Loading…
Loading…
Tender Value
₹2.7 Cr
EMD Value
₹2.9 L
Closing Date
4 Feb 2026, 3:00 pmClosed
At TSK Division-Construction of indoor stadium and other miscellaneous repair works in connection with Upgradation of sports amenities in stadium at Hijuguri Rly colony.
01-TSK-ENGG-04-2026~NFR
01-TSK-ENGG-04-2026
Open
Works - General
12 Months
Uttara Kannada, Karnataka
₹0
₹2.9 L
4 Feb 2026
13 Jan 2026
21 Jan 2026
A-Construction of indoor stadium and other miscellaneous repair works
Upgradation of sports amenities in stadium at Hijuguri Rly colony.
Item- 1 CPWD ITEMS
S No. Item No Description of Item Unit Qty Rate Amount
2.0 EARTH WORK
Earth work in excavation by mechanical means
(Hydraulic excavator)/manual means over
areas (exceeding 30 cm in depth, 1.5 m in
2.6 width as well as 10 sqm on plan) including
getting out and disposal of excavated earth
lead upto 50 m and lift upto 1.5 m, as directed
by Engineer-in-charge.
2.25A Excavating, supplying and filling of local earth cum 420 368.65 154833
(including royalty) by mechanical transport
upto a lead of 5km also including ramming and
watering of the earth in layers not exceeding 20
cm in trenches, plinth, sides of foundation etc.
TINSUKIA DIVISION-ENGINEERING/N F RLY
2.27 Supplying and filling in plinth with sand under cum 1235 2161.2 2669082
3 floors, including watering, ramming,
consolidating and dressing complete.
4.0 CONCRETE WORK
4.1S CEMENT CONCRETE (CAST IN SITU)
Providing and laying in position cement
concrete of specified grade excluding the cost
of centering and shuttering - All work up to
derived from natural sources : 3 graded stone
aggregate 20 mm nominal size derived from
natural sources)
derived from natural sources : 4 graded stone
aggregate 20 mm nominal size derived from
natural sources)
derived from natural sources : 4 graded stone
aggregate 40 mm nominal size derived from
natural sources)
derived from natural sources: 6 graded stone
aggregate 40 mm nominal size derived from
natural sources)
4.10S DAMP-PROOF COURSE
4.11 Providing and laying damp-proof course 50mm Sqm 520 452.25 235170
thick with cement concrete 1:2:4 (1 cement : 2
8 coarse sand(zone-III) derived from natural
sources : 4 graded stone aggregate 20mm
nominal size derived from natural sources).
5.0 REINFORCED CEMENT CONCRETE
5.9S FORM WORK
Centering and shuttering including strutting,
propping etc. and removal of form for
5.9.1 Foundations, footings, bases of columns, etc. Sqm 250 307.95 76987.5
for mass concrete
5.9.2 Walls (any thickness) including attached Sqm 350 669.55 234342.5
10 pilasters, butteresses, plinth and string courses
5.9.3 Suspended floors, roofs, landings, balconies Sqm 1250 766.55 958187.5
and access platform
5.9.5 Lintels, beams, plinth beams, girders, Sqm 450 608.35 273757.5
bressumers and cantilevers
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Sqm 510 804.25 410167.5
5.12S PRE-CAST RCC
5.12 Providing, hoisting and fixing above plinth level cum 2 9673.5 19347
up to floor five level precast reinforced cement
concrete work in string courses, bands, copings,
bed plates, anchor blocks, plain window sills
and the like, including the cost of required
centering, shuttering but , excluding cost of
reinforcement with 1:1.5:3 (1 cement : 1.5
coarse sand(zone-III) derived from natural
sources : 3 graded stone aggregate 20 mm
nominal size derived from natural sources).
5.22S STEEL REINFORCEMENT
Steel reinforcement for R.C.C. work including
straightening, cutting, bending, placing in
position and binding all complete upto plinth
5.22.6 Thermo-Mechanically Treated bars of grade Fe- Kg 8200 89.65 735130
TINSUKIA DIVISION-ENGINEERING/N F RLY
Steel reinforcement for R.C.C. work including
straightening, cutting, bending, placing in
position and binding all complete above plinth
5.22A.6 Thermo-Mechanically Treated bars of grade Fe- Kg 23500 89.65 2106775
5.33S DESIGN MIX CONCRETE
Providing and laying in position ready mixed or
site batched design mix cement concrete for
reinforced cement concrete work; using coarse
aggregate and fine aggregate derived from
natural sources, Portland Pozzolana / Ordinary
Portland /Portland Slag cement, admixtures in
recommended proportions as per IS: 9103 to
accelerate / retard setting of concrete, to
improve durability and workability without
impairing strength; including pumping of
concrete to site of laying, curing, carriage for all
5.33 leads; but excluding the cost of centering,
shuttering, finishing and reinforcement as per
direction of the engineer-in-charge; for the
following grades of concrete. Note: Extra
cement up to 10% of the minimum specified
cement content in design mix shall be payable
separately. In case the cement content in
design mix is more than 1.10 times of the
specified minimum cement content, the
contractor shall have discretion to either re-
design the mix or bear the cost of extra
5.33.1 All works upto plinth level
5.33.1.1 Concrete of M25 grade with minimum cement cum 42 8683.8 364719.6
content of 330 kg /cum
5.33.2 All works above plinth level upto floor V level
5.33.2.1 Concrete of M25 grade with minimum cement cum 115 10306.2 1185213
content of 330 kg /cum
5.35 Add for using extra cement in the items of Quintal 320 688.45 220304
19 design mix over and above the specified
cement content therein.
6.0 MASONRY WORK
Brick work with common burnt clay F.P.S. (non
6.1 modular) bricks of class designation 7.5 in
foundation and plinth in:
Brick work with common burnt clay F.P.S. (non
modular) bricks of class designation 7.5 in
superstructure above plinth level up to floor V
level in all shapes and sizes in :
6.12S HALF BRICK MASONRY
Half brick masonry with common burnt clay
F.P.S. (non modular) bricks of class designation
7.5 in superstructure above plinth level up to
8.0 CLADDING WORK
TINSUKIA DIVISION-ENGINEERING/N F RLY
Providing and fixing 18 mm thick gang saw cut,
mirror polished, premoulded and prepolished,
machine cut for kitchen platforms, vanity
counters, window sills, facias and similar
locations of required size, approved shade,
colour and texture laid over 20 mm thick base
cement mortar 1:4 (1 cement : 4 coarse sand),
joints treated with white cement, mixed with
matching pigment, epoxy touch ups, including
rubbing, curing, moulding and polishing of
edges to give high gloss finish etc. complete at
Granite stone slab of colour black, Cherry/Ruby
8.20S STONE WORK DRY CLADDING
8.31 Providing and fixing Ist quality ceramic glazed Sqm 50 1063.45 53172.5
wall tiles conforming to IS: 15622 (thickness to
be specified by the manufacturer), of approved
make, in all colours, shades except burgundy,
bottle green, black of any size as approved by
25 Engineer-in-Charge, in skirting, risers of steps
and dados, over 12 mm thick bed of cement
mortar 1:3 (1 cement : 3 coarse sand) and
jointing with grey cement slurry @ 3.3kg per
sqm, including pointing in white cement mixed
with pigment of matching shade complete.
9.0 WOOD AND P.V.C. WORK
9.1S FRAMES AND TRUSSES
Providing wood work in frames of doors,
windows, clerestory windows and other frames,
wrought framed and fixed in position with hold
fast lugs or with dash fasteners of required dia
& length (hold fast lugs or dash fastener shall
be paid for separately).
9.1.3 Kiln seasoned and chemically treated hollock cum 2 74199.7 148399.4
Providing and fixing 25 mm thick shutters for
cup board etc. :
Providing and fixing ISI marked flush door
shutters conforming to IS : 2202 (Part I) non-
decorative type, core of block board
9.21 construction with frame of 1st class hard wood
and well matched commercial 3 ply veneering
with vertical grains or cross bands and face
veneers on both faces of shutters:
9.21.1 35 mm thick including ISI marked Stainless Sqm 30 2015.75 60472.5
Steel butt hinges with necessary screws
9.40S MISCELLANEOUS-WOOD WORK
Providing and fixing M.S. grills of required
pattern in frames of windows etc. with M.S.
9.48 flats, square or round bars etc. including
priming coat with approved steel primer all
9.48.2 Fixed to openings /wooden frames with rawl Kg 620 197.7 122574
plugs screws etc.
Providing and fixing fly proof galvanized M.S.
wire gauge to windows and clerestory windows
9.51 using wire gauge with average width of
aperture 1.4 mm in both directions with wire of
dia 0.63 mm all complete.
9.72S BRASS FITTINGS
TINSUKIA DIVISION-ENGINEERING/N F RLY
9.76 Providing and fixing bright finished brass 100 Each 20 723.8 14476
mm mortice latch and lock with 6 levers and a
pair of lever handles of approved quality with
necessary screws etc. complete.
9.84 Providing and fixing aluminium extruded Each 20 856.3 17126
section body tubular type universal hydraulic
door closer (having brand logo with ISI, IS :
3564, embossed on the body, door weight upto
36 kg to 80 kg and door width from 701 mm to
1000 mm), with double speed adjustment with
necessary accessories and screws etc.
ANODISED ALUMINIUM FITTINGS (ALL FITTINGS
SHALL BE ISI MARKED)
Providing and fixing ISI marked aluminium butt
hinges anodised (anodic coating not less than
9.95 grade AC 10 as per IS: 1868) transparent or
dyed to required colour or shade with
necessary screws etc. complete:
Providing and fixing aluminium sliding door
bolts, ISI marked anodised (anodic coating not
9.96 less than grade AC 10 as per IS : 1868),
transparent or dyed to required colour or
shade, with nuts and screws etc. complete :
Providing and fixing aluminium tower bolts, ISI
marked, anodised (anodic coating not less than
9.97 grade AC 10 as per IS : 1868 ) transparent or
dyed to required colour or shade, with
necessary screws etc. complete :
Providing and fixing aluminium handles, ISI
marked, anodised (anodic coating not less than
9.100 grade AC 10 as per IS : 1868) transparent or
dyed to required colour or shade, with
necessary screws etc. complete :
Providing and fixing aluminium hanging floor
door stopper, ISI marked, anodised (anodic
coating not less than grade AC 10 as per IS :
1868) transparent or dyed to required colour
and shade, with necessary screws etc.
9.104 Providing and fixing aluminium tee channels Metre 120 139.7 16764
39 (heavy duty) with rollers & stop end in pelmets
as curtain rod.
9.105S GYPSUM BOARD PARTITIONS
Providing and fixing wire gauge shutters using
stainless steel grade 304 wire gauge with wire
9.134 of dia 0.5 mm and average width of aperture
1.4 mm in both directions for doors, windows
and clerestory windows with necessary screws :
TINSUKIA DIVISION-ENGINEERING/N F RLY
Providing and fixing factory made uPVC white
colour fixed glazed windows/ventilators
comprising of uPVC multi-chambered frame and
mullion (where ever required) extruded profiles
duly reinforced with 1.60 +/- 0.2 mm thick
galvanized mild steel section made from roll
forming process of required length (shape &
size according to uPVC profile), , uPVC extruded
glazing beads of appropriate dimension, EPDM
gasket, G.I fasteners 100 x 8 mm size for fixing
frame to finished wall, plastic packers, plastic
caps and necessary stainless steel screws etc.
Profile of frame shall be mitred cut and fusion
welded at all corners, mullion (if required) shall
be also fusion welded including drilling of holes
for fixing hardware's and drainage of water etc.
After fixing frame the gap between frame and
adjacent finished wall shall be filled with
weather proof silicon sealant over backer rod of
required size and of approved quality, all
complete as per approved drawing & direction
of Engineer-in-Charge. (Single / double glass
panes and silicon sealant shall be paid
separately). Variation in profile dimension in
higher side shall be accepted but no extra
payment on this account shall be made.
9.147B.1 Fixed window / ventilator made of (small series) Sqm 8 7249.9 57999.2
frame 47 x 50 mm & mullion 47 x 68 mm both
40 having wall thickness of 1.9 +/- 0.2 mm and
single glazing bead of appropriate dimension.
(Area upto 0.75 sqm.)
Providing and fixing factory made uPVC white
colour sliding glazed window upto 1.50 m in
height dimension comprising of uPVC multi-
chambered frame with in-built roller track and
sash extruded profiles duly reinforced with 1.60
+/- 0.2 mm thick galvanized mild steel section
made from roll forming process of required
length (shape & size according to uPVC profile),
appropriate dimension of uPVC extruded
glazing beads and uPVC extruded interlocks,
EPDM gasket, wool pile, zinc alloy (white
powder coated) touch locks with hook, zinc
alloy body with single nylon rollers (weight
bearing capacity to be 40 kg), G.I fasteners 100
9.147D x 8 mm size for fixing frame to finished wall
and necessary stainless steel screws etc. Profile
of frame & sash shall be mitred cut and fusion
welded at all corners, including drilling of holes
for fixing hardware's and drainage of water etc.
After fixing frame the gap between frame and
adjacent finished wall shall be filled with
weather proof silicon sealent over backer rod of
required size and of approved quality, all
complete as per approved drawing & direction
of Engineer-in-Charge. (Single / double glass
panes, wire mesh and silicon sealent shall be
paid separately). Variation in profile dimension
in higher side shall be accepted but no extra
payment on this account shall be made.
9.147D.1 Two track two panels sliding window made of Sqm 15 7634.1 114511.5
(small series) frame 52 x 44 mm &sash 32 x 60
41 mm both having wall thickness of 1.9 +/- 0.2
mm and single glazing bead of appropriate
dimension. (Area of window upto 1.75 sqm)
TINSUKIA DIVISION-ENGINEERING/N F RLY
9.147D.2 Three track three panels sliding window with fly Sqm 50 10030.3 501515
proof SS wire mesh (Two nos. glazed & one no.
wire mesh panels) made of (small series) frame
42 92 x 44 mm & sash 32 x 60 mm both having
wall thickness of 1.9 +/- 0.2 mm and single
glazing bead of appropriate dimension (Area of
window upto 1.75 sqm).
10.0 STEEL WORK
10.2 Structural steel work riveted, bolted or welded Kg 1645 111.95 184157.75
in built up sections, trusses and framed work,
43 including cutting, hoisting, fixing in position and
applying a priming coat of approved steel
primer all complete.
Steel work in built up tubular (round, square or
rectangular hollow tubes etc.) trusses etc.,
including cutting, hoisting, fixing in position and
applying a priming coat of approved steel
primer, including welding and bolted with
special shaped washers etc. complete.
10.28 Providing and fixing stainless steel ( Grade 304) Kg 1210 612.25 740822.5
railing made of Hollow tubes, channels, plates
etc., including welding, grinding, buffing,
polishing and making curvature (wherever
required) and fitting the same with necessary
stainless steel nuts and bolts complete, i/c
fixing the railing with necessary accessories &
45 stainless steel dash fasteners , stainless steel
bolts etc., of required size, on the top of the
floor or the side of waist slab with suitable
arrangement as per approval of Engineer-in-
charge, (for payment purpose only weight of
stainless steel members shall be considered
excluding fixing accessories such as nuts, bolts,
fasteners etc.).
11.0 FLOORING
Cement concrete flooring 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate)
11.3 finished with a floating coat of neat cement,
including cement slurry, but excluding the cost
of nosing of steps etc. complete.
11.3.1 40 mm thick with 20 mm nominal size stone Sqm 480 545 261600
11.41S VITRIFIED FLOOR TILES
Providing and laying Vitrified tiles in floor in
different sizes (thickness to be specified by the
manufacturer) with water absorption less than
0.08% and conforming to IS:15622, of approved
brand & manufacturer, in all colours and shade,
laid on 20 mm thick cement mortar 1:4 (1
cement: 4 coarse sand) jointing with grey
11.41A cement slurry @3.3 kg/sqm including grouting
t h e joints with white cement and matching
pigments etc. The tiles must be cut with the
zero chipping diamond cutter only . Laying of
tiles will be done with the notch trowel, plier,
wedge, clips of required thickness, leveling
system and rubber mallet for placing the tiles
gently and easily.
Double charge vitrified tile polished finish of
11.41A.2 Glazed vitrified floor tiles polished finish of size
11.41A.3 Glazed Vitrified tiles Matt/Antiskid finish of size
TINSUKIA DIVISION-ENGINEERING/N F RLY
12.0 ROOFING
12.24S CEILING
Providing 10 mm thick plaster of Paris (gypsum
anhydrous) ceiling up to a height of 5 m above
floor level, over first class kail wood strips 25x6
mm with 10 mm gap in between and reinforced
with rabbit wire mesh fixed to wooden frame
(frame work to be paid separately):
Providing, fixing and embedding sand cast iron
accessories for rain water pipes in the masonry
12.40 surrounded with 12 mm thick cement mortar of
the same mix, as that of masonry (lead
caulking will be paid for separately):
Providing and fixing on wall face unplasticised
Rigid PVC rain water pipes conforming to IS :
12.41 13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap for
thermal expansion, (i) Single socketed pipes.
Providing and fixing on wall face unplasticised -
PVC moulded fittings/ accessories for
unplasticised Rigid PVC rain water pipes
conforming to IS : 13592 Type A, including
jointing with seal ring conforming to IS : 5382,
leaving 10 mm gap for thermal expansion.
12.42.5 Bend 87.5 degrees
12.42.6 Shoe (Plain)
Providing and fixing unplasticised -PVC pipe
clips of approved design to unplasticised - PVC
rain water pipes by means of 50x50x50 mm
hard wood plugs, screwed with M.S. screws of
required length, including cutting brick work
and fixing in cement mortar 1:4 (1 cement : 4
coarse sand) and making good the wall etc.
12.50 Providing and fixing precoated galvanised iron Sqm 150 671.55 100732.5
profile sheets (size, shape and pitch of
corrugation as approved by Engineer-in-charge)
0.50 mm (+ 0.05 %) total coated thickness with
zinc coating 120 grams per sqm as per IS: 277,
in 240 mpa steel grade, 5-7 microns epoxy
primer on both side of the sheet and polyester
top coat 15-18 microns. Sheet should have
protective guard film of 25 microns minimum to
avoid scratches during transportation and
should be supplied in single length upto 12
metre or as desired by Engineer-in-charge. The
sheet shall be fixed using self drilling /self
tapping screws of size (5.5x 55 mm) with EPDM
seal, complete upto any pitch in horizontal/
vertical or curved surfaces, excluding the cost
of purlins, rafters and trusses and including
cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel
sheet roofing accessories 0.50 mm (+0.05 %)
total coated thickness, Zinc coating 120 grams
per sqm as per IS: 277, in 240 mpa steel grade,
5-7 microns epoxy primer on both side of the
sheet and polyester top coat 15-18 microns
using self drilling/ self tapping screws complete
TINSUKIA DIVISION-ENGINEERING/N F RLY
13.0 FINISHING
13.1S CEMENT PLASTER (IN FINE SAND)
13.1 12 mm cement plaster of mix :
15 mm cement plaster on the rough side of
single or half brick wall of mix :
CEMENT PLASTER WITH A FLOATING COAT OF
12 mm cement plaster finished with a floating
coat of neat cement of mix :
Cement plaster 1:3 (1 cement: 3 coarse sand)
finished with a floating coat of neat cement.
13.16S 6MM CEMENT PLASTER
13.16 6 mm cement plaster of mix :
13.25 Extra for plastering:
13.26 Providing and applying plaster of paris putty of Sqm 2510 214.3 537893
2 mm thickness over plastered surface to
prepare the surface even and smooth
Distempering with 1st quality acrylic distemper
(ready mixed) having VOC content less than 50
13.42 gms/litre, of approved manufacturer, of
required shade and colour complete, as per
manufacturer's specification.
13.44S EXTERIOR FINISHING
Finishing walls with Acrylic Smooth exterior
paint of required shade :
13.46.1 New work (Two or more coat applied @ 1.67 Sqm 1100 166.85 183535
68 ltr/10 sqm over and including priming coat of
exterior primer applied @ 2.20 kg/10 sqm)
Finishing with Deluxe Multi surface paint
13.48 system for interiors and exteriors using Primer
as per manufacturers specifications :
13.48.1 Two or more coats applied on walls @ 1.25 Sqm 500 158.95 79475
69 ltr/10 sqm over and including one coat of
Special primer applied @ 0.75 ltr /10 sqm
13.48.3 Painting Steel work with Deluxe Multi Surface Sqm 450 140.05 63022.5
Paint to give an even shade. Two or more coat
70 applied @ 0.90 ltr/10 sqm over an under coat of
primer applied @ 0.80 ltr/10 sqm of approved
brand and manufacture
Painting with synthetic enamel paint of
13.61 approved brand and manufacture to give an
16.0 ROAD WORK
16.1S ROADS
Dry brick pitching half brick thick in drains
16.12 including supply of bricks and preparing the
surface complete :
16.12.1 With common burnt clay F.P.S. (non modular) Sqm 340 607.2 206448
bricks of class designation 7.5
17.0 SANITARY INSTALLATIONS
TINSUKIA DIVISION-ENGINEERING/N F RLY
Providing and fixing white vitreous china
pedestal type water closet (European type W.C.
pan) with seat and lid, 10 litre low level white
P.V.C. flushing cistern, including flush pipe, with
manually controlled device (handle lever),
conforming to IS : 7231, with all fittings and
fixtures complete, including cutting and making
good the walls and floors wherever required :
17.2.1 W.C. pan with ISI marked white solid plastic Each 6 5540.55 33243.3
Providing and fixing white vitreous china flat
back or wall corner type lipped front urinal
basin of 430x260x350 mm and 340x410x265
mm sizes respectively with automatic flushing
17.4 cistern with standard flush pipe and C.P. brass
spreaders with brass unions and G.I clamps
complete, including painting of fittings and
brackets, cutting and making good the walls
and floors wherever required :
17.4.1 One urinal basin with 5 litre white P.V.C. Each 6 5268.85 31613.1
automatic flushing cistern
Providing and fixing wash basin with C.I.
brackets, 15 mm C.P. brass pillar taps, 32 mm
17.7 C.P. brass waste of standard pattern, including
painting of fittings and brackets, cutting and
making good the walls wherever require:
17.7.4 White Vitreous China Flat back wash basin size Each 6 1679.6 10077.6
75 550x 400 mm with single 15 mm C.P. brass
17.8 Providing and fixing white vitreous china Each 6 1500.05 9000.3
76 pedestal for wash basin completely recessed at
the back for the reception of pipes and fittings.
Providing and fixing P.V.C. waste pipe for sink
17.28 or wash basin including P.V.C. waste fittings
17.28.1 Semi rigid pipe
Providing and fixing mirror of superior glass (of
approved quality) and of required shape and
17.32 size with plastic moulded frame of approved
make and shade with 6 mm thick hard board
Providing and fixing bend of required degree
17.38 with access door, insertion rubber washer 3
mm thick, bolts and nuts complete.
Providing and fixing PTMT towel rail complete
with brackets fixed to wooden cleats with CP
brass screws with concealed fittings
arrangement of approved quality and colour.
17.73.2 600 mm long towel rail with total length of 645 Each 8 600.35 4802.8
80 mm, width 78 mm and effective height of 88
mm, weighing not less than 190 gms.
18.0 WATER SUPPLY
18.4S PP-R PIPES
Providing and fixing 3 layer PP-R (Poly
propylene Random copolymer) pipes confirming
to IS:15801 UV stabilized & anti - microbial
fusion welded, having thermal stability for hot &
18.6 cold water supply, including all PP - R plain &
brass threaded polypropylene random fittings,
including trenching, refilling & testing of joints
complete as per direction of Engineer-in-
Charge. -External work
TINSUKIA DIVISION-ENGINEERING/N F RLY
18.7S C.P.V.C. PIPES
Providing and fixing Chlorinated Polyvinyl
Chloride (CPVC) pipes, having thermal stability
for hot & cold water supply, including all CPVC
plain & brass threaded fittings, including fixing
18.7 the pipe with clamps at 1.00 m spacing. This
includes jointing of pipes & fittings with one
step CPVC solvent cement and testing of joints
complete as per direction of Engineer in
Charge.-Internal work - Exposed on wall
Providing and fixing Chlorinated Polyvinyl
Chloride (CPVC) pipes, having thermal stability
for hot & cold water supply, including all CPVC
plain & brass threaded fittings, i/c fixing the
pipe with clamps at 1.00 m spacing. This
includes jointing of pipes & fittings with one
step CPVC solvent cement and the cost of
cutting chases and making good the same
including testing of joints complete as per
direction of Engineer in Charge, Concealed
work, including cutting chases and making
good the wall etc.
Providing and fixing Chlorinated Polyvinyl
Chloride (CPVC) pipes, having thermal stability
for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes
jointing of pipes & fittings with one step CPVC
solvent cement, trenching, refilling & testing of
joints complete as per direction of Engineer in
Charge.-External work
18.15S BRASS FITTINGS
Providing and fixing brass bib cock of approved
Providing and fixing brass stop cock of
approved quality :
Providing and fixing ball valve (brass) of
18.18 approved quality, High or low pressure, with
plastic floats complete :
C.I. SLUICE VALVES/ FIRE HYDRANTS &
18.48 Providing and placing on terrace (at all floor Litre 2000 9.7 19400
levels) polyethylene water storage tank, IS :
12701 marked, with cover and suitable locking
arrangement and making necessary holes for
inlet, outlet and overflow pipes but without
fittings and the base support for tank.
18.49S C.P. BRASS FITTINGS
Providing and fixing C.P. brass angle valve for
18.53 basin mixer and geyser points of approved
quality conforming to IS:8931
TINSUKIA DIVISION-ENGINEERING/N F RLY
18.59S AIR VALVE & WATER METER (BULK TYPE)
18.65 Providing and fixing PTMT soap Dish Holder Each 6 96.75 580.5
having length of 138mm, breadth 102mm,
height of 75mm with concealed fitting
arrangements, weighing not less than 106 gms.
21.0 ALUMINIUM WORK
Providing and fixing aluminium work for doors,
windows, ventilators and partitions with
extruded built up standard tubular sections/
appropriate Z sections and other sections of
approved make conforming to IS: 733 and IS:
1285, fixing with dash fasteners of required dia
and size, including necessary filling up the gaps
at junctions, i.e. at top, bottom and sides with
21.1 required EPDM rubber/ neoprene gasket etc.
Aluminium sections shall be smooth, rust free,
straight, mitred and jointed mechanically
wherever required including cleat angle,
Aluminium snap beading for glazing / paneling,
C.P. brass / stainless steel screws, all complete
as per architectural drawings and the directions
of Engineer-in-charge. (Glazing, paneling and
dash fasteners to be paid for separately) :
21.1.1 For fixed portion
21.1.1.1 Anodised aluminium (anodised transparent or Kg 200 433.95 86790
98 dyed to required shade according to IS: 1868,
Minimum anodic coating of grade AC 15)
21.1.1.2 Powder coated aluminium (minimum thickness Kg 175 466.3 81602.5
of powder coating 50 micron)
For shutters of doors, windows & ventilators
including providing and fixing hinges/ pivots
and making provision for fixing of fittings
wherever required including the cost of EPDM
rubber / neoprene gasket required (Fittings
shall be paid for separately)
21.1.2.1 Anodised aluminium (anodised transparent or Kg 130 531.8 69134
100 dyed to required shade according to IS: 1868,
Minimum anodic coating of grade AC 15)
21.1.2.2 Powder coated aluminium (minimum thickness Kg 175 564.8 98840
of powder coating 50 micron)
Providing and fixing glazing in aluminium door,
window, ventilator shutters and partitions etc.
with EPDM rubber / neoprene gasket etc.
21.3 complete as per the architectural drawings and
the directions of engineer-in-charge . (Cost of
aluminium snap beading shall be paid in basic
21.3.1 With float glass panes of 4.0 mm thickness Sqm 50 1019.8 50990
(weight not less than 10kg/sqm)
21.3.2 With float glass panes of 5 mm thickness Sqm 30 1325.55 39766.5
(weight not less than 12.50 kg/sqm)
26.0 NEW TECHNOLOGIES AND MATERIALS
26.73S PREFAB/PRECAST TECHNOLOGY
TINSUKIA DIVISION-ENGINEERING/N F RLY
Providing and fixing factory made single
extruded WPC (Wood Polymer Composite) solid
door/window/clerestory windows & desertory
other Frames/Chowkhat comprising of virgin
PVC polymer of K value 58-60 (Suspension
Grade), calcium carbonate and natural fibers
(wood powder/ rice husk/wheat husk) and non
toxic additives (maximum toxicity index of 12
for 100 gms) fabricated with miter joints after
applying PVC solvent cement and screwed with
full body threaded star headed SS screws
having minimum frame density of 750 kg/cum,
screw withdrawal strength of 2200 N (Face) &
1100 N (Edge), minimum compressive strength
26.86 of 58 N/mm2, modulus of elasticity 900 N/mm2
and resistance to spread of flame of Class A
category with property of being termite/borer
proof, water/moisture proof and fire retardant
and fixed in position with M.S hold fast/lugs/SS
dash fasteners of required dia and length
complete as per direction of Engineer-In-
Charge. (M.S hold fast/lugs or SS dash fasteners
shall be paid for separately). Note: For WPC
solid door/window frames, minus 5mm
tolerance in dimensions i.e depth and width of
profile shall be acceptable. Variation in profile
dimensions on plus side shall be acceptable but
no extra payment on this account shall be
Providing and fixing factory made single
extruded WPC (Wood Polymer Composite) solid
plain flush door shutter of required size
comprising of virgin polymer of K value 58-60
(Suspension Grade), calcium carbonate and
natural fibers (wood powder/ rice husk/wheat
husk) and non toxic additives (maximum
toxicity index of 12 for 100 gms) having
minimum density of 650 kg/cum and screw
withdrawal strength of 1800 N (Face) & 900 N
26.87 (Edge), minimum compressive strength 50
N/mm2, modulus of elasticity 850 N/mm2 and
resistance to spread of flame of Class A
category with property of being termite/borer
proof, water/moisture proof and fire retardant
and fixing with stainless steel butt hinges of
required size with necessary full body threaded
star headed counter sunk S.S screws, all as per
direction of Engineer-In- Charge. (Note:
stainless steel butt hinges and necessary S.S
screws shall be paid separately)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].