| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹42.9 L+₹3.0 L (7.60%)Rejected-AOC | L2 | Rejected-AOC Not Being L1 | |
| 3 | L3₹43.9 L+₹4.0 L (10.1%)Rejected-AOC 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-AOC Not Being L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
18 Dec 2023, 6:00 pmClosed
Garrison Engineer(N) Mamun
Garrison Engineer(N) Mamun Pin-145001
REPAIR/ MAINTENANCE OF ELECTRICAL E/M INSTALLATION, DG SETS, SECURITY LIGHTS AND OTHER CONNECTED WORKS AT D-IA ZONE AND D-IB ZONE UNDER AGE E/M-I OF GE (N) MAMUN
2023_MES_629302_1
GE(N)/M-58/2023-24
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer(N) Mamun
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer(N) Mamun
₹80,000
5 Feb 2024
22 Nov 2023
20 Dec 2023
22 Nov 2023
18 Dec 2023
5 Dec 2023
Amount
Repair/maint of unserviceable street light/flood light fitting of any type/watt mounted on poles/walls/high mast and making serviceable by re-connecting electric wires from OH conductor / junction box complete all as specified and directed . Notes : 1. Any component found unserviceable that shall be replaced & paid under respective items of this Sch. 2. Contractor or his rep should collect the complaint slips from power house as directed . 3. Complaints of street/flood lights shall be done within two days after receipt of complaint and complaint slip shall be deposited after repair work.
Disconnecting, dismantling and taking down carefully unserviceable security/flood light/gate light any type/watt alongwith all connected accessories from pole or wall or high mast for repair, and deposited to MES store yard for reuse or for taking credit to contractor all as specified and directed .
Fixing only serviceable security/flood light/gate light any type/watt (retrieved from srl No 2 above) including and after minor repair if any, checking all wiring and serviceability of all components alongwith all connected accessories all as specified and directed .
S&F in replacement LED street light fitting, 45 watts, 240 volts, Pressure die-cast aluminium alloy for housing, LED module with SMD LED package mounted on MCPCB. voltage operating range 140 V - 270 V. Lumen efficacy of LED >140 lm/W with lens,. LED street lights with efficacy >110 lm/W, suitable for pole mounting with bracket arm >50 mm ID. polycarbonate UV stablized cover with integrated Lens, built-in potted LED driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit protection, Phase to Phase protection (Operation at 415 V AC), PF >.9, Over Voltage protection, Surge Voltage protection upto 10 kV with SPD, conforming to IP - 66, top opening complete all as specified and directed .
All as mentioned in item No 04 but 60 watts suitable with pole mounting bracket arm OD >54 mm
All as mentioned in item No 04 but 90 watts, tempered protective toughned glass with suitable pole mounting with bracket arm OD >58 mm
S&F in replacement LED flood light fitting, 100 watts, 240 volts, powder coated die-cast aluminium housing, LED module with SMD LED package mounted on MCPCB. Operating voltage range: 140 V - 270 V, System efficacy of LED >110 lLPW, provided with wall or surface mounting using adjustable MS cradle with SS angular mounting arrangement, PC Lens with toughened glass, integral electronic potted LED driver with APFC,lower THD, Open / short circuit Protection, Phase to Phase protection (Operation at 415 V AC), Over Voltage Protection, Surge Voltage Protection upto 10kV with built In SPD, conforming to IP-66, glass diffuser, Average life L70B50: 50000 hours complete all as specified and directed.
All as mentioned item No 07 but 150 watts ,
All as mentioned item No 07 but 200 watts
Taking down street light junction box from steel/ PCC pole including shifting to MES store yard for further disposal action all as specified and as directed.
S&F in replacement of weatherproof junction box of size 300x200x105 mm outdoor type made out of thermo polycarbonate to accommodate 04 Nos aluminium bus bar of size 25x6 mm and MCB SP 6 Amps IP-65 with hinged door and triangular locks shocked proof, rust proof, corrosion free, acid resistance/fire retardant and self-extinguishing UV resistance complete incl fixing arrangement i.e clampsof size 25x4mm with nut and bolt and washers fixed on steel/PCC pole all as specified and as directed.
Taking down street light mounting bracket from steel/ PCC pole including shifting to MES store yard for further disposal action all as specified and directed.
Supply and fixing in replacement street light mounting bracket ,fabricated, bend to shape, made out of GI pipe, light grade, 32 mm bore dia,120 cm long for mounting on PCC/Steel poles incl 02 X MS clamps with suitable length MS strips of 25x5mm with nut, bolt, washers and painting with two coats of aluminium paint over a coat of red oxide complete all as specified and directed .
Taking down old U/S street light connection wire from pole including shifting to MES store yard for further disposal action .
M&L in replacement PVC insulated, FR PVC round sheathed, stranded Copper flexible conductor industrial cable,1100 volts grade, confirming to IS 694, 3 core, 1.5 sqmm for connecting light fitting with junction box drawn through pole or GI pipe all as specified and as directed.
M&L in replacement PVC insulated, stranded Aluminium flexible conductor industrial cable,1100 volts grade, confirming to IS-694, single core, 4.0 sqmm for connecting street light fitting with over head conductor all as specified and as directed . Note : GI pipe and MS clamps shall be measured and seperately under relevant item
Dismantling old unserviceable pole/Strut any size, any type and shifting n.exceeding 50 meters, setting aside for disposal action all as specified and directed .
Supply, erection and installation of steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 metres long) duly painted with two coat of black bituminous paint through out, internally and externally up to planning depth and painting remaining portion of pole with two coat of aluminium paint to the entire exposed surfaces over one coat of red oxide primer making/painting three Nos circular strips each of 30 cm wide with one yellow and 02 Nos black colour strip synthetic enamel paint and marking pole number with black paint all as specified and directed . (Note : Excavation, earth work, PCC work shall be measured and paid separately under respective items)
Supply, erection and installation of steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 metres long) duly painted with two coat of black bituminous paint through out, internally and externally up to planning depth and painting remaining portion of pole with two coat of aluminium paint to the entire exposed surfaces over one coat of red oxide primer making/painting three Nos circular strips each of 30 cm wide with one yellow and 02 Nos black colour strip synthetic enamel paint and marking pole number with black paint all as specified and directed. (Note : Excavation, earth work, PCC work shall be measured and paid separately under respective items)
Dismantling cross-arms of M.S. channel or angle sections etc from LT poles complete and setting aside for re-use or shifting to MES store for taking credit to contractor all as specified and directed.
Material and labour for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed.
Fixing only the cross arms items with supports/ angle iron frame etc incl nut, bolt, washer, welding, bending, hot or cold drilling holes for insulators bolts in any size or shape complete all as specified as directed.
Taking out cable LT 1100 volts grade, heavy duty aluminium conductor upto 10-16 Sqmm, any core from trenches,wall pole or pipe for rectification of faults or replacement including seggregating serviceable/un-serviceable cable and stacking aside for reuse or removing to MES store for disposal action. Note:Earth shall be measured and paid separately under respective item.
All as per Srl Item 23 here in above but of size 25 Sqmm
All as per item No 23 but for LT cable 35 to 70 Sqmm 3.5 core.
All as per item No 23 but for LT cable 95 to 150 Sqmm 3.5 core.
Laying, connecting and testing serviceable cable 10-16 sqmm retrieved from item No 23 including providing cable lugs on termination all as specified and as directed.
All as mentioned in item No 27 here in above but 25 sqmm cable retrieved from item No 24
All as per item No 27 but of LT cable 35 to 70 Sqmm 3.5 core retrieved from item No 25
All as per item No 27 but of LT cable 95 to 150 Sqmm 3.5 core retrieved from item No 26 above
Supply and laying in trenches or fixing to wall/pole or passing through pipe PVC insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 10 Sqmm 2 core all as specified and as directed. (Note : Incl making good all distributed wall surfaces/ flooring/tilling/road to match with existing specification)
All as per item No 31 but cable of size 10 Sqmm 4 core.
All as per item No 31 but cable of size 16 Sqmm 4 core.
All as per item No 31 but cable of size 25 Sqmm 4.0 core.
All as per item No 31 but cable of size 25 Sqmm 3.5 core.
All as per item No 31 but cable of size 35 Sqmm 3.5 core.
All as per item No 31but cable of size 50 Sqmm 3.5 core.
All as per item No 31 but cable of size 95 Sqmm 3.5 core.
All as per item No 31 but cable of size 150 Sqmm 3.5 core.
All as per item No 31 but cable of size 16 Sqmm 2 core.
Taking out old unserviceable GI tubing of 15/40/50/80 mm bore dia including shifting to MES store for disposal action.
Supply and fixing in replacement of GI tubing, light grade 80 mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed. Note :clamps for fixing pipe, nuts, bolts washers shall be measured separately
All as mentioned in item No 42 here in above but 50 mm bore
All as mentioned in item No 42 here in above but 40 mm bore
All as mentioned in item No 42 here in above but 15 mm bore
M&L for Cable end termination jointing kit, heat shrinkable, 1100 volts grade complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 25 sqmm to 50 sqmm, 2/3.5 core all as specified and directed .
Al as mentioned in item No 46 here in above but for 6 to 16 sqmm, 2 to 4 core
All as per item No 46 but for cable of size 70 to 150 Sqmm 3.5 core.
All as per item No 46 but for cable of size 185 to 300 Sqmm 3.5 core.
Cable jointing kit for 1100 volt grade cable for straight through termination heat shrinkable type complete with jointing material and accessories suitable for XLPE/PVC armoured aluminium conductor cable of size 25 to 50 Sqmm 2/3.5 core all as specified and as directed .
All as per item No 50 but for cable of size 70 to 150 Sqmm 3.5 core.
All as per item No 50 but for cable of size 185 to 300 Sqmm 3.5 core.
All as per item No 50 but for cable of size 6 to16 Sqmm 2/4 core.
Taking out old unserviceable MCCB of any type and capacity including shifting to MES store for disposal action.
S&F in replacement MCCB 4 pole 415 volts fixed type 25-100 Amps with braking capacity16 KA, thermal release adjustable from 80 to 100% & fixed magnetic release with Ics = 100% Icu , including spreaders after taking out old U/S one all as specified and directed .
S&F in replacement MCCB, 4 pole 415 volts fixed type 160 Amps with braking capacity16 KA, thermal release adjustable from 80 to 100% & fixed magnetic release with Ics = 100% Icu , including spreaders after taking out old U/S one all as specified and directed .
M&L for painting of steel tubular pole up to 11 mtr long incl cross arms without removing accessories after preparation of surfaces (duly scratching old paint), the pole shall be painted (above coping) with 5 Nos circular strips each of 30 cm (of colour combination as directed by Engr-In-Charge) with synthetic enamel paint duly marked pole number in a 12 cm dia yellow circle with number writing with black synthetic paint. The remaining pole shall be painted with two coats of aluminium paint and painting of cross arms with one coat of aluminium paint including one coat of snowcem on PCC coping of pole complete all as specified and directed.
All as mentioned in item No 57 here in above but pole 09 metre long
M&L for painting of PCC pole 9/11 mtr long including cross arms without removing accessories after preparation of surfaces, the pole shall be painted (above coping) with 5 Nos strips each of 30 cm (of colour combination as directed by Engr-In-Charge) with synthetic enamel paint duly marked pole number in a 12 cm dia yellow circle with number writing with black synthetic paint. Colour washing the remaning pole and coping by using snowcem of approved colour including painting of cross arms by applying one coat of alumn paint all as required at site complete all as specified and directed.
Excavating in trenches in soft / loose soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation of poles, trenches for laying of cable, or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
All as mentioned in item No 60 here in above but n exc 1.5 m wide and exc 1.5 m and n exceeding 3.0 m in depth
Removing excavated material to a distance not exceeding 50 Mtr and deposting where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and directed .
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each all as required and directed.
Supply of brick sub class 'B' laid dry in trenches over the cable adjoining each other widthwise for cable protection complete all as specified and as directed.
Relaying of brick sub class 'B' laid dry in trenches over the cable adjoining each other widthwise for cable protection complete all as specified and as directed .
M&L for sand cushioning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches complete all as specified and directed . Note: Punned thickness i.e 180mm shall be measured and paid.
Material and Labour for PCC 1:4:8 type D-2 using 40 mm graded stone aggregrate for foundation filling as mass concrete including necessary form work complete all as specified and as directed .
Material and Labour for PCC 1:3:6 type C-1 using 20 mm graded stone aggregrate for coping of poles and foundation of stay complete all as specified and as directed .
S&F in replacement of fully retroreflective sign boards of cut to sizes/shape having writing back ground made out of 18 SWG MS Sheet duly painted with two coats of synthetic enamel paint over a coat of primer including marking/writing letters, road sign any type with radium tape in different colours, duly mounted on steel rod 40 mm dia fancy type fixed with nut, bolt, washer and welding (height of rods as per site requirement) etc including all necessary earth work and PCC for foundation all as specified and directed.
M & L for marking/writing feeder names/ SM No / MES No for HT/LT Electrical Eqpts like VCB, Tfrs, RMU, panels etc with synthetic enamel paint or water proof stickers complete all as specified and directed .
S&F in replacement of line diagram of electric supply, fabricated of 3mm thick acrylic cover fibre board any weather proof incl printing/writing figure (letter/number) all as directed by Engr-In-Charge and providing with 6mm thick plywood support by aluminium beading complete and fixing on wall of any type with rawal plug and screws etc all as specified and directed.
S&F first aid kit box including all necessary items of first aid all as specified and directed .
S&F in replacement of notice board made out of plywood board with fixing of cloth of best quality green colour supported by aluminium beading complete of size 1.2 mtr x 1.2 mtr fixing on wall with necessary arrangement inclunding one box of cap pins all as specified and directed .
Disconnecting, dismantling aluminium conductor from LT/HT overhead lines after unbinding from insulators and deposited to MES store yard or taking credit to contractor all as specified .
M&L in replacement ACSR of LT OH line including securing with insulators using aluminium binding wire, jointing jumpers etc including all disconnected cables, jumpers with proper binding complete all as specified and as directed .
Unbinding from insulators ACSR conductor any size of LT/HT over head line for repairs. Re-stretching of ACSR conductor to achieve proper sag and rebinding to the insulators using new alumn/GI binding wire after repair and making all existing cable connections all as required at site. (Note: The length of all conductors (incl phases and neutral) should be considered as per RM)
Dismantling GI earth wire from LT/HT OH line after unbinding from pole for re-use or for shifting to MES store for taking credit to contractor all as specified .
M&L for Galvanised steel earth wire of service feeder or distributor span of street light polesincluding binding with insulators using GI binding wire, jointing jumpers etc including connections of incoming and out going cables complete all as specified .
Unbinding from insulators GI earth wire of any size of LT/HT overhead lines, Restretching the GI earth wire to achieve proper sag and rebinding to the insulators using new alumn/GI binding wire after repair.
Dismantling and taking old/UNSV stay assembly including Stay wire and insulator complete all as specified .
M&L for replacement stay assembly complete with MS stay plate of size 300x300x6mm thick, stay rod 20 mm dia, stay bow, nuts, bolts and check nuts of GI all as shown in EP No 01 of SSR Part-I, 2009 ( Excavation, PCC, saty wire and loop type insulators will be measured separately) complete all as specified and as directed.
M&L in replacmement galvanized stay strand of 7/4mm size complete all as specified and directed .
M&L in replacemement loop type insulator large size with overall dimensions (90 x140) mm with clearance of hole 25.5 mm vitreous white brown or green complete all as specified and as directed.
Dismantling insulators of any type, any size from LT overhead lines complete all as specified and as directed.
Fixing only insulators any type/size in LT overhead lines (retrived from item No 40 above) all as specified and directed .
M&L shackle type insulator,100 mm height,115 mm dia, 31x5 mm strap,14 mm dia bolts Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, as under: complete all as specified and as directed.
M&L Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade complete all as specified and as directed.
Disconnecting electrically, dismantling from foundation with due care and setting aside LT feeder pillar box any type any size with all accessories.
Supply,Installing,testing and commissioning factory made and tested, CPRI approved and test certified LT feeder pillar box (KIOSK) outdoor type, floor mounted,3 phase 4 wire, 50 Hz AC supply, system having sleeve insulated Aluminium busbar rating 1.5 times of main incomer switch gear but not less than 200 Amps , dust and vermin proof, powder coated in 8 tank process , confirms to IP - 65 class protection, both side openable door, compartamentalised for each MCCB and max 02 Nos MCB, approns for cable entry with double door shutter and locking arrangement ,made out of 3.15 mm thick CRCA sheet, cable entry plates provided with cable glands, 50x50x 6 mm angle iron frame with 70 cm leg for mounting panel , Internal wiring with PVC insulated but sheathed, stranded copper conductor FRLS (IS-694) marked,1100 volts grade of adequate but not less than 4.0 sq mm size , PCC foundation of suitable size all as specified and directed. with comprising following components. Location : Shivalik infront Mandir for Main TCP (i) MCCB 160 Amps, 415 volts, 50 Hz, 4 pole, 25 KA, thermal adjustable – 0.8 to 1In, fixed magnetic at 10In- 01 No (ii) MCCB 125 Amps, 415 volts, 50 Hz, 4 pole, 16 KA, thermal adjustable – 0.8 to 1In, fixed magnetic at 10In- 01 No (iii) MCCB 63 Amps, 415 volts, 50 Hz, 4 pole, 16 KA, thermal adjustable – 0.8 to 1In, fixed magnetic at 10In- 01 No(iv) MCB TPN 63 Amps, "C" curve,415 volts, 50 Hz - 01 No (v) MCB SPN 40 Amps, "C" curve,415 volts, 50 Hz - 03 Nos (vi) Digital Ammeter 3 phase -01 No(vii) Digital Volt meter 3 phase ,415 volts AC -01 No (viii) LED pilot lamps- 01 set (RYB)
Supply,Installing,testing and commissioning factory made and tested, CPRI approved and test certified LT feeder pillar box (KIOSK) outdoor type, floor mounted,3 phase 4 wire, 50 Hz AC supply, system having sleeve insulated Aluminium busbar rating 1.5 times of main incomer switch gear but not less than 200 Amps , dust and vermin proof, powder coated in 8 tank process , confirms to IP - 65 class protection, both side openable door, compartamentalised for each MCCB and max 02 Nos MCB, approns for cable entry with double door shutter and locking arrangement ,made out of 3.15 mm thick CRCA sheet, cable entry plates provided with cable glands, 50x50x 6 mm angle iron frame with 70 cm leg for mounting panel , Internal wiring with PVC insulated but sheathed, stranded copper conductor FRLS (IS-694) marked,1100 volts grade of adequate but not less than 4.0 sq mm size , PCC foundation of suitable size all as specified and directed. with comprising following components. Location : Ashok Kunj ( Near Main TCP) (i) MCB TPN 40 Amps, "C" curve,415 volts, 50 Hz - 01 Nos (ii) MCB SPN 40 Amps, "C" curve,415 volts, 50 Hz - 01 Nos (iii) MCB SP 06 Amps, "C" curve,415 volts, 50 Hz - 05 Nos (iv) Digital Ammeter 3 phase -01 No (v) Digital Volt meter 3 phase ,415 volts AC -01 No (vi) LED pilot lamps- 01 set (RYB)
Supply,Installing,testing and commissioning factory made and tested, CPRI approved and test certified LT feeder pillar box (KIOSK) outdoor type, floor mounted,3 phase 4 wire, 50 Hz AC supply, system having sleeve insulated Aluminium busbar rating 1.5 times of main incomer switch gear but not less than 200 Amps , dust and vermin proof, powder coated in 8 tank process , confirms to IP - 65 class protection, both side openable door, compartamentalised for each MCCB and max 02 Nos MCB, approns for cable entry with double door shutter and locking arrangement ,made out of 3.15 mm thick CRCA sheet, cable entry plates provided with cable glands, 50x50x 6 mm angle iron frame with 70 cm leg for mounting panel , Internal wiring with PVC insulated but sheathed, stranded copper conductor FRLS (IS-694) marked,1100 volts grade of adequate but not less than 4.0 sq mm size , PCC foundation of suitable size all as specified and directed. with comprising following components. Location : Shivalik Enclave MAP main panel (i) MCCB 400 Amps, 415 volts, 50 Hz, 4 pole, 36 KA, thermal adjustable – 0.8 to 1In, adjustable magnetic 5-10In- 01 No (ii) MCCB 250 Amps, 415 volts, 50 Hz, 4 pole, 25 KA, thermal adjustable – 0.8 to 1In, adjustable magnetic 5-10In- 01 No (iii) MCCB 160 Amps, 415 volts, 50 Hz, 4 pole, 16 KA, thermal adjustable – 0.8 to 1In, fixed magnetic at 10In- 03 Nos (iv) MCCB 125 Amps, 415 volts, 50 Hz, 4 pole, 16 KA, thermal adjustable – 0.8 to 1In, fixed magnetic at 10In- 02 Nos (v) MCB TPN 40 Amps, "C" curve,415 volts, 50 Hz - 01 Nos (vi) MCB SPN 32 Amps, "C" curve,415 volts, 50 Hz - 02 Nos (vii) Digital Ammeter 3 phase -01 No (viii) Digital Volt meter 3 phase ,415 volts AC -01 No (ix) LED pilot lamps- 01 set (RYB)
Supply,Installing,testing and commissioning factory made and tested, CPRI approved and test certified LT feeder pillar box (KIOSK) outdoor type, floor mounted,3 phase 4 wire, 50 Hz AC supply, system having sleeve insulated Aluminium busbar rating 1.5 times of main incomer switch gear but not less than 200 Amps , dust and vermin proof, powder coated in 8 tank process , confirms to IP - 65 class protection, both side openable door, compartamentalised for each MCCB and max 02 Nos MCB, approns for cable entry with double door shutter and locking arrangement ,made out of 3.15 mm thick CRCA sheet, cable entry plates provided with cable glands, 50x50x 6 mm angle iron frame with 70 cm leg for mounting panel , Internal wiring with PVC insulated but sheathed, stranded copper conductor FRLS (IS-694) marked,1100 volts grade of adequate but not less than 4.0 sq mm size , PCC foundation of suitable size all as specified and directed. with comprising following components. Location : Shivalik Enclave (B1,B2,P15 & P17) (i) MCCB 160 Amps, 415 volts, 50 Hz, 4 pole, 25 KA, thermal adjustable – 0.8 to 1In, fixed magnetic at 10In- 01 No (ii) MCCB 100 Amps, 415 volts, 50 Hz, 4 pole, 16 KA, thermal adjustable – 0.8 to 1In, fixed magnetic at 10In- 05 Nos (iii) MCB TPN 40 Amps, "C" curve,415 volts, 50 Hz - 01 Nos (iv) MCB SPN 32 Amps, "C" curve,415 volts, 50 Hz - 02 Nos (v) Digital Ammeter 3 phase -01 No (vi) Digital Volt meter 3 phase ,415 volts AC -01 No (vii) LED pilot lamps- 01 set (RYB)
Supply,Installing,testing and commissioning factory made and tested, CPRI approved and test certified LT feeder pillar box (KIOSK) outdoor type, floor mounted,3 phase 4 wire, 50 Hz AC supply, system having sleeve insulated Aluminium busbar rating 1.5 times of main incomer switch gear but not less than 200 Amps , dust and vermin proof, powder coated in 8 tank process , confirms to IP - 65 class protection, both side openable door, compartamentalised for each MCCB and max 02 Nos MCB, approns for cable entry with double door shutter and locking arrangement ,made out of 3.15 mm thick CRCA sheet, cable entry plates provided with cable glands, 50x50x 6 mm angle iron frame with 70 cm leg for mounting panel , Internal wiring with PVC insulated but sheathed, stranded copper conductor FRLS (IS-694) marked,1100 volts grade of adequate but not less than 4.0 sq mm size , PCC foundation of suitable size all as specified and directed. with comprising following components. Location : GAPS-1 (i) MCCB 125 Amps, 415 volts, 50 Hz, 4 pole, 16 KA, thermal adjustable – 0.8 to 1In, fixed magnetic at 10In- 01 Nos (ii) MCCB 100 Amps, 415 volts, 50 Hz, 4 pole, 16 KA, thermal adjustable – 0.8 to 1In, fixed magnetic at 10In- 01 No (iii) MCCB 63 Amps, 415 volts, 50 Hz, 4 pole, 16 KA, thermal adjustable – 0.8 to 1In, fixed magnetic at 10In- 02 Nos (iv) MCB TPN 40 Amps, "C" curve,415 volts, 50 Hz - 02 Nos (v) MCB SPN 63 Amps, "C" curve,415 volts, 50 Hz - 02 Nos (vi) MCB SPN 40 Amps, "C" curve,415 volts, 50 Hz - 02 Nos (vii) Digital Ammeter 3 phase -01 No (viii) Digital Volt meter 3 phase ,415 volts AC -01 No (ix) LED pilot lamps- 01 set (RYB)
Supply,Installing,testing and commissioning factory made and tested, CPRI approved and test certified LT feeder pillar box (KIOSK) outdoor type, floor mounted,3 phase 4 wire, 50 Hz AC supply, system having sleeve insulated Aluminium busbar rating 1.5 times of main incomer switch gear but not less than 200 Amps , dust and vermin proof, powder coated in 8 tank process , confirms to IP - 65 class protection, both side openable door, compartamentalised for each MCCB and max 02 Nos MCB, approns for cable entry with double door shutter and locking arrangement ,made out of 3.15 mm thick CRCA sheet, cable entry plates provided with cable glands, 50x50x 6 mm angle iron frame with 70 cm leg for mounting panel , Internal wiring with PVC insulated but sheathed, stranded copper conductor FRLS (IS-694) marked,1100 volts grade of adequate but not less than 4.0 sq mm size , PCC foundation of suitable size all as specified and directed. with comprising following components. Location : GAPS-2 (i) MCCB 100 Amps, 415 volts, 50 Hz, 4 pole, 16 KA, thermal adjustable – 0.8 to 1In, fixed magnetic at 10In- 05 Nos (ii) MCB TPN 40 Amps, "C" curve,415 volts, 50 Hz - 04 Nos (iii) MCB SPN 63 Amps, "C" curve,415 volts, 50 Hz - 02 Nos (iv) MCB SPN 40 Amps, "C" curve,415 volts, 50 Hz - 02 Nos (v) Digital Ammeter 3 phase -01 No (vi) Digital Volt meter 3 phase ,415 volts AC -01 No (vii) LED pilot lamps- 01 set (RYB)
Supply , installation, connecting & commissioning in replacement of LT feeder pillar box outdoor type of size 0.90 x 0.70 x 0.60 Mtr size factory fabricated made out of MS sheet of thickness 3.15 mm front door openable with locking arrangement mounted on angle iron legs made out of angle iron of size 40x40x6mm, 1.5 mtr long, 1.0 mtr above ground level and 0.50 mtr embedded in PCC blocks of size 0.30x0.30x0.50 mtr- 04 Nos duly painted with two coats of synthetic enamel paint over a coat of red oxide complete with 200 amps rated copper bus bar suitable for 3 phase 4 wire supply system duly drilled holes and making all cable connection with proper thimbles mounted on epoxy based post insulators and with MCCB 200 Amps 4 pole 415 Volt, 35/36 KA -01 No, MCB TPN 80 Amps- 03 Nos, MCB SPN 63 Amps- 04 Nos and including digital multimeter showing ampare, voltage etc complete all as specified and directed.
M&L for painting of platform of any size for LT panels/transformer with two coats of cement base paint including painting of MS gate and XPM jali/fencing all around the plateform with two coats of aluminium paint after preparation of surfaces all as specified and directed .
Material only for Chain link MS galvanised fencing having any size or type complete all as specified and directed .
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts etc including provission of binding wire all as specified and directed.
S & F in replacement for framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars ; barred iron doors ; ladders ; framed balusters ; walk ways ; railings ; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 for support for chain link fencing on transfermer/LT panel platform all as specified and directed.
M&L for brick work sub class 'B' straight or curved on plan exceeding 6m mean radius built in cement mortar 1:3 all as specified and directed .
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces cement plaster 1:4 after cleaning the surface all as specified and directed.
M&L for preparing new wall surfaces plastered or unplastered with and applying under coat followed with subsequent coat of white wash on walls complete all as specified and as directed .
M&L for repair, maint and of broken doors for LT panel and bus bars by welding and incl fixing of new hinges and other material as required at site complete all as specified and directed.
S&F in replacement of onload change over switch with SS enclouser, 160 Amps, 4 pole, terminal shrouds, source separator and phase barriers all as specified and directed.
All as per item No 104 but of capacity 125 Amps.
All as per item No 104 but of capacity 100 Amps.
All as per item No 104 but of capacity 63 Amps.
S&F in replacement of onload change over switch open execution, 160 Amps, 4 pole, terminal shrouds, source separator and phase barriers all as specified and directed.
All as per item No 108 but of capacity 125 Amps.
All as per item No 108 but of capacity 100 Amps.
All as per item No 108 but of capacity 63 Amps.
S&F in replacement of contactor, 4 pole, 415 volts, 50 Hz, 40 Amps with auxilary contacts 2 No + 2 NC confirming to IS/IEC 60947-4-1 & IEC 60947-4-1 all as specified and directed .
All as per item No 112 but of capacity 70 Amps.
All as per item No 112 but of capacity 100 Amps.
All as per item No 112 but of capacity 185 Amps.
M & L for cutting, trimming of branches along the OH conductor of LT/ HT line within 2 mtr distance along both side of line and strictly all branches in one place as directed .
Servicing/calibration of AMF panel such as of controller panel settings, contactor, relay etc, control wiring and rectify the fault if any, cleaning of AMF panel complete all as specified and directed .
Servicing of DG set upto 63 kVA with AMF panel of any make to ensure smooth running of DG set for 30 mins on load. Checking for abnormal sound and leakages, carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. Inspect alternator, stator and rotor for normal speed & proper frequency, examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping up with distilled water, checking V belts with necessary adjustment, checking and retightening of nut bolts including coupling bolts of engine and alternator, checking & cleaning of radiator and leakage testing checking of radiator & fuel supply hose pipes, checking of AVR , excitation diodes, its connections confirming proper output voltage. checking & resetting of valve tappets , inspection of controller panel settings and all components such as relay, contactor etc, control wiring and rectify the fault if any, cleaning of DG set internally using blower, cleaning radiator complete to ensure smooth functioning of DG set and submit the servicing report to engineer in charge. Note : 1. Servicing shall be done by authorised rep of manufacturer. 2 Any other accessories found unserviceable that shall be replaced & paid under respective items of this Sch.
All as per item No 118 but capacity from 100 KVA to 200KVA.
S&F in replacement of Lub oil filter element for 15 to 63 KVA DG Set as per sample all as specified.
S&F in replacement of Lub oil filter element for 100 to 200 KVA DG Set as per sample all as specified.
S&F in replacement of Fuel filter element for 15 to 63 KVA KVA DG Set as per sample all as specified.
S&F in replacement of Fuel filter element for 100 to 200 KVA DG Set as per sample all as specified.
S&F in replacement of Dry type air cleaner for 15 to 63 KVA DG Set as per sample all as specified.
S&F in replacement of Dry type air cleaner for 100 to 200 KVA DG Set as per sample all as specified.
S&F in replacement of V-Belt of fan for 15 to 200 KVA DG Set as per sample all as specified.
S&F in replacement of By Pass Filter for 15 to 63 KVA DG Set as per sample all as specified.
S&F in replacement of By Pass Filter for 100 to 200 KVA DG Set as per sample all as specified.
S&F in replacement of Hose pipe for of DG set cap 15 to 200 KVA as per sample all as specified.
S&F in replacement of radiator hose pipe of DG set cap 15 to 200 KVA as per sample all as specified.
S&F in replacement of Clamp hose radiator of DG set as per sample all as specified.
S&F in replacement of self starter 12/24 volt for DG set 15 to 63 KVA as per sample all as specified.
S&F in replacement of self starter 12/24 volt for DG set 100 to 200 KVA as per sample all as specified.
M&L for replacement of Coolant for DG set of make : Castrol/Indian Oil or equivalent
M&L for replacement of Engine oil 20 W 40 complete all as specified. make : Castrol/Indian Oil or equivalent
M & L for winding of armature winding and field winding with super enamelled copper wire of appropriate gauge incl varnishing of insulating material and heating up, testing etc complete for DG set of capacity 20 to 83 KVA incl taking out the old burnt windings all as specified and as directed.
Repair of PT (Pressure time) fuel pump by dismantling and segregation all parts, replacement of new parts such as filter screen shut down valve, valve elbow, pulsation clamp, idle adjusting screw, high speed spring, governer plug etc in replacement of existing U/S parts re-assembling the pump after repair/ replacement of parts , celebration for DG set of capacity 15 to 200 KVA & testing on completion all as specified and as directed.
Repair to radiator assy Cleaning washing throughly, descaling and M&L for replacement of rubber size paid and MS Nut & Bolts including brazing /repair of cooling tubes with dismantling and segregation upper and lower chamber (tank) including and reassembling complete incl nut, bolt, washers, & spring any type for DG set capacity 15 to 200 KVA all as specified and as directed.
Cleaning grass/mud all in and around the earth pits after taking out pit cover and pouring of salt solution (appx 15 ltr) to existing pit with salt and water ratio 1:5 after that put on the existing pit cover on pit and checking/making connection to the equipments with new/existing GI wire all as specified and as directed. (Note : GI strip should be measured and paid seperately under respective item).
S&F in replacement wheel rim made out of casted aluminium ,anti-rust proof, 12 cm wheel size, pitch circle dia 112 cm, suitable for tubeless tyre including axle, nut bolt washers all as specified and as directed.
S& F in replacement tyre 90/100 R10, tubeless after taking taking out old unserviceable and testing complete all as specified and directed. Make : CEAT ZOOM D/JK BLAZE BA21/ CEAT ZOOM D
Material and labour for construction of earth pit (excluding pit cover) as required at site and as per specification of Electrical plate No-03 of SSR part-1 complete all as specified and directed .
Material and labour for construction of earth pit cover of size 0.45x0.45x0.075 mtr made up of RCC B-1, 1:2:4 along with lifting handle complete and placing on earth pit all as specified and directed.
Disconnecting, dismantling and taking down carefully GI strip of any size up to 32x6mm and seggregating U/S or serviceable parts incl removing from site or setting aside for reuse.
Fixing only GI strip obtained from site as per srl item No-147 above buried in ground upto 50 cm depth or fixed to wall etc including jointing by welding for loop earthing as directed.
Supply & fix GI strip 25x4mm, buried in ground upto 50 cm depth or fixed to wall with nut, bolt & saddles/ insulators etc for loop earthing including welding for joints all as required at site or directed. .
M & L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level)with top edge of earth plate not less than 1.5 meters below ground level connected by 25X4 mm GI strip as earth lead by means of nuts and bolt,thimbles, check nuts, washers of GI or steel including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20 mm graded stone aggregate,with fair finish,internal surface of concrete chamber shall be given internal dia 300mm x 300 mm dia,15 mm thick plaster in CM 1:4 funnel with wire guage mesh ,80 mm thick RCC pit cover 320mm x 320 mm of RCC 1:2:4 Type B1 using 20 mm graded stone aggregate reinforced with XPM jelly and charcoal ,dust and common salt all as shown in electrical plate No 5 of MES SSR Part -1 (1991) and specified including provision of GI strip upto 7.5 metre long protected by 40 mm dia medium grade pipe and watering pipe shall be 20 mm bore medium grade ,including all excavation and earth work and connecting the earthing to an earthing test point and to main switch board as specified and testing on completion complete all as specified and directed. Note: RCC pit cover shall be precast of RCC (1:2:4) type B1, 80 mm thick reinforced with XPM weighting not less than 4 kg/Sqm in lieu of CI cover.
M&L for earthing complete with GI earth plate electrode of size 60cm X 60cm and thickness not less than 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI strip of size 32x6 mm by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia GI pipe connected to equipments and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 making test point and all connections complete all as specified & directed.
Deduct : Total amount of SCH 'A' SECTION-II (SCH OF CREDIT) Rs. 1,34,468.00 to be deducted from Schedule ‘A’ (BOQ) to arrive at the Contract Sum.
M/s USHA ENTERPRISES
M/S SHRI RAM BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .