| 1 | L1₹24.5 LQualified Make: microtek
Model: Microtek 1000VA Twin Guard Plus UPS - TWIN GUARD PLUS+ 1886 12 CHUNAMANDI PAHARGANJ CENTRAL DELHI | Make: microtek
Model: Microtek 1000VA Twin Guard Plus UPS - TWIN GUARD PLUS+ | L1 | Qualified | |
| 2 | L2₹25.5 L+₹1.0 L (4.19%)Qualified Make: BPE
Model: BPE 1KVA LINE INTRACTIVE UPS 7AH*2NOS BATTERY 5YRS AAREY MILK COLONY MUMBAI MAHARASHTRA 400065 | MUMBAI SUBURBAN | MAHARASHTRA | 400065 | Make: BPE
Model: BPE 1KVA LINE INTRACTIVE UPS 7AH*2NOS BATTERY 5YRS | L2 | Qualified | |
| 3 | L6₹27.6 L+₹3.1 L (12.7%)Qualified Make: LUMINOUS
Model: LUMINOUS 1 KVA UPS 202 BUILDING NO 3 SECTOR 3 MILLENNIUM BUSINESS PARK MAHAPE GHANSOLI THANE MAHARASHTRA 400710 | THANE | MAHARASHTRA | 400710 | Make: LUMINOUS
Model: LUMINOUS 1 KVA UPS | L6 | Qualified | |
| 4 | L7₹27.9 L+₹3.4 L (14.0%)Qualified Make: Uniline
Model: Smartline-SL-1000-VAH168-MS-70PC-EA 198 23 UNILINE HOUSE EAST OF KAILASH RAMESH MARKET NEW DELHI DELHI 110065 | SOUTH EAST DELHI | DELHI | 110065 | Make: Uniline
Model: Smartline-SL-1000-VAH168-MS-70PC-EA | L7 | Qualified | |
| 5 | L8₹27.9 L+₹3.5 L (14.3%)Qualified Make: microtek
Model: Microtek 1000VA Twin Guard Plus UPS - TWIN GUARD PLUS+ 415 JOP PLAZA SECTOR 18 NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | Make: microtek
Model: Microtek 1000VA Twin Guard Plus UPS - TWIN GUARD PLUS+ | L8 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
15 Oct 2018, 9:00 amClosed
Line Intractive UPS with AVR Average Turn Over of Last 3 Years 75 Lakh (s) Experience with Gov. Required 3 Year (s) Line Intractive UPS With AVR ( 576 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/168 1.0/168
1.0/216
1.0/400 Technology MOSFET-PWM MOSFET-PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 Rated Output (Volt) Single Phase Quasi-Sin- wave 230 V AC
50 Hz Single phase sinewave 230v AC
50Hz
Single Phase Quasi-Sin-wave 230 V AC
50 Hz Degree of protection IP-21 IP-21 Inverter Efficiency (%) >/= 70% >/= 70% Warranty for the battery from the date of delivery 1 year 1 year
3 Years Warranty for Line 5 Years 5 Years 1/4 Interactive UPS Installation and commissioning instructions Yes * CONSTRUCTIONAL Type of enclosure ABS * AC out put for printer (not through inverter) Yes Yes
No Inverter out put socket AC out put for printer (not through inverter) 3 Three pin 3 Three pin FUNCTIONAL Total harmonic distorsion (%) </= 40% * Input (Volt) Single phase sinewave(160-280v) * Switching over time (Mili sec) Maximum 10 milli seconds * Overload Time (Minutes) >/= 10 minutes * Load power factor >/= 0.6 * Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9%
50 +/-3 Hz * Overload (%) >/=10% * Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% * Variation on output frequency in battery mode (Hz) </=0.5 * PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 * Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts
the system shall switch over to battery mode Yes * Protection against short circuit of UPS Yes * 2/4 Protection for over voltage and over load Yes * REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree
RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes * Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes * Cold Test as per IS:9000 pt-2/sec-4 Yes * Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes * Type Test certificate no. and date - * Name Of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Biju Singha 110003
IT WING
IST FLOOR
10 CGO COMLEX
LODHI ROAD
NEW DELHI - 3 576 60
685721
GEM/2018/B/97103
Line Intractive UPS with AVR
60 days
Delhi; New Delhi
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Line Intractive UPS with AVR Average Turn Over of Last 3 Years 75 Lakh (s) Experience with Gov. Required 3 Year (s) Line Intractive UPS With AVR ( 576 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/168 1.0/168 | - | - | - |
| 1.0/216 | - | - | - |
| 1.0/400 Technology MOSFET-PWM MOSFET-PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 Rated Output (Volt) Single Phase Quasi-Sin- wave 230 V AC | - | - | - |
| 50 Hz Single phase sinewave 230v AC | - | - | - |
| 50Hz | - | - | - |
| Single Phase Quasi-Sin-wave 230 V AC | - | - | - |
| 50 Hz Degree of protection IP-21 IP-21 Inverter Efficiency (%) >/= 70% >/= 70% Warranty for the battery from the date of delivery 1 year 1 year | - | - | - |
| 3 Years Warranty for Line 5 Years 5 Years 1/4 Interactive UPS Installation and commissioning instructions Yes * CONSTRUCTIONAL Type of enclosure ABS * AC out put for printer (not through inverter) Yes Yes | - | - | - |
| No Inverter out put socket AC out put for printer (not through inverter) 3 Three pin 3 Three pin FUNCTIONAL Total harmonic distorsion (%) </= 40% * Input (Volt) Single phase sinewave(160-280v) * Switching over time (Mili sec) Maximum 10 milli seconds * Overload Time (Minutes) >/= 10 minutes * Load power factor >/= 0.6 * Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9% | - | - | - |
| 50 +/-3 Hz * Overload (%) >/=10% * Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% * Variation on output frequency in battery mode (Hz) </=0.5 * PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 * Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts | - | - | - |
| the system shall switch over to battery mode Yes * Protection against short circuit of UPS Yes * 2/4 Protection for over voltage and over load Yes * REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree | - | - | - |
| RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes * Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes * Cold Test as per IS:9000 pt-2/sec-4 Yes * Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes * Type Test certificate no. and date - * Name Of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Biju Singha 110003 | - | - | - |
| IT WING | - | - | - |
| IST FLOOR | - | - | - |
| 10 CGO COMLEX | - | - | - |
| LODHI ROAD | - | - | - |
| NEW DELHI - 3 576 60 | - | - | - |
Exempted
15 Oct 2018
2 Oct 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_685721.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .