Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹28.7 LAccepted-AOC | L-1 | Accepted-AOC The work has been Completed |
Tender Value
Refer Docs
EMD Value
₹22,543
Closing Date
14 Jun 2022, 5:30 pmClosed
P K JAIN
ISBT, Electric Section
Estimate for Internal Electrification work at Building Permission office ward 48 and 10 no. market zone office ward 45 under Zone 9 with 2 yrs Defect Liablity Period DLP and 3 yrs comprehensive maintanence contract CMC. ( Second Call)
2022_UAD_199842_2
2020206216
Open Tender
Electrical Works
Fixed-rate
60 days
ISBT, Electric Section
AS PER TENDER DOCUMENT
9 documents required · 9 mandatory
₹5,000
₹22,543
27 Sept 2024
31 May 2022
15 Jun 2022
31 May 2022
14 Jun 2022
31 May 2022
Amount
Estimate for Internal Electrification work at Building Permission office ward 48 and 10 no. market zone office ward 45 under Zone 9 with 2 yrs Defect Liablity Period DLP and 3 yrs comprehensive maintanence contract CMC.
4000000723-Tube light LED 1 X 18W Supply and fixing Led tube rod comprising of LED tube with non-integral/integral driver, upto 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with system efficacy> 100 lm/Watt. LED driver PF> 0.95 & THD <(><<)> 20%. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106(2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. Tube light LED 1 X 18Watt, Integral i/c batten aluminium body, PC diffuser. (AS PER PWD SOR - 2020)
3000014142-9 Watt250Volt Supply and fixing in position LED lamp of approved make. 9 Watt250Volt (AS PER PWD SOR - 2020)
3000014143-Same board switch & socket 16 Amp Same board switch & socket 16 Amp./S.S. combined 20/16/6 Amp(AS PER PWD SOR - 2020)
3000014145- Short point Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :- Short point
3000014146-Medium point Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :- Medium point (AS PER PWD SOR - 2020)
3000014148-Long point Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :- Long point (AS PER PWD SOR - 2020)
3000014149- Extra long-I Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :- Extra long-I (AS PER PWD SOR - 2020)
3000014150-1.0 TR star rating 3 star Split AC (non inverter) :- Supply installation testing and commissioning of split type wall mounted air conditioning unit of following capacity including indoor, outdoor unit fitted with rotary compressor, copper condenser and first charge refrigerant R410A. The condensing unit working range should be capable of providing cooling between +/-5deg.C to 50 deg. C including connection of copper pipe of required size upto 3 mtr., insulation, cordless remote control, auto air swing louvers, wall stand for outdoor unit, connection copper lead wire, condense water outlet pipe 2 mtr. complete etc as required. Outdoor/indoor units should be of same make (brand). 1.0 TR star rating 3 star (AS PER PWD SOR - 2020)
3000014153-1.5 TR star rating 3 star Split AC (non inverter) :- Supply installation testing and commissioning of split type wall mounted air conditioning unit of following capacity including indoor, outdoor unit fitted with rotary compressor, copper condenser and first charge refrigerant R410A. The condensing unit working range should be capable of providing cooling between +/- 5deg.C to 50 deg. C including connection of copper pipe of required size upto 3 mtr., insulation, cordless emote control, auto air swing louvers, wall stand for outdoor unit, connection copper lead wire, condense water outlet pipe 2 mtr. complete etc as required. Outdoor/indoor units should be of same make (brand). 1.5 TR star rating 3 star (AS PER PWD SOR - 2020)
3000014156-Telephone wire 0.5 mm, 4 Pair Supplying and drawing following pair, 0.5 mm PVC insulated copper conductor unarmoured telephone cable in existing surface/concealed, steel/PVC conduit as required. Telephone wire 0.5 mm, 4 Pair (AS PER PWD SOR - 2020)
3000014159-4 Pair un-shielded twisted pair (UTP) Supplying and drawing 4 pair un-shielded twisted pair (UTP), 0.5 mm PVC insulated copper conductor un-armoured Cat-6 computer cable FRLS in existing surface/concealed, steel/PVC. conduit/ casing-n-capping as required.(AS PER PWD SOR - 2020)
3000014160-30 minute backup, min. 6000 VAH Supply, installation, testing and commissioning of UPS with isolation transformer & battery for backup, having three phase input with ground (R-Y-B-N-G), Voltage range 190v AC-478v AC (based on load %), line low transformer (0-50% :190v/51-100% : 305v ± 3% VAC), line low comeback +25 - 35 VAC ( ± 3%), line high transfer 478 VAC (± 3%), line high comeback 461 VAC (± 3%), frequency range 46 - 54 Hz, power factor 0.99, Total harmonic distortion (current)-THDi (<(><<)>5% with full load, having output voltage 220 VAC/230 VAC/240 VAC, voltage regulation ± 1%, frequency 50 Hz ± 0.1 Hz, Synchronization range 46 -54 Hz, voltage distortion ≤2 % (linear load) & ≤5 % (nonlinear load), having pure sine wave output waveform, crest factor 3 : 1, efficiency (AC -AC) 94%, power factor 0.9, having inbuilt isolation transformer, over load 101 - 109% : 5 Min, 110 - 129% : 1 Min, 130 - 150% : 10 sec, having SMF/VRLA battery type, transfer time line mode to battery mode 0 ms, inverter to bypass, ECO mode 0 ms, bypass to inverter 0 ms, ECO to inverter mode <(><<)> 10 ms, when bypass voltage of frequency is out of range, having features Eco mode, Fan speed control, EPO function, frequency converter mode & parallel function (optional) up to 4 units. Operating temperature 0 - 45°C, noise level <(><<)> 55 db @ 1 meter having display & indication features i.e. user friendly dot matrix LCD display, input : voltage & frequency, battery : voltage & level in %, internal DC bus voltage z frequency, current, power& load level in %), UPS status (operating mode/warning/fault/codes (fault & warnings), UPS settings (output voltage/ frequency/ bypass enable/disable/special function., UPS/CVCF/ECO. LED status (normal mode/load on battery/load on bypass/system fault), Audible alarm (main failure alarm, low battery alarm, UPS warning, overload, fault & bypass mode etc.), protections (advance electronic protection for device, safety backed with MCBs, fast acting fuses, high speed pulse blanking, electronic overvoltage/under voltage), connections (terminal block for input/bypass/battery & output), static bypass, communication interface RS 232/USB port for software interface, intelligent slot for SNMP (optional). UPS installation with all required material arrangements as required as per IS specification. 7.5 KVA (3 phase input & 1 phase output) For 30 minute backup, min. 6000 VAH (AS PER PWD SOR - 2020)
3000014161- Projector and projector screen Supply and installation of Projector and projector screen etc. (as per specifications enclosed)
3000014162-Air Curtain Supply and installation of Air Curtain (as per specifications enclosed) MAKE- Almonard/Mitsubishi/Technocrats
4000000753-1.8 TR/2.0 TR single phase Cassette AC :- Supply installation testing and commissioning of split type ceiling cassette Slim line/floor standing air conditioning unit of capacity including indoor, outdoor unit fitted with rotary compressor, copper condenser and first charge refrigerant R410A/ecofriendly green gas only, cordless remote control, auto air swing louvers, connection copper lead wire between outdoor and indoor unit, connection copper lead wire upto 1.5 mtr., excluding connection copper pipe of required size, insulation, floor stand for outdoor unit, condense water outlet complete etc as required. Outdoor/indoor units should be of same make (brand).Ceiling suspended/mounted cassette type 4 way unit with inbuilt drain pump & decorative panels. 1.8 TR/2.0 TR single phase (AS PER PWD SOR - 2020)
4000000755-2.7/3.0 TR three phase Cassette AC :- Supply installation testing and commissioning of split type ceiling cassette Slim line/floor standing air conditioning unit of capacity including indoor, outdoor unit fitted with rotary compressor, copper condenser and first charge refrigerant R410A/ecofriendly green gas only, cordless remote control, auto air swing louvers, connection copper lead wire between outdoor and indoor unit, connection copper lead wire upto 1.5 mtr., excluding connection copper pipe of required size, insulation, floor stand for outdoor unit, condense water outlet complete etc as required. Outdoor/indoor units should be of same make (brand).Ceiling suspended/mounted cassette type 4 way unit with inbuilt drain pump & decorative panels. 2.7/3.0 TR three phase (AS PER PWD SOR - 2020)
3000014172-Full comprehensive Maintenance for 3rd Full comprehensive Maintenance for 3rd year
3000014173-Full comprehensive maintenance for 4th Full comprehensive maintenance for 4th year
3000014174-Full comprehensive maintenance for 5th Full comprehensive maintenance for 5th year
Bidder Name
Amount
RIGHTWAYS CONSTRUCTIONS(GSTN-23ATGPK9601E1ZZ)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .