Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAccepted-AOC GIDDERBAHA PUNJAB | ₹1.9 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹2.0 Cr+₹10.0 L (5.29%)Rejected-AOC | ₹2.0 Cr+₹10.0 L (5.29%) | L2 | Rejected-AOC Being Highest |
Tender Value
₹1.9 Cr
EMD Value
₹3.8 L
Closing Date
6 Oct 2022, 10:00 amClosed
Gaurav
Divisional Engineer, Twell Const Division, PWRMDC Ltd, SYL Shed No.02, Near Nehru Stadium , Ropar.
LAYING OF UNDER GROUND PVC PIPE LINE AND ENERGISATION OF 06 NO. DEEP TUBWELLS IN BALACHAUR AND SAROYA BLOCK IN DISTRICT SBS NAGAR(UNDER 502 NO. NEW DEEP TUBEWELL PROJECT) PART-B
2022_WR_90178_1
24/2022/TCD/ROPAR
Open Tender
Miscellaneous Works
Item Rate
150 days
Saroya and Balachaur Block of Distt SBS Nagar
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
Yes
₹3.8 L
Yes
Ropar
11 Jan 2023
15 Sept 2022
6 Oct 2022
16 Sept 2022
6 Oct 2022
16 Sept 2022
23 Sept 2022
Amount
Laying of PVC Underground Pipe Line Energisation of T/Wells village Malewal,Pojewal-36,Mangupur, Mahipur ,Rajumajra & Rattewal-04 of Block Balachaur & Saroya
Laying of PVC Underground Pipe Line 160 mm dia of 1 No. T/Well Block Balachaur or Saroya
Dag Belling double kassi stroke V-Shape minimum 10 cm depth.
Exacavation by mechanical means (JCB or Hydrulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming. Earth work excavation trimming and dressing of sides, leveling of beds of trenches to correct grade, cutting joint holes, refilling, consolidation, watering, including the cost of dewatering of rain water,Diversion for traffic, nightsignals. Providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing etc.and removal of surplus soil outside/inside the town involving lead upto 15mtr. complete in all respect. In all classes of soil except rocky.
Providing, Laying, fixing and jointing of PVC Pipes as per ISI 4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specification . 160 mm o/d pipe of 2.5 kgf./sqcm
Suppling, carriage and fixing PVC Bend size 160 mm Ф,4 kgf/sqcm, 1.5 mtr length of 90 degree
Suppling, carriage and fixing PVC Bend size 160 mm Ф, 4 kgf/sqcm, 1.5 mtr length of 45 degree
Suppling, carriage and fixing PVC Bend size 160 mm Ф, 4 kgf/sqcm, 1.5 mtr length of 30 degree
Suppling, carriage & fixing equal PVC Tee pressure 4 kgf/Cm², 160x160x160mm
Cost of One No. Riser (PVC pipe of 2.5 kgf/sqcm pressure and fitting of 4 kgf/sqcm) of 160mm dia as per approved drawing & Design unit each
Providing and Making outlet Khura (PVC pipe of 2.5 kgf/sqcm pressure and fitting of 4 kgf/sqcm) at riser point complete in all respect as per approved design/drawing 160 mm dia.
Providing and fixing Pressure air release pipe 160mm dia. (PVC pipe of 2.5 kgf/sqcm pressure and fitting of 4 kgf/sqcm) as per approved design/drawing.
Suppling & carriage of RCC spun pipe with rubber ring as per I.S:458-2003( pipe for road crossing)Class N.P.2. 250mm dia.
Suppling, carriage and fixing PVC coupler 160mm i/d ,4.0 kgf/cm²
Suppling, carriage and fixing PVC end cap 160mm I/D, 4.0 kgf/cm²
Const. of pipe stand with RCC 600 mm dia pipe complete in all respect as per drawing/design and PWD specification .
Making Grade Breaker as per design/drawing (PVC pipe of 2.5 kgf/sqcm pressure and fitting of 4 kgf/sqcm)and PWD specification( including the cost of Material, carriage & re-carriage at site of work).
Providing & fixing C.I/D.I flanged end , stem of SS (AIS 1410) & Bronze ( gunmetal) working parts sluice valves ISI maked 14846-2000 , including jointing. Testing & cost of Nut, bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge) .Class PN-1 as per ISI 150mm i/d Sluice Valves flanged and Const. of masonary sluice valve chamber excluding sluice valve cover as per Standard Design & Drawing of Public Health Dept. Size 0.9m x 0.9m.
Laying of PVC Underground Pipe Line 200 mm dia of 5 No. T/Well Block Balachaur or Saroya
Dag Belling double kassi stroke V-Shape minimum 10 cm depth.
Exacavation by mechanical means (JCB or Hydrulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming. Earth work excavation trimming and dressing of sides, leveling of beds of trenches to correct grade, cutting joint holes, refilling, consolidation, watering, including the cost of dewatering of rain water,Diversion for traffic, nightsignals. Providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing etc.and removal of surplus soil outside/inside the town involving lead upto 15mtr. complete in all respect. In all classes of soil except rocky.
Providing, Laying, fixing and jointing of PVC Pipes as per ISI 4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specification . 200 mm o/d pipe of 2.5 kgf./sqcm
Suppling, carriage and fixing PVC Bend size 200 mm Ф,4 kgf/sqcm, 1.5 mtr length of 90 degree
Suppling, carriage and fixing PVC Bend size 200 mm Ф, 4 kgf/sqcm, 1.5 mtr length of 45 degree
Suppling, carriage and fixing PVC Bend size 200 mm Ф, 4 kgf/sqcm, 1.5 mtr length of 30 degree
Suppling, carriage & fixing equal PVC Tee pressure 4 kgf/Cm², 200x200x200mm
Cost of One No. Riser (PVC pipe of 2.5 kgf/sqcm pressure and fitting of 4 kgf/sqcm) of 200mm dia as per approved drawing & Design unit each
Providing and Making outlet Khura (PVC pipe of 2.5 kgf/sqcm pressure and fitting of 4 kgf/sqcm) at riser point complete in all respect as per approved design/drawing 200 mm dia.
Providing and fixing Pressure air release pipe 200mm dia. (PVC pipe of 2.5 kgf/sqcm pressure and fitting of 4 kgf/sqcm) as per approved design/drawing.
Suppling & carriage of RCC spun pipe with rubber ring as per I.S:458-2003( pipe for road crossing)Class N.P.2. 250mm dia.
Suppling, carriage and fixing PVC coupler 200mm i/d ,4.0 kgf/cm²
Suppling, carriage and fixing PVC end cap 200mm I/D, 4.0 kgf/cm²
Const. of pipe stand with RCC 600 mm dia pipe complete in all respect as per drawing/design and PWD specification .
Making Grade Breaker as per design/drawing (PVC pipe of 2.5 kgf/sqcm pressure and fitting of 4 kgf/sqcm)and PWD specification( including the cost of Material, carriage & re-carriage at site of work).
Providing & fixing C.I/D.I flanged end , stem of SS (AIS 1410) & Bronze ( gunmetal) working parts sluice valves ISI maked 14846-2000 , including jointing. Testing & cost of Nut, bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge) .Class PN-1 as per ISI 200mm i/d Sluice Valves flanged and Const. of masonary sluice valve chamber excluding sluice valve cover as per Standard Design & Drawing of Public Health Dept. Size 0.9m x 0.9m.
Energisation of 6 NO. T/wells
Submersible pumping set of 55 H.P. 115 Mtr Head ISI Marked
Submersible pumping set of 65 H.P. 125 Mtr Head ISI Marked
Submersible pumping set of 75 H.P. 140 Mtr Head ISI Marked
Submersible pumping set of 80 H.P. 150 Mtr Head ISI Marked
Submersible pumping set of 90 H.P. 160 Mtr Head ISI Marked
Three Core Submersible Flat Cable 16 sqmm. ISI Marked
Three Core Submersible Flat Cable 25 sqmm. ISI Marked
Control panel complete 55 H.P.
Control panel complete 65 H.P.
Control panel complete 75 H.P.
Control panel complete 80 H.P.
Control panel complete 90 H.P.
MS pipe(heavy) (IS:1239/3589/4270), 100 mm i/d 5.40 mm thick.
Suppling and Fixing M.S. flange 4 “ dia , 5/8” thick , outer dia. 190 mm with 4 no. holes and 2 no. cuts
M.S. nut & bolt of all sorts
M.S. Lead clamp of 100 mm dia size 3mmx20mm
M.S flat for jal
PVC insulator 3.5 core cable for connection from transformer to Control Panel
Supplying and fixing of well cap to fix on housing pipe complete in all respect -300 mm internal diameter
M.S. bend 4”,90 Degree , 5 mm thickness, leg length 40 cm ,flange thickness 15 mm , 6 no. holes
Providing & fixing C.I/D.I flanged end , stem of SS (AIS 1410) & Bronze ( gunmetal) working parts sluice valves ISI maked 14846-2000 , including jointing, Testing & cost of Nut, bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge) .Class PN-1 as per ISI 100 mm i/d Sluice Valves flanged.
PVC copper wire 19/16 ISI marked
PVC copper wire 7/22 ISI marked
T/well provision soldier thimble, flexible pipe , copper earth plate, G.I. pipe 1" dia, G.I. wire, internal electrification & Double earthing (with cost of material & labour)
Labour for lowering of pumping set
MS Clamp 4" dia from 13mm thick MS Sheet
MATERIAL AND LABOUR TO BE PROVIDED FOR TAKING OUT DELIVERY PIPE STAND
Supply of M.S. pipe (heavy)(IS:1239/3589/4270) 100 mm i/d 5.40mm thick
M.S. plain Bend 4” dia 5.40 mm thick.
M.S. flange 4” dia. For sluice valve
Providing & fixing C.I/D.I flanged end , stem of SS (AIS 1410) & Bronze ( gunmetal) working parts sluice valves ISI maked 14846-2000 , including jointing. Testing & cost of Nut, bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge) .Class PN-1 as per ISI 100mm i/d Sluice Valves flanged
Welding of MS Pipe for connecting to the delivery pipe.
SUKHBIR SINGH CONTRACTOR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .