Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.5 LAccepted-AOC 1ST FLOOR H NO 165 GALI NO 16 S B S COLONY KARAWAL NAGAR DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | L1 | Accepted-AOC L1 | |
| 2 | L2₹31.5 L+₹1,003.47 (0.03%)Rejected-Finance BOOTH NO 56 MAIN MARKET SECTOR 40 C CHANDIGARH U T 160036 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160036 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹31.7 L+₹22,005.47 (0.70%)Rejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹32.7 L+₹1.2 L (3.84%)Rejected-Finance SCHEME NO 07 BLOCK NO 22 FLAT NO 03 NEW GURDASPUR DISTT GURDASPUR PB 143521 | GURDASPUR | PUNJAB | 143521 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹37.1 L+₹5.7 L (17.9%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
10 Jul 2023, 6:00 pmClosed
GE NAMS
GE NAMS AMRITSAR
CERTAIN REPAIR/INSTALLATION OF RETROFIT EMISSION CONTROL DEVICE (RECD) TO DG SETS AND ALLIED WORKS AT NAMS
2023_MES_595355_2
GE NAMS-21/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE NAMS
CLASS D CATEGORY b(i)
8 documents required · 8 mandatory
₹500
GE NAMS
₹66,000
Yes
19 Jul 2023
17 Jun 2023
17 Jul 2023
17 Jun 2023
10 Jul 2023
26 Jun 2023
Amount
Supplying, Installation, testing & comissioning of Retrofit Emission Control Device(RECD) in existing 25 KVA/20 KW DG Set by welding of suitable size angle(not less then 50mmx50mmx6mm size of angle iron) for support setructure and suitable size ladder including cutting of old Silencer/mufflur without damaging Diesel Generator set and fixing of new Retrofit Emission Control Device by making necessary modification and painting the new assembly to match existing colour of DG set. The following technical specification and certificate as under:- 1. Technology : DPF (Diesel Particulate filter), wet scrubbing, Diesel Oxides Catalyst type. Device must be made of stainless steel 2. Guaranteed specified Particulate matter (PM 2.5) Carbon Monoxide , Hydrocarbon reduction efficiency: Minimum 70% for all DG Sets. 3. Maximum back pressure of 8.500 Pa exertd by the Emission Control retrofit device at max prescribed load by DG OEM (as per the capacity of the DG set). Necessary precaution to be taken in Exhaust scheme design to avoid condensate/steam back entry to DG sets which is/are not in operation. 4. General Technical requirments for Commissioning Retrofit Emission Control Device(RECD)
a) Emission Control retrofit device shall be complete with safety precautions to ensure no damage should be done to the DG set operation under any circumstances. The Emission control retrofit device should be closely coupled with the DG Exhaust to ensure 100% of the exhaust passes through the Emission Control retrofit device. b) Anti-Vibration mountings shall be provided for complete Emission Control device in case of flexible coupling with the diesel generator exhaust. C) Retrofit Emission control device should have protection against under voltage, under frequency, over frequency, low battery voltage, over current, earth fault, short circuit, phase sequence change etc. d) Automatic main failure (AMF) control panel, where applicable, shall be able to start up the emission control retrofit device without requiring any human intervention. Simillary on restoration of main supply, it shall be able to turn off automatically. e) The Retrofit emission control device shall be with corrosion resistive and heart resistance paint. f) Standard set of tools consisting of a set of 3 spanners, one screw driver, one standard plier and one nose plier of appropriate size shall be provided along with each Emission control retrofit device. 5. The installation work of Emission control Retrofit device to follow the advisory, as per E-in-C Branch letter No.A/37696/Gen/Pol/E2W(PPC) dt 29 Jun 2022. Make : KOEL, Mahindra, Cumminus or as approved by E-in-C's Branch
Description all as per Item No 1.00 above but capacity of 40 KVA Diesel Generator set of any make/Vintage
Description all as per Item No 1.00 above but capacity of 62.5 KVA Diesel Generator set of any make/Vintage
Description all as per Item No 1.00 above but capacity of 100 KVA Diesel Generator set of any make/Vintage
Description all as per Item No 1.00 above but capacity of 250 KVA Diesel Generator set of any make/Vintage
Notes for Item No 1.00 to 5.00: Note: (i) Test report and Type approval certificate of the Retrofit Emission Control Device will be from CPCB, Recognised/approved Laboratories. (ii) Warranty on RECD set of two year after date of completion of work. (iii) Number of Preventive maintenance visits offered in a year during warranty period 2 Visits. (iv) The seller shall provide the trail run (testing) of RECD.The trail run shall be for two Hours.The electrical loading shall not be more then the rated capacity of the DG set. (v) Exhaust piping, extra civil work shall be provided by the contractor without any extra cost from the department. (vi) Drawing for RECD devices shall be got approved by GE before Fabrication. (vii) Any type electricity requirment at site to be provided by the Contractor. (viii) Before and after NABL test certificate from certified lab.
L-7 Primewave Communications
UNITED ENGINEERING CORPORATION
HARPAL ENGINEERS AND BUILDERS
imran construction company
M/S Rohit Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .