Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹32.7 L+₹28,177.50 (0.87%)Rejected-AOC 101 1ST FLOOR JASOL RESIDENCY 14TH CROSS KANAKANAGAR R T NAGAR POST BANGALORE 560032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹32.9 L+₹50,130.50 (1.54%)Rejected-AOC NO 439 AHIV ADAN 11ND FLOOR 2RD STAGE INDIRA NAGAR BANGALORE 560 075 | BENGALURU URBAN | KARNATAKA | 560075 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹35.6 L+₹3.2 L (9.82%)Rejected-AOC NO 12 5TH B CROSS SHARADAMBA NAGAR M E S ROAD BANGALORE 560013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹35.9 L+₹3.4 L (10.5%)Rejected-AOC NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
4 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
BANGALORE
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
REPAIRS MAINTENANCE OF EXTERNAL ELECTRICATION SYSTEM OH LINES CABLES LT SWITCH GEARS SECURITY LIGHTS AND OTHER CONNECTED ITEMS AT DGQA OFFFICE COMPLEX UNDER GE NORTH BANGALORE
2020_MES_404359_1
8494
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
BANGALORE
Class D category b(i)
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹80,000
Yes
11 Jan 2021
17 Dec 2020
6 Jan 2021
17 Dec 2020
4 Jan 2021
30 Dec 2020
17 Dec 2020 - 29 Dec 2020
60 days
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in deep for laying of cables / errection of pole etc complete and getting in hard/dense soil complete all as specified and as directed.
Excavation in trenches in hard/dense soil not less than 1.5 mtr deep and not exc 3 mtr in deep for pole foundation etc complete all as specified and as directed.
Returning, filling in excavated soil, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in hard / dense soil etc complete all as specified as directed.
Removing the excavated material to a distance exc. 50m but n. exc. 100m and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified as directed.
Sand cushioning in layers for cables in trenches / ducts for cable including consolidation complete all as specified and directed. NOTE: Punned thickness will be measured for payment purpose.
Bricks, sub class 'B' of old size 230 mm x 115 mm x 75 mm laid in trenches for cable protection all as specified and directed.
XLPE insulated, galvanised steel strip or wire armoured and PVC bedded, heavy duty, LT cable 10 sq.mm, 2 core, 1100 volts grade with multi stranded aluminium conductor, including cable glands, cable lugs etc., to suit the cable size, laid in trenches, or fixed along with the poles, bare or through GI pipe, laid under floors / road etc., fixed / concealed in walls / encased in GI pipe etc including taking out old unserviceable cable, jointing and testing complete all as specified and as directed.
XLPE insulated, galvanised steel strip or wire armoured and PVC bedded, heavy duty, LT cable 10 sq.mm, 4 core, 1100 volts grade with multi stranded aluminium conductor, including cable glands, cable lugs etc., to suit the cable size, laid in trenches, or fixed along with the poles, bare or through GI pipe, laid under floors / road etc., fixed / concealed in walls / encased in GI pipe etc including taking out old unserviceable cable, jointing and testing complete all as specified and as directed.
XLPE insulated, galvanised steel strip or wire armoured and PVC bedded, heavy duty, LT cable 16 sq.mm, 4 core, 1100 volts grade with multi stranded aluminium conductor, including cable glands, cable lugs etc., to suit the cable size, laid in trenches, or fixed along with the poles, bare or through GI pipe, laid under floors / road etc., fixed / concealed in walls / encased in GI pipe etc including taking out old unserviceable cable, jointing and testing complete all as specified and as directed.
XLPE insulated, galvanised steel strip or wire armoured and PVC bedded, heavy duty, LT cable 35 sq.mm, 3.5 core, 1100 volts grade with multi stranded aluminium conductor, including cable glands, cable lugs etc., to suit the cable size, laid in trenches, or fixed along with the poles, bare or through GI pipe, laid under floors / road etc., fixed / concealed in walls / encased in GI pipe etc including taking out old unserviceable cable, jointing and testing complete all as specified and as directed.
XLPE insulated, galvanised steel strip or wire armoured and PVC bedded, heavy duty, LT cable 50 sq.mm, 3.5 core, 1100 volts grade with multi stranded aluminium conductor, including cable glands, cable lugs etc., to suit the cable size, laid in trenches, or fixed along with the poles, bare or through GI pipe, laid under floors / road etc., fixed / concealed in walls / encased in GI pipe etc including taking out old unserviceable cable, jointing and testing complete all as specified and as directed.
XLPE insulated, galvanised steel strip or wire armoured and PVC bedded, heavy duty, LT cable 95 sq.mm, 3.5 core, 1100 volts grade with multi stranded aluminium conductor, including cable glands, cable lugs etc., to suit the cable size, laid in trenches, or fixed along with the poles, bare or through GI pipe, laid under floors / road etc., fixed / concealed in walls / encased in GI pipe etc including taking out old unserviceable cable, jointing and testing complete all as specified and as directed.
XLPE insulated, galvanised steel strip or wire armoured and PVC bedded, heavy duty, LT cable 120 sq.mm, 3.5 core, 1100 volts grade with multi stranded aluminium conductor, including cable glands, cable lugs etc., to suit the cable size, laid in trenches, or fixed along with the poles, bare or through GI pipe, laid under floors / road etc., fixed / concealed in walls / encased in GI pipe etc including taking out old unserviceable cable, jointing and testing complete all as specified and as directed.
XLPE insulated, galvanised steel strip or wire armoured and PVC bedded, heavy duty, LT cable 150 sq.mm, 3.5 core, 1100 volts grade with multi stranded aluminium conductor, including cable glands, cable lugs etc., to suit the cable size, laid in trenches, or fixed along with the poles, bare or through GI pipe, laid under floors / road etc., fixed / concealed in walls / encased in GI pipe etc including taking out old unserviceable cable, jointing and testing complete all as specified and as directed.
XLPE insulated, galvanised steel strip or wire armoured and PVC bedded, heavy duty, LT cable 185 sq.mm, 3.5 core, 1100 volts grade with multi stranded aluminium conductor, including cable glands, cable lugs etc., to suit the cable size, laid in trenches, or fixed along with the poles, bare or through GI pipe, laid under floors / road etc., fixed / concealed in walls / encased in GI pipe etc including taking out old unserviceable cable, jointing and testing complete all as specified and as directed.
Galvinised iron tubing, light grade, 25mm bore with all accessories for cable protection fixed on poles/buildings or laid in trenches including necessary MS clamps, bolts and nuts etc., including taking down the existing complete all as specified and as directed.
Galvinised iron tubing, light grade, 50mm bore with all accessories for cable protection fixed on poles/buildings or laid in trenches including necessary MS clamps, bolts and nuts etc., including taking down the existing complete all as specified and as directed.
Galvinised iron tubing, light grade, 80mm bore with all accessories for cable protection fixed on poles/buildings or laid in trenches including necessary MS clamps, bolts and nuts etc., including taking down the existing complete all as specified and as directed.
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr, connected to galvanized strip 25 x 4 mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles, check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No. 3 of SSR Part-I 2010 and as specified or indicated including earth work and excavation in any type of soil, PCC (1:3:6) type C1 chamber, pre cast RCC slab 40mm thick in Reinforced Cement Concrete (1:2:4) type B1 with 8 mm dia TMT bars reinforced at 10 cm centre to centre both ways including funnel with watering pipe wire mesh and lugs, including test point and testing on completion complete all as specified and as directed.
Earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge not less than 1.5 m below ground level connected to earth lead by GI wire 4 mm dia by means of bolts nuts, check nuts, washers made out of galvanised iron connected to main switch all as shown in elect plate No 3 of MES SSR Part -I includingn excavation and earth work in any type of soil,funnel, 20 mm dia light grade GI watering pipe with chamber of PCC 1:3:6 type C1 40mm thick of size 450mm x450mm (1:2:4) type B1 for cover slab reinforced with 8mm dia TMT bars 10cm c/c both ways and with 6mm MS hook etc complete all as specified including testing on completion all as specified and directed.
MCCB four pole, 100 Amps 16 KA with adjustable thermal settings, 415 volts, 50Hz including complete connections with incoming cable and out going cable with suitable thimbles and crimping the thimbles with crimping tools, insulating the naked portion with insulation tape including taking down the existing un serviceable MCCB complete all as specified and as directed.
MCCB four pole, 200 Amps 36 KA with adjustable thermal settings, 415 volts, 50Hz including complete connections with incoming cable and out going cable with suitable thimbles and crimping the thimbles with crimping tools, insulating the naked portion with insulation tape including taking down the existing un serviceable MCCB complete all as specified and as directed.
MCCB four pole, 250 Amps 36 KA with adjustable thermal settings, 415 volts, 50Hz including complete connections with incoming cable and out going cable with suitable thimbles and crimping the thimbles with crimping tools, insulating the naked portion with insulation tape including taking down the existing un serviceable MCCB complete all as specified and as directed.
MCCB four pole, 315 Amps 36 KA with adjustable thermal settings, 415 volts, 50Hz including complete connections with incoming cable and out going cable with suitable thimbles and crimping the thimbles with crimping tools, insulating the naked portion with insulation tape including taking down the existing un serviceable MCCB complete all as specified and as directed.
Cable jointing kit suitable for 1.1KV grade cable for straight through joint complete with jointing material and accessories suitable for 3.5 core / 4core XLPE armoured aluminium conductor cable of 25 to 50 sq.mm size including taking down the existing un serviceable joint complete all as specified and as directed.
Cable jointing kit suitable for 1.1KV grade cable for straight through joint complete with jointing material and accessories suitable for 3.5 core / 4core XLPE armoured aluminium conductor cable of 70 to 150 sq.mm size including taking down the existing un serviceable joint complete all as specified and as directed.
Cable jointing kit suitable for 1.1KV grade cable for straight through joint complete with jointing material and accessories suitable for 3.5 core / 4core XLPE armoured aluminium conductor cable of 185 to 300 sq.mm size including taking down the existing un serviceable joint complete all as specified and as directed.
Painting of PCC poles of any height and type with two coat of cement based paint with painting black and white strip or as ordered by Engineer-in-charge on poles up to 1.5 mtr high above coping level and numbering with writing letters or figures(Block), height not exc. 30 cm & letters or figures n.exc. 10 Nos, including security light mounting brackets with one coat of aluminium paint complete all specified and as directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including provision of HDPE pipe of 100 mm dia bore suitable for 0.4 mpa working pressure all as specified and as directed.
Dismantling the damaged concrete/ steel poles and struts of any size complete all as specified and as directed.
Steel tubular poles complete with cast iron plate, finial tapper plug, bolts nuts & screws as per type 410 SP -31 ,9 mtr long complete all as specified and as directed.
Plain Cement Concrete, (1:2:4), type B1, using 20mm graded stone aggregate, as in coping of pole, including necessary form work all as specified and as directed.
Plain Cement Concrete, (1:4:8), type D2 using 40mm graded stone aggregate as in pole foundation, stay assembly, including necessary form work all as specified and as directed.
Outdoor type, double door sheet metal enclosure / junction box of size 800x800x300 mm with aluminium bus bar of 200 Amps capacity suitable for 3 phase & neutral including MCCB, 4 pole, 415 volts, 100 Amps, 16 KA including removing old unserviceable junction box complete all as specified and as directed.
Outdoor type, double door sheet metal enclosure / junction box of size 800x800x300 mm with aluminium bus bar of 250 Amps capacity suitable for 3 phase & neutral including MCCB, 4 pole, 415 volts, 160 Amps, 36 KA including removing old unserviceable junction box complete all as specified and as directed.
Outdoor type, double door sheet metal enclosure / junction box of size 800x800x300 mm with aluminium bus bar of 400 Amps capacity suitable for 3 phase & neutral including MCCB, 4 pole, 415 volts, 250 Amps, 36 KA including removing old unserviceable junction box complete all as specified and as directed.
Cable fault finding in LT cables any size complete all as specified and as directed.
60 Watt LED street light fitting with pressure die cast housing along with prismatic polycarbonate modular secondary lens optics with IP 66 ingress protection and impact resistance of IK 08. 4kV in built and 10 kV external surge protection with top opening driver cover for easy maintenance including taking down old unserviceable street light fittings from pole all as per Halonix Cat No. HLSLD-15-60-CWL-R-SH/ Bajaj, Cat No. ENXT P 72 L WH CR PC SD or techno commercially equivalent makes specified in PS complete all as specified and as directed.
90 Watt LED street light fitting with pressure die cast housing and toughened glass and individual LEDs with secondary lens optics with IP 66 ingress protection and impact resistance of IK 07, 5kV inbuilt and 10 kV external surge protection with top opening driver cover for easy maintenance including taking down old unserviceable street light fittings from pole. all as per Halonix Cat No. HLSLD-10-90-CWL-I / Bajaj Cat No.BRTFG 90W LED CR echno commercially equivalent makes specified in PS complete all as specified and as directed.
Dismanling and taking out the LED street light fittings of any make from Pole and removing the burnt out /unserviceable LED driver of 25 Watt to 60 Watt capacity and replacement of new driver to make the fitting serviceable and refixing the fitting in existing / new location complete all as specified and as directed.
Moulded (FRP) junction box with IP 65 protection of size 300x200x80mm with 32 Amp 4 way heavy duty terminal block with 6Amp MCB SP and two number of cable entry gland of standard size with suitable MS bracket to fix with pole including taking down the existing complete all as directed.
Brackets made out of GI tubing medium grade 40mm bore of 1.50 mtr length bent to required shape and pattern to mount the street light, including MS clamps made out of MS flat iron 25 x 3mm, nuts, bolts, washers etc and applying two coats of alumium paint over a coat of red oxide primer including taking down the existing complete all as specified and as directed.
Sub main wiring with two runs of PVC insulated 2.5 sq.mm single core multi stranded copper conductor cable and one run of 2.5 sq.mm copper wire as earth continuity conductor drawn through and including rigid non metalic PVC conduit 20 mm external dia fixed on poles & connecting up all as specified and as directed. NOTE:- Two runs of cable and one run of earth wire and one run of conduit shall be measured as one length for payment purpose.
LED bulb 40 Watt with suitable size holder including dismanling and taking down old unserviceable CFL type street light fittings from pole, removing the unserviceable CFL and replacement of new LED and refixing in the existing / new location all as specified and as directed.
LED Post top lantern 40 Watt with die cast aluminium, spigot, spun aluminium powder coated top cover, heat sink, opal PC diffuser and clear acrylic IP-65 protection, including taking down old unserviceable lantern all as per HALONIX Cat No. HLPT-04-40-CW or techno commercially equivalent makes specified in PS complete all as specified and as directed.
LED bollard 10 Watts with MS pipe housing, glare free PMMA diffuser and IP 65 protectioncomplete including PCC(1;2:4) as in foundation work all as per HALONIX Cat No. HLOB-05-10-CW or techno commercially equivalent makes specified in PS complete all as as specified and as directed. all as specified and directed.
30 Watt LED security light fitting with pressure die cast housing, with secondary optics and IP 65 protection including taking out old fittings all as per HALONIX Cat No. HLSLD 09H-30-CWL-R / Bajaj, Cat No.:- BCLST 30W LED I or techno commercially equivalent makes specified in PS complete all as as specified and as directed. all as specified and directed.
120 Watt LED flood light luminaries, with ultra sleek, light weight and secondary optics made of pressure die cast housing with IP 66 ingress protection and impact resistance of IK 07 inbuilt including channel for fixing of wall with complete fitments, accessories all as per Halonix Cat No. HLFLD-ML01-120-CWL-R / BAJAJ Cat No. BJFL 120W LED I or techno commercially equivalent makes specified in PS including taking down the existing complete all as specified and as directed.
On load Change over switch 4 pole in sheet metal enclosure compact design rating 63Amps suitable for isolation and prevent leakage current/ flush over between phases, handle lock feature in off position with three padlocks all as per INDOASIAN Cat No. ITAS0063 or techno commercially equivalent makes specified in PS including taking down the existing complete all as specified and as directed.
LT 2 line separator, 230 volts, 50 Hz including dismantling the existing complete all as specified as directed
LT 4 line separator, 415 volts, 50 Hz including dismantling the existing complete all as specified as directed
Rollled mild steel work as in cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections of mild steel channel / angle iron / flat iron / round section of any size including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including dismantling the existing and inclusive of one red oxide primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and as directed
Pin type porcelain, vitreous white or brown insulator including one galvanized mild steel spindle, two galvanized iron washer and galvanized iron nut, size of insulator 100 mm height and 65mm dia suitable for 1100 volts grade supply including dismantling the existing complete all as specified and as directed.
Shackle type porcelain, vitreous white or brown insulator including one galvanized mild steel spindle, two galvanized iron washer and galvanized iron nut, size of insulator 75 mm height and 90mm dia suitable for 1100 volts grade supply including dismantling the existing complete all as specified and as directed.
Removal of existing ACSR conductors consisting of 6 lines at a distance of 30 mtr length in between the poles, tightening, restringing the same in between poles/insulators and connected with new binding wire, tightening to insulator including line clearence by pruning of tree branch approx 1 mtr apart from conductor and tightening the sides complete all as specified and as directed.
Dismantling of ACSR (Aluminium conductor steel reinforced) conductors complete all as specified and as directed.
ACSR (Aluminium conductor steel reinforced) conductor of any size on poles including binding wire of appropriate size complete including clearing of path and branch cutting of trees etc., all as specified and as directed
Removal of existing ACSR conductors in between the poles, tightening, restringing the same in between poles/insulators and connected with new binding wire, tightening to insulator including line clearence by pruning of tree branch approx 1 mtr apart from conductor and tightening the sides complete all as specified and as directed.
Stay assembly complete with all accessories as shown in electrical plate No 1 of SSR Part-I consisting of stay rod 20mm dia, 1.80 mtr long stay plate 230 x 230 x 6 mm with nuts, bolts, insulator stay clamps etc.,complete all as shown on drawing and as directed. NOTE:-Excavation, stay wire, loop type insulator, stay clamps, excavation and concrete shall be measured separately.
Galvanised stay strand, 7/4mm complete all as specified and direccted.
LED Solar Street light ALL IN ONE TYPE with inbuilt battery, SPV Module of capacity 12 Watt of light source and 12 watt SPV panel, IP 65 protection, lumeneous efficiacy 120 Lm /watt, Colour temperature 6000 K, battery 12.8 V,12 AH including charging system with overload protecion, light sensor devices, GI /MS pole of suitable dia of length 5 to 6 mtr duly painted etc all as per Halonix Cat No. HLSSLJNT0201010419 -18W-WOP-CWL / Bajaj Cat No: 152404 SOLAR BSZSL 12 W LED or techno commercially equivalent makes specified in PS including installation, testing and commissoning complete all as specified and as directed. NOTE:- Excavation , PCC required for foundation as per the manufacturer reccomendations shall be included in the quoted rate
LED Solar Street light ALL IN ONE TYPE with inbuilt battery, SPV Module of capacity 20 Watt of light source and 38 watt SPV panel, IP 65 protection, lumeneous efficiacy 120 Lm /watt Colour temperature 6000 K, battery 12.8 V, 18AH including charging system with overload protecion , light sensor devices, GI /MS pole of suitable dia of length 5 to 6 mtr duly painted etc all as per Halonix Cat No. HLSSLJNT0201020419 -20W-WOP-CWL / Bajaj Cat No: 152407 SOLAR BSZSL 20 W LED or techno commercially equivalent makes specified in PS including installation, testing and commissoning complete all as specified and as directed. NOTE:- Excavation, PCC required for foundation as per the manufacturer reccomendations shall be included in the quoted rate.
Vasavi Electricals
Shiva Shakthi Electrical Enterprises
Shanthi Construction
S S BUILDERS
GS TRADERS
M/S - KRUPA ELECTRICALS
K T ASSOCIATES
RRK PROJECTS
LITE SYSTEMS INDUS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .