime concrete
217) Dismantling the damaged Pressed tiles laid over cement mortar and Weathering Course
221) Removing the damaged broken door/window /ventilators including the removal of frames, hinges, fastenings and shutters
222.6) Dismantling of Brick wall in CM 1:4
222.7) Dismantling the existing damaged RCC with out affecting the adjacent structures. Including machineries and labour charges
235.3.4) Attending the Cracks with Groove Cutting With Cutting Mechain and applying crack filler for filling the Cracks including Scafloding etc., Complete.
236) Providing two legged scaffolding using 15cm diameter casurina props d) For 10.5m height in addition of 2.5m ht.
238.1) Anticorrosive treatment for Steel window / MS grills
239.1) Shear connector for Lintel: Drilling holes of diameter in RCC of any grade holehas to be frilled of 10mm to 20mm dia for required depth of 75mm.
239.1.1) Anti corrosive coating: Providing and applying Nitozinc primer, two component, zinc rich, epoxy primer to the exposed rebars.
239.1.2) Old Concrete & Micro concrete bonding agent: Providing and applying Nitobond EP, two component, epoxy resin bonding agent over the prepared concrete surface.
239.1.3) Form work for Micro concrete: Supply of slurry tight formwrok which should not deform and leak due to pressure of micro concrete.
239.1.4) Jacketing with Micro concrete: Providing and appying of average 50mm thick of plastic shrinkage compensated micro concrete.
239.1.5) Patch repair treatment: Providing and applying of Renderoc SP 40, shrinkage controlled, polymer modified.
239.1.6) Clearing the surfaces by means of surface should be free from loose particles.
239.1.7) Supply and grouting of low viscosity epoxy resin in all cracked areas
239.1.8) Applied two coats of component acrylic polymer modified water proof coating
239.1.5) Provide 150 GSM Geo textiles slip membarane as a protection of water proofing system before providing screed concrete.
239.2) Inner ceiling work: Removing existing plastering clean the surface with one coat water proof coating.
239.3) Providing Polymer coating (Water Proof Coating) for sunken portion of toilet.
241) Dismantling the damaged Floor finish & dadooing walls in cement mortar with Mosaic Tiles / Glazed Tiles / Clay Tiles / Cuddapah Slabs
241.1) Clean removal of Cement plaster from wall and flooring
241.2) Clean removal of Cement plaster from wall and flooring
243.7.1) Removing the damaged electrical pipe lines including labour charges.
243.7.2) Removing the damaged light point with ceiling rose, without ceiling rose, 5amps switch board itself and convenient place including labour charges.
243.7.3) Removing the damaged ceiling fan and tube lights including labour charges.
343.1) Supplying and fabricating of MS steel section for fabriction for Truss work
343.1.3) Supply and fixing of Galvanium roof sheet of 0.47mm thick
344.2.1) S & F of Special type mirror 1000 x 780mm
359.3.2) Concrete designer tiles flooring
365.1) Supplying and fixing stainless steel hand rails
366.1) Supplying & fixing of Stainless steel Hand Rails for staircase wall side
361.6) Vitrified Tiles flooring (Ivory)
379.4.8) S & F of Granite slab of size 4'x2' and above 18 to 20mm thick For platform (Jet black) C.M 1:3, 20mm tk a. In Ground floor
b. In First floor
c. In Second floor
379.7.1.1) Providing PVC trim beeding of suitable size & colour for corner of wall tiles
382.4.1) Supplying and fixing of (Jet black) Granite slab 18 to 20mm thick urinal partition both side superfine polished with machine cut edges
382.4.2) Supply and fixing of white glazed Porelain oval shape special type urinal of size 382 x398 x601mm
383.3.1) Providing double nosing to the edges of Granite slab of 18 to 20mm thick
450.9) Supplying and fixing of C.P. shower arm with overhead shower rose of best approved quality with ISI mark
450.9.2) Supplying and fixing of best approved quality C.P. wall mixer two in one with hand shower confirming to I.S. specification of approved best quality.
451.1.1) Supplying and fixing of 1000W/230W Automatic electric water heater of 25 litres capacity
451.3) Supply and fixing of CP two way bib cock with health faucet of approved quality with ISI mark
455) Supply and fixing of Health faucet approved quality with ISI mark
456) Supply and fixing of oval shape wash basin colour of size 560 x 450mm of best approved quality with ISI mark
465.3.3) Supply and installation of Anutone (or) equivalent Acoustical False ceiling.
465.3.4) Providing wall parition using 12mm thick BWR plywood over 2" x1" aluminium channel bothside laminated with 1mm thick mica sheet.
465.3.5) Providing wall panelling using 12mm thick WPP water proof over 2" x1" aluminium channel plywood laminated with 1mm thick mica sheet.
465.3..6) Providing Stage using 19mm thick BWR plywood laminated with 1mm thick mica sheet with 250mm height legs.
465.3.7) Supplying and fixing of Vinyl flooring 2mm thick including cost and labour charges.
513.1) Plate earthing with copper plate of size 600 x 600 x 3.15 mm as per the ISI specification with an earth electrode of 2.1 m class 'B' GI pipe
513.2) Supplying, installing and connecting a GI plate earthing of size 300mm.x 300 mm.x 3.15mm. at a depth of 3000 mm
528) Supply and installation of following sizes of perforated Powder coated Cable trays of 2mm thickness and 50mm height for supporting cables a) 150 x 50mm Size
b) 300 x 50mm Size
532.2) Providing one coat of Wallputty for new plastered surface
540.1.6.1) Supplying and fixing of Cassette AC a) 2 Ton AC Unit (3 star)
540.1.6.2) Supplying, delivery and Installation of Hi - Wall split Air conditioner with cordless remote. a) 1.5 Ton AC Unit (3 star)
b) 2 Ton AC Unit (3 star)
540.1.6.3) Labour charges for fixing the Cassette type Hi wall split AC including machinaries
540.1.7.1) Supply and fixing of MS stand for fixing outdoor unit of approved make
540.1.8.1) Supply and fixing of PVC water drain pipe of 1" dia with specials (For AC)
540.2.1) Supply and laying of 5/8" and 3/8" copper pipe (Extra beyond 3 metrs supplied with AC unit)
540.4) Removing of Air conditioner inlcuidng tools and plants.
540.4.1) Labour charges for refixing the existing Air conditioner with Gas refilling including tools and plants.
619.7) Supplying and fixing the following dia ball valve of approved make a) 25mm dia
b). 32mm dia
706.4.1) Supplying, erecting, testing and commissioning of floor mounted cubical type Main MV panel
706.5.1) Supplying, erecting, testing and commissioning of floor mounted cubical type UPS Power Panel
706.6.1) Supplying, erecting, testing and commissioning of 50KVAR APFC Panel
706.7.1) Supplying and fixing of CT- METERING PANEL: at EB ROOM(75HP-150HP/56-112 KW (which includes LTCT meter panel board 6 Nos. suitable fuse carriers
707.3.5) Supplying and laying 3 core 50 sqmm Flat type copper with ISI mark including cost of all materials specials etc. all complete.
724.5) Supplying and laying of following sizes of PVC / XLPE armoured aluminium LTUG cable on post or on wall/ Trays (Above Ground level) a) 4C x 10 sqmm
b) 4 x 16 Sq.mm
c) 3.5 x 50 Sq.mm
d) 3.5C x 70 sqmm
e) 3.5 C x 150 sqmm
f) 3.5 C x 185 sqmm
g) 3.5 C x 240 sqmm
724.6) Supplying and laying of following sizes of PVC / XLPE armoured aluminium LTUG cable in a trench. (Below Ground level) e) 3.5 C x 150 sqmm
f) 3.5 C x 185 sqmm
g) 3.5 C x 240 sqmm
724.7) Supply and fixing of brass cable gland suitable for the following sizes of cables a) 2C x 10 sqmm
b) 2C x 16 sqmm
c. 3.5C x 50 sqmm
d. 3.5C x 70 sqmm
e) 3.5 C x 150 sqmm
f) 3.5 C x 185 sqmm
g) 3.5 C x 240 sqmm
724.8) Supplying and fixing of cable end termination for following PVC / XLPE armoured LTUG Aluminium cable. c. 3.5C x 50 sqmm
d. 3.5C x 70 sqmm
e) 3.5 C x 150 sqmm
f) 3.5 C x 185 sqmm
g) 3.5 C x 240 sqmm
741.8) Supply and fixing of 20 Amps DP plug and socket in sheet enclosure with 32 A DP MCB in Flush with wall with earth connection ( For AC Plug ) Legrand ( MDS) / Hager( L& T) Equivalent/ Superior variety
774.1) Supply, installation, testing and commissioning of 8 mega pixel IP bullet Outdoor Camera
774.2) Supply, installation, testing and commissioning of 8 mega pixel IP Dome Indoor Camera
774.3) Supply, installation, testing advanced technology Day and Night outdoor Camera 5MP IP Camera
774.4) Providing 16 Chennel - 4K Network Video Recorder with 2 SATA Hard disk support
774.5) Providing 12 TB 6000 GB x2 Western Digital brand Surveillance hard disk drive - Especially for CCTV Surveillance storage.
774.6) Providing 32 inch LED TV Full HD Resolution TCL 81.28cm
774.7) Providing 2 KVA (2000VA) UPS with 2 batteries of approved. Make: Microtek / Equivalent
774.8) Supplying and fixing of 8 Port Smart POE (Power On Ethernet Switch) unmanaged Desktop switch
774.9) Supplying of outdoor CAT 6 UTP Cable - Network cable
774.9.1) Supplying of Pwer cable 2 core PVC insulated multicore electricl wire copper material.
774.9.2) Labour charges for wiring with PVC pipe accessories
832.5.2) Supplying and fixing in position of UPVC window of casement type( open) for all sizes
832.5.3) Supplying and fixing in position of UPVC Ventilator louvered ventilator type for all sizes
943.5) Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683
943.5.1) Supplying of Treatment Chart in English and Tamil directly fixed onto the wall
943.5.2) Supplying, and laying ISI Marked2MX1M Rubber mats for LT Panel Boards.
943.5.3) Supplying and fixing 440 V Danger Board.
943.5.4) First Aid Box with all medicines-EB room
943.5.5) Supplying, and fixing fire buckets made out of 40x40x6mm MS angle &Filled sand with necessary accessories.-4nos. Set
943.5.6) Hand Gloves 11 KV grade
959.4) Supply, installation, testing and commissioning of 160 KVA Generator set with AMF panel
960.4.5.1) Supply and fixing of 4' 18 watts LED Tube Light (Crystal glass)
Haarine Associates
K. BASKARAN & CO
Bidder Name
A NARAYANAN
Haarine Associates
K. BASKARAN & CO
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_425905.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .