Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.1 LAccepted-AOC P 45 KHIRODE VIDYA BINOD AVENUE KOLKATA 700003 | KOLKATA | WEST BENGAL | 700003 | L1 | Accepted-AOC AOC | |
| 2 | L2₹16.1 L+₹61,360.50 (3.96%)Rejected-Finance 1 9 | PRAYAGRAJ | UTTAR PRADESH | 211001 | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹17.8 L+₹2.3 L (14.9%)Rejected-Finance | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | L4₹17.9 L+₹2.5 L (15.9%)Rejected-Finance 44B CIRCULAR GARDEN REACH ROAD KOLKATA 700 023 | KOLKATA | WEST BENGAL | 700023 | L4 | Rejected-Finance HIGHER BIDDER | |
| 5 | L5₹23.2 L+₹7.7 L (49.6%)Rejected-Finance | L5 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
25 Apr 2023, 6:00 pmClosed
VIVEK TANENIA
GARRISON ENGINEER (CENTRAL) KOLKATA T 37 NAPIER ROAD HASTING KOLKATA 700022
REPAIR/MAINT OF INTERNAL ELECTRIC WIRING INCLUDING FITTING, FIXTURES, CEILING FANS, EXHAUST FANS GEYSERSER FOR MD ACCN, KP QUARTERS OFFICERS MD ACCN OTM ACCN (GE OFFICE) INCLUDING MAP PH-ii AT HASTINGS UNDER GE (CENTRAL) KOLKATA
2023_MES_587416_1
8565/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
KOLKATA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (C) KOLKATA
₹50,000
Yes
27 Jun 2023
29 Mar 2023
26 Apr 2023
29 Mar 2023
25 Apr 2023
13 Apr 2023
29 Mar 2023 - 12 Apr 2023
Amount
Taking down point wiring (light, fan, socket and power complete including fixtures and fittings such as switches ceiling roses, pendents , regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody for refixing or for taking credit (credit for above items should be made as per conditions separately) and making good distrubed surfaces of walls, floors, etc.complete all as directed by Engineer-in-Charge.
M&L Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC casing caping of suitable size with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets, regulator etc including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly for one light or fan point controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan /call bell point/ Switch socket outlet 5 amps complete all as specified and as directed. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board..
All as per item No. here-in-before but one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by Engineer-in-charge.
All as per item No. here-in-before but one 3 pin 5 amps switch socket outlet on the independent board with other switch complete all as specified and directed by Engineer-in-charge.
All as per item No. here-in-before but for one light point controlled by two switches two way complete all as specified and directed by Engineer-in-charge.
M&L fo Point wiring surface type with 2.5 sqmm (Nominal Area) PVC insulated stranded single core unsheathed FRLSH copper conductor cable 1100 Volts grade drawn through with and including PVC casing caping with all fittings and accessories of casing caping (like Tee, Bend etc) complete fixed to walls / ceiling etc with and including 2.5 Sqmm (nominal area) PVC insulated unsheathed, stranded, single core FRLSH copper cable as earth continuity wire connecting to common earth point (including supply & fixing of 1.6 mm thick pressed mild steel terminal boxes of suitable size with 3 mm thick PVC /plastic laminated sheet, top cover suitable sizes of brass screws and washers etc. for mounting sockets for 5 pin, 16 Amp Switch socket combination on independent board complete all as specified and directed.
M&L for Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC concealed conduit 20mm dia medium duty with all accessories including fabricated 1.6 mm thick MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets, regulator etc including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fan point controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan/call bell point/ Switch socket outlet 5 amps complete all as specified and as directed. Note: (i) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (ii) Cutting Chases pinning shall be measured and paid separately under relevant item of Sch A
All as per item No here-in-before but one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by Engineer-in-charge.
All as per item No. here-in-before but one 3 pin 5 amps switch socket outlet on the independent board with other switch complete all as specified and directed by Engineer-in-charge.
M&L Point wiring with 2.5 sqmm (Nominal Area) PVC insulated stranded single core unsheathed FRLSH copper conductor cable 1100 Volts grade drawn through with and including PVC concealed conduit 20mm dia medium duty with all fittings and accessories of casing caping (like Tee, Bend etc) complete fixed to walls / ceiling etc with and including 2.5 Sqmm (nominal area) PVC insulated unsheathed, stranded, single core FRLSH copper cable as earth continuity wire connecting to common earth point (including supply & fixing of 1.6 mm thick pressed mild steel terminal boxes of suitable size with 3 mm thick PVC /plastic laminated sheet, top cover suitable sizes of brass screws and washers etc. for mounting sockets for 5 pin, 16 Amp socket outlet on independent board complete all as specified and directed. Note: (i) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (ii) Cutting Chases pinning shall be measured and paid separately under relevant item of sch A
M&L for Concealed point wiring with 1.5 sqmm (nominal area) PVC insulated stranded single core unsheathed FRLHS copper conductor cable 1100 Volts grade drawn through with and including PVC Conduit with all fittings and accessories of PVC Conduit (like Tee, Bend etc) complete fixed to walls / ceiling etc with and including 1.5 Sqmm (nominal area) PVC insulated unsheathed, stranded, single core FRLHS copper cable as earth continuity wire connecting to common earth point for one light / ceiling fan/exhaust fan controlled for mounting modular switche, socket, regulators etc complete complete all as specified and directed by Engr- in-charge. Note : Modular switch boards/boxes and Cutting chases & making good of disturbed surfaces shall be measured and paid separately under relevant item.
All as per item No. here-in-before but one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by Engineer-in-charge.
All as per item No. here-in-before but one 3 pin 5 amps switch socket outlet on the independent board with other switch complete all as specified and directed by Engineer-in-charge.
All as per item No. here-in-before but using 2.5 sq mm size stranded copper conductor cable for one 16 amp switch socket outlet on independent board including 2.5 sq mm FRLHS PVC insulated unsheathed stranded copper conductor as earth lead complete all as specified and directed by Engr-in-charge.
S&F Switch piano, flush type, SP, one way, 5/6 Amps 230/240 Volts, white/ivory finish complete all as specified and directed.
S&F Bell/buzzer push 5/6 amps, flush type, white/ivory finish complete all as specified and as directed.
S&F Switch socket combination multipurpose 2 in 1, 3 pin 6 Amps 230/240 volt flush type complete all as specified and as directed.
S&F Socket outlet 3/5 pin, 6 Amps, 240 volt flush type complete all as specified and as directed.
S&F Switch socket combination multipurpose 2 in 1, 3 pin 15 Amps and one pin 5 amps 230/240 volt flush type complete all as specified and as directed.
S&F Lamp holder suitable for batten fittings complete all as specified and directed by the Engr-in-Charge.
S&F Ceiling rose surface bakelite three terminals 240 volts complete all as specified and as directed.
S&F Call bell ding dong AC 230 volts, single pole complete all as specified and as directed.
S&F Ceiling Fan regulator step type 240 Volt complete all as specified and directed by the Engr-in-Charge.
S&F Switch piano, flush type, SP, one way, 5/6 Amps 230/240 Volts, white/ivory finish as in repair complete all as specified and directed.
S&F Switch socket combination multipurpose 2 in 1, 3 pin 6 Amps 230/240 volt flush type as in repair complete all as specified and as directed.
S&F Socket outlet 3/5 pin, 6 Amps, 240 volt flush type as in repair acomplete all as specified and as directed.
S&F Switch socket combination multipurpose 2 in 1, 3 pin 5 & 15 Amps 230/240 volt flush type as in repair complete all as specified and as directed.
S&F Lamp holder suitable for batten fittings as in repair complete all as specified and directed by the Engr-in-Charge.
S&F Ceiling rose surface bakelite three terminals 240 volts as in repair complete all as specified and as directed.
Fixing only serviceaable Ceiling rose surface bakelite three terminals 240 volts complete all as specified and as directed.
S&F Call bell ding dong AC 230 volts, single pole as in repair complete all as specified and as directed.
S&F Ceiling Fan regulator step type 240 Volt as in repair complete all as specified and directed by the Engr-in-Charge.
Fixing only serviceable Ceiling Fan regulator step type 240 Volt complete all as specified and directed by the Engr-in-Charge.
S&F Sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls. 1 Module/ 2 Module complete for modules complete all as specified and as directed.
S&F Sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls. 3 Module complete for modules complete all as specified and as directed.
S&F Sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls. 4 Module complete for modules complete all as specified and as directed.
S&F Sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls.6 Module complete for modules complete all as specified and as directed.
S&F Sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls.8 Module complete for modules complete all as specified and as directed.
S&F Sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls.12 Module complete for modules complete all as specified and as directed.
S&F Modular cover plate with frame for fixing of modular switches/sockets complete for 2 modules complete all as specified and as directed.
S&F Modular cover plate with frame for fixing of modular switches/sockets complete for 3 modules complete all as specified and as directed.
S&F Modular cover plate with frame for fixing of modular switches/sockets complete for 4 modules complete all as specified and as directed.
S&F Modular cover plate with frame for fixing of modular switches/sockets complete for 6 modules complete all as specified and as directed.
S&F Modular cover plate with frame for fixing of modular switches/sockets complete for 8 modules complete all as specified and as directed.
S&F Modular type switch 6 Amps 230V AC single module one way complete all as specified and as directed.
S&F Modular switch socket combination 3 pin 5 Amps 230 volts flush type,3 module complete all as specified and as directed.
S&F Modular socket out let 3 pin 5 Amps flush type 2 module complete all as specified and as directed.
S&F Modular switch socket outlet multipurpose 3 pin 15 Amps and one pin 5 Amps controlled by one switch complete all as specified and as directed.
S&F Modular electronic step type fan regulator by step type 230 volt.120watt,2 module complete all as specified and as directed.
S&F Modular bell push flush type 1 module complete all as specified and as directed.
Cutting Chases pinning in, for concealed conduit wiring and making goods of disturbed surface not exc 15 cm girth with cement morter 1:3 complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip 32x6 as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip proected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 cm c/c bothways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I complete all as specified and as directed.
S&F Plug and socket in sheet metal enclosures with two pin and earth plug and socket complete with and including MCB SP 20 Amps 240 volts heavy duty including taking town of old unserviceable one complete all as specified and as directed by Engr-in-charge. Make- Legrand/ L&T.
S&F AC starter unit consisting of one 25 Amp capacity starter, one 240 V 25 Amps 10 KA SPN MCB, one 25 Amps socket and one 25 Amps plug top prewired including taking down of old UNSV one complete as specified all as directed by Engr-in-charge. Make : North West / Anchor / Legrand
Taking down unserviceable rusted / damaged MCB DBs of any type and way along with any type MCB and keeping serviceable MCB in safe custody in re-use in the work and making good to the distubed surfaces of walls etc. complete all as specified and as directed.
S&F MCB SPN DB made up with sheet metal double door, phosphorised, power coated, neutral link, earth bar and din rail, 4 way with 200 amps rated bus bar, 240 volts complete all as specified and as directed. Make:- Schneider/ ABB/Legrand/ L&T/ C&S
S&F Sheet metal enclosure for DB's when MCBs to be used 8 way single pole and neutral double door with 200 amps rated bus bar complete 240 volts complete all as specified and as directed. Make:- Schneider/ ABB/Legrand/ L&T/ C&S
S&F MCB TPN DB double door made up with sheet metal, phosphorised, power coated, neutral link, earth bar and din rail, 4 way TPN with 200 amps rated bus bar, 415 volts complete all as specified and as directed. Make:- Schneider/ ABB/Legrand/ L&T/ C&S
S&F MCB TPN DB double door made up with sheet metal, phosphorised, power coated, neutral link, earth bar and din rail, 8 way TPN with 200 amps rated bus bar, 415 volts complete all as specified and as directed. Make:- Schneider/ ABB/Legrand/ L&T/ C&S
S&F Verticle TPN DB 6 Way prefitted MCCB 160 Amps 36 KA 3 pole as incomer and provision of 18 modules, MCB SP as out going , double door , incl Blanking plate , lugs etc complete connection , fixing to wall including taking down old unserviceable one complete all as specified and as directed. Make : L&T DBVTL006GD FOR DB, CM98062OOOO FOR MCCB or equivalent . Note : MCB SP will be measured and paid separately under relevant item.
S&F MCB 6 to 32 Amps, SP, 240 Volts , 'C' curve breaking capacity 10 kA complete all as specified and as directed. Make:- Schneider/ ABB/Legrand/ L&T/ C&S
Fixing only for MCB SP 6 to 32 amps, 240 volts obtained from taking down item here-in-before complete all as specified and as directed.
S&F MCB DP 63 amps 240 volts 'C' curve breaking capacity 10 kA complete all as specified and as directed. Make:- Schneider/ ABB/Legrand/ L&T/ C&S
Fixing only for MCB single pole and neutral of rating 6 to 32 amps 240 volts obtained from taking down item here-in-before complete all as specified and as directed.
S&F Isolator 63 Amps, 415 Volts , 'Triple and neutral with rupturing capacity 10 kA complete all as specified and as directed. Make:- Schneider/ ABB/Legrand/ L&T/ C&S
S&F MCB 6 to 32 Amps, SP, 240 Volts , 'C' curve breaking capacity 10 kA as in repair complete all as specified and as directed. Make:- Schneider/ ABB/Legrand/ L&T/ C&S
S&F MCB DP 63 amps 240 volts 'C' curve breaking capacity 10 kA as in repair complete all as specified and as directed. Make:- Schneider/ ABB/Legrand/ L&T/ C&S
S&F Isolator 63 Amps, 415 Volts , 'Triple and neutral with rupturing capacity 10 kA as in repair complete all as specified and as directed. Make:- Schneider/ ABB/Legrand/ L&T/ C&S
Taking down old burnt/unserviceable submain wiring with aluminum/copper conductor PVC insulated cable of any size drawn through PVC casing caping/ PVC Conduit pipe including GI wire accessories etc. and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
M&L Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 4.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 4.0 Sqmm as earth lead drawn into rigid non metalic PVC conduit of size 20 mm dia including all fittings complete all as specified and as directed. Note:- Two runs of 4 Sqmm conductor as main wire and one run of 4 Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit.
M&L Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 6.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 6.0 Sqmm as earth lead drawn into rigid non metalic PVC conduit of size 20 mm dia including all fittings complete all as specified and as directed. Note:- Two runs of 6 Sqmm conductor as main wire and one run of 6 Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit.
Taking down and opening out the ceiling fan/wall mounted upto1400 mm sweep for inspection, removing bush / bearing, cleaning of bush / bearing, replacement of unserviceable / worn out bearing / bush, shaft, removing burnt out coils from the slots, cleaning and repairing of slots complete including materials like split pin,rubber reel etc reassembling and refixing of fan at same location or any other situation complete all as specified and as directed. Note : Spare parts shall be measured & paid separately under relevent item
Rewinding of ceiling or wall mounted fan motor with super enamelled copper winding wire of suitable size & varnishing including testing of fan after rewinding complete all as specified and directed.
Supply only ball bearing suitable for 1200/1400mm sweep Ceiling fan of any make complete all as specified and directed.
Supply only capacitor of 2.5 mfd for Ceiling Fan complete all as specified and directed.
Supply only gun metal bush of suitable size for ceiling fan of sweep 1200mm/1400mm as per existing one complete all as specified and directed.
Supply only nuts, bolts, for Ceiling fan complete all as specified and directed.
Supply only shafts for ceiling fan suitable for 1200mm sweep complete all as specified and directed.
Supply only PVC connector for Ceiling Fan complete all as specified and directed.
Supply only rubber reel insulator for Ceiling fan complete all as specified and directed.
Supply only S hook as standered shape and size for fixing Ceiling fan complete all as specified and directed.
Supply only mild steel down rod 16mm dia ,1.5m long for fixing Ceiling fan complete all as specified and directed.
Supply only fan blades for fixing Ceiling fan complete all as specified and directed.
M&L Painting of ceiling fan/wall mounted fan of any size and sweep complete with synthetic enamel paint by spraying including filling with cavities with filler, after cleaning all dust etc complete all as specified and directed.
S&F 25 mm dia PVC conduit pipe, heavy duty with all fixing accessories including taking town of old unserviceable one complete all as specified and as directed.
S&F 32 mm dia PVC conduit pipe, heavy duty with all fixing accessories including taking town of old unserviceable one complete all as specified and as directed.
Taking down and opening out the exhaust fan upto 450 mm sweep for inspection, removing bush / bearing, cleaning of bush / bearing, replacement of unserviceable / worn out bearing / bush, shaft, removing burnt out coils from the slots, cleaning and repairing of slots rubber reel etc. reassembling and refixing of fan complete including all as specified and as directed. Note : Spare parts shall be measured & paid separately.
Rewinding of exhaust fan motor with super enamelled copper winding wire of suitable size & varnishing including testing of fan after rewinding complete all as specified and directed.
M&L Painting of exhaust fan of any size and sweep complete, in situ with approved colour synthetic enamel paint by spraying including filling with cavities with filler, one coat after cleaning all dust etc.complete all as specified and directed.
Supply only bush suitable for exhaust fan complete all as specified and directed.
Supply only ball bearing suitable for exhaust fan complete all as specified and directed.
Supply only capacitor 3.15 mfd for exhaust fan complete all as specified and directed.
Taking down carefully unserviceable geyser of any type and make from site after disconnections of water & electrical connections & carrying out to MES store yard for inspection and thereafter to workshop for repair & replacement of components such as heating element, thermostate, cable, neon lamp, plugtop, outer casing, plates & repair work to apparatus plate etc and carrying back to MES storeyard for testing and refixing at site and making water & electrical connection on completion and complete all as specified and as directed. NOTE: Spares shall be measured and paid separately under relevant item.
M&L Painting of geysers 25 ltrs capacity at site/at workshop with one coat of synthetic enamel paint (white) best quality including preparation of surfaces with brush, cleaning agents etc complete all as specified and directed.
Supply only following spares for geysers:- (a) Heating element 1.5KW including rubber gasket ISI marked suitable for existing geysers complete all as specified and directed.
(b) Heating element 2.0 KW including rubber gasket ISI marked suitable for existing geysers complete all as specified and directed.
(C) Thermostate for suitable existing geyser of 25/50 litrs capacity complete all as specified and directed.
(d) Chromium plated copper pipe of length not less than 60cm including washers for incoming & outgoing water connections complete all as specified and directed.
(e) Apparatus plate assembly complete for geyser of capacity 25/50 litrs capacity complete all as specified and directed.
(f) Outer casing made out of 22 SWG MS sheet suitable for geyser of capacity 25 litrs complete all as specified and directed.
(g) Split plate bottom cover made out of 22 SWG MS sheet suitable for 25 litrs capacity geyser complete all as specified and directed.
(h) Split plate Top cover made out of 22 SWG MS sheet suitable for 25 litrs capacity geyser complete all as specified and directed.
(j) Insulating material glass wool complete all as specified and directed.
(k) Element holding brass stud complete all as specified and directed.
(l) Element holding clamp complete all as specified and directed.
(m) Fusible metal plug complete all as specified and directed.
(n) Neon lamp round/square with connection lead complete all as specified and directed.
(o) Non return valve 1/2" for geyser inlet complete all as specified and directed.
(p) Storage tank fabricated from copper sheet gauge ,capacity 25 ltr complete all as specified and directed.
(q) 3 inch cross bolt nut
M&L brazing / gas welding of inner container copper of 25 ltr/ 50 ltr capacity any make for making leak proof complete all as specified and directed.
S&F "KLASS" series Recessed mounted adjustable downlight for accent lighting white powder coated recessed mounted fixture Pressure die cast aluminium housing with highly efficient reflector and making hole as per size of light complete all as specified of make Bajaj cat No BRDCSL 9W NW or equivalent in CG Philips
S&F Skylite mini R recess mounted LED 1x1 luminaire white powder coated screwless design complete all as specified and as directed by Engr-in-charge Make: Bajaj cat Par No BCTBLR 18ZT WH or equivalent in philips/CG/Surya
S&F in replacement skylite mini R recess mounted LED 1x1 luminaire white powder coated screwless design complete incl taking down old Unsv all as specified and as directed by Engr in charge Make Bajaj cat Par No BCTBLR 18 ZT WH or equivalent in philips/CG/Surya
S&F in replacement energy efficient LED bed side light 3 watt flexible goose neck with premium material white complete all as specified Model No 48242/30/30/ of make Philips or equivalent in CG Havels
S&F Building security light pressure die cast housing with individual LEDs with modular secondary optics security light luminaires 30 watt LED with 50mm dia light grade GI pipe bent to shape of 45" 1.5 mtr long and nuts bolts including fixing arrangement after taking down old Unserviceable One Make: Bajaj Model No BRLEP 30 W LED WH or equivalent Make of Crompton Greaves or philips or etc
S&F in replacement for louvers of exhaust fan upto the size of 400mm sweep upto four storey building complee including arrangement of scaffolding for fixing of louvers with all nuts, bolts and washers and finished properly with cement work as per existing complete all as specified and as directed by engr in charge
K.P Construction Co
VAGIRATHI ENGINEERING COMPANY
INDIA ELECTRICAL EQUIPMENTS
KAMAKHYA TRADERS
Commercial Electric Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .