ARVIND KUMAR RISHI ,PE (EnM),SDOCM
OFFICE OF THE PROJECT OFFICER,SDOCM,DHORI AREA,CCL
Repair and Maintenance of 11 KV overhead Line Main Feeder from Dhori Main Distribution Substation to SDOCM Project Sub Station including replacement of damaged poles etc. for a route length of 5.0 KM approx as required in respect of SDOCM of Dhori Ar
2025_CCL_334959_1
SDOCM/PE(EnM)/e.NIT/25-26/03 dt.04.05.2025
Open Tender
Electrical and Maintenance Works
Item Wise
30 days
SDOCM
Please refer Tender documents.
2 documents required · 2 mandatory
₹15,100
6 Jun 2025
5 May 2025
16 May 2025
5 May 2025
15 May 2025
5 May 2025
5 May 2025 - 8 May 2025
Amount
Erection of steel tubular pole in cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts etcas required.
Erection of ACSR conductor of 7/3.35 mm to 7/4.0 diameter and above including binding etc as required (1.8 km x 3 wire = 5.4 km x 394 kg/ km = 2127.6 kg)
Supplying of channel iron 50 mm x 8 mm M.S.flat iron pole top bracket cross arm for single 11 KV OH line conductor complete with fixing clamps bolts and nuts including drilling holes for insulators pins bolt and nut etc and painting with primer and finish paint as required
Supplying of Channel iron 75 mm x 40 mm x 6 mm (7.14 kg per mtr). bracket cross arm for two 11 KV OH line conductor complete with 50 mm x 50 mm x 6 mm angle iron welded to the channel iron and complete with 50 mm x 6 mm M.S Flat iron clamps, bolts, nuts and including drilling holes for insulators pins bolt, nuts and washers etc (as per drawing) and painting with primer and finish paint as required
Supply of 8 SWG GI wire for earth continuity (1200 m x 0.131 kg/mtr = 157.20 kg)
Supply and erection of 11 KV Pin insulator complete with large steel head GI in nuts and washers etc as required.
Supply and erection of 11 kv disc insulator for 11KV over head lines with galvanised insulator fittings ball and socket type and complete with strain clamps, bolt nut washers etc.as required.
Erection of pole top and straight two wire angle iron channel cross arm on steel tublor/Rail pole for 11KV as required
Supply and erection of Galvanised stay set for 11 KV OH line complete with 19/20 mm dia x 1.8 mtr long stay rod, anchor plate of size 45 cm x 45 cm x 7.5 mm thick, thimble, stay clamps ,turn buckle ( 20 mm x 600 mm ) 7/4.00 mm dia GI stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc as required.
Dismantling of over head lines comprising of aluminium over head conductor, G.I. wire, cross arms, insulators etc as required. Conductor = 2127.6 kg, Disc – 42 set x 5.5 kg = 231 kg, Pin – 48 set x 2.1 kg = 100.8 kg, G.I wire – 157.20 kg, Channel = 1.63 kg x 4 nos = 6.52 kg, 18.19 kg x 8 nos = 145.52 kg, Total = 2768.64 kg
Providing of 11 kV, 400 A Male contact Blade suitable for GOS
Providing of 11 kV, 400 A Female contact Blade suitable for GOS
Repairing of 400 Amps Gang Operating Switch.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared for maintenance. (3.8 km = 3800 mtr x 2 mtr = 7600 sqm )
Connection of 11 KV OH line jumper as required
Connection of 11 KV, 120 Sq mm 3 core armoured copper cable leads as required
Patrolling, checking, testing of 11 KV OH line for routine maintenance and breakdown as and when required for a route length of 5 KM
Earthing with copper earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required.
Supply and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanized clamping arrangement, GI bolts, nuts washers etc as required.
Erection of 8 SWG GI Wire including binding etc as required.
Total impact of GST for the purpose of CTC
M/S KUMAR ENTERPRISES (BID ID -1153515)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .