| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAccepted-AOC | L1 | Accepted-AOC Quoted Lowest Rates | |
| 2 | L2₹10.9 L+₹61,985.50 (6.04%)Rejected-Finance 14 4A KALI PRASAD C HAKRABORTY ST CAL KOLKATA 700003 | KOLKATA | WEST BENGAL | 700003 | L2 | Rejected-Finance Quoted Higher Rates | |
| 3 | L3₹11.7 L+₹1.4 L (13.8%)Rejected-Finance | L3 | Rejected-Finance Quoted Higher Rates |
Tender Value
₹10.4 L
EMD Value
₹20,900
Closing Date
25 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJ WABLE NARESH DEVRAM GE I CG P KOLKATA
DAMODAR COMPLEX GARDEN REACH ROAD KOLKATA 23
PROVISION OF GUARD ROOM AT MAIN GATE AT CGRA MANICKTALA UNDER GE (I) (CGP) KOLKATA
2020_MES_342213_2
8831/E8
Open Tender
Civil Works
Item Rate
180 days
KOLKATA
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE I CG P KOLKATA
₹20,900
Yes
31 Jul 2020
5 Jun 2020
27 Jun 2020
5 Jun 2020
25 Jun 2020
11 Jun 2020
60 days
Amount
Excavating in trenches n. exc. 1.5 m. wide and n. exc. 1.5 m. in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pire holes, etc. n. exc. 10 sqm on plan and not exc. 1.5 m. in depth and getting out in soft/loose soil complete all as specified and as directed.
Excavating in trenches n. exc. 1.5 m. wide and n. exc. 1.5 m. in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pire holes, etc. n. exc. 10 sqm on plan and exc. 1.5 m. but n. exc. 3.0 m. in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning filling including spreading levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and as directed.
Removing excavated soil not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point in soil complete all as specified and as directed.
M&L PCC 1:4:8 type D2 type (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete etc complete all as specified and directed.
M&L RCC (design mix) M-25 (using 20 mm graded crushed stone aggregate) as in foundation, plinth beams, base of column, footing and mass concrete etc. complete all as specified and directed.
M&L RCC (design mix) M-25 (using 20 mm graded crushed stone aggregate) as in columns, pillars, piers posts and struts etc. complete all as specified and directed.
M&L RCC (design mix) M- 25 (using 20 mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintel over 1.5 m span complete all as specified and directed.
M&L RCC (design mix) M- 25 (20mm graded agg) as in slabs supported on walls, beams and columns in floors , roofs landing etc,complete all as specified and as directed.
M & L RCC M-25 (Design Mix) (20mm graded agg) as in chajias, complete all as specified and as directed.
Use and waste form work to side of concrete foundation, footings, bases of columns, raft and beams and similar work, vertical or to batter as in rough finished surfaces of concrete all as specified and directed.
Use and waste of form work to sides of pillars, posts, struts, piers, columns etc. square, rectangular or polygonal section as in fair finished surfaces complete all as specified and directed.
Use and waste of form work to sides and soffits of floor or roof beams, lintels, over 1.5 m span, cantilevers, shelves including supports, overhangs etc. complete all as specified and directed as in flat and fair finished surfaces complete all as specified and directed.
Use and waste of formwork to soffits of suspended slabs such as roof slabs , floor slabs landing and similar work , not exceeding 200 mm thick (Horizonal or sloping) for flat fair finished surfaces of concrete complete all as specified and directed
M&L MS TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia as reinforcement complete all as specified and directed.
M&L M.S. TMT bars 5 mm dia and over, cut to length, bent to shape required including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia as in stirrups spaces, binders and nibs etc. complete all as specified and directed.
S&F 6 to 8 mm dia TMT Bars incl cutting bending, binding with MS annealed wire not less than 0.90 mm dia for slab,complete all as specified and as directed.
M&L brick work with sub class 'B' bricks straight or curved in plan exc 6 mtr mean radius built in CM (1:6) using old size bricks complete all as specified and as directed.
Surface excavation not exc. 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil all as specified and directed.
M&L PCC 1:3:6 type C2 type (using 40 mm graded broken stone aggregate) as in foundation filling and mass concrete etc complete all as specified and directed.
M&L for sand filling under floor including watering and consolidation complete all as specified and directed.
Excavation over areas not exc. 1.5 m deep and getting out in soft/loose soil all as specified and directed.
M&L hard core of broken stone of gauge n. exc. 63 mm, deposited, spread and levelled in layers n. exc. 15 cm thick, watered and rammed to a true surface all as specified and directed.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Demolition of Reinforcement cement concrete n exc 15 cm thickness (below or above ground level) (Reinforcement cut as required to facilitate demolition)
M&L for 15 mm thick rendering on brick or concrete surfaces of wall in CM 1:6 and finished even and smooth without using extra cement complete all as directed.
M&L for rendering 20 mm thick on brick or concrete surfaces in two coats, first coat 10 mm thick in CM 1:4 and final coat 10 mm thick in CM 1:4 including WPC @ 2% by weight of cement or as per manufacturer instructions for final coat, finished surface even and smooth without using extra cement complete all as directed .
Supply only integral water proofing compound conforming to IS-2465-1975 complete.
M&L rendering 5 mm thick in cement mortor 1:3 on concrete surfaces as in ceilings (sunshed, chajja etc) and finishing surfaces even and smooth without using extra cement complete all as specified and directed.
M&L screed bed or bedding layer 15 mm thick in cement mortar 1:6 on floors for laying floor finish complete all as specified and as directed.
M&L backing Layer 10mm thick in Cement Mortar 1:4 on Walls, etc. for fixing Tiles as Skirtings, Dados, etc, complete all as specified and directed.
M&L non skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match compete all as specified and directed. (Note : Screed bed or bedding layer shall be measured and paid separately under respective items in this schedule).
M&L coloured Glazed ceramic tiles in vertical surface 450 x 350x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed. (Note : Screed bed or bedding layer shall be measured and paid separately under respective items in this schedule).
S&F anodised aluminium powder coating window / ventilator shutters, side / top hung type with styles, rails, without sash bar all are made from anodised aluminium section weighting 0.55 kg / m including necessary jointing cleats, glazing clips, rubber packing, anodised aluminium snap beadings, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.), hinges type B-21 100mm long (2 no.) suitable handle (1 no.) etc complete all as specified and directed.
S&F MS butt hinges medium weight cold rolled of size 50 mm complete all as specified and directed.
S&F 300 mm long aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as directed.
S&F figured glass 3.0 mm thick ordinary quality pin head type glazing with oil putty or wooden beads in square, rectangle n. exc 0.5 Sqm in each pan all as specified and as directed.
S&F sheet glass 5.50 mm thick ordinary quality and glazing with oil putty or wooden beads in square, rectangle exc 0.5 Sqm in each pan all as specified and as directed.
S&F factory made solid PVC door Frame of size 50 mmx47 mm made out of 5mm thick wood grain printed PVC sheet and edges will be painted to match with printed sheet reinforced M.S. square tube, supplying & fixing in opening as per specification & drawing on page no. 160 of SSR Part -II complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. square tube for top and bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip 20 mm wide stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in M.S. frame welded /sealed to the stiles and rails with suitable sheet beading, and jointed together with solvent cement, supplying & fixing in the frame at site as per specification and drawing of page no 156 of SSR Part -II complete all as specified and directed.
S&F mild Steel butt hinges medium weight cold rolled of size 100 mm complete all as specified and directed.
S&F aluminium handle 150 mm long anodised fabricted type fixed complete all as specified and directed.
S&F 200 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks (cylindrical, vertical with closed top) hoisted and fixed in position of 500 Ltr capacity all as specified in SSR and as directed.
S&F brass ball valves 20 mm dia high pressure, with polythene float and fly nut complete screwed for iron pipe or brass ferrule complete all as specified and directed.
S&F 40 mm dia steel water tube medium grade galvanised with all fittings and fixed complete to walls, ceilings or laid in floors complete all as specified and directed.
S&F 20 mm dia steel water tube medium grade galvanised with all fittings and fixed complete to walls, ceilings or laid in floors complete all as specified and directed.
S&F 15 mm dia steel water tube medium grade galvanised with all fittings and fixed complete to walls, ceilings or laid in floors complete all as specified and directed.
M&L 25mm dia anodised aluminium alloy curtain rod with catrip type with hooks/brackets fixed on walls complete all as specified and directed.
M&L Marble (table rubbed and polished) tiles, 18 - 20 mm thick machine cut in steps, jambs, pillars, window cills, cooking platforms and like laid over cement screed bed 15 mm thick of 1:6 CM and jointed with grey cement slurry and pointed with white cement (1:2) with admixture of pigment to match the shade of the marble of folllowing types (a) Markhana white including cutting and polishing complete all as specified and directed.
M&L Granite (of any type) tiles, 18 - 20 mm thick machine cut in steps, jambs, pillars, window cills, cooking platforms and like laid over cement screed bed 15 mm thick of 1:6 CM and jointed with grey cement slurry and pointed with white cement (1:2) with admixture of pigment to match the shade of the granite stone including cutting and polishing complete all as specified and directed.
S&F 15 mm dia PVC connections, 450 mm long with PTMT nuts of suitable size at two end complete all as specified and directed.
S&F vitreous china squatting, Orissa pattern size 580 x 440 xmm white with integral foot rest lime concreteing all complete as specified & directed.
S&F stop valves (chromium plated fancy type) 15 mm dia, cast copper alloy, screwed down, high pressure with crutch or butterfly handles, screwed both end for iron pipe or for unions complete all as specified and directed .
S&F 15 mm dia pillar taps, cast copper alloy with capstan head, chromium plated, screwed down, high pressure with or without letter 'Hot' or Cold' with long screwed shanks and fly nuts screwed for iron pipes complete all as specified and directed. (Make : Jaquar model no CON-011KN or equivalent)
S&F 15 mm bib tap, cast copper alloy fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. (Make : Jaquar model no CON-037KN or equivalent )
S & F 100 mm dia PVC Floor trap with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) all as specified and directed.
S&F PTMT grating dome 100 mm dia (minimum weight 25 gms) complete all as specified and directed.
M & L preparation of newly plastered surfaces of walls and applying two coats of cement base paint complete all as specified and directed.
M&L preparation of newly plastered surfaces of wall and apply three coats of white wash complete all as specified and directed.
M&L for preparing newly plastered surfaces of ceiling and applying three coats of white washing complete all as specified and directed.
M&L water proofing treatment on cleaned RCC roof comprising with the following operation and as specified here-in-below :- (a) 20 mm thick (av. mimimum thickness) plastering in cement mortar 1:3 finishing the plastered surfaces even and smooth over cleaned RCC roof. The plastered surface shall be cured properly for ten days by ponding of water over roof. (b) Applying bitumen primer over the plastered surface @ 0.40 Ltr / Sqm by the same membrane manufacturer of density at 25°C, 0.87 to 0.89 kg / Liter and viscosity 70-160 cps. (c) Providing and laying 3mm thick APP (Atactic Polypropylene Polymer) modified prefabricated five layer, weight not less than 3.6 kg/Sqm water proofing membrane, black finished reinforced with non woven polyester matt make as approved over the primer coat. Membrane shall be laid using butane torch and sealing all joints etc all as per Para 11.44.5 of SSR Part I. (d) Applying one coat of Aluminium paint @ 0.1 ltr per Sqm over APP based polymetric membrane complete all as per manufacturer's instruction.
M&L machine pressed pre polished pre -cast concrete interlocking paver block any shape & size conforming to IS 15658-2006 of 60 mm thickness, M-35 grade with grey cement & pigment complete all as specified and directed.
M&L PCC 100 mm thick 1:4:8 type D2 type (using 40 mm graded broken stone aggregate) as in foundation filling and mass concrete etc complete all as specified and directed.
M&L cement concrete 1:2:4 Type B1 (using 20 mm graded crushed stone aggregate) as in coping, roof kerb or similar work, rounded or chamfered on edges including necessary form work complete all as specified and directed.
M&L for precast RCC 1:2:4 type B1 using 20 mm graded aggregate set in CM (1:4) for manhole covers, chullah hoods, chajjas, shelves and similar articles including necessary form work complete all as specified and directed.
M&L 40 mm thick damp proof course in cement concrete 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate mixed with wpc to horizontal or vertical surfaces including necessary form work complete all as specified and directed. ( Note : WPC shall be measured and paid separately).
M&L treating the back fill in contact with foundation at the rate of 7.5 Ltrs of emulsion per Sqm of vertical surface (Area of the substructure in contract with back fill to be measured) complete all as specified and directed.
M&L treating top surface of filled earth at the rate of 5 Ltrs of emulsion per Sqm of surface all as specified and directed.
M&L treating the soil alongwith external perimeter of building at the rate of 2.25 Ltr of emulsion per mtr of the perimeter wall as specified and directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or stainless steel wire staple complete all as specified and directed.
S&F 2nd class hardwood plain solid, straight chowkat and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complere all as specified and directed.
S&F 30 mm thick flush shutters solid core construction, with particle board core and ply wood face panels commercial type on both sides complete all as specified and as directed.
S & F 35mm thick 2nd class hard wood glazed and skeleton shutter, open rebated and prepared to receive gauze, glass etc (without sash bar) edges of framing plain chamfered or rounded fitted with cut and mitred beads,the size of the member of shutter as SSR part-1clause 8.24
S&F mild steel flat iron as in hold fast for door window frames or chowkat etc. cut to length or drilled hole and fixed with screw etc. complete all as directed grade of steel conforming to Fe-290, Gde-E-165.
S&F M.S. framed work such as grills gratings etc with end of bars shouldered/or riveted or forged into spikes framed guard bar, barred iron doors, ladders, framed balusters, walkways, railing, frame work of water tanks and similar works steel quality conforming to Fe-290, Grade E- 165 complete all as specified directed .
Preparing surfaces of wood and wood based materials, steel or ironwork, new of any description and girth not otherwise described and treating with tar or coal tar black paint for small articles such as stop, covers, gully gratings, holdfasts, ends of posts, back of chowkats etc. area tarred n. exc. 0.10 Sqm each.
M&L sanding newly tarred or painted surfaces with clean sharp sand all as specified and as directed.
Preparing surfaces of wood and wood based materials new of any description and girth not otherwise described and treating with tar or coal tar black paint at ends of post back of chowkats etc area .
M&L 100 mm thick PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in sub base in floors finished even all as specified and directed.
M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and directed.
M&L cutting into existing manholes for connecting new drains, making good to 150mm pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section ) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required.
S&F vitreous China Wash down water closet pan (Pedestal Pattern) 580 x 440 mm size, white fixed with brass screws with necessary connection with water line and sewer line etc. complete including Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device for pedestal pan complete all as specified and directed .
S&F 10 Ltr capacity PVC valveless syphonic action type flushing cistern low level white, with inlet, ball valve, float and handle including PVC flush pipe and brackets complete fixed in wall and floor to trap of WC as required and as directed.(Make Parryware, Model -slimline economy or equivalent).
S&F 110 mm dia PVC (SWR) pipes single, socketed, in any length with rubber ring joints laid in trenches or floors complete all as specified and directed .
S&F PVC (SWR) bends any radius of 75 mm dia with access door complete all as specified and directed.
S&F 75 mm dia PVC (SWR) pipes single, socketed, in any length with rubber ring joints laid in trenches or floors complete all as specified and directed .
S&F vitreous China Wash Basin, white, flat back of size 550 x 400 mm including suitable size of CI brackets but excluding brass chromium plated waste fittings, flange and bedded in red lead cement complete all as specified and directed .
S&F stop valves (chromium plated fancy type) 15 mm dia, cast copper alloy, screwed down, high pressure with crutch or butterfly handles, screwed both end for iron pipe or for unions complete all as specified and directed .
S&F 20 mm dia gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed .
S&F 15 mm dia gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed .
M&L preparation of new or previously untreated wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L point wiring with 1.5 Sqmm (nominal area), PVC insulated, stranded single core unsheathed HRFR / FRLS copper conductor cable 1100 Volts grade drawn through with and including PVC conduit medium duty (ISI marked) not less than 20 mm dia and all fittings and accessories (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core HRFR / FRLS copper cable as earth continuity wire connecting to common earth point including supply & fixing of 1.6 mm thick pressed mild steel terminal boxes of suitable size with 3 mm thick PVC / Plastic laminated sheet. top cover, suitable sizes of brass screws and washers etc. for mounting switches, sockets, regulators etc complete for one light point / exhaust fan point controlled by one way switches complete all as specified and directed.
All as per item no.95 above but for one three pin 5 Amp socket outlet on independent board.
All as per item no.95 above but for one three pin 5 Amp socket outlet on same board.
M&L point wiring with 2.5 Sqmm (nominal area), PVC insulated, stranded single core unsheathed HRFR / FRLS copper conductor cable 1100 Volts grade drawn through with and including PVC conduit medium duty (ISI marked) not less than 20 mm dia and all fittings and accessories (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core HRFR / FRLS copper cable as earth continuity wire connecting to common earth point including supply & fixing of 1.6 mm thick pressed mild steel terminal boxes of suitable size with 3 mm thick PVC / Plastic laminated sheet. top cover, suitable sizes of brass screws and washers etc. for mounting switches, sockets, regulators etc complete for three pin 15 Amp socket outlet on independent board complete all as specified and directed.
S & F switch piano, flush type, 5/6 Amps, 240 Volts, single pole, one way, conforming to IS complete all as specified and as directed.
M & L Ceiling rose, surface type polycarbonate/ PVC three terminals, conforming to IS, complete all as specified and as directed.
S & F Switch socket combination 5 Pin, 16/6 Amps, flush type, multipurpose, conforming to IS complete all as specified and as directed.
S & F Switch socket combination 5 Pin, 6 Amps, 240 Volts, flush type multi-purpose, conforming to IS complete all as specified and as directed.
S&F socket outlet 3/5 pin 5 Amps flush type complete all as specified and as directed.
Supply and fix sheet metal enclosure powder coated, MCB DB SPN 4 way double door for incoming bus bar, neutral links all as specified and directed . (Make :Legrand Cat No. 6077 10 or equiv in Schneider /GE)
Supply and fix MCB DP 240V, 6-32 Amps capacity complete all as specified and directed. (Make : Legrand cat No 4086 28-36 or equivalent in Schneider/GE )
Supply and fix MCB SP 240V, 6-32 Amps capacity complete all as specified and directed. (Make : Legrand cat No 4085 87-95 or equivalent in Schneider/GE )
S&F 20W LED light fitting LED batten for surface and pendant, seperate joints/ connector required for continuous mounting , anodised aluminium extruded luminaire housing and acrylic diffuser, slimmest batten for high end applications including connection with suitable 3 core wire from ceiling rose to fitting terminal complete all as specified and directed (Make : Havells ordering code LHEWEBP7IN1W020 or quivalent in Crompton/ Philips/ Bajaj).
S & F Building security light fitting, LED type, suitable for 10 LEDs complete with driver etc mounting arrangement of 25 mm dia medium grade GI pipe bracket 1.0 mtr long bent to shape, mounted on wall with suitable bolts, nuts, saddles including connection with 2 core PVC insulated sheathed flexible cable complete all as specified and as directed. (Make-Crompton cat part no LSTV-45-CDL or equivalent of BAJAJ/Havells)
S&F ceiling fan of sweep 1200 mm white colour,including all accessories, clamps wire etc. to hang the fan in position including provision of cable from ceiling rose to fan complete all as directed.(Make-Crompton Aura Plus -5 star or equivalent of BAJAJ/Havells)
S & F stepped type electronic fan regulator socket type type 400 W, 5 steps complete all as specified and directed.
S & F metal exhaust fan 300 mm sweep, with bird screen incl connecting up with provision of cable 0.5 sqmm twin core PVC insulated from ceiling rose/connector to fan of including fixing the fan frame to wall opening with suitable size rag bolts after drilling, making hole to wall as per size and making good complete all as specified and as directed. Make - Crompton Model - "Trans Air 12" or equivalent in Havells / Khaitan/Orient
M & L earthing complete with galvanised steel earth plate electrode 600X600X6 mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with the top edge of earth plate at depth not less than 1.5m below ground level connected with 4mm dia GI wire by means of bolts washers and protected by 15mm bore, medium grade GI pipe, funnel with 20mm bore GI medium grade watering pipe, wire mesh, copper lugs including concrete pit in PCC 1:3:6 type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350X350X50 mm, reinforced with 8mm dia deformed bars @15 cm C/C both direction and 10mm MS handle of suitable size, charcoal or coke and salt in alternate layers, necessary earth work in soft/loose soil, all as shown in Electrical Plate No 3 of MES Schedule Part-I and testing, complete all as specified and as directed.
M&L for sand cushioning for protection of cables (below, above and around the cable laid in trenches) complete using clean, dry sand complete all as specified and as directed.
Supply and laying well burnt bricks sub class 'B' laid breadth wise along length of cable in trenches after sand cushioning laid for underground cable protection complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/pole 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 10 Sqmm 2 core complete all as specified and as directed.
S&F 40 mm dia steel water tube light grade galvanised with all fittings and fixed complete laid in trenches complete all as specified and directed.
ROY CONSTRUCTION
NC BOSE AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .