Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹1.5 Cr
EMD Value
₹2.9 L
Closing Date
26 Oct 2026, 3:00 pm7d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
CCE R N D ESTATES NORTH CHANDIGARH
CCE R N D ESTATES NORTH M-1026 Sector- 29A, Chandigarh - 160030
MnO of Elect. Water Supply, HVAC, RO Plants, STP Plant inst. DRDO TF, Sply of Potable Water, Trials Teams at AFFRU, Clearance, Clearing of Desert Sand from Boundary Wall, CAMC of EPABX, Online UPS systems inst. at DRDO GH and TF at Chandan Range
2026_DRDO_930415_1
CCE(EN)/DEL/OM-06/CHANDAN/ 26-27/9106
Open Tender
Miscellaneous Works
Percentage
365 days
Chandan Range
All agencies enlisted with DCWE under Composite Class-III/ Class-II/ Class-I / Class-I(A) / Class-I(AA) / Class-I(AAA) / Class-I(Super) AND Estate Management and Maintenance (DRDO-2024) BIM-III, BIM-II, BIM-I class as perAppx C NIT
5 documents required · 5 mandatory
₹0
₹2.9 L
CCE R N D ESTATES NORTH CHANDIGARH
14 Oct 2026
14 Oct 2026
28 Oct 2026
14 Oct 2026
26 Oct 2026
19 Oct 2026
16 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Part - A (PERCENTAGE TO BE QUOTED ON THIS AMOUNT ONLY WHICH IS INCLUSIVE OF CP&OH)
"Maintenance and Operation of Electrical, Water Supply and HVAC, RO Plants, STP Plant installations including day to day maintenance of various DRDO Transit Facilities at Chandan Range and Supply of Potable Water for day to day use of DRDO TF and Trials Teams at AFFRU Chandan and Clearance & Clearing of Desert Sand from Boundary Wall of DRDO Transit Facility at AFFRU Chandan Range and Comprehensive Annual Maintenance of EPABX and Online UPS systems installed at various DRDO guest houses and Transit Facilities at Chandan Range" by providing following Manpower :-
(i) Supervisor Cum Sr Electrician (Highly - Skilled) - 01 No
(ii) Electrician cum Heating plant operator cum DG Set operator / Boiler Operator (Skilled) - 05 No
(ii) Plumber/Pump Opertator (Skilled) - 02 No
(iv) Sewarman (Un Skilled) - 01 No
(v) Support Staff (Un Skilled) - 04 No
Total 13 Nos
Operation and Maintenance of Equipment/ Installation at Site and provision of maintenance services by positioning required manpower as per the scope of work (Refer Appendix-A of NIT) for 12 (Twelve) Months and as per direction of Engineer-in-Charge. The following points mentioned under "Note" from Sl No. (i) to (iiii) shall be considered while quoting the rate (Refer Appendix-B of NIT for details).
NOTE:
(i) The estimated cost is inclusive the following:-
(a) The Current Minimum Fair Wages of the above Manpower (Refer to Letter No. F. No. 1/6(3)/2025-LS-II of office of Chief Labour Commissioner (C), Dated : 30 Mar 2026).
(b) For remote/bad climate area: Additional Special Pay for Highly Skilled @3500, Skilled @3000PM and Un-Skilled @2500PM Per Person.
(c) EPF (Employer’s share only) – 13.00% (But not on more than ceiling limit of wages prescribed by EPFO i.e, presently restricted to Rs 25000/-) vide gazette notification No. SO5109(E) dated 17 Sep 2026
(d) ESI (Employer’s share only) – 3.25% (only for employees whose total monthly wages is less than or equal to </=Rs 21000/-). For employees having salary more than Rs. 21,000/- per month Group Health Insurance shall be provided out of CP & OH being quoted by contractor.
(e) Bonus @ 8.33% per month (only for employees whose total monthly wages is less than or equal to </=Rs 21000/-)
(ii) The bidder shall quote (%) percentage above : More than or equal to 5% (Five) percent charges (upto two decimal) over estimated cost of tender for services charges/contractor profit and overhead. If the bidder/firm quotes less than 5% charges, the bid shall be treated as unresponsive and will not be considered for acceptance. No representation in this regard will be entertained.
(iii) However, Only the actual variation in VDA (Increase / Decrease) during contract period and extended period as applicable as notified by Chief Labour Commissioner, Ministry of Labour and Employment, Govt. of India shall be paid seperately as per actual alongwith associated EPF/ESI and Applicable GST on above increased amounts.
(iv) Any variation in the above elements promulgated by the government from time to time shall be paid or deducted accordingly.
Cont... 1.01 | 12 | Months | 3,48,743.18 | ₹41,84,918.16 |
| 1.01 | GST @18% on Part - A amount Rs. 41,84,918.16 | 12 | Months | 62,773.77 | ₹7,53,285.24 |
| 2 | Part - B (PERCENTAGE NOT TO BE QUOTED ON THIS AMOUNT)
Uniform and Accessories: Two sets of normal Uniforms (Shirt & Trouser duly engraved name of particular company on the left pocket of Shirt as approved by Estate Manager) to each and every manpower including Shoes/Boots/Protective Gear/Gloves and winter clothing etc. as applicable to all O&M Staff @ Rs 4720.00 per annum per head.
NOTE:
i) The amount will be reimbursed/ paid against actual expenditure made (restricted to the estimate amount on not exceedable basis) on submission of paid vouchers submitted by contractor of payments duly defaced by Engineer-in-charge / Project Manager to the con-cerned authorities.
ii) The Amount is inclusive of CP & OH, GST@18% will be paid i.e. Rs. 4720.00 Refer Appendix - B. | 13 | Per Person | 4,720 | ₹61,360 |
| 3 | Part – C : Comprehensive Maintenance of fol-lowing split/window type air condi-tioners including voltage stabilizer by replacement spare parts like, thermo-stat, filter pads, contractors, capaci-tors relays, control wiring complete, gas charging, PCB etc for smooth functioning of equipment's as per in-structions of Engineer-in-Charge :-
Old OTF
1.5 TR Split AC 12 Nos Make LG/Voltas/Bluestar
2.0 TR Split AC 24 Nos Make LG/Voltas/Bluestar
New OTF
1.5 TR Split AC 5 Nos Make LG/Voltas/Bluestar
2.0 TR Split Unit AC 25 Nos Make LG/Voltas/Bluestar
CORE TECHNICAL SPECIFICATION OF 1.5 Ton Split AC.
Cooling Capacity 5000 W- 5280 W (1.5 TR)
Compressor type : Variable-Speed Inverter Rotary Compressor (modulates capacity based
on room load to save power)
Refrigerant : Eco-Friendly R-32 (Ozone-non-depleting or (R410A)
Condenser & Evaporator Coils : 100% Copper with anti corrosive/blue-fin coatings for
better durability.
Power Supply : 230V, 50Hz , Single Phase AC Input
Energy Ratings : (BEE/ISEER) Available in 3- Star or 5 Star models, ISEER values
generally range from 4.5 to 5.8 W/W depending on the brand and model year
2.0-ton split air conditioner
Core Specifications :
Cooling Capacity: ~ 24,000 BTU/h (or ~ 6,100 Watts)
Star Ratings: Available in 3-Star or 5-Star BEE energy ratings (depending on brand and ISEER value)
Airflow: ~ 720 CFM (Cubic Feet per Minute) for quick, widespread air circulation
Key Technologies
Compressor Type: Rotary Inverter Compressor (adjusts speed automatically to main-tain room temperature)
Convertible Modes: Many models feature AI convertible technology (4-in-1 to 7-in-1) allowing you to drop the tonnage (e.g., to 1.5 tons) for energy savings.
Condenser Type: 100% Copper with Anti-Corrosion / Blue-Fin protection for better heat exchange and rust prevention.
Conti... 3.01 | 4 | Per Quarter | - | - |
| 4Part – D : DG Set of capacity 250 KVA : 02 Nos (PERCENTAGE NOT TO BE QUOTED ON THIS AMOUNT) (a) Specifications of DG Set of capacity 250 KVA: Make: Cummins Ser No: 25244002 Rating:250 KVA Phase: 3 Phase Voltage: 415 Volts Frequency: 50 Hz (b) Specifications of DG Set of capacity 250 KVA: Make: Cummins Ser No: 25167009 Rating:250 KVA Phase: 3 Phase Voltage: 415 Volts Frequency: 50 Hz | |||||
| 4.01 | Periodical Maintenance/Services: B check and C Check of 250 KVA 02 Nos DG Set as per Appx.- 'G'. (PERCENTAGE NOT TO BE QUOTED ON THIS AMOUNT)
NOTE:
i) This amount is fixed and inclusive of CP&OH and GST@18%.
ii) The amount will be reimbursed/ paid against actual expenditure made (restricted to the estimate amount on not exceedable basis) on submission of paid vouchers submitted by contractor of payments duly defaced by Engineer-in-charge / Project Manager to the con-cerned authorities.
(iii) Refer Para 2 of Appendix 'A' & 'G' of NIT for Scope of Work for B Check / C Check of DG set. | - | - | - | - |
| 4.011 | 250 KVA DG Set: (02 Nos. DG Sets) ( 01 No of B Check & 01 No of C Check for each DG Set)
Scope of work : 'B' Check of DG Sets upto the time of 500 Hrs / 6 Months whichever comes earlier with including the activity like changing of Fuel Filter, Lube Oil Filter, Separator, Fuel Water, Premix Coolent, Engine Oil, Corrosion inhibitor etc. as per OEM Standrads and direction of Engineer-in-charge.
Scope of work : 'C' Check -of DG Sets upto the time of 1500 Hrs / 1 Year whichever comes earlier with including the activity like Fuel Filter, Lube Oil Filter, Separator, Fuel Water, Premix Coolent, Engine Oil, Corrosion inhibitor, Air Cleaner, Gaskets, Valve cover, V- belt, cleaning of radiator, pressure pump cleaning with ready wash treatment to cleaning inside the radiator & Engine cooling System, checking oil and water leakages of radiator on load, Fuel tank cleaning etc. as per OEM Standrads and direction of Engineer-in-charge.
Note:-
(i) B-Check maintenance of Diesel Generator (DG) Sets shall be carried out by the Original Equipment Manufacturer (OEM) or its authorized service representatives or any expert agency as approved by the CCE as per recommendations of Estate Manager.
(For detail refer to Appendix-A & G of NIT).
(ii) C-Check maintenance of Diesel Generator (DG) Sets shall be carried out by the Original Equipment Manufacturer (OEM) or its authorized service representatives or any expert agency as approved by the CCE as per recommendations of Estate Manager.
(For detail refer to Appendix-A & G of NIT). | 2 | Per An-num / Per Each DG Set | 1,30,945.78 | ₹2,61,891.56 |
| 5 | Part -E : Comprehensive Maintenance of following
Transformer 500 KVA Make Esennar (Sr. No. ET2-5075)
a) 11KV/0.433KV 500KVA Transformer.
b) Earthing System with Earth Strip
Specifications of 11KV/0.433KV 500KVA Transformer:
Capacity: 500 KVA
Make: Esennar
Ser No: ET2-5075
Type of cooling: ONAN
Phase: 3 Phase
Voltage: 11 KV/433V
Frequency: 50 Hz
NOTE:
i) The overall amount earmarked for expenditure in this head is Rs. 19,776.00 including CP&OH and @ 18% GST.
ii) Payment will be made @ Rs. 4,944.00 per quarter for CAMC of above mentioned item as per payment term give at Para 30 (i) (iii) of Terms conditions given at Appendix 'D'
iii) The payment against this Sub-Head of BOQ is to be claimed on Quarterly basis along with service report of OEM / Authorised vendor of OEM / Any other Expert Agency as approved by CCE based on recommendations of Estate Manager. The bill will be submitteed along with certificate by agency that all items are serviceable duly countersigned by Estate Manager. Any item requires repairs are to be reported in a complaint register by the TF staff and response time of Agency to be recorded and maintained by Estate Manager or his Authorised Rep. Penalty to be levied for delay in repairs @ Rs 500 per day beyond an acceptable time for repairs as decided by Estate Manager.
iv) Agencies are instructed to visit the site and assess the status of machine / equipment / appliances etc. before submission of their Quoted Tender. Any representations in this regard shall not be entertained after Pre-Bid Meeting. However, the department has to ensure that all items covered under CAMC are in functional condition. If any machine / equipment / appliances are found Non-functional before start of CAMC during handing /taking over between two Contractors, the same shall be rectified through running Contract by the concerned Agencies as per his Scope of work before handing over and if the same is not under the Scope of running Contract, it shall be rectified through Prime Cost Sum of new Contract and after repairs only, CAMC of particular machine / equipment / appliances shall start and consider for payment. | 4 | Per Quarter | - | - |
| 6Part-F Technical Specifications Capacity: 12,000 LPH (Liters Per Hour) Make AZTECK Purification Technology: Multi-stage pre-filtration + Reverse Osmosis + optional post-treatment (UV, Ozone, or UF) TDS Reduction: Up to 95% – 99% (depending on feed water quality) Water Recovery Rate: 50% to 75% Number of RO Membranes: Typically 8 to 15 high-rejection thin-film composite (TFC) membranes Material of Construction (MOC): Available in FRP (Fiber-reinforced plastic), SS 304, or SS 316 stainless steel skid frames Power Requirement: 10 to 15 HP (or roughly 380V–440V, 3-phase, 50 Hz AC power supply; larger mineral water configurations can draw up to ~58.5 kW) Automation Grade: Fully automatic or semi-automatic with microprocessor/PLC control panels . Standard Process Flow & Components Raw Water Feed Pump & Tank: Handles initial intake and maintains system hydraulic pressure. Multi-Grade Sand Filter (MGF): Removes suspended solids, turbidity, and physical particulates. Activated Carbon Filter (ACF): Absorbs free chlorine, bad odors, and organic chemicals. Antiscalant Dosing System: Injects inhibitors to prevent mineral scaling on the membranes. Micron Cartridge Filters: Catches fine micro-debris before high-pressure pumping. High-Pressure Pump & RO Skid: Forces water through the membrane assemblies. Post-Treatment: UV sterilization or Ozonation for microbiological safety. Note : a) The pre-priced list of spares including OH & CP @ 10% and 18% GST is given below. b) The amount will be reimbursed/ paid against actual expediture made (restricted to the estimate/ eligible amount) on submission of paid vouchers submitted by contractor of payments duly defaced by Engineer-in-charge / Project Manager to the concerned authorities subject to rates given in pre-priced list. iv) The list of spares is not exhaustive the associated accessories of the above listed E/M assets as per Appendix - 'H' are also to be maintained under this contract as a part of scope of work. | |||||
| 6.01 | Consumables for RO Plant Maintenance : | - | - | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.75 MB
GCC2023.pdf
Additional Documents • 5.78 MB
MFW.pdf
Additional Documents • 0.45 MB
BOQ_977718.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .