Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance PLOT NO 84 85 86 TINY INDUSTRIAL ESTATE KHADI MACHINE CHOWK KONDHAWA BR PUNE MAHARASHTRA 411048 | PUNE | MAHARASHTRA | 411048 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical A 103 NARESH SANGHVIKUSHAL SANGHVI 103 SKYLINE EPITOME BEHIND JOLLY GYMKHANA VIDHYAVIHAR W MUMBAI VIDHYAVIHAR | Rejected-Technical Technically not suitable |
| 4 | Rejected-Technical SHED NO 90A LICEL NANGARGAON LONAVLA PUNE MAHARASHTRA 410401 | PUNE | MAHARASHTRA | 410401 | Rejected-Technical Technically not suitable |
Tender Value
Refer Docs
Closing Date
3 Dec 2020, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SANDEEP SONAVALE
RCF THAL
SMART PRESSURE TRANSMITTER
2020_RCFL_597451_3
AL-66828 SMART PRESSURE TRANSMITTERS
Open Limited
Miscellaneous Goods
Supply
30 days
RCF THAL
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
Exempted
17 Apr 2021
26 Nov 2020
3 Dec 2020
26 Nov 2020
3 Dec 2020
26 Nov 2020
120 days
SUPPLY OF ITEMS AS PER FOLLOWING SPECIFICATIONS
SMART PRESSURE TRANSMITTER SPECIFICATIONS RANGE: 0 - 4 bar SERVICE: LIQ/GAS/VAPOUR TEMP. LIMITS: AMBIENT -20 to +60 DEGC, PROCESS -20 to + 100 DEGC ACCURACY: +/- 0.075% of FSD OUTPUT: 4-20 mA (2wire transmitter)/HART compatible POWER SUPPLY: 12 V to 30 V DC. ZERO/SPAN/MODE SETTING: Through HART communicator & Local push buttons DAMPING: Time constant adjustable 0.2 to 60 sec ZERO ELEV/SUPP: Can be fully elevated or suppressed within full range RESPONSE TIME: 300 ms LOCAL DISPLAY: digital LCD type RANGABILITY: 100:1 PROCESS CONNECTION: ½ NPT(F) SENSOR MATERIAL: 316L SST or Hastelloy C-276 or Tantalum BODY MATERIAL: SS 316 VENT PLUG: SS316 BODY ORINGS: EP-851 CABLE CONNECTION: ½ NPT (F) two sides MOUNTING: On 2 pipe MANIFOLD: 2 way manifold ENCLOSURE: Cast Aluminum Alloy HAZARDOUS AREA CLASSIFICATION: Intrinsically safe + explosion proof EEXia- CLASS IIC-T6 CERTIFICATION /APPROVAL: ATEX /UL/CSA DEGREE OF PROTECTION: IP 65
SMART PRESSURE TRANSMITTER SPECIFICATIONS RANGE: 0 - 15 bar SERVICE: LIQ/GAS/VAPOUR TEMP. LIMITS: AMBIENT -20 to +60 DEGC, PROCESS -20 to + 100 DEGC ACCURACY: +/- 0.075% of FSD OUTPUT: 4-20 mA ( 2wire transmitter)/HART compatible POWER SUPPLY: 12 V to 30 V DC. ZERO/SPAN/MODE SETTING: Through HART communicator & Local push buttons DAMPING: Time constant adjustable 0.2 to 60 sec ZERO ELEV/SUPP: Can be fully elevated or suppressed within full range RESPONSE TIME: 300 ms LOCAL DISPLAY: digital LCD type RANGABILITY: 100:1 PROCESS CONNECTION: ½# NPT(F) SENSOR MATERIAL: 316L SST or Hastelloy C-276 or Tantalum BODY MATERIAL: SS 316 VENT PLUG: SS316 BODY #O#RINGS: EP-851 CABLE CONNECTION: ½# NPT (F) two sides MOUNTING: On 2# pipe MANIFOLD: 2 way manifold ENCLOSURE: Cast Aluminum Alloy HAZARDOUS AREA CLASSIFICATION: Intrinsically safe + explosion proof EEXia- CLASS IIC-T6 CERTIFICATION /APPROVAL: ATEX /UL/CSA DEGREE OF PROTECTION: IP 65
SMART PRESSURE TRANSMITTER SPECIFICATIONS RANGE: 0 - 60 bar. SERVICE: LIQ/GAS/VAPOUR TEMP. LIMITS: AMBIENT -20 to +60 DEGC, PROCESS -20 to + 100 DEGC ACCURACY: +/- 0.075% of FSD OUTPUT: 4-20 mA ( 2wire transmitter)/HART compatible POWER SUPPLY: 12 V to 30 V DC. ZERO/SPAN/MODE SETTING: Through HART communicator & Local push buttons DAMPING: Time constant adjustable 0.2 to 60 sec ZERO ELEV/SUPP: Can be fully elevated or suppressed within full range RESPONSE TIME: 300 ms LOCAL DISPLAY: digital LCD type RANGABILITY: 100:1 PROCESS CONNECTION: ½# NPT(F) SENSOR MATERIAL: 316L SST or Hastelloy C-276 or Tantalum BODY MATERIAL: SS 316 VENT PLUG: SS316 BODY #O#RINGS: EP-851 CABLE CONNECTION: ½# NPT (F) two sides MOUNTING: On 2# pipe MANIFOLD: 2 way manifold ENCLOSURE: Cast Aluminum Alloy HAZARDOUS AREA CLASSIFICATION: Intrinsically safe + explosion proof EEXia- CLASS IIC-T6 CERTIFICATION /APPROVAL: ATEX /UL/CSA DEGREE OF PROTECTION: IP 65
SMART PRESSURE TRANSMITTER RANGE: 4 - 400 bar. SERVICE: LIQ/GAS/VAPOUR TEMP. LIMITS: AMBIENT -20 to +60 DEGC, PROCESS -20 to + 100 DEGC ACCURACY: +/- 0.075% of FSD OUTPUT: 4-20 mA ( 2wire transmitter)/HART compatible POWER SUPPLY: 12 V to 30 V DC. ZERO/SPAN/MODE SETTING: Through HART communicator & Local push buttons DAMPING: Time constant adjustable 0.2 to 60 sec ZERO ELEV/SUPP: Can be fully elevated or suppressed within full range RESPONSE TIME: 300 ms LOCAL DISPLAY: digital LCD type RANGABILITY: 100:1 PROCESS CONNECTION: ½# NPT(F) SENSOR MATERIAL: 316L SST or Hastelloy C-276 or Tantalum BODY MATERIAL: SS 316 VENT PLUG: SS316 BODY #O#RINGS: EP-851 CABLE CONNECTION: ½# NPT (F) two sides MOUNTING: On 2# pipe MANIFOLD: 2 way manifold ENCLOSURE: Cast Aluminum Alloy HAZARDOUS AREA CLASSIFICATION: Intrinsically safe + explosion proof EEXia- CLASS IIC-T6 CERTIFICATION /APPROVAL: ATEX /UL/CSA DEGREE OF PROTECTION: IP 65
SMART DP TRANSMITTERS FOR STATIC PRESSURE PN 420 AS PER SPECIFICATIONS 50 - 5000 M BAR PN420. RANGE 50 - 5000 M BAR PN420 STATIC PRESSURE: 420 BAR SERVICE: LIQ/GAS/VAPOUR TEMPERATURE LIMITS: AMBIENT -20 to +80 DEGC, PROCESS -20 to +100 DEGC ACCURACY: +/- 0.075% of FSD OUTPUT: 4-20mA ( 2wire transmitter)/HART compatible POWER SUPPLY: 12v to 30 v dc ZERO/SPAN/MODE SETTING: Through HART communicator & Local push buttons DAMPING: Time constant adjustable 0.2 to 60 sec ZERO ELEV/SUPP: Can be fully elevated or suppressed within full range RESPONSE TIME: 300 ms LOCAL DISPLAY: digital LCD type RANGABILITY: 100:1
SMART PRESSURE TRANSMITTER SPECIFICATIONS RANGE: 0 - 250 bar SERVICE: LIQ/GAS/VAPOUR TEMP. LIMITS: AMBIENT -20 to +60 DEGC, PROCESS -20 to + 100 DEGC ACCURACY: +/- 0.075% of FSD OUTPUT: 4-20 mA (2wire transmitter)/HART compatible POWER SUPPLY: 12 V to 30 V DC. ZERO/SPAN/MODE SETTING: Through HART communicator & Local push buttons DAMPING: Time constant adjustable 0.2 to 60 sec ZERO ELEV/SUPP: Can be fully elevated or suppressed within full range RESPONSE TIME: 300 ms LOCAL DISPLAY: digital LCD type RANGABILITY: 100:1 PROCESS CONNECTION: ½ NPT(F) SENSOR MATERIAL: 316L SST or Hastelloy C-276 or Tantalum BODY MATERIAL: SS 316 VENT PLUG: SS316 BODY ORINGS: EP-851 CABLE CONNECTION: ½ NPT (F) two sides MOUNTING: On 2 pipe MANIFOLD: 2 way manifold ENCLOSURE: Cast Aluminum Alloy HAZARDOUS AREA CLASSIFICATION: Intrinsically safe + explosion proof EEXia- CLASS IIC-T6 CERTIFICATION /APPROVAL: ATEX /UL/CSA DEGREE OF PROTECTION: IP 65
SMART DP TRANSMITTER SPECIFICATIONS RANGE: 0-250 MBAR STATIC PRESSURE: 420 BAR SERVICE: LIQ/GAS/VAPOUR TEMPERATURE LIMITS: AMBIENT -20 to +80 DEGC, PROCESS -20 to +100 DEGC ACCURACY: +/- 0.075% of FSD OUTPUT: 4-20mA ( 2wire transmitter)/HART compatible POWER SUPPLY: 12v to 30 v dc ZERO/SPAN/MODE SETTING:Through HART communicator & Local push buttons DAMPING: Time constant adjustable 0.2 to 60 sec ZERO ELEV/SUPP: Can be fully elevated or suppressed within full range RESPONSE TIME: 300 ms LOCAL DISPLAY: digital LCD type
SMART DP TRANSMITTER SPECIFICATIONS RANGE: 0-1600 MBAR STATIC PRESSURE: 420 BAR SERVICE: LIQ/GAS/VAPOUR TEMPERATURE LIMITS: AMBIENT -20 to +80 DEGC, PROCESS -20 to +100 DEGC ACCURACY: +/- 0.075% of FSD OUTPUT: 4-20mA ( 2wire transmitter)/HART compatible POWER SUPPLY: 12v to 30 v dc ZERO/SPAN/MODE SETTING:Through HART communicator & Local push buttons DAMPING: Time constant adjustable 0.2 to 60 sec ZERO ELEV/SUPP: Can be fully elevated or suppressed within full range RESPONSE TIME: 300 ms LOCAL DISPLAY: digital LCD type RANGABILITY: 100:1 PROCESS CONNECTION: 1/4# on flange & ½# NPT(F) on adaptor/manifold MANIFOLD: 3 way manifold SENSOR MATERIAL: 316L SST or Hastelloy C-276 or Tantalum BODY MATERIAL: SS 316 VENT PLUG: SS316 BODY #O#RINGS: EP-851 CABLE CONNECTION: ½# NPT (F) two sides MOUNTING: On 2# pipe ENCLOSURE: Cast Aluminum Alloy
SMART DP TRANSMITTERS FOR STATIC PRESSURE PN 420 AS PER SPECIFICATIONS RANGE: 0-30000 MBAR STATIC PRESSURE: 420 BAR SERVICE: LIQ/GAS/VAPOUR TEMPERATURE LIMITS: AMBIENT -20 to +80 DEGC, PROCESS -20 to +100 DEGC ACCURACY: +/- 0.075% of FSD OUTPUT: 4-20mA ( 2wire transmitter)/HART compatible POWER SUPPLY: 12v to 30 v dc ZERO/SPAN/MODE SETTING:Through HART communicator & Local push buttons DAMPING: Time constant adjustable 0.2 to 60 sec ZERO ELEV/SUPP: Can be fully elevated or suppressed within full range RESPONSE TIME: 300 ms LOCAL DISPLAY: digital LCD type RANGABILITY: 100:1 PROCESS CONNECTION: 1/4# on flange & ½# NPT(F) on adaptor/manifold SENSOR MATERIAL: 316L SST or Hastelloy C-276 or Tantalum BODY MATERIAL: SS 316 VENT PLUG: SS316 BODY #O#RINGS: EP-851 CABLE CONNECTION: ½# NPT (F) two sides MOUNTING: On 2# pipe ENCLOSURE: Cast Aluminum Alloy MANIFOLD: 3 way manifold HAZARDOUS AREA CLASSIFICATION: Intrinsically safe + explosion proof EEXia- CLASS IIC-T6 CERTIFICATION /APPROVAL: ATEX /UL/CSA DEGREE OF PROTECTION: IP 65
SMART DP TRANSMITTERS FOR STATIC PRESSURE PN 32 AS PER SPECIFICATIONS 1 - 20M BAR DP PN 32. RANGE: 1- 20M bar. SERVICE: LIQ/GAS/VAPOUR TEMP. LIMITS: AMBIENT -20 to +60 DEGC, PROCESS -20 to + 100 DEGC ACCURACY: +/- 0.075% of FSD OUTPUT: 4-20 mA ( 2wire transmitter)/HART compatible POWER SUPPLY: 12 V to 30 V DC. ZERO/SPAN/MODE SETTING: Through HART communicator & Local push buttons DAMPING: Time constant adjustable 0.2 to 60 sec ZERO ELEV/SUPP: Can be fully elevated or suppressed within full range RESPONSE TIME: 300 ms LOCAL DISPLAY: digital LCD type RANGABILITY: 100:1 PROCESS CONNECTION: ¼" on flange & ½" NPT(F) on adaptor/manifold. MANIFOLD: 3 way manifold SENSOR MATERIAL: 316L SST or Hastelloy C-276 or Tantalum BODY MATERIAL: SS 316 VENT PLUG: SS316 BODY ‘O’RINGS: EP-851 CABLE CONNECTION: ½" NPT (F) two sides MOUNTING: On 2" pipe ENCLOSURE: Cast Aluminum Alloy HAZARDOUS AREA CLASSIFICATION: Intrinsically safe + explosion proof EExia- CLASS IIC-T6 CERTIFICATION /APPROVAL: ATEX /UL/CSA DEGREE OF PROTECTION: IP 65
SUPREME TECHNOLOGY
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .