| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.6 LAccepted-AOC SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹30.2 L+₹10.6 L (54.3%)Rejected-AOC | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹32.0 L+₹12.4 L (63.4%)Rejected-AOC | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹34.6 L+₹15.1 L (77.1%)Rejected-AOC GALA NO 08 D SOUZA SADAN OPP ANULAXMI ART PRINTERS NEAR GANESH MANDIR LOKMANAYA TILAK NAGAR A G LINK ROAD SAKINAKA MUMBAI 400 072 | MUMBAI SUBURBAN | MAHARASHTRA | 400072 | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹35 L+₹15.4 L (78.9%)Rejected-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹40.9 L
EMD Value
₹81,800
Closing Date
30 Apr 2024, 6:00 pmClosed
GE (NW) MANKHURD
GE (NW) MANKHURD
VARIOUS REPAIRS AND MAINT WORKS OF AC SYSTEM, DEHUMIDIFIER, DUCTING SYSTEM, CHILLED WATER AND CERTAIN REPAIRS/MAINT OF AC PIPE LINES, INSULATION, DUCTING, CONTROL WALLS AND CONNECTED AC WKS IN VARIOUS BLDG UNDER GE (NW) MANKHURD
2024_MES_648937_1
8348/E8
Open Tender
Civil Works
Item Rate
180 days
GE (NW) MANKHURD
As per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE (NW) MANKHURD
₹81,800
2 Nov 2024
2 Apr 2024
2 May 2024
2 Apr 2024
30 Apr 2024
15 Apr 2024
Amount
Supply and fixing in replacement /suction Discharge stop valve housing 3" confrming to cat part No ASL-6026-3 of ACCEL complete all as specified and as directed.
M&L for disconnecting from electic supply and dismentaling from foundation, taking out opening completely fo servicing of 30 TR Chiller unit comprising of compressor and sqiurral cage induction motor of any type and capacity including complete removal dust/ slug/rust found on any part movable/immovable, and replacement U/s bearings of any type (Pedestal/Roller) and refixing the the same after checking complete alignment with base and alliged units complete. (i)Replacement of oil filter (ii) Cleaning/ servicing of all flow lines R22 gas / Water lines completerly (iii) Checking, Repair& Setting all controls,solenoid valves, therr way valves,relays, termostat, humidistat and other relateted equiments/ control for effictve and smooth funtioning (iv) M&L for Charging of Refrigerant Gas (R-22) and compressor oil including repair of leakage observed if any and maintaing requiste test pressure and pressure testing for 08 hours at full load condition to achieve desired condition inside the building to the entire satisfaction of Engg- in - charge (v) Dismentaling and taking out oil saperator vessel completly for cleaning of wire mesh screen, checking of heater, thermostat, regulated controls and calibration , setting of controls to meet reqiusite inside conditions (vi) Dismentaling and taking out filter drier completly for cleaning of wire mesh screen, checking of regulated controls and setting of controls to meet reqiusite cleanness (vi) Tightening the power circuit electrical conections, Control and command connections,correct bthe operation of heaters as per tightening torque table of OEM (vii) Checking/ setting of all operating / funtional /handling parameters for safe and economical operation of plant throuh out the period. Cost for Refrigerant Gas (R-134a) and compressor oil required shall be included under this item.
M&L for servicing of cooling tower suitable for 60 TR AC plant through cleaning re-agent complete pipe line, including servicing of cooling tower motor and fan and make the necessary alignment with motor and replacement of bearing of suitable cap after necessory work including gressing and replacement of nut bolts and preventing leakage if any by means of suitable adetives etc all as directed and specified. Note : The cost labour charges for cleaning of PVC Fills and refixing including minor spare parts if any required at the time of repair is deemed to be included in the quoted rates of the job. Replacement of PVC Fills will be paid separately under respective items of BOQ.
M&L for disconnecting electrical connections 7.5 HP motor located at the top of cooling tower,keep cables at safe custody for reconnection and dismantling and taking out fan blade assembly along with motor mounted on base frame at the top of cooling tower after cutting all nuts, bolts and fixtures from the mounting frame and removing whole assembly including motor and base frame from the top of cooling tower with the help of T&P for servicing of cooling tower suitable for 150 TR capcity including following complete for servicing cooling tower plant through cleaning re-agent complete pipe line, including servicing of cooling tower motor and fan and make the necessary alignment with motor and replacement of bearing of suitable cap after necessory work including gressing and replacement of nut bolts and preventing leakage if any by means of suitable adetives etc all as directed and specified. (a) Cleaning /scrapping of inner& outer surface of FRP basin, repair of damaged portion if any to and for FRP lining of all surfaces joints to avoid leakage including replacement of all nuts and bolts joining all parts of Basin complete (b) cleaning U/s PVC fills(Big size ) in colums of size 60x30x15 cm (c) Cleaning Existing U/s PVC fills(Big size ) in colums of size 60x30x15 cm (d) Replacement of bearings -2 Nos (e) Replacement of protection Guard/ frame for mounting PVC fills fabricated with round bar not less than 10 mm dia completely to the shape of Cooling tower all as per existing and suitable to sustain load of sprilkler assembly and Fills & motor - 2 Nos
-ditto- all as per item No. 4 above but for 15 HP motor complete all as specified and directed.
M&L for Dismentaling and servicing of Air handling unit of capacity 12000-13000Cfm, sectionalised construction of capacity 30 TR and reinstalled in same position with correct alignment after cleaning /repairing remove the all rust from shaft by machinery work and rebalancing of shaft including replacement of unserviceable following parts Replacement of pedestal bearings-2 No Replacement of ball bearings-2 No Removing of pulleys from shaft by using T & P for cleaning/grinding/maching of shaft and pulleys maching of grooves/ grasing of all movable parts complete
M&L for servicing and descaling of cooling coil 4-6 Row Deep of capacity 30 TR through cleaning agent and remove the oil and dust from fines and cooper tubes/ pipes complete and checking of copper tubing for leakage of water complete all as directed by engineer in charge
M& L Supply, fabricating and fixing structural mild steel RS joist, channel, angle iron, flat iron and brackets etc for fabrications for cross arms supporting, clamps and back plates, including nuts, bolts and washers, welding to shapes for fabrication of structure to support cooling tower / fondation base to pumps/ compressor/chiller including required nuts, bolts and washers including necessary cutting/ jointing/welding with and including two coats black bituminous paint over a coat of red oxide primer all as required at site
M & L for supply laying connecting and testing of flexible cable 4 runs single core16 sqmm copper conductor laid in trenches in incl;uding clamps of suitable size to fix the cable on wall of trenches and from main panel control panel to chiller unit 30 TR capacity.
M&L for servicing of chiller / condensing pump & remove the all dirt,rust of shaft impellor by machinery work etc and replacement unserviceable bearings of capaicty 20/15 HP and gland packing, studs and nut bolts with bushes etc as required at site all as directed by Engr-in-Charge.
-do- but 10 HP pump.
Material and labour for replacement of galvanised iron tubing medium grade sizes 25 mm dia including accessories such as socket, bends, clamps etc fixed to walls/floors/ laid in trenches supply of water from make up tank to cooling cooling tower all as specified. Note : Rates are deemed to include making good of the disturbed surface. 2. Earth work required in the above mentioned work shall be measured and paid saperately Make : Prakash Surya/ Jindal
Supply and fix in repair of Panel Mounting type contactor of any make, model and capcity from the existing position and supply and fix 25 -32 Amps of MN-25 & MN-16 with overload relay range 3 -5 Amps, for 3 phase, 50Hz Std. Coil Voltage :240/415/ 440V, 50Hz AC supply all as directed by Engr-in-Charge. Make - L&T/C&S/BCH
Supply and fix in repair of Panel Mounting type contactor of any make, model and capcity from the existing position and supply and fix 63 Amps with overload relay range 5-8 Amps, for 3 phase, 50Hz Std. Coil Voltage :240/415/ 440V, 50Hz AC supply all as directed by Engr-in-Charge. Make - L&T/C&S/BCH
M & L for Motor protection Relay Digital with over current and under current,Phase loss/Phase unbalance/ Phase reversal protection for 7.5 To 20HP Make BCH Model No BCOR3EZ Cat. No: MP363EZ800B4
Supply & fix in replacement of prefilters/ fine filters box type with washable nylon filitters media having 90% efficiency to control dust particles upto 10 microns fitted in aluminium framed with both side wire mesh of size500x500x50mm and for fine filters 90% efficiency to control dust particles upto 10 microns 500x500x305mm as per sample suitable for 30 TR AC plant.
Supply & fix in replacement of prefilters/ fine filters box type with washable nylon filitters media having 90% efficiency to control dust particles upto 10 microns fitted in aluminium framed with both side wire mesh of size610x610x50mm of class EU-4and for fine filters 99% efficiency to control dust particles upto 10 microns 610x610x305mm EU-5 as per sample suitable for 30 TR AC plant.
M&L for job to be carried out every three months period to check and made serviceable for the air cooled DX type chiller upto 60 TR capacity installed at AC plant with & including following all as directed and specified by OEM Ton capacity (i)Replacement of oil filter (ii) Cleaning/ servicing of all flow lines 134A gas / Water lines completerly (iii) Checking, Repair& Setting all controls,solenoid valves, therr way valves,relays, termostat, humidistat and other relateted equiments/ control for effictve and smooth funtioning (iv) M&L for Charging of Refrigerant Gas (R-134A) and compressor oil including repair of leakage observed if any and maintaing requiste test pressure and pressure testing for 08 hours at full load condition to achieve desired condition inside the building to the entire satisfaction of Engg- in - charge (v) Dismentaling and taking out oil saperator vessel completly for cleaning of wire mesh screen, checking of heater, thermostat, regulated controls and calibration , setting of controls to meet reqiusite inside conditions (vi) Dismentaling and taking out filter drier completly for cleaning of wire mesh screen, checking of regulated controls and setting of controls to meet reqiusite cleanness (vi) Tightening the power circuit electrical conections, Control and command connections,correct bthe operation of heaters as per tightening torque table of OEM (vii) Checking/ setting of all operating / funtional /handling parameters for safe and economical operation of plant throuh out the period. Cost for Refrigerant Gas (R-134a) and compressor oil required shall be included under this item.
M & L for replacement of chilled water tank thermocal insulationed and providing new chilled water storage tank capcity 1000 Ltrs to compensate chilled water line losses fabricated with 6mm thick MS Plate duly insulated from all sides with thermocoal insulation TF quality insulation of 80mm thick duly wraped and stiched and duly pasted with siporex compound covered with polysterene sheet and chicken wire mesh duly wraped and covered aluminium sheet of 24 gauge thickness and two coats of for cement plaster applied over it after water proofing including mounting stand made up of angle iron/channel not less than 50X6mm including GI pipe of 40mm dia from tank all as directed.
Dismantling the existing 30 TR capacity condenser from top of the existing unit, disconnecting the inlet and outlet connections of gas & water, transporting the same to the workshop, opening both flanges, boring, taking out complete existing 95 Nos damaged/choked finned copper tubes each of 1.94 metre long & of size 1/2" dia, replacing all the 95 Nos tubes with new finned copper tube of size 1/2" dia & each of 1.94 metre long, pressure testing at workshop, transporting the repaired condensor to the site,reinstalling at site on the top of existing unit, connecting the inlet & outlet connections, welding,boring etc, pressure testing with nitrogen, vaccumizing, gas charging, testing on load for smooth functioning, complete in all respects, all as specified and directed. (Location: Condenser No. 1 installed in 60 TR AC Plant at EKM WKS) Note: Supply only refrigerent for topping-upshall only be paid for separately to the extent required and ordered.
M& L for Material and labour Dismantling and taking out motor TEFC 1.0 HP capacity from base for Servicing of motor overhauling including greasing of all moveable parts including rewinding of stator assembly of motor 1.0HP capacity of CSU 3.0 TR capacity with super enameled copper wires of suitable gauge and duly insulated with Class E insulated material and varnishing complete and refitting same after repair including transportation to W/s and back reassembling and reconnecting with CSU blower and testing on full load for entre satisfaction of Engr-in-Charge
Supply and fix in repairs, installing, commissioning and testing of FRP induced draft round/ rectangular type counter flow cooling tower of capacity 60 TR supported over hot dip galvanised steel structure, fitted with axial flow fan, direct driven, operated with 3 phase 415 V AC supply . PVC/Polpropylene fills/Nozzels with maximum allowable temperature 50 degree centigrade, drift losses 0.005% of water circulation with suitable foundation and float valve of suitable size complete all as specified. Make : Mihir or equivalant to advance make.
Supplying laying fixing connecting & testing PVC insulated 1100 volts grade PVC sheathed conductor cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded Copper conductor of size 16 core 1.5 sqmm calble 1100 Volts grade for indication control of AHU ( Note: Necessary Earth work required for laying cable, sand Cusioning, protection cover/ GI pipe light grade are measured and paid saperately)
M&L for plain concrete cement 1:3:6 type C-2 using 40mm graded stone aggregate in foundation of PCC poles as spentied including necessary form work all as specified and directed.
M&L for plain concrete cement 1:3:6 type C-1 using 20mm graded stone aggregate in copping of PCC/Steel poles/ MS ISMC structure as spentied including necessary form work and fair finishing to surface by using extra cement all as specified and directed.
Supply and fix in repairs install, testing and commissioning of double skin, floor mounted, Air handling unit 6 rows deep cooling coil of Suitable capacity , 50TSP and comprising of the following : (i) 6 Row Cooling coils of copper tube with aluminium fins. (ii) Prefilter. (iii) Blower for AHU with suitable motor, TEFC scroll case induction motor for operation on 415 volts, 3 phase, AC supply with suitable starters with overload protection and single phase preventors with V belt and guard. (iv) Insulation of AHU as specified. Make : Zeco or equivalant Voltas/Blue star
Material and labour for repairs to Microprocessor of 30 TR Capacity AC Plant chiller unit including replacing diods, transistors and wiring etc all as specified and directed.
Supply and fix in replacement MCCB, FP, 415 V, fixed type of undermentioned capacity complete all as specified and directed : (Make : STANDARD/HAVELLS/INDO-ASIAN) MCCB 250 Amp, FP, 415-V, breaking capacity 35 KA
MCCB 100 Amp, FP, 415-V, breaking capacity 25 KA
MCCB 63 Amp, FP, 415-V, breaking capacity 16 KA Note for item Nos 30 to 32 : The quoted rates shall also be deemed to include for taking down of existing MCCB's from Panels after disconneting of cable and provision of new MCCB's, reconnecting of cables with and including proper lugs and glands.
Supply only compressor oil as per requirement, complete all as specified and directed, Make :Servo, HP, BP, Sheetal N-68, Freezol 36
Supply only refrigerant (R-22) gas as per requirement, complete all as specified and directed. Make : MAFRON/FLORON/ REFRON/ FREON NOTE FOR ITEM NOS. 1 TO 2: The quantity of the above items shall only be operated to the extent required for topping-up as specified in the relevant other connected items of BOQ.
Supply and fix in repairs automatic capacity control pilot solenoid valve suitable for the liquid line of AC Plants of various capacity complete all as specified and directed, Make :- Rotex, Avcon, SPORLAN, DANFOSS.
M & L for thermal insulation of 150mm bore chiller water piping with 50mm thick fibre glass wool, crown 150 and of density 24 Kg/Cum, the glass wool shall be covered with and including 24 SWG aluminium sheet cladding, complete all as specified and directed, Make: Lloyd's / TWIGA/ FGP Ltd.
-Dittio- all as per item No. 34 above but of 80mm bore chiller water piping
-Dittio- all as per item No. 34 above but of 50mm bore chiller water piping
Pumping down the existing refrigerant from the plant of 75/80 TR capacity, carrying out the leakage testing of plant with the pressure of Nitrogen gas and monitoring for 24hrs to assess leakages, rectification of leakage by brazing & replacement of necessary gaskets wherever required, vacumizing of the plant by vaccum pump and keep-it upto 24 hours for testing and rectification of leakages if any, finally recharging of existing refrigerant gas to the plant and topping up of refrigerant if required to maintain the standard pressure etc complete including testing of the plant for smooth functioning complete all as specified & directed. Location : Missare Mine, TS Mahul
Supply and fix in repairs hi wall split units indoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality including taking down old u/s indoor AC unit of capacity 2 Ton electric driven single phase 230 Volt complete all as specified and directed.
-ditto- all as per item No 38 above but for 1.5 Ton capacity complete all as specified and directed.
Supply and fix in repairs hi wall split units outdoor (Condener unit) of capacity 2 Ton including filling of refrigerant including taking down old u/s outdoor AC unit complete all as specified and directed.
-ditto- all as per item No 40 above but for 1.5 Ton capacity complete all as specified and directed.
Supply only in repairs cordless remote control unit suitable for capacity of 2 / 1.5 Ton suitable for window/ Split AC complete all as specified and directed.
Pumping down the existing refrigerant from the plant of 30 TR capacity, carrying out the leakage testing of plant with the pressure of Nitrogen gas and monitoring for 24hrs to assess leakages, rectification of leakage by brazing & replacement of necessary gaskets wherever required, vacumizing of the plant by vaccum pump and keep-it upto 24 hours for testing and rectification of leakages if any, finally recharging of existing refrigerant gas to the plant and topping up of refrigerant if required to maintain the standard pressure etc complete including testing of the plant for smooth functioning complete all as specified & directed, Location : 31 WEU, WED & NAD. Notes for Item Nos. 41 to 43: (i) Refrigerant required for topping up will be measured and paid seperately as supply only under relevant item. (ii) These items are not applicable for the compressors considered in Item No. 34, 36 & 38.
S & F in replacement loader / Unloader coil 230 Volt, 50HZ for solenoid valve suitable for compressor SMC 6-65 / 8- 65 Model, Make : ACCEL
-Ditto- all as per item No. 44 above but for SMC 8-100, Make ACCEL.
Taking down existing unserviceable Shaft Seal assembly and in lieu S & F new Shaft Seal Assembly of Make ACCEL including tear gasket, nuts, bolts, washers etc. and testing for leakage of refrigerant suitable for 75/80 TR Capacity chiller unit, Make -ACCEL, complete all as specified and directed.
-ditto- all as per item No. 46 hereinabove but Shaft seal Assembly of Make -ACCEL for 30/40 TR capacity chiller unit
-ditto- all as per item No. 46 hereinabove but shaft seal Assembly of Make -ACCEL for 15/21 TR Capacity chillar unit of Make ACCEL.
S & F in replacement unserviceable worn out 'V' belt of model A-64 of Fenner or equivalent in Nirlon/Dunlop as approved by the GE for Compressor / AHU etc. complete all as specified and directed.
S & F in replacement unserviceable worn out 'V' belt of model B-66 of Fenner or equivalent in Nirlon/Dunlop as approved by the GE for Compressor/ AHU etc. complete all as specified and directed.
S & F in replacement unserviceable worn out 'V' belt of model B-78 of Fenner or equivalent in Nirlon/Dunlop as approved by the GE for Compressor/ AHU etc. complete all as specified and directed.
S & F in replacement unserviceable worn out 'V' belt of model C-102 of Fenner or equivalent in Nirlon/Dunlop as approved by the GE for Compressor/ AHU etc. complete all as specified and directed.
S & F in replacement unserviceable worn out 'V' belt of model C-108 of Fenner or equivalent in Nirlon/Dunlop as approved by the GE for Compressor/ AHU etc. complete all as specified and directed.
S & F in replacement unserviceable worn out 'V' belt of model B-110 of Fenner or equivalent in Nirlon/Dunlop as approved by the GE for Compressor/ AHU etc. complete all as specified and directed.
S & F in replacement unserviceable worn out 'V' belt of model C-134 of Fenner or equivalent in Nirlon/Dunlop as approved by the GE for Compressor/ AHU etc. complete all as specified and directed.
S & F in replacement contactor type ML- 1.5, 415Volt, 50Hz for star delta starter for motor of compressor, water pump and chiller pump etc. complete all as specified and directed, Make L & T/ Marline - Garline/ SIEMENS/ Schneider
S & F in replacement contactor type ML- 2, 415Volt, 50Hzfor star delta starter for motor of compressor, water pump and chiller pump etc. complete all as specified and directed. Make L & T/ Marline - Garline/ SIEMENS/Schneider
S & F in replacement contactor type ML- 3, 415Volt, 50Hz for star delta starter for motor of compressor, water pump and chiller pump etc. complete all as specified and directed. Make L & T/ Marline - Garline/ SIEMENS/Schneider
S & F in replacement contactor for type ML- 6, 415Volt, 50Hz for star delta starter for motor of compressor, water pump and chiller pump etc. complete all as specified and directed. Make L & T/ Marline - Garline/ SIEMENS/Schneider
M & L for replacement of unserviceable Cooling Tower accessories i.e. Nozzelles, water inlet/out pipe and filter, fanblade, fan bulb, fan shaft, GI bolts, nuts, MS frame and ladder etc complete and refitting old PVC fills (serviceable qty shall be reused to the extent available) after cleaning with diluted HCL solution suitable for the cooling tower of 21 to 40TR of FRP Basin, complete all as specified and directed. Note : Extra PVC fills required to complete the job shall only be measured and paid separately as supply only to the extent required and ordered and cost of all the other elements to make the cooling towers completely functional shall be deemed to be included in the quoted rates.
Supply only PVC fills of size 600mm x 300mm x 150mm complete all as specified and directed.
Supply only PVC fills of size 600mm x 150mm x 150mm complete all as specified and directed.
M & L for replacement of relay for 100 HP Starter installed in Panel Board of AC Plant Installation, complete all as specified and directed, Make : L & T / SIEMENS.
M & L for replacement of relay for 40 HP Starter installed in Panel Board of AC Plant Installation, complete all as specified and directed, Make L&T / Siemens.
M & L for replacement of relay for 20/25 HP Starter installed in Panel Board of AC Plant Installation, complete all as specified and directed, Make L&T / Siemens.
M & L for replacement of relay for 10 HP Starter installed in Panel Board of AC Plant Installation, complete all as specified and directed, Make L&T / Siemens.
M & L for replacement of relay for 7.5/5 HP Starter installed in Panel Board of AC Plant Installation, complete all as specified and directed, Make L&T / Siemens.
M & L for replacement of relay for 3 HP Starter installed in Panel Board of AC Plant Installation, complete all as specified and directed, Make L&T / Siemens.
M & L for replacement of Timer 800 SD. installed in Panel Board of AC Plant Installation, complete all as specified and directed, Make L&T or Siemens
M & L for replacement of Indicator lamp RBY, 230 V, installed in Panel Board of AC Plant Installation, complete all as specified and directed, Make L&T / Siemens/C&S.
S & F in repairs for expansion valve suitable for AC plant of 75 TR/80TR chillar unit, Make ACCEL, complete all as specified and directed, Make: DANFOSS / SPORLAN / RANCO.
-ditto- all as per item No. 71 above but for AC 30/40 TR chillar unit, Make : ACCEL
-ditto- all as per item No. 71 above but for AC 15/21 TR chillar unit, Make ACCEL
Supply and fix in replacement single phase preventer, type SPPR Type SZ 5 (7 Wire), 380V suitable for existing panel board for AC Plant, complete all as specified and directed, (Make L&T / SIEMENS).
Replacement of unserviceable MS pipe, heavy grade of following sizes (condenser water tubing from the cooling tower area) including provision of all fittings, welding and connected works as required for smooth functioning of AC Plants, complete all as specified and directed, Make : TATA/JINDAL :- (a) 150mm bore
(b) 100mm bore
(c) 80mm bore
(d) 65mm bore
(e) 50mm bore
Supply, Fabrication, Installation, Testing and Commissioning of ducting for supply/Return mode out of GI steel metal 22 gauge, Zinc coated complete with all standard accessories, flanges, G I Hardware, Self Adhesive elastomeric foam gasket, support etc as per IS-655, complete all as specified and directed.
M&L for duct insulation (50 mm thick) with resin bonded fibre glass wool roll of density 24 Kg/Cum, with factory laminated aluminium vapour barrier, as specified and includign the followings : (a) M&L for cleaning the duct surface (to be insulated) by scrapping carefully with wire brush etc to make the surface completely free of miss-scale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) M&L applying rubber based adhesive CPRX compound. (c) M&L for sealing of all longitudinal joints and circular overlaps with and including aluminium foil tape 50mm wide, to make the insulation leakproof. (d) M&L for securing the insulation with and inculding mechanically fastened nylon / steel straps of size 50mm wide at maximum intervals of 1.2 metre.
Suply and fix in repairs butterfly valve including flange, nuts, bolts, rubber, gaskets etc suitable for 50mm bore pipe, complete all as specified and directed.
Suply and fix in repairs butterfly valve including flange, nuts, bolts, rubber, gaskets etc suitable for 80mm bore pipe, complete all as specified and directed.
Suply and fix in repairs butterfly valve including flange, nuts, bolts, rubber, gaskets etc suitable for 100mm bore pipe, complete all as specified and directed.
Suply and fix in repairs butterfly valve including flange, nuts, bolts, rubber, gaskets etc suitable for 150mm bore pipe, complete all as specified and directed.
Suply and fix in repairs Non-return butterfly valve including flange, nuts, bolts, rubber, gaskets etc suitable for 100mm bore pipe, complete all as specified and directed.
Suply and fix in repairs Non-return butterfly valve including flange, nuts, bolts, rubber, gaskets etc suitable for 150mm bore pipe, complete all as specified and directed.
Suply and fix in repairs Non-return butterfly valve including flange, nuts, bolts, rubber, gaskets etc suitable for 80mm bore pipe, complete all as specified and directed. NOTE: Make for items 49 to 55 : KRILOSKER/LEADER/KARTAR /ZOLOTO
Supply and fix in repairs installing, commissioning and testing of FRP induced draft round/ rectangular type counter flow cooling tower of capacity 30 TR supported over hot dip galvanised steel structure, fitted with axial flow fan, direct driven, operated with 3 phase 415 V AC supply . PVC/Polpropylene fills/Nozzels with maximum allowable temperature 50 degree centigrade, drift losses 0.005% of water circulation with suitable foundation and float valve of suitable size complete all as specified. Make : Mihir or equivalant to advance make.
Supply and fix in repairs Pot stainer CI 65 mm complete with companion flanges, nuts, bolts gaskets etc and confirming to PN -16 ratings, all as specified and directed.
Supply and fix in repairs Pot stainer CI 100 mm complete with companion flanges, nuts, bolts gaskets etc and confirming to PN -16 ratings, all as specified and directed. Note : A sum of Rs. 93,892.00 towards sch of credit shall be deducated to arrive the contract sum.
AIRDOT ENGINEERING
INDIAN AIR CONDITIONING SERVICES
joshua construction
Shree Ayyappa Engineering
R J ENTERPRISES
M/s Mukesh Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .