| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC | ₹1.5 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹1.7 Cr+₹21.1 L (14.1%)Rejected-AOC | ₹1.7 Cr+₹21.1 L (14.1%) | L2 | Rejected-AOC Not lowest |
| 3 | L3₹1.9 Cr+₹43.2 L (29.0%)Rejected-AOC ST NO 5R HIRA SINGH NAGAR KOTKAPURA | ₹1.9 Cr+₹43.2 L (29.0%) | L3 | Rejected-AOC Not lowest |
| 4 | Rejected-Technical | - | - | Rejected-Technical The applicant has not been found eligible to handle more works as NO is reflected in WLR for Q/E Dec 2019 |
Tender Value
₹1.8 Cr
EMD Value
₹2.5 L
Closing Date
29 May 2020, 6:00 pmClosed
HQ Chief Engineer Jalandhar Zone Jalandhar Cantt
HQ Chief Engineer Jalandhar Zone Jalandhar Cantt
PROVN OF TYPE-IV AND TYPE-V MD ACCN FOR MES CIVILIAN OFFRS AT FEROZEPUR CANTT UNDER GE (EAST) FEROZEPUR
2018_MES_193552_1
80971/E8
Open Tender
Civil Works
Lump-sum
60 days
Jalandhar Cantt
All documents as per NIT
8 documents required · 8 mandatory
₹1,000
Garrison Engineer (East) Ferozepur Cantt
₹2.5 L
Yes
27 Jun 2020
29 Feb 2020
1 Jun 2020
29 Feb 2020
29 May 2020
8 May 2020
29 Feb 2020 - 22 May 2020
Amount
Note: (i) Please refer Schedule 'A' Notes given on serial page No. 22, 23, 24(R) to 26(R) of tender documents. (ii) Item from Srl No. 3.00 to 8.02 of this document shall be Part-XII (Miscellaneous items) of BOQ.
LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS
Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule 'A' Part-I brought forward from serial page No. 27(RR).
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-II brought forward from serial page No. 29(R).
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-III brought forward from serial page No. 30(R).
Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule 'A' Part-IV brought forward from serial page No. 32(R).
Lump sum price worked out by the contractor for ROAD, PATH, CULVERT AND PCC HARDSTANDING WORKS as listed in Schedule 'A' Part-V brought forward from serial page No. 33(R).
Lump sum price worked out by the contractor for BOUNDARY WALL WORKS listed in Schedule 'A' Part-VI brought forward from serial page No. 34.
Lump sum price worked out by the contractor for SITE CLEARANCE AND EARTH WORKS as listed in Schedule 'A' Part-VII brought forward from serial page No. 35.
Lump sum price worked out by the contractor for ARBORICULTURE WORK as listed in Schedule 'A' Part-VIII brought forward from serial page No. 36(R).
Lump sum price worked out by the contractor for HOT WATER SUPPLY WORK as listed in Schedule 'A' Part-IX brought forward from serial page No.38(R).
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-X brought forward from serial page No. 39(R).
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-XI brought forward from serial page No. 40.
INTERNAL ELECTRIFICATION WORKS
Material and labour for concealed point wiring complete with 1.5 sqmm (nominal cross sectional area) FRLS PVC insulated multistranded copper conductor in and including heavy duty PVC conduit pipe (ISI marked) including fittings & accessories including 1.5 sqmm FRLS PVC copper conductor multistranded as earth wire connected to the common earth dolly as specified for one light point/fan/exhaust fan/ bell controled by one switch complete all as specified.
All as per item No. 3.01 above but one light point controlled by one, 2 wayswitch for staircase.
All as per item No. 3.01 above but one three pin socket outlet 5 Amp on same board.
All as per item No. 3.01 above but one three pin socket outlet 5 Amp on independent board.
All as per item No. 3.01 above but with 2.5 sqmm cable and 2.5 sqmm copper conductor as earth wire for 3 pin, 15 Amps socket outlet complete.
All as per item No. 3.01 above but with 2.5 sqmm cable and 2.5 sqmm copper conductor as earth wire for 4 light controlled by one switch compelte for building security light. Note for items No. 3.01 to 3.05 - Modular metal flush boxes, white cover with frame & modular switches will be measured & paid for separately under respectiv items.
Supply and fixing modular TV socket compatible with reception of antena satelite and cable net work signals 9.5mm dia connector TV female with coaxial cable and PVC conduit in external wall of the building complete all as specified.
Supply and fixing telephonic connection with modular socket with concealed conduit and telephone cable GI wire 06/02, 0.50mm dia for one pair telephone upto external wall of bldg PVC insulated, PVC sheathed urarmoured and annealed tinned conductor with tape threaded complete all as specified
Supply and fixing modular metal flush box suitable 8 module complete all as specified.
Supply and fixing modular dummy plate complete all as specified.
Supply and fixing lamp holder metal ring for modular fittings inlcuding LED lamp 9 W 220-240 volts 50 Hz complete all as specified.
Supply and fixing ceiling fan 1200mm sweep BEE 5 star rated including provision of cord flexible copper conductor 23/0.0076 three core from ceiling rose to connector complete all as specified.
Supply and fixing exhaust fan heavy duty steel body with louvers complete of 300mm size with bolts,nuts and washers, size of the bolt 15 cm long 12mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan for giving connection complete allas specified. Note: Cost of opening in wall and grouting of mild steel work shall be deemed included in the lump sum cost of the building.
Supply and fixing distribution board vertical TPN 4 way including of MCCB 63/40 A as incomer double door 415Volt with bus bar neutral link complete all as specified. Note : DB should be suitable for IP-43 protection including provision for reversible door.
Supply and fixing energy saving tube light luminaires with diffuser LED with comprising with CRCA MS box and for fit 18 to 20 watt (Max) retro fit tube rod having thermally conductive material heat sink, lumen output 2100 lumens (min) 6500K, power factor more than 0.95, IP-20 Class-I protection with inbuilt LED driver surge protection device, operative on 140 to 270 Volts AC supply complete pre-wired, connection and testing complete all as specified and directed.
Supply and fixing MCB, single pole & neutral 240 volts, capacity 32-40 Amps, B series 50 Hz, 10 KA complete all as specified.
Supply and fixing MCB, single pole 240 volts, capacity 10-20 Amps, B series 50 Hz, 10 KA complete all as specified.
Supply and fixing MCB, single pole 240 volts, capacity 6 - 10 Amps, B series 50 Hz, 10 KA complete all as specified.
Supply and fixing energy saving tube light luminaries with diffuser LED with comprising with CRCA MS box and for fit 18 to 20 watt (Max) retro fit tube rod having thermally conductive material heat sink, lumen output 2100 lumens (Min) 6500K, power factor more than 0.95, IP 20 class-I protection with inbuilt LED driver surge protection device, operative on 140V to 270V AC supply complete pre-wired, connection and testing complete all as specified and directed.
Supply and fixing sub main wiring with two single core FRLS PVC insulated stranded copper conductor 6 Sqmm and 1 x 6 Sqmm for earth continuous earth wire including suitable PVC conduit medium grade ISI marked all as specified and directed. Note : Two runs of PVC cable 6 sqmm & one run of earth wire 6 sqmm will be considered as one unit.
Supply and fixing sub main wiring with two single core FRLS PVC insulated stranded copper conductor 2.5 Sqmm and 1 x 2.5 Sqmm for earth continuous earth wire including suitable PVC conduit medium grade ISI marked all as specified and directed. Note : Two runs of PVC cable 2.5 sqmm & one run of earth wire 2.5 sqmm will be considered as one unit.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt, earth lead GI wire 4mm dia (8 SWG) connected to GI earth plate electrode by means of bolts, nuts, check nuts and washers of galvanized iron and thimbles and other end of earth wire connected to main switch board and protected by galvanized iron medium grade 15mm bore and GI pipe 20mm bore light grade with funnel and wire mesh for watering including necessary excavation and earth works. PCC Chamber in cement concrete (1:3:6) type C-2 & RCC cover in M-20 (Design mix) and all as shown in Electrical Plate No 3 of MES standard Schedule of Rates (Part-I) of 2009 complete all as specified and directed. Notes : (i) Outer edge of earth pit will be 1 m away from the outer edge of PCC chamber. (ii) GI earth wire upto main board is included in this item. (iii) Water pipe shall be provided in slanting position.
Supply and fixing digital type energy meter of rating 10 to 60 amps three phase including PVC box complete all as specified and directed.
INTERNAL WATER SUPPLY WORKS
Supply and fixing wall mixer with telephonic shower and bib tap cast copper alloy polished body screwed down high presure with cruth or butterfly handle including decorated PVC flexible pipe fancy type chromium plated, screwed both ends for iron or unions for 15mm bore steel tubing complete all as specified and directed
Supply and fixing 15mm bore chromium plated water jet of approved quality to be fixed with EWC including PVC connection of 1.00 m long complete all as specified and directed
Supply and fixing 15mm bore chromium plated health faucet Ald Chr 573mm long flexible tube (silver) of aproved quality to be fixed with EWC complete all as specified and directed Make : Jaquar
ARBORICULTURE
Supply and planting of trees of height 2.4 m and above and 2 to 2.5 years old with proportional girth of ever green and or shady species alongwith spikes stakes including preparation composite pits of size 60cm x 60cm x 90cm by excavation in soft/ loose soil and planting trees and refilling of the pit with compost (manure sand and sweet earth mixed in ratio (1:1:4) and maintenance for 2 years (including the period of execution and defect liability period complete all as specified and directed (Tree- Ficus Binjamina, Bottle Palm Tree, Alastomia scholoris etc). Note : The rate for excavation and getting out of soil, rate for mixed earth manure and sand to be including in the unit rate.
Supply and planting of bermuda grass including watering with ploughing of whole site in soft/ loose soil upto the depth of 30cm and removing all the unwanted materials such as stones/ weds tree etc. dressing and levelling the soil to a gradient and slope on complete work as per site requirement filling of manures soil at the ratio (30% manure & 70% sweet soil at entire area to a thickness of minimum 300 mm to meet all finished grade and maintenance for 2 years (including the period of execution and defect liability period all as directed) complete all as specified and directed.
HOT WATER SUPPLY WORKS
Supply and fixing sub main wiring with two single core FRLS PVC insulated stranded copper conductor 4 Sqmm and 1 x 4 Sqmm for earth continuous earth wire including suitable PVC conduit medium grade ISI marked all as specified and directed. Note :Two runs of PVC cable 4 sqmm & one runs of earth wire 4 sqmm will be considered as one unit.
EXTERNAL ELECTRIC SUPPLY WORKS
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6.3mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt, earth lead GI strip 25x4mm connected to GI earth plate electrode by means of bolts, nuts, check nuts and washers of galvanized iron and thimbles and other end of earth wire connected to main switch board and protected by galvanized iron light grade 40mm bore and GI pipe 20mm bore medium grade with funnel and wire mesh for watering including necessary excavation and earth works. PCC Chamber in cement concrete (1:3:6) type C-2 & RCC cover in M-25 (Design mix) and all as shown in Electrical Plate No 3 of MES standard Schedule of Rates (Part-I) of 2009 complete all as specified and directed. Notes : (i) Outer edge of earth pit will be 1 m away from the outer edge of PCC chamber. (ii) GI earth wire upto main board is included in this item. (iii) Water pipe shall be provided in slanting position.
EXTERNAL WATER SUPPLY WORKS
Material and labour for construction of brick masonry valve pit of size 600 x 600 x 600mm (internal size) with mild steel sheet cover 6mm thick and frame of angle iron of size 40x40x 6mm duly painted with two coats of synthetic enamel paint over a coat of red oxide primer including excavation and earth work,150mm thick PCC (1:4:8) type D-2 as in foundation,brick work in cement mortar (1:6), locking arrangement, and all inner size of pit shall be plastered 15mm thick in cement mortar (1:4) and coping in PCC (1:2:4) type B-1 over brick wall complete all as specified and directed.
Material and labour for cutting and jointing the existing pipe line for making branch connection of GI pipe of suitable and making thread for suitable insertion of tee of size 100 x 100 x 50mm and 50 x 50 x 50 connection complete all as specified.
MS SUSHIL KUMAR CONTRACOR
OSHO ENGINEERING PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .