23 Oct 2021, 4:00 pmClosed
Executive Engineer
Executive Engineer PWD RNB Spl. Sub Division Doda
As per NIT/SBD
2021_PWDJK_143976_1
e-NIT 64 of 2021-22
Open Tender
Civil Works
Item Wise
30 days
Doda
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Yes
Treasury Challan under MH 0059
Exempted
1 Nov 2021
16 Oct 2021
25 Oct 2021
16 Oct 2021
23 Oct 2021
16 Oct 2021
Amount
Demolishing cement concrete manually / by mechanical means including disposal of material within 50 meters lead as per direction of Engineer incharge: 1:4:8 or leaner mix (i/c equivalent design mix) (Incl. carriages complete job)
Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge.
Extra for cutting reinforcement bars manually / by mechanical means in RCC or R.B work (payment shall be made on the cross sectional area of RCC or R.B Work)
Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.B. work
Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar
Removing mortar from bricks and cleaning bricks incl. stacking with a lead of 50 Mtrs (Stacks of cleaned bricks shall be measured) from brick work in cement mortar
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead :
Of area of 3 sqm. and below
Of area beyond 3 sqm
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 meters lead :
Of area of 3 sqm. and below
Of area beyond 3 sqm.
Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 meters lead.
Demolishing mud phaska in terracing and disposal of material within 50 meters lead
Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead.
Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 meters lead With cement mortar 1:4 (1 cement : 4 fine sand) (including all leads, lifts and carriages)
Renewing glass panes, with putty and nails wherever necessary including raking out old putty : :
Float glass panes of thickness 4.0 mm(weight not less than 10kg/sqm)
Float glass panes of thickness 5.0 mm(weight not less than 12.5 kg/sqm).
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: (including all leads, lifts and carriages)
1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) (including all leads, lifts and carriages)
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level (including all leads, lifts and carriages)
Extra for brick work/tile brick/AAC block masonry in superstructure above floor V level for each four floors or part thereof by mechanical means:
Half brick masonry with common burnt clay (non modular) bricks of class designation 7.5 in foundations and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand) (including all leads, lifts and carriages)
Extra for half Brick masonry in superstructure above plinth level upto floor V level.
Centering and shuttering including strutting, propping etc. and removal of form for: (including all leads, lifts and carriages)
Suspended floors, roofs, landings, balconies and access platforms
Edges of slabs and breaks in floors and walls Under 20 cm wide
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) (including all leads, lifts and carriages)
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) (including all leads, lifts and carriages)
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 5.3.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) (including all leads, lifts and carriages)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Cold twisted bars (including all leads, lifts and carriages)
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. (including all leads, lifts and carriages)
Providing and fixing M.S tubular frames for doors, windows, ventilators and cupboard with rectangular /L-type sections, made of 1.60 mm thick M.S Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of C.C. 1:3:6 (1cement : 3 coarse sand :6 graded stone aggregate 20mm nominal size) . (including all leads, lifts and carriages)
Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded (including all leads, lifts and carriages)
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes. (including all leads, lifts and carriages)
Regrading terracing of mud phaska covered with tiles or bricks, in cement by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud phaska to proper slope, relaying mud plaster gobri leaping and tiles or bricks, grouted in cement mortar 1:3 (1 cement: 3 fine sand), including replacing unserviceable tiles or bricks with new ones and disposal of unserviceable material to the dumping ground (the cost of the new tiles or brick excluded) within 50 meters lead. (including all leads, lifts and carriages)
Raking out joints in lime or cement mortar and preparing the surface for re-pointing or re plastering, including disposal of rubbish to the dumping ground within 50 meters lead.
White washing with lime to give an even shade :
Old work (two or more coats)
Old work (one or more coats)
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Distempering with 1st quality Acrylic/oil bound washable distemper (ready-made) having VOC content less than 50 grams/litre of approved manufacturer and of required shade and colour complete as per manufacturers’ specifications, one or more coats on old work
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade, one or more coats on old work.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats on old work.
15mm Cement plaster on the rough side of single or half brick wall of mix: (including all leads, lifts and carriages)
1 : 4 ( 1 cement : 4 fine sand)
1 : 6 ( 1 cement : 6 fine sand)
12mm Cement plaster of mix:
1 : 4 ( 1 cement : 4 coarse sand)
1 : 6 ( 1 cement : 6 coarse sand)
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.
Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm)
Finishing walls with water proofing cement paint of required shade: Old work (one or more coats applied @ 2.20 kg/10sqm) over priming coat of primer applied @ 0.80 liters/10sqm complete including cost of priming coat.
Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work
Painting on G.S sheets with synthetic enamel paint of approved band and manufacture of required colour to give an even shade on New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution.
Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
1 mm thick
2 mm thick
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven storey height made with 40 mm dia M.S. tube 1.5 m centre to centre horizontal and vertical tubes joining with cup and lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffoldings for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.: Internal work (Parkash, Suyra Make) or equivalent (exposed on wall)
15 mm dia. nominal bore (Medium)
20 mm dia. nominal bore (Medium)
25 mm dia. nominal bore (Medium)
32 mm dia. nominal bore (Medium)
Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work) (Parkash, Suyra Make) or equivalent
15 mm dia. nominal bore (Medium)
20 mm dia. nominal bore (Medium)
25 mm dia. nominal bore (Medium)
32 mm dia. nominal bore (Medium)
40 mm dia. nominal bore (Medium)
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work) (Uniqu/DRP make)
15 mm nominal bore
20 mm nominal bore
25 mm nominal bore
32 mm nominal bore
40 mm nominal bore
Providing & fixing water closet squrating pan (Indian type W.c pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.C.V flushing cistern, including flush pipe (of approved make) with manually controlled device (handle ever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required..
White vitreous china Orissa pattern W.C pan of size 580 x 440 mm with integral type foot rests.
Providing and fixing white vitrous china pedestal type water closet (European type W.C Pan) with seat and lid, 10 litre low level white P.V.C flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
W.C Pan with ISI marked white solid plastic seat and lid.
W.C Pan with ISI marked black solid plastic seat and lid.
Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required :
White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar taps
White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap.
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265mm sizes respectively.
Providing and fixing P.V.C low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete: 10 liter capacity -White
Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete: White solid plastic seat with lid
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-Charge and finished smooth. White Agaria Marble Stone (18mm) (including all leads, lifts and carriages)
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
610x460mm bowl depth 200mm
470x420mm bowl depth 178mm
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete:
Semi rigid pipe 32 mm dia
Flexible pipe 32 mm dia
Providing and fixing PTMT pillar cock of approved quality and colour.
15 mm nominal bore, 107 mm long, weighing not less than 110 gms.
15 mm nominal bore 125 mm long foam flow, weighing not less than 120 gms.
Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931
Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.
Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : (including all leads, lifts and carriages)
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth for manholes Size 90x80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry chamber for underground C.I. inspection chamber and bend with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg ) R.C.C. top slab with 1:1 ½ : 3 mix ( 1 cement : 1 ½ coarse sand : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : (including all leads, lifts and carriages)
Inside dimensions 455x610 mm and 45 cm deep for single pipe line-
Inside dimensions 500x700 mm and 45 cm deep for single pipe line with one or two inlets
Inside dimensions 600x850 mm and 45 cm deep for single pipe line with three or more inlets.
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections 1.63 mm (14 G) thick shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.)
For fixed portion. Anodized aluminum (Anodized transparent or dyed to required shade according to IS:1868, minimum anodic coating of grade AC 15)
Powder coated aluminum (minimum thickness of powder coated 50 microns)
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections 1.63 mm (14 G) thick shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.)
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.) Anodized aluminum (Anodized transparent or dyed to required shade according to IS:1868, minimum anodic coating of grade AC 15)
Powder coated aluminum (minimum thickness of powder coated 50 microns)
Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board (conforming to IS: 12823 Grade-I type-II) in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-incharge.
Pre-laminated particle board with decorative lamination on both sides.
Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board (conforming to IS: 12823 Grade-I type-II) in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-incharge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side.
Repair to aluminium door shutters incl. refixing / fixtures / ACP sheets rubber gasket / aluminium beeding etc complete (Cost of ACP sheet paid separtely)
Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in- charge. (Cost of aluminum snap beading shall be paid in basic item.) With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm)
Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg for doors including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in- plate etc. complete as per the direction of Engineer-in-charge. With Stainless Steel cover plate minimum 1.25 mm thickness
Providing and fixing Brass 100mm mortice latch and lock with 6levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :
Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6mm, with 40mm dia, steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately).
Second class Kail wood (30mm thick)
Second class Kail wood (35mm thick)
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.
Particle Board 12mm thick. Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS : 3087 marked
Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side, Grade I, Type II IS : 12823 marked
Pre-laminated particle board with decorative lamination on both sides, Grade I, Type II IS : 12823 marked
Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : Second class Kail wood (35mm thick)
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete:
2nd class Kail wood 50 x 12 mm
Providing and fixing wooden moulded corner beading of size 50x50 mm (base and height) of triangular shape to the junction of paneling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete. Second class kail wood
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm widex1.6mm thick with flanges of 27mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm diax40mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.5mm of required length with nuts & bolts of required size and other end of angle hanger fixed with G.I. channels 45x15x0.9 mm running at the spacing of 1200 centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having clips of 10.5 mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diaX230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre to centre, with 25mm long drive-all screws @ 230 mm interval ,including fixing of gypsum board/calcium silicate board to ceiling section and perimetre channel with the help of dry wall screws of size 3.5x25mm at 230mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the gypsum board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers’ specification and also including the cost of making openings for light fittings, grills diffusers, cutouts made with frame of perimetre channels suitably fixed all complete as per drawing and specification and direction of the Engineer-in-Charge but excluding the cost of painting with:
8 mm thick Calcium Silicate Board made with Calcareous and Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process.
Providing and fixing tiled False Ceiling of specified materials of size 595x595mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms/sqm both side inclusive ) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200 x 600mm and secondary cross “T” of length 600mm and size 24x25 mm made of 0.30mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.30mm and laying false ceiling tiles of approved texture in the grid including, wherever, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27x37x25x1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanized butterfly level clips of size 85x30x0.8 mm spaced at 1200mm center to center along size 85x30x0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard manufactured from natural gypsum as per IS 2095 part-I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.
Providing and laying water proofing treatment on Roofs of slabs by applying Chryso TAPELASTIC - consisting of following operations: - a) Cleaning of RCC to remove dust and loosely adhering particles completely. Fill the Pinholes, visible cracks and gaps of pipe with polymer repair mortar 1:2:4 cement - sand mortar, mixed with CHRYSO ARMOURCRETE. Application of 1:2:4 cement - sand mortar, mixed with CHRYSO ARMOURCRETE - as a coving at the corners of floor and the vertical surface in the sunken area, and between floor and walls in the remaining area. After surface preparation, first layer of CHRYSO TAPELASTIC - Two component Elastomeric high performance cementitious waterproof coating @ 0.750 gram per /sqm.. b) Laying and sandwich layer of Fibre glass cloth when the first coating is still green. c) Second layer of 1.5 mm thickness Chryso TAPELASTIC - Two component Elastomeric high perfornamce cementitious waterproof coating @ 0.750 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall. d). Providing and laying screed concrete (1:2:4) of 50 mm thickness admixed with Chryso STRUCO EXCEL - Intergal waterproofing compound over the CHRYSO TAPELASTIC applied surface on roof, so as to achieve a minimum slope of 1:100 for proper run off of rain water. Minimum thickness near the rain water pipes should be 25 mm. Proper care to be taken while placing screed concrete so as to ensure that the waterproofing membrance is not ruptured.
Providing and Laying water proofing treatment in Sunken Portion of WC, bathroom etc by applying CHRYSO TAPELASTIC consisting of following operations : - a) Surface preparation Cleaning of RCC to remove dust and loosely adhering particles completely. b) Fill the Pinholes, visible cracks and gaps of pipe with polymer repair mortar 1:2:4 cement - sand mortar, mixed with CHRYSO ARMOURCRETE. c) Application of 1:2:4 cement - sand mortar, mixed with CHRYSO ARMOURCRETE -as a coving at the corners of floor and the vertical surface in the sunken area, and between floor and walls in the remaining area. Application of first coat fo CHRYSO TAPELASTIC - Two component Elastomeric high performance Cementitious Waterproof coating CHRYSO TAPELASTIC - It comes with 2 pack system A pack is polymer and pack B is cement filler to be mixed as per tiechnical data sheet. Waterproof coating onto the prepared surface form continuous film on the floor of the sunken area. Apply second coat of Chryso TAPELASTIC - Two component Elastomeric high performance cementitious Waterproof coating after 5 to 6 hours to first coat take the coating over the vertical surfaces on to the floor and over the coving on to the wall (before tiling) to at least 300 mm above the final finished floor level. The coating shall also be continued on to the inner surfaces of the pipe penetration holes. Two coats shall be applied @ 1.5 kg per/sqm in two coats. d). Curing after application of CHRYSO TAPELASTIC - Two component Elastomeric high performance cementitious waterproof coating initial air drying shall be done for 3-6 hours. During this period, no water should be used orcuring. After a maximum period of 6-8 hours after the final application, moist curing shall be done for the next 2-3 days, either by spraying water or by using wet burlap. During this period, the CHYRSO TAPELASTIC coating at no point of time should be left completely dry or submerged in water. After the moist curing the Chryso TAPELASTIC - Two component Elastomeric high performance cementitious waterproof coating shall be allowed to air dry for 3 days before submersion in water. e). Providing a 12 mm thick cement-sand plaster (1:4) on the water proofing coating by mixing an integral waterproffing compound, CHRYSO STRUCO EXCEL @ 200 GM per bag of cement.
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete.
40mm thick with 20 mm nominal size stone aggregate
50 mm thick with 20mm nominal size stone aggregate
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete. (including all leads, lifts and carriages)
Size of tile 600x600 mm
Providing and fixing Anti-skid premium tiles on floor (thickness to be specified by the manufacturers) of Ist quality of RAK, KAJARIA make in any colour laid on 20mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) incl. pointing the joints with white cement and matching pigment etc complete
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete (including all leads, lifts and carriages)
Size of tile 600x600 mm
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. (including all leads, lifts and carriages)
In colour such as White, Ivory, Grey, Fume Red Brown
In all colours, shades, except White, Ivory, Fume Red Brown
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, laid on 20 mm thick cement mortar 1:4 (1Cement : 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete. (including all leads, lifts and carriages)
In colour such as White, Ivory, Grey, Fume Red Brown
In all colours, shades, except White, Ivory, Fume Red
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (including all leads, lifts and carriages)
Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average) thick cement mortar 1:3 (1 cement:3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing, polishing and curing complete
Disposal of unserviceable dismentled material / waste mulba by mechanical transportation outside Municipal limits incl. cost of loading, unloading, stacking complete (Trolly)
Grinding and polishing old terrazo flooring / skirting with floor polish of specified brand for smooth finishing incl. disposal of waste material of griding / polishing from site of work to dumping site at ground floor
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. (including all leads, lifts and carriages)
Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. (Grantine work)
Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured)
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete.
Fixed to steel windows by welding
Fixed to openings / wooden frames with rawl plugs screws etc
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete
15mm nominal bore
20mm nominal bore
Providing and fixing plain, square edged wooden beading 65x12 mm section with screws of approved quality for ceiling 1st class kail wood.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Kail wood
Dismantling aluminum / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material within 50 meters lead as directed by Engineer-in-charge.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc.
15mm nominal outer dia pipes
20mm nominal outer dia pipes
25mm nominal outer dia pipes
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)
25 mm nominal bore
32 mm nominal bore
40 mm nominal bore
50 mm nominal bore
Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal / vertical or curved surface) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required
0.50 mm thick with zinc coating not less than 275 gram/m2
Extra for straight cutting in C.G.S. sheet roofing for making opening of area exceeding 40sq.decimetre for chimney stacks, sky light etc
0.50 mm thick
Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
Ridges plain (500 - 600mm)
Barge board (Upto 300 mm)
Supply of Labour (Mazdoor) for various day to day works as per directions of engineer in charge
Supply of Labour (Mason) for various day to day works as per directions of engineer in charge
Supply of CARPANTER for various day to day works as per directions of engineer in charge
Supply of PLUMBER for various day to day works as per directions of engineer in charge
Supply of Welder for various day to day works as per directions of engineer in charge.
Providing and fixing 18 mm thick, 150 mm wide pelmet of coir veneer board ISI marked IS: 14842-2000, including top cover of 6mm coir veneer board, nickel plated M.S. pipe 20 mm dia (heavy type) curtain rod with nickel plated brackets including fixing with 25x3 mm M.S. flat 10 cm long fixed to pelmet with hollock wood cleats of size 100mm x 40mmx40 mm on both inner side of pelmet and rawl plugs 75mm long etc. all complete.
Providing and fixing aluminum extruded section body tubular type universal hydraulic door closer,(having brand logo with IS: 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete :
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength confirming to IS:4454 part-1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover.
Providing and fixing ball bearing for rolling shutters.
Finishing walls with Acrylic smooth exterior paint of required shade:
Old work (two or more coats applied @ 1.67 liters/10sqm on existing cement paint surface)
Old work (one or more coats applied @ 0.90 liters/ 10sqm)
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: 1 meter from cutting edge (including all leads, lifts and carriages)
All kinds of soil :
Ordinary Rock
Hard Rock (Blasting prohibited )
Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: (including all leads, lifts and carriages)
All kinds of soil :
Ordinary Rock
Hard Rock (Blasting prohibited )
Providing and fixing of Curtains in different sizes of approved make including necessary fittings and approved by the engineer-in-charge complete Job.
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorophriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL antitermite treatment. (excluding the cost of chemical emulsion): Along external wall where the apron is not provided using chemical emulsion (Chlorophriphos/ Lindane E.C. 20% with 1% concentration) @ 7.5 litres/sqm of the vertical surface of the sub-structure to a depth of 300 mm including excavation of channel along the wall & rodding etc. complete:
Providing and fixing PVC pipe of different dia including all necessary fittings complete job.
100 mm dia
150 mm dia
200 mm dia
Providing and fixing window blinds including all fixture and accessories, complete Job.
MANZOOR AHMED NATNOO
Shabir Ahmed
Khalid Gani Zargar
TAHZEEMA BEUM
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .