Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹22.9 L+₹1.6 L (7.41%)Rejected-Finance SADASHIV PHUGE NAGAR OPP SANDVIK FACTORY RADHIKA RESIDENCY F WING FLAT NO 7 PHUGEWADI PUNE 411 012 | PUNE | MAHARASHTRA | 411012 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹26.2 L+₹4.8 L (22.7%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹26.2 L+₹4.9 L (22.9%)Rejected-Finance OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹26.6 L+₹5.3 L (24.7%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
₹29.7 L
EMD Value
₹59,400
Closing Date
3 Mar 2022, 6:00 pmClosed
Garrison Engineer (CME) Kirkee
Garrison Engineer (CME) Kirkee, Phugewadi, Dapodi, Kendriya vidyalay Gate , beside Unlimited (Mega Mart) Mall, Pune - 411 012
Provn of street lights from substation No. 08 to old bopkhel gate, special repair to substation No. 9 and provision of certain minor works under GE (CME) kirkee at CME Pune
2022_MES_500637_4
8267/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer (CME) Kirkee
Class D b(i)
9 documents required · 9 mandatory
₹500
Yes
Garrison Engineer (CME) Kirkee
₹59,400
Yes
1 Apr 2022
11 Feb 2022
5 Mar 2022
11 Feb 2022
3 Mar 2022
18 Feb 2022
12 Feb 2022 - 17 Feb 2022
Amount
Excavation in trenches n. exc. 1.5m wide and n exc. 1.5m in depth for laying cables in soft/loose soil and making good disturbed surfaces all as specified and directed.
Excavation in trenches n. exc. 1.5m wide and n exc. 1.5m in depth for pole foundation/laying cables in hard/dense soil and making good disturbed surfaces all as specified and directed.
Excavation in trenches exceeding 1.5m wide and n exc. 3 m in depth for pole foundation/laying cables in hard/dense soil and making good disturbed surfaces all as specified and directed.
M & L for bituminous road/hard standing cutting to a width of 45 cm and depth 50 cm for laying UG cables and making good with cement concrete 1:3:6 type C 1 (using 20 mm graded stone aggregate) complete all as specified and directed.
Returning filling in, including, spreading, levelling, watering and well ramming in layers n exc. 25 cm in soil all as specified and directed..
Removing surplus excavated material to a distance n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point all as specified and directed.
Supply , laying and testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured , electric power cables ( heavy duty) with stranded aluminium conductor 1100 volts grade cross sectional area 4 core 25 Sqmm all as specified and directed.
All as per item No. 07 above, but size 3.5 core 35 Sqmm
All as per item No. 07 above, but size 3.5 core 25 Sqmm
Supply & Laying of DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polythylene with smoooth internal and profiled external surface for non pressure under ground cable incl couplers & bends complete all as specified and directed.
All as per item No.10 above, but outer dia of 77mm and inner dia 63mm
S&F LED street light fittings of 90 watt system wattage and high preesure die cast aluminium housing, IP 66 protection suitable for pole mounting , cool white 6500 K, 240 Volts AC, 50 Hz, operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -20ºC to 60ºC,built in surge protection more incl make proper connection complete including cutting , welding, drilling holes, nut bolts, washer complete all as directed by Engineer-in-charge. ENDURAPEARLPLUSSL90WLED757SASYTOPC Havells or equivalent Surya/philips/C &S.
Supply and fixing or passing through pipe, 1100 volts grade heavy duty, PVC insulated round 3 core 2.5 sqmm copper cable including electrical connection complete all as specified and directed by Engr-in-Charge. Make:- Havells/finolux/Plaza Note:
S&F street light bracket made out of GI pipe medium grade 32 mm bore approx length not less than 120 cm bent to shape including new clamps made of MS flat of size 40x5 mm thick including cutting ,welding ,drilling holes ,nut,bolts washers etc including two coat of aluminium paint over one coat of red oxide primer on MS work complete all as specified and directed.
S&F Kiosk box made out of fibre material complete with TPN ,aluminium bus and suitable for one number MCB (SP) including one No MCB (SP) 6 Amps 240 volts with glands for incoming & out going cable including fixing of flat iron clamps of size 20x4mm on PCC/Steel tubular pole complete all as specified and as directed by Engr-in-Charge. Make: Havells/Sintex.
M&L for steel swaged poles 9 mtr long complete with cast iron base plate, finial taperplug, bolts, nuts and screws as specified type 410 SP-31 and including painting with two coats of aluminum paint over a coat of primer including preparation of new surfaces all as specified and directed.
M&L for providing plain cement concrete type D-2 , 1:4:8 (using 40mm graded stone aggregate) in foundation filling and mass concrete all as specified and directed.
M&L for providing plain cement concrete type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in coping, finished even and fair, including necessary form work all as specified and directed.
S & F of Automatic street light control with infrared sensor based NATURE SWITCH and VOLTAGE MONITORING SYSTEM (VMS) Three phase load of 8 KW for automation of street lights. Nature Switch operation should be based on Natural light Lux level. Required illuminance level for switching ON is < 30 Lux and for switching OFF > 10 Lux. The sensor should also have part night operation facility of min. 4 hrs. to max. 12 hrs. VMS should have adjustable over & under Voltage trip level and protection against phase loss, neutral loss & Phase reverse incl Power contactors (3 nos of capacity 25 amps per phase each) and incoming (3 nos of capacity 32 amps each)- outgoing MCB(3 nos of capacity 32 amps each) & main load circuit wiring (Copper) of minimum 10 sqmm. The sensor , VSM, Power contactor, MCBs incl connected items should be enclosed in a Pole/wall mountable enclosure made of rust proof, electric shock proof,termite proof and FR grade SMC junction box conforming to IP54. The circuit should also have provision for manual operation (i.e. sensor & VMS By-Pass option). Model Swadeep- 02EC8kW3P-VMS or equivqlent in Schneider/Havells/Legrand . Make (i) Nature switch: Kakatiya Energy Systems/Healer/Bajaj (ii) Power contactor- L&T / BCH / Schneider (iii) Voltage Controlling Device- L&T(GIC) or equivalent (iv) MCB-Hager/schneider/L &T /Legrand, (v) Enclosure & circuit sheet- Sintex (shock proof, rust proof,termite proof, FR rade) (v) Circuit wiring-Polycab/Finolex
Note: (i) Nut , bolts, clamp for fixing on Poles/wall are to be included in quoted rates. (ii) The sensor must have the warranty of min of 2 years. (iii) Test certificate and warranty cirtificate must be provided by supplier. (iv) Cost of marking description on the box is incl quoted rates.
M & L for earthing with 600x600x6mm GI earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5m below ground level, connected to and including GI earth lead of 4mm by means of bolts, nuts and check nuts and washers to the extent of 7.5 metres as earthing lead and connecting to the eqpt/machinery etc. incl charchoal dust and common salt packed all around the earth plate in alternate layer in the earth pit all as per electrical plate No.3 of SSR Part I-2009 including chamber made up of PCC 1:2:4 type-B1 with M.S. angle iron frame, C.I. Cover, 20mm dia light grade G.I. pipefrom top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement incl excavation and earth work in any type of soil and testing including taking down old unserviceable earthing complete all as specified and directed. Note : GI lead more than 7.5 mtr will be measured and paid separately.
M & L for point wiring for light/fan/bell with FRLSH cable 1.5 sqmm PVC insulated (red for phase and black for neutral) unsheathed, multi, stranded copper conductor 1100 volt grade in and incl not less than2mm thick PVC casing/caping with all accessories and 1.50 sqmm green in colour PVC copper conductor cable for earth continuity connected to common earth dolly incl PVC box surface/ flush type with PVC sheet for mouting fittings such as switches, sockets, fan regulators, etc. compete all as specified and directed for one light/fan/bell point controlled by one switch & making good to disturbed surface of wall etc.
S & F switch piano, flush type, single pole one way 5 amps complete all as specified and directed.
S & F ceiling rose, PVC/Polycarbonate isolated body, surface bakelite 65mm x 50mm, 3 terminate incl PVC square block complete all as specified and directed.
S & F MCB distribution board double door 240 volts 4 way with 200 Amps rated bus bar and making good to disturbed surface of floors walls.
S & F MCB TPN 63 Amps, 415 Volt, AC incl taking down old unserviceable one complete all as specified and directed.
M & L for sub main wiring with two run of 10 sqmm single core multi stranded PVC insulated and unsheathed copper conductor (red for phase and black for neutral) of grade 1100 volt FRLSH cable in and including 1100 volt electrical grade PVC casing caping of desired colour not less than 1.2 mm thick and 25mm wide & 10 Sqmm copper condutor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth dolly complete all as specified and directed.
All as per item No. 26 above, but size 6 Sqmm two runs and with one run 6.0 sqmm FRLSH copper wire for earth continuity. Make of wire -- Finolex/ Havells/ Polycab/ Plaza
All as per item No. 26 above, but size 4 Sqmm two runs and with one run 4.0 sqmm FRLSH copper wire for earth continuity. Make of wire -- Finolex/ Havells/ Polycab/ Plaza
Supplying and laying GI tubing light grade 40mm dia incl all accessories for encasing cables for mechnical protection, laid under Plinth/ Floors/ Path culverts of fixed on wall or concealed in wall/floor or along poles with complete accessories such as bends/ sockets/reducers/saddles incl necessary threading/ drilling works all as specified and directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor 1100 volts grade in trencehs/passing through pipe/fixing on walls, floors etc incl using suitable clamp of cross sectional area 4 core 16 Sqmm all as specified and directed.
Supply and fixing PVC cable ducts 75mmx45mm with all accessories for fixing of sub main wiring drawn through cable duct along wall complete all as specified and directed.
Supply and dixing energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium light 50 watt with high power LEDs as light source, suitable for highlighting architectural features or area lighting. Also suitable to rough services/installations. (Notes:- The contractor is responsible to arrange suitable height of ladder to fix the fittings) Make :- Havells cat No. LHEECNP7PB6J050 or equivalent of Philips/ Bajaj
M&L for earthing with 600x600x3.15mm copper earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5m below ground level, connected to and including copper Strip of size 20x3 mm by means of bolts,nuts and check nuts and washers to the extent of 7.5 metres as earthing lead and connecting to the eqpt/machinery etc. incl charcoal dust and common salt packed all around the earth plate in alternate layer in the earth all as per electrical plate No. 3 of SSR Part I-2009 including chamber made up of PCC 1:2:4 type B1 with M.S. angle iron frame, C.I. Cover, 20mm dia light grade G.I. Pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement incl excavation and earth work in any type of soil and testing complete including taking down old unserviceable earthing all as specified and directed. Note :- copper Strip more than 7.5 mtr will be measured and paid separately.
M&L for earthing with 600x600x6mm galvanised steel earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5m below ground level, connected to and including G.I. Strip of size 32x6 mm by means of bolts,nuts and check nuts and washers of galvanised steel to the extent of 7.5 metres as earthing lead and connecting to the eqpt/machinery etc. incl charcoal dust and common salt packed all around the earth plate in alternate layer in the earth pit all as per electrical plate No. 3 of SSR Part I-2009 including chamber made up of PCC 1:2:4 type B1 with M.S. angle iron frame, C.I. Cover, 20mm dia light grade G.I. Pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement incl excavation and earth work in any type of soil and testing complete including taking down old unserviceable earthing all as specified and directed. Note :- GI Strip more than 7.5 mtr will be measured and paid separately
M&L earth continuity conductor or main earthing lead of size 32x6mm galvanised iron strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete including taking down old unserviceable earthing continuity conductor all as specified and directed.
S&F earth continuity conductor or main earthing lead of size 20x3 mm copper strip fixed to wall with S&F of porcelin /PVC insulator buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete including taking down old unserviceable earthing continuity conductor all as specified and directed by Engr-in-Charge
M & L earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe of fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia GI or steel wire complete all as specified and directed.
M&L for point wiring for power point with 2.5 sqmm FRLSH PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade in and incl not less than 2mm thick PVC casing/caping with all accessories and 2.5 sqmm green in colour FRLSH PVC copper conductor cable for earth continuity connected to common earth dolly incl PVC box surface/ flush type with PVC sheet for mounting of 15 amp socket outlet flush type on independent board complete all as specified and directed.
S & F switch socket combination 5 in 1, 5 and 15 Amp flush type complete all as specified and directed.
S&F MCB distribution board Double door SPN 240 volts 8 way with 200 amps rated bus bar and making good to disturbed surfaces of floors walls etc incl taking down old unserviceable one.
S&F load line vertical TPN distribution board 6 way including 1 incommer MCCB of 125 Amps 4 pole double door IP-54 protection, powder coated, IK09 with provision of suitable size bus bar and cable management kit complete all as specified and directed. Make : Indoasian cat part No 811889 or eqlnt in Hager/ Havells/ Legrand
S & F MCB SP 6 to 32 Amps, 230 V AC all as specificed and directed.
S & F MCB SPN 40 Amps, 230 V, AC all as specificed and directed.
S & F MCB SPN 63 Amps, 230 V, AC all as specificed and directed.
Supply and fixing water proof plywood ISI Marked, 8mm thick of size not less than 400mm x 400mm incl provisions for mounting on walls or fixed to window, cutting of hole for mounting of PVC exhaust fan including necessary arrangement for modificaion to wooden window panel complete all as specified and directed.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 200/250 mm complete all as specified and directed.
Supply, install, connect, test and commissioning factory made, dust/vermin, weather proof self ventilated, cubical of size 1.5x0.50x1.2 (Appx) with front made of and rear opening, hinged door for front and rear with MS angle iron frame 50x50x5mm for base support, 3.15 mm thick CRCA sheet, LT panel board, (LT KIOSK), CPRI approved out door, cubicle type, floor mounted, double door with neoprene gasket and locking arrangement with canopy including painting with powder coated on steel surfaces internally & externally and provision of two Nos earth terminals on both sides, cable glands and PCC foundation with PCC 1:2:4, type-B1, and 30cm all around the outer dimension of panel including gap for insertion of cable having bottom of panel at height of 45cms above the ground level with cable entry glands to accommodate and including the following accessories:-
Copper bus bar rectangular 300 Amps full for phase and half for neutral mounted on epoxy insulators with colour coding PVC sleeves-01 Job
MCCB 200 Amps, TPN, 415 Volts, 50 Hz, 36 KA - 01 No (incoming)
MCCB 40 Amps, TP, 415 Volts, 50 Hz, 36 KA- 06 Nos. (outgoing)
RYB LED indicator Lamp- Set of three-01 no.
Provision of cubicle to accommodate the above mentioned accessories.
Internal wiring of panel board, metering equipment with suitable of size PVC insulated, unsheathed, 1100 Volt grade cable with multistranded copper conductor, including provision of lugs/thimbles of either ends of cable
M&L for earthing with 600x600x6mm GI earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5m below ground level, connected to and including galvanised iron strip of size 25x4 mm by means of bolts,nuts and check nuts and washers to the extent of 7.5 metres as earthing lead and connecting to the eqpt/machinery etc. incl charcoal dust and common salt packed all around the earth plate in alternate layer in the earth all as per electrical plate No. 3 of SSR Part I-2009 including chamber made up of PCC 1:2:4 type B1 with M.S. angle iron frame, C.I. Cover, 20mm dia light grade G.I. Pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement incl excavation and earth work in any type of soil and testing complete including taking down old unserviceable earthing all as specified and directed. Note :- GI strip more than 7.5 mtr will be measured and paid separately.
Supply & fixing copper bus bar chamber 100 Amp capacity 4 strips not less than 400mm long, outdoor type including one MCCB 63 Amps 4 pole as incommer with locking arrangement including MS angle iron frame 50x50x5mm for base support grouting in PCC 1:3:6 and connection with UG XLPE cable with suitable copper thimbles complete all as specified and directed.
Supply, install, connect, test and commissioning factory made, dust/vermin, weather proof self ventilated, cubical of size 1.5x0.50x1.2 (Approx) with front made of and rear opening, hinged door for front and rear with MS angle iron frame 50x50x5mm for base support, 3.15mm thick CRCA sheet, LT panel board, (LT KIOSK), CPRI approved out door, cubicle type, floor mounted, double door with neoprene gasket and locking arragement with canopy including painting with powder coated on steel surfaces internally & externally and provision of two Nos earth terminals on both sides, cable glands and PCC foundation with PCC 1:2:4, type B-1 and 30cm all around the outer dimension of panel including gap for insertionof cable having bottom of panel at height of 45cms above the ground level with cable entry glands to accommodate and including the following accessories:-
Copper bus bar rectangular 100 Amps full for phase and half for neutral mounted on epoxy insulators with colour coding PVC sleeves-01 Job
MCCB 100 Amps, TPN, 415 Volts, 50 Hz, 36 KA - 01 No. (incoming)
MCCB 40 Amps, TPN, 415 Volts, 50 Hz, 36 KA - 02 Nos. (outgoing)
MCB SPN 32 Amps - 04 Nos (outgoing)
RYB LED indicator Lamp- Set of three-01 no.
Digital timer switch with inbuilt backup current capacity 16 Amps operated on 415 Volts AC 50 Hz complete all as specified and directed. Make :- Indoasian cat part No. TDA43111/Legrand
Supply & fixing in replacement three pole contactor 63 A current rating 70A general use 10A, 415 Volt with coil. Make L & T model MNX 70 three pole contactor complete. Make:- L&T cat part No. CS97076/Legrand/Schneider
Provision of cubicle to accommodate the above mentioned accessories.
Internal wiring of panel board, metering equipment with suitable of size PVC insulated, unsheathed, 1100 Volt grade cable with multistranded copper conductor, including provision of lugs/thimbles of either ends of cable
Supply, installation, commissioning of water cooler fully stainless steel, electric driven single phase having approx storage capacity 150 Ltr and nominal cooling capacity 150 Ltrs/hour make: Bluestar/voltas
S & F GI medium grade tubing of bore 15mm with all fittings and fixed complete to walls/ceiling/ground complete all as specified and directed.
M & L for PVC pipe 40mm dia with all fittings and fixing accessories such as coupler, lock nut, saddle, pipe hook and laid on floor (for wash out line)
M & L for stop valve 15mm cast alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipes all as specified and directed.
Supply & fix GM gate valves 15mm with iron wheel head, screwed both ends for iron pipe all as specified and directed.
S & F PVC connections 15mm size with PTMT nuts of length 600mm long all as specified and directed.
M & L for sub main wiring two run of size 2.5 sqmm PVC insulated electric power cable (heavy duty) 1100 Volts grade, FRLSH with stranded copper conductor with 1.5sqmm PVC insulated FRLSH copper conductor earth wire in PVC casing caping of suitable size (two run of 2.5 sqmm cable and one of 1.5 sqmm wire and one run of PVC casing caping will be measured as one unit) all as specified and directed (from distrubution board to socket point near water cooler)
S & F for single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20 Amp all as specified and directed.
M & L for framework of watercoolers and similar work made out of 45x45x6mm MS equal angle conforming to Fe 290 Gde-E-165 duly welding works including two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (as in resting platform of water cooler)
M/S kirpan Enterprises
Pritam Electro Mechanical Services
M/S. Niksun Electro-Infra Private Limited
Techmat trading solution
metro electrical services
PRATHAMESH ELECTRICAL
AIRDOT ENGINEERING
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .