Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹24.1 LAccepted-AOC | 1 | Accepted-AOC The lowest bidder M/s Sunshine Construction is being accepted please. | |
| 2 | 2nd₹25.2 L+₹22,684.50 (0.91%)Rejected-Finance SHOP NO 2 JANKI PLAZA BHAGWAN MAHAVIR PATH KOPARGAON AHMEDNAGAR MAHARASHTRA 423 601 | KOPARGAON | AHMEDNAGAR | MAHARASHTRA | 423601 | 2nd | Rejected-Finance L2 | |
| 3 | 3rd₹26.9 L+₹1.9 L (7.80%)Rejected-Finance 145H 2G AQAMA MODEL APARTMENT LUKERGANJ PRAYAGRAJ UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211001 | 3rd | Rejected-Finance L3 | |
| 4 | 4th₹27.7 L+₹2.7 L (10.6%)Rejected-Finance | 4th | Rejected-Finance L4 | |
| 5 | 5th₹28.4 L+₹3.4 L (13.8%)Rejected-Finance | 5th | Rejected-Finance L5 |
Tender Value
₹26.5 L
EMD Value
₹53,000
Closing Date
7 Mar 2024, 6:00 pmClosed
GE AWC MHOW
GE AWC MHOW
ADDN / ALTN OF OTM BLDG TCB-75 AND TCB-278 AT BSO YARD UNDER GE (AWC) MHOW
2024_MES_641552_1
8702 GE(AWC) /MHOW / OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE AWC MHOW
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
₹53,000
Yes
4 Apr 2024
9 Feb 2024
8 Mar 2024
10 Feb 2024
7 Mar 2024
23 Feb 2024
Amount
M & L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate including finishing surface of concrete topping even and rough complete as in levelling work etc complete all as specified and directed.
M & L 10 mm thick rendering in CM (1:3) mixed with integral water proofing chemical compound PIDIPROOF LW of DR FIXIT of PIDILITE INDUSTRIES LTD or STP No 1 (liquid) of STP Ltd @ 200 mililitre per 50 Kg cement as per manufacturers instructions over concrete surface and finishing the surface fair and even without using extra cement complete all as specified
M&L Water proofing treatment on "Non approachable / non accessible roof" surface (Horizontal & Vertical surfaces) in following sequence through authorized applicator of the manufacturer all as specified and directed complete including removal of existing treatment. (i) Surface prepration like opening the cracks/removal of loose concerete. (ii) Pressure washing the entire roof to remove dirt , dust alage fungi or other contaminants from joints and entire surface. (iii) Saturation of surface nano technology based deep penetrating sealer application to block pores , capillaries and micro cracks. (iv) Filling the crack with flexible polymer based caulk and further sealing with reinforcement fabric elastomeric coating. (v) Sealing joints and coving area with flexi reinforcement fabric and elastomeric coating. (vi) Priming coat of dr fixit URP with fiber mesh (vii) First and Second coat of elastomeric dr fixit Roof Seal . The authorized applicators are under :- (i) P Tech Solutions 92 Anurag Nagar Ring Road Indore (II) MR clean Ventures E-4/402 Arera Colony Bhopal 462016 (iii) Property care, 244 D scheme No 71 Near Shriji Vatika indore 452002 Note : A warranty of 10 years be provided by the contractor for the service rendered.
S & F 100 mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete .
S & F aluminium 200 mm long anodised barrel tower bolts ISI marked of extruded section and fixed complete.
S & F aluminium 150 mm long anodised barrel tower bolts ISI marked of extruded section and fixed complete.
S & F 150 mm size aluminium handles cast type, anodised ISI marked complete
S & F 250 mm aluminium alloy, anodised sliding door bolt ISI marked with hasp, staple (bolt type) and fixing clips of sheet, cast of extruded sections and fixing bolts and sliding bolts of extruded sec or cast aluminium and fixed complete.
S&F 1000 Ltrs capacity Triple layer rotational moulded polyethylene water storage tanks, (cylindrical vertical with closed top) hoisted and fixed in position including taking down, all as specified in SSR part I complete.
S&F in repair ball valve/float ball high pressure of PTMT 20mm with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed minimume weight 210 gm etc all as specified and directed.
Taking up or down existing steel tubing and connection complete for following sizes:-
(a) 15 mm bore
(b) 20 mm bore
Supplying, fixing, jointing and testing galvanised steel water tubing medium grade with all fittings such as bend, elbow, socket reducer etc fixed to walls and ceilings or laid in floors, complete for the following sizes: -
(a) 15mm dia bore
(b) 20 mm dia bore
Dismantling of floor hearth or wall tilling including cement mortar bedding (but not backing) and rubbish of the premisses complete all as specified and directed.
M&L non skid/mat finish ceramic colour tiles 7 to 8 mm thick(square/ rectagular) area of each tile exceeding 0.11 sq m but not exceeding 0.18 sqm (Colour and design of tiles as approved by GE), in floors/skirting etc, and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
M&L glazed ceramic coloured tiles size 300mm x 450 mm thick (Colour and design of tiles as approved by GE) on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M&L for PCC (1:3:6) type C-1 with using 20mm graded stone aggregate as in bed blocks, coping, for fixing holdfast/lugs,filling hollow space of pressed steel door frame etc including necessary form work all complete as specified and as directed.
M & L 2 nd class hard wood 35 mm thick Plain , framed panelled shutters ( any number of panels), with panels of timber flat on both sides (feather edged) or of veneered particle board medium density, wood particle board with commercial face veneers fitted to chowkats complete all as speciifed and directed.
S&F PVC waste pipe fixed to any type of coupling of 32 mm threaded complete all as specified and directed.
S & F in repair vitreous china Urinal , Half stall type white with waste pipe and union for discharge pipe (excluding flushing cistern,flush pipe) including spreader complete all as specified and as directed.
S&F 15 mm dia bore fancy type chromium plated swan neck pillar tap, cast copper alloy, with capstan heads, screwed down high pressure with long screwed shanks and fly-nuts, screwed for iron pipe and fixed, complete all as specified and directed.
S & F (in repair) brass chromium plated angle cock 15 mm bore screwed for iron pipe or brass ferrule, complete. Make : Plumber Cat No FLP-0507/Prayag Cat Part No 7810/ Jaquar Cat Part No CQT-23059 complete all as specified .
S & F in repairs vitreous china wash hand basin white, flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of tap, waste fitting etc complete.. Note :- Pillar tape shall be measured as supply only under respective item
S & F 105 x 60 mm size Pressed steel frames for door with one or more rebates including necessary lugs, hinges, lock strike plate,hold fast include etc., complete as specified
Dismantling timber scantlings unframed of any section , in any position complete all as specified.
M&L mild steel framed work such as grills , gratings, etc., with ends of bars shouldered and/ or riveted, or forged in to spikes; framed guard bars ; barred iron doors; ladders; framed balusters ; walk ways ; railings; frame work of water tanks and similar work conforming to Fe-290 Gde E-165 complete all as specified.
M & L Preparation of New wood or previously untreated surfaces of any description , not otherwise description, over 10 cm width or grith apply two coat of synthetic enemel paint (ordinary tint) over a coat of pink primer complete all as specifed and directed.
Dismantling of Single layer Mangalore pattern or similar tiles in roofing
Taking down chowkhats or frames not exc 1.5 sqm each without taking off shutter from the frame complete.
Taking down chowkhats or frame exc 1.5 sqm but not exc 4 sqm with shutter (without taking off shutter frome the frame )
S&F steel window with side hung shutter incl projecting hinge, fixing lugs, steel handle and steel peg stay complete with glazing bars.
S&F steel ventilator with top hung shutter with or without glazing bar, incl hinges, fixing lugs, steel peg stay, complete all as specified and as directed.
S & F in repairs PVC connection 15 mm dia 600 mm long with PTMT nuts at both ends complete all as specified and directed.
M&L Brick work with fly ash brick straight or curved on plan exc 6m mean radius built in cement mortar 1:6 including demolition of brick work complete all as specified and directed
M&L for rendering in cement mortar (1:6) 10mm thick first coat on fair faces of brick walls or concrete surfacesand in cm 1:4 5mm thick second coat over first coat , mixed with water proofing compound as per manufacturer instructions, finishe fair and even without using extra cement all complete as specified and as directed incl taking down existing plaster. Note : WPC shall be measured seperately.
Supply only Integral water proofing compound
M&L for rendering 10mm thick plastering in CM (1:6) finished even & fair all as specified incl taking down plaster.
M&L for rendering 5mm thick in CM 1:3 as in soffits of ceiling and Rcc cjhaja/ Facia roof projections finished fair & even all as specified incl taking down plaster
M&L for applying three coats of white washing on new plastered surfaces of ceiling including preparation complete all as specified and as directed.
Complete removal of old treatment on internal surfaces of wall by scrapping , and washing etc all as specified.
M&L for applying 1 mm Avg thick wall care putty on wall on internal old/new wall surfaces as per manufacturerer instruction complete all as specified and as directed
M & L for applying two coats of oil bound distemper over a coat of primer on prepared wall putty surfaces of internal wall all as per specified and directed.
M&L Two coats of exterior emulsion paint ( Apex ultima or weather coat) including 1 mm thick putty with primer , white or tinted on old/New surfaces of walls including prepration of old/New surfaces and washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified.
M & L for preparation of new or previously untreated steel surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over of redoxide zinc chrome coat complete all as specified and as directed.
S & F Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering, grill gate , Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (incl steel sheeting or other covering, also fastening and fixing complete.
S & F Joist channel, angle or tee, square or rectangular tubler sections fixed independently or as purlin, rafter or post incl cutting to dead length where required notching drilling firing riveting and/or welding or connecting with bolts and nuts providing and fitting angle cleats fish plates, gusset plates etc complete all as specified and directed (Fe-410-W (gde-E-250) quality A)
M &L for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, and eves board fixed with self tapping screws as specified including dismantling 0f existing sheets.
M & L Glass dividing strip, 3mm thik and 38mm width of strip completed as directed by Engg-in-charge
M &L for Pre-painted galvalume aluminium zinc coating GI based plain/corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, and eves board fixed with self tapping screws as specified .
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings
Demolition of cement concrete (un reinforced) in ground floor and paving n. exc. 15cm thickness (below or above ground level.
M&L for PCC 1:3:6 type C2 using 40mm graded aggregate 75mm thick as in plinth protection, finished concrete surfaces even and smooth without using extra cement
M & L 60 mm thick Machine pressed precast concrete interlocking paver blockfixing with grey cement and pigments OF " I " shape or as approved by GE ,and any colour and size confirming to IS 15658-2006 of M-35 Grade set , laid over 50 mm (average) thick dust sand cushioning,filling of joints with sand & compaction using surface vibrator after filling of joints laind in any pattern as decided by Engineer-In-Charge including packing of sides by cement concrete finishing surfce even and smooth complete all as specified and as directed including demolition .
M & L 75 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base for pavement , path, floor etc complete all as specified and directed.
M&L PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation, sub base / mass concrete etc. complete.
S&F wind-driven turbo ventilator with matching fiberglass reinforced plastic FRP base plate self lubricated bearing of 2 Nos turbine doom thickness 1mm, turbine outer dia 630mm(min.) turbine doom dia 380 mm(min.) and height 480mm(min.)
Taking down copper /aluminium point wiring (light, fan, bell, socket or power) complete including fixture and fittings such as switches, ceiling rose, pendent, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition separately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed at site.
Taking down ceiling fan/ exhaust fan/ wall fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of concerned AGE E/M complete all as specified and as directed.
Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed.
Taking down old / unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC FRLS concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches and blank plates, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :-
(a) One light point controlled by one, one way switch 5 Amps
(b) One fan point/ wall fan/exhaust fan point controlled by one, one way switch 5 Amps and regulator
(c) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
(d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board.
(e) One bell point controlled by one, bell switch 5 Amps
Description all as per item No. 6 here in before but using 2.5 sq. mm single core copper conductor cable of multistranded FRLSH PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including necessary running of 2.5 sq. mm copper conductor FRLSH PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly.
S & F for Modular Switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified.
S & F for Modular Switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified.
S & F for Modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified.
S & F for Modular Socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified.
S & F for modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed.
S & F for Bell push modular 6 Amps single module complete all as specified.
S & F for Ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified
S & F for Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq. mm nominal area and drawing into suitable size of PVC FRLS non metallic rigid heavy duty conduit of white/ ivory colour and its accessories ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 Sqmm cable, one run of 6 Sqmm cable and one run of PVC conduit will be measured as one unit
M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLSH cable with stranded copper conductor of size 4 Sq. mm nominal area and drawing into suitable size of PVC FRLS non metallic rigid heavy duty conduit of white/ ivory colour and its accessories ISI marked heavy duty of suitable size including concealed in wall etc two run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Four runs of 4 Sqmm cable, two run of 4 Sqmm cable and one run of PVC conduit will be measured as one unit
M&L for Triple pole and earth enclosure with a three pin and earth plug with socket 415 Volts, 50 Hz complete with one triple pole MCB TP 32 Amps, and of the same make as above item complete all as specified and directed.
Supply and fixing surface /wall mounted LED batten poly carbonate housing for retrofit LED tube T-8 type upto 1x20 watt, 4 feet long pre wired incl integrated electronic driver complete with all connected accessories all as specified and directed. Make :Havells/ Bajaj / Philips as approved by GE.
Supply and fixing retrofit LED tube T-8 type 1x20 watt, 5700 to 6500 K and THD less than 15% , polycarbonate body ,glass tube 4 feet long complete with 02 years warrenty all as specified and directed. Make :Havells / Bajaj / Philips as approved by GE.
M&L for angle holder modular type poly carbonite body complete all as specified and directed.
M&L for LED Bulk head fitings 6.5 watts designed for modern homes available with premium quality diffuser for glarefree light and easy to install snapfit installer complete including taking down of old CFL/bulb bulk head fitting, making good of surfaces all as specified and directed. Make: Havells/Philips/Bajaj
S & F LED bldg security light fitting 30 watt made up of pressure die cast aluminium housing with acylic cover as diffuser with IP-66 protection complete with GI mounting pipe 40 mm size 1 Mtr length bend into sizes duly fixed on wall with suitable sadles, screws, incl flexible connecting wires from ceiling rose to connector of fitting all as specified and directed.
S&F MCCB ,DB VTPN wall mounted double door 4 way 415 volts with facility to provide MCCB 3 pole 125 Amps 25 KA as incomer and SP/TP MCB's/Isolator as outgoing including removed old U/S DB in the wall again fixing the new DB and wall finising complete all as specified and as directed
S&F MCB DB SPN 8 way double door , IP 43, IK-09 with 200 Amps rated bus bar ,230 volts, 50 Hz complete all as specifed and directed.
S&F MCCB 3 pole 415 V 125 A Hz , Ics=100% Icu with rupturing capacity 25KA.
Supply & Fix MCB TP 63 Amps current rating 'C' series 10 KA breaking capacitycomplete all as specified and directed.
Supply & Fix MCB SPN 40 Amps current rating 'C' series 10 KA breaking capacitycomplete all as specified and directed.
Supply & Fix MCB SP 6 to 32 Amps current rating 'C' series 10 KA breaking capacitycomplete all as specified and directed.
Labour only for refixing the ceiling fan/ Exhaust fan obtained from item No 2 above with replacement of unsv 3 core PVC insulated PVC sheathed 3 core multistranded copper conductor cable of size 23/ 0.193 from ceiling rose to fan terminal including over hauling the fan, painting of ceiling fans complete with two coats synthetic enamel paint by spraying including filling cavities with filler after cleaning all dust etc and writing the MES Number with synthetic enamel paint complete all as specified and as directed.
S & F for energy efficient exhaust fan of 450 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base including writing the MES Number with synthetic enamel paint complete all as specified and directed. Note :- Cost of suitable opening wall for fixing exhaust fan is deemed to be included in overall rate quoted).
S&F fan regulator stepped electronic, modular type 02 module as specifed and directed.
M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type of soil/strata and testing on completion. Note :- GI earth wire 4 mm dia and 15 mm dia protection pipe up to 7.5 mtr from earth plate is deemed to be included in rate quoted.
sunway associates
yash enterprises
Goyal Construction
J B CONSTRUCTION AND DEVLOPERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .