| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹32.1 LAccepted-AOC D1C 47A JANAK PURI NEW DELHI 110058 | NEW DELHI | DELHI | DELHI | 110058 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹35.2 L+₹1.4 L (4.11%)Rejected-AOC WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | L-2 | Rejected-AOC L-2 | |
| 3 | L-3₹39.9 L+₹6.1 L (18.1%)Rejected-AOC A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L-3 | Rejected-AOC L-3 | |
| 4 | L-4₹43.2 L+₹9.4 L (27.9%)Rejected-AOC | L-4 | Rejected-AOC L-4 | |
| 5 | Rejected-Technical BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | - | Rejected-Technical No, not enlisted in eligible category |
Tender Value
₹39.3 L
EMD Value
₹78,600
Closing Date
25 May 2024, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICE, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
REPAIR MAINTINANCE OF LT HT CABLES PANELS STREET LIGHTS AND CERTIAN ALLIED WORKS IN SSPL LAB AND REPAIR MAINT OF FIRE ALARM DETECTION SYSTEM AND ALLIED WORKS AT ZONE-B AT KWC AREA UNDER GE I RND DELHI
2024_MES_647749_1
GE/RND-111/DLI/2023-2024
Open Tender
Civil Works
Item Rate
180 days
Delhi
Class-D, Cat- b(i)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹78,600
9 Sept 2024
23 Mar 2024
27 May 2024
23 Mar 2024
25 May 2024
11 May 2024
Amount
S&F in repair end termination joint 11 KV indoor type, end termination heat shrinkable of size 3x 120 to 185 sqmm including thimbling, nut/bolts & washers, HV insulating tape etc. complete all as specified and as directed.
S&F in repairs straight through joint 11 KV heat shrinkable of size 120 to 185 sqmm including thimbling, nut/bolts & washers, HV insulating tape etc. complete all as specified and as directed.
S&F in replacement of ACB 4 pole, 415 V with thermal magnetic release (Manual fixed type) of capacity 800 Amps complete all as specified & directed.
All as per item srl No 3.00 above but capacity 1250 Amps.
Supply and laying in replacement PVC insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400 Sqmm 3.5 core including suitable size aluminium lugs properly crimpled with crimping tools including testing complete all as specified and directed
All as per item srl No 5.00 abocve but area 300 Sqmm 3.5 core
All as per item srl No 5.00 above but area185 Sqmm 3.5 core
All as per item srl No 5.00 above but area 120 Sqmm 3.5 core
Supply and laying in replecement XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 120 Sqmm 3 core including testing complete all as specified & directed
All as per item srl No 9.00 above but area 185 Sqmm 3 core
Supply and laying in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 4 core including suitable size Aluminium lugs properly crimpled with crimping tools including testing complete all as specified and directed
Supply and laying GI pipe light grade in replecement of 100mm dia laid in trenches for protection of UG cable complete all as specified & directed
All as per item srl No 12.00 above but 80mm dia
Taking proper shutdown & Isolate the HT electric supply and taking out the trolley of VCB/OCB HT 11KV 300 to 630 Amps of any make and type and servicing of all minor/major parts of the VCB by cleaning isolating contact moving parts,removing dust particle from the bus bar chamber spout gear mechanism, repair to motor charge spring mechanism,tightening of all nut & bolts of entire trolley component as directed , inserting the trolley, testing the complete HT electric supply and putting on supply on load complete all as specified & directed. Note:- All cleaning /testing equipment/ safety equipment material shall be provided by the contractor and rate for the same shall be demed to be included in quoted rates.
Calibration of relay of 11KV HT VCBs and 1.1KV ACBs installed at various sub stn at KWC area complete all as specified and directed. Note:- 1. All testing & calibration equipment with all accessories shall be brought by the contractor and rate for same is deemed to be included in quated rates. 2. The complete test report shall be submitted by the contractor to Engr-in-charge/GE(I)R&D Delhi
S&F in replacement of vaccum interrupter complete all as specified and directed.
S&F in replacement of big gear and small gear with all fixing arrangement complete all as specified and directed.
S&F in replacement of closing spring assembly complete all as specified and directed.
S&F in replacement of tripping spring assembly complete all as specified and directed.
S&F in replacement of charging motor cut off limit switch complete all as specified and directed.
S&F in replacement of spring charging handle motorized mechanism of VCB complete all as specified and directed.
S&F in replacement of push button bracket assembly complete all as specified and directed.
S&F in replacement of bus bar support insulator 75 mm dia including all fixing accessories complete suitable for VCB/HT Bus bar chamber all as specified and directed.
S&F in replacement of bus bar barrier as per existing (set of three) with nuts bolts complete all as specified and directed.
S&F in replacement of toggle switch for space heater complete with all accessories all as specified and directed.
S&F in replacement of Charged/Discharged indication assembly complete all as specified and directed.
M&L in replacement of control wiring for AMFpanel with 2.5 Sqmm copper conductor FRLSH cable including proper laying with the help of locking device as per manufacturer instruction complete all as directed
Taking down repairable potential transformer of HT VCB 11 KV/ 110 V of any make, opening & dismentling the complete unit and refixing after carry out the following repairs/replacement :- (a) Rewinding of transformer as per existing gauge and pattern. (b) Cleaning and servicing of the PT. (c) Replacement of wornout nuts/bolts and other minor parts including HRC Fuse. (d) Soldering / tightening of loose connections. (e) Replacement of potential transformer oil having dielectric strength upto 50 KV. (f) Painting of outer portion of PT with synthetic enameled paint of grey colour of approved make. (g) Testing of the PT's for proper functioning to the entire satisfaction of the Engineer- in-charge
S&F in replacement of potential transformer of HT VCB 11 KV/110 V of any make complete all as specified and as directed
S&F in replacement of 11 pin anti pumping relay 110V DC complete all as specified and directed.
S&F in replacement of bottom terminal with jaw contact complete all as specified and directed.
S&F in replacement of top terminal with jaw contact complete all as specified and directed.
S&F in replacement of space heater 230V AC 80W complete with all accessories all as specified and directed.
S&F in replacement of thermostat complete with all accessories all as specified and directed.
S&F in replacement of PT epoxy female bushing suitable for R-Y-B phase complete all as specified and directed.
S&F in replacement of PT epoxy male bushing suitable for R-Y-B phase complete all as specified and directed.
S&F in replacement of PT fuse 11 KV complete all as specified and directed.
Dehydration and filtration of transformer oil with proper dehydration machine to achieve dielectric strength between 45 to 60 KV including testing/recording of dielectric strength result before and after of dehydration complete all as specified and as directed.
Supply and topping up transformer oil having dielectric strength not less than 60 KV complete all as specified and directed.
Taking shut down from main substation and drain out the transformer oil and to be collected in barrel by opening the transformer cover of capacity 400 to 500 KVA by unscrewing the nuts/bolts and washers and kept in safe custody and reuse the same, and checking any type of leakage from both HT and LT side including cleaning the sludge etc depositing in the core and tank by using soft brushes and clean with old transformer oil, refilling of transformer oil including refixing of top cover including nut/bolts etc and testing the input & output voltage and adjustment of the voltage through tape changer if required complete to the entire satisfaction of Engineer- in-charge.
All as per srl item No 40.00 above but of capacity 630 KVA
S&F in repair HT bushing 11KV suitable for 400 to 500 KVA Transformer including brass rod complete with gasket as per matching to existing all as specified and directed.
S&F in repair LT bushing 11KV suitable for 630 KVA to 1000 /1500 KVA transformer including brass rod complete with gasket as per matching to existing all as specified and directed.
S&F in repair head gasket sheet 6mm thick suitable for Transformer 400 KVA to 500 KVA capacity including replacement of nuts, bolts, washers including necessary T&P required at site complete all as specified and directed.
S&F in repair head gasket sheet 6mm thick suitable for Transformer 630 KVA capacity including replacement of nuts, bolts, washers including necessary T&P required at site complete all as specified and directed.
S&F in repair Dehydrating breather assembly complete with silica gel grains in the breather assembly suitable for transformers 400 KVA to 630KVA as per matching to existing complete all as specified and directed
S&F in repair temperature gauge analog type complete with all accessories as per matching to existing complete all as specified and directed
S&F in repair voltmeter digital type for voltage range of (0-500V) including all accessories and wiring complete all as specified and directed.
S&F in repair ammeter digital type for current range of 0-1000 Amps as per matching to existing including all accessories and wiring complete all as specified and directed.
S&F in repair power factor meter digital type for frequency range (45-65 Hz) as per matching to existing one including all accessories and wiring complete all as specified and directed.
S&F in repair three phase over current earth fault relay MC-61 as per matching to existing one including all accessories and wiring complete all as specified and directed.
S&F in repair three phase overcurrent earth fault relay MC-61A as per matching to existing one including all accessories and wiring complete all as specified and directed.
S&F in repair three phase digital KV volt meter range up to 15 Kv as per matching to existing one including all accessories and wiring complete all as specified and directed.
S&F in repair LED type Indicating lamp of voltage AC/DC set of RYB, as per matching to existing complete all as specified & directed.
S&F Battery Charger of capacity 24 volt for AMF panel complete all as specified & directed.
S&F in repair Current Transformer as per matching to exisitng complete all as specified and directed.
S&F in repair Multifunctional meter complete all as specified and directed
S&F in repair VCB Power Pack unit 24 Volt DC 7 AH with battery bank for backup including panel as per matching to exisitng complete all as specified and directed
Excavation in trenches in soft/loose soil not exceeding 1.5m depth & not exceeding 1.5m in width over energised LT cables for carrying out brick work for preparation of cable duct including for taking out and relaying of LT Cables complete all as specifed & directed
Excavation in trenches in hard/dense soil not exceeding 1.5m depth & not exceeding 1.5m in width over energised LT cables for carrying out brick work for preparation of cable duct including for taking out and relaying of LT Cables complete all as specified & directed
Supply & laying dry fine sand for cushioning of underground cable laid in trenches/duct complete all as specified and as directed. Note : Punned thickness shall be measured.
Supply and laying in trenches burnt brick sub class 'B' standard size for cable protection keeping width of the brick parallel to the length of the cable all as specified and directed.
Supply and laying un-reinforced factory made precast concrete cable cover , class HV, type 1, flat size-300x180x40 mm complete all as specified and directed
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm thick as in soft/loose soil complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level and not exceeding 1.5 mtr above the starting point complete all as specified and directed.
S&F in replacement of 3 Pole MCCB, 250 Amp, 50 Hz, 415 V with rupturing capacity 35 KA complete all as specified & directed
S&F in replacement of 3 Pole MCCB, 400 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified & directed
S&F in replacement of 3 Pole MCCB, 630 Amp, 50 Hz, 415 V with rupturing capacity 50 KA complete all as specified & directed.
S&F in replacement of 4 Pole MCCB, 250 Amp, 50 Hz, 415 V with rupturing capacity 35 KA complete all as specified & directed.
S&F in replacement of 4 Pole MCCB, 400 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified & directed.
S&F in replacement of 4 Pole MCCB, 630 Amp, 50 Hz, 415 V with rupturing capacity 50 KA complete all as specified & directed.
S&F in repair Capacitor Bank MPP-H, 5 KVAR capacity rated 440 Volts AC,3ø,50HZ ,Delta connection, Round type complete all as specified and directed.
S&F in repair Capacitor Bank MPP-H, 10 KVAR capacity rated 440 Volts AC,3ø,50HZ ,Delta connection, Round type complete all as specified and directed.
S&F in repair Capacitor Bank MPP-H, 20 KVAR capacity rated 440 Volts AC,3ø,50HZ ,Delta connection, Round type complete all as specified and directed.
S&F in repair Capacitor Bank MPP-H, 25 KVAR capacity rated 440 Volts AC,3ø,50HZ ,Delta connection, Round type complete all as specified and directed.
Supply and laying GI pipe light grade size 40 mm dia fixed on wall/laying in trench including all connected fitting/acessories including taking old unserviceable GI Strip complete all as specified and directed
Supply and fixing in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Supply and fixing in repair PVC pipe of size 20 mm dia medium grade iicluding all connected acessories complete all as specified and directed
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron strip of 25x4 mm by means of Copper nuts, bolts and washers. Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following:- (a) GI strip of size 25mm x 4mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.Angle iron frame made of 40x40x4 mm angle iron for 30x30 cm PCC pit for holding the pit cover and Apply two coat of syntheticnenamel paint over one coat of red oxide zinc chrome primer on exposed steel surfaces and two coat of hot tar on embedded portion of steel surfaces
M&L Galvanised iron strip 25x4mm buried in ground including necessay excavation & earth work in soft/loose soil and removal of excavated naterial n. exc 50m and depositing where directed.
Supply & Laying in replacement synthetic insulating mat of size 2m x 1m x 2.5mm thick for voltage upto 11 KV complete all as specified and as directed.
M&L in replacement MS chequred plate of suitable size for cable duct cover 6mm thick and earth pit cover all as specified and directed.
Supply only Electrical insulation HT tape of 3/4"width of 30 feet length Etylene Propylene backing highly comfortable to wrap snugly over most any shape streches up 100 percent to provide avoid moisture, resistant insulation tape of Make-Scotch.
Supply only Fix CRC 2-23 Electrical equipment (contact) cleaner spray used for prevent electronic malfunction equipment caused by water penetration, humidity, corrosion etc and of 500ml can complete all as specified and directed.
Supply and Fix in replacement earth pit chamber alongwith cover of Polymer, FRP Pit cover of heavy high grade polypropelene for high stress and starin level of size 225x300x195mm complete all as specified and directed.
S&F in replacement ACP retro sign board of size 1.5x1.1 Mtr using retro reflective high intensity prismatic reflective sheeting. The back ground of board is Blue Colour with white border and writing letter, numbers white colour mentioning the HT/LT substation Details, and Single line Schematic diagram of substation. Retro sign board shall be pasted on 3mm thick ACP sheet. The board shall be fixed on Wall including fixing of fastners, nuts, bolts, washer etc complete all as directed by Engineer-in-Charge at site. Make: ALOMAX/INDO BOND/ALUTEC.
S&F in replacement lead acid battery of size 12 Volt, 42AH including charging complete all as specified and directed. Make : Exide, Amaron, Luminous, Amara Raja
S&F in replacement aluminium sector lugs (long barrel type) for HT connection of size upto 150 sqmm 3 core.
S&F in replacement aluminium sector lugs (long barrel type) for HT connection of size 185 to 400 sqmm 3 core.
S&F in replacement aluminium sector lugs (long barrel type) for HT connection of size 500 to 630 sqmm 3 core.
S&F in replacement aluminium sector lugs (short barrel type) for LT connection of size up to 50 sqmm 3.5 core.
S&F in replacement aluminium sector lugs (short barrel type) for LT connection of size 70 to 95 sqmm 3.5 core.
S&F in replacement aluminium sector lugs (short barrel type) for LT connection of size 120 to 185 sqmm 3.5 core.
S&F in replacement aluminium sector lugs (short barrel type) for LT connection of size 240 sqmm 3.5 core.
S&F in replacement aluminium sector lugs (short barrel type) for LT connection of size 300 sqmm 3.5 core.
S&F in replacement aluminium sector lugs (short barrel type) for LT connection of size 400 sqmm 3.5 core.
S&F in replacement aluminium sector lugs (short barrel type) for LT connection of size 630 sqmm 3.5 core.
Taking proper shutdown , disconnecting the LT and HT electric main from transformer of any capacity, removing the transfomer of any capacity from pole/structure/ platform shifting to authorised workshop after draining out the transformer oil at site, dismantling and disconnecting damaged HT/LT coil to facilate necessary repairs, rewinding/reconditioning reassembling the tranformer, bringing back to the site, taking out dehydrated old trasformer oil and connecting with existing electrical system of HT and LT including testing complete all as specified and directed. Note : (winding wire and othe items mentioned in schedule will be measured and paid separately)
Rewinding/reinsulation of LT/HT coils of any size and type of transformer including cleaning the brunt out insulating materials, brazing and rewinding with appropriate turns and size of super enamelled DPC insulated copper winding wire of appropriate gauge including filling insulation paper etc all as specified and directed by engr-in-chage Note :- (i) Weight, number of turns, gauge, insulation of winding wire shall be as per OEM. (ii) Work of rewinding shall be carried out through OEM or their authorised vender only.
Supply and laying in replacement in trenches, fixed to wall / pole/ tray etc UG cable XLPE insulated armoured heavy duty electric UG cable with aluminum conductor 1100 volts grade of cross sectional area of 25 Sqm 3.5 Core size all as specified and as directed.
All as per Ser item No. 100 above but size 35 sqmm 3.5 core
All as per Ser item No. 100 above but size 10 sqmm 2 core
S&F in replacement Junction box SMC KIOSK box water proof of size 30x200x100 mm incl fixing of terminal connector 100A 4 pole suitable for in and out connection of 4 core cable fixed on pole complete.
M & L for PCC (1:2:4) type B2 using 20 mm graded stone aggregate for coping of pole around pole all as specified and as directed by Engineer-in-Charge.
S&F in replacement LED Post Top Lantern 40 watt luminaire with diffuser and painted spun aluminium deflector including taking down old unserviceable .
S&F Powder coated pressure die cast aluminium SMD LED street light wirh heat resistant toughened glass of capacity 90 Watt including taking down old unserviceable complete all as specified and directed. Make : Cat Part No. LTESS190WLED of C&C or equivalent of Havells/Orient Electric.
S&F Powder coated pressure die cast aluminium SMD LED street light wirh heat resistant toughened glass of capacity 120 Watt including taking down old unserviceable Make : Cat Part No. LTESS1120WLED of C&C or equivalent of Havells/Orient Electric.
S&F LED flood light with pressure die cast aluminium housing 120 Watt completed with connection including taking down old unserviceable complete all as specified and directed.
S&F LED flood light with pressure die cast aluminium housing 250 Watt completed with connection including taking down old unserviceable complete all as specified and directed.
S&F in replacement of driver for 90W LED street light fitting of make C&S or equivalent of Havells/Orient Electric.
S&F in replacement of driver for 120W LED street light fitting of make C&S or equivalent of Havells/Orient Electric.
S&F in replacement of GI pipe light grade 50mm dia for laying of protection of UG cable complete.
Supply and Fixing in replacement of Timer switch Astronomical type ,415 Volt three Phase of 63 Amps rating with Three Pole ML-4 contactor incl one Toggle switch for Auto, off and Manual function and incomming MCB TP internally pre wired complete and Fitted inside steel enclosure all as per site requirement and directed by engr-in-charge. Make- Legrand or equivelant in Havells/L&T.
Supplying, installation, testing & commissioning in replacement of two loop panel micro processor based intelligent Analog addressable fire alarm control panel micro processor based networkable and expandable with dual stage alarm facilities like hooter , fire / fault indicators , audio visual signals , auto learn features PC networking connectivity, communication facility with battery backup for 8 hrs normal operation and 15 minutes alarm operation. The control panel shall be provided with hot - redundant CPU (degraded mode is not acceptable). The control panel, battery charger etc shall be UL listed. The panel shall be 2 loop capacity & it shall be capable to extend upto 4 loops. The panel shall consist of LCD display and for net working with software and programming including maintenance free batteries all as specified and directed complying with BS EN 54 two loop panel of capacity from 99 detectors & 99 modules upto 200 detectors and modules (per each loop) complete as per specifications.
Supply, installation, testing and commissiong in replacement of intelligent addressable thermal detector with rate of rise cum fixed temperature thermistor as per IS 2175 complete with base as required.
Supply, installation, testing and commissioning in replacement of Fire Alarm Siren electronic type horizontal single stage continuous normal operation for atleast 50 minute with sound level 65 DB to 120 DB measured at 1.5 mtr with sound output +5 db for 3500 meter range fixed on building top level roof complete as required.
S&F in replacement Addressable single action manual call point resettable type having an integrally mounted addressable module that monitor and reports contact status all as specified and directed
S&F in replacement Analogue addressable short circuit / fault isolator module capable of monitoring shorted loop circuit and automatically restore communication when shorted conditions are re- corrected all as specified and directed
S&F in replacement Analogue addressable control modules for all as specified and directed
S&F in replacement Response indicator for all detectors located above false ceiling all as specified and directed
S&F in replacement Analogue addressable duct detector with multiple sensitivity level, programmable for timed automatic sensitivity all as specified and directed
S&F in replacement Addressable Dual tone electronic sounder / hooter enclosed in MS box with LED indication hooter all as specified and directed
Supplying, installation, testing & commissioning in replacement of addressable manual call point complete all as directed.
Supply Installation, Testing and commissioning in replacement of 100 Watt Amplifire complete, all as specified and directed.
Supply, Installation, Testing and commissioning in replacement of 6 Watt ceiling/Wall Speaker complete, all as specified and directed.
Supply, installation, testing and commissioning in replacement of addressable phone control module complete as required.
S&F in replacement glow in dark FIRE EXIT sign board with man running arrow symbol and stair of dimension 12" X 6" X 8 mm decorative transparent acralic, including fixing arrangment all as specified and directed .
S&F in replacement Analog addressable fire alarm REPEATER PANEL micro processor based networkable and expandable with dual stage alarm facilities like hooter , fire / fault indicators , audio visual signals , auto learn features PC networking connectivity, communication facility with battery backup for 8 hrs normal operation and 15 minutes alarm operation. The repeater panel should have LCD display and for net working with software and programming including maintenance free batteries all as specified and directed.
Taking down unserviceable wiring and Supply and Fix in repair 2 x 1.5 sqmm PVC insulated unsheathed, FRLS multistranded copper conductor cable, 1100V grade as per IS 1554 Part I drawn through and including ERW steel conduit 19mm dia duly painted on surface to wall/ ceiling by means of MS screws and saddles connected to MC box, sounder and main control panel as per fire standard all as specified and directed.
S&F in replacement 1100V grade, 6 C x 1.5 sqmm FRLS multistranded copper conductor, PVC insulated, PVC sheathed armoured cable as per IS 1554 Part I all as specified and directed
S&F in replacement 1100V grade, 2 C x 1.5 sqmm FRLS multistranded copper conductor, PVC insulated, PVC sheathed armoured cable as per IS 1554 Part I all as specified and directed
Attending URGENT COMPLAINTS of Fire Alarm and detection System of any nature in Zone-B / KWC area of DRDO complex at Timarpur on urgent call basis immediately by OEM of Fire Alarm ONLY, issues may be due to fault in Fire Alarm Control panels, re-setting of fire alarm panel, LCD Display, PC networking connectivity, communication facility, battery, Non functioning of Repeter Panel, All types of Heat /Smoke detector, Control cable, Addressable manual call point, speaker, thermal detector, Hooter, Siren, Armoured copper cable, Repair to short circuit of fire alarm wiring 2 x 1.5 sqmm PVC insulated unsheathed, FRLS multistranded copper conductor cable, 1100V grade drawn through ERW steel conduit 19mm dia etc and testing for functionility of Fire Alarm system of building / installation by OEM including replacement of defective & worn out parts by new spares as specified and directed .
Maintenance /servicing to be carried out as per manufacturer instruction for smooth functioning to Fire Alarm and detection System by OEM only for respective building / installations in Zone-B / KWC area of DRDO complex at Timarpur once in a month including replacement of unsv parts by new spares such as heat/smoke detectors, short circuited cables, any type of addressable devices etc and re-setting / testing for healthy functioning of Fire Alarm system , providing fire alarm operation skills to the users and performing demo infront of the users of the respective builing and MES team , obtaining the signature from the works department of the respective Lab complete all as specified and directed . Note for ser item No. 133 & 134 :- 1. The contractor shall provide and deploy technician employed through OEM of Fire Alarm and detection system with helpers for proper servicing / maintenance (as directed by GE / Engineer-in-charge) and site engineer shall report at 0900 hrs as per maintenance schedule upto 1700 hrs including carrying out minor repairs as required to Make the system in order / functional complete all as specified and directed by JE E/M / Engineer-in-charge (within 24 hrs) 2. The complaints shall be attended with in 24 hrs. If the complaints is/are not attended /not completed on the same day (except repair/ replacement of major items recovery will be done as follows (a) After 24 Hrs, Rs - 1000.00 Per complaint per day. The decision of GE on recovery against penalty shall be final and binding and No representation whatsoever shall be entertained. 3. The technicians for repair of Fire Alarm and detection system can be called during non-working days/hrs (i.e. Sunday, Holidays & after working hrs) for any vital complaint at DRDO area. 4. The contractor has to produce job card duly signed by user & JE E/M to Engineer-in-charge 5. Each Building/Installation shall be measured as each job.
Supply and installation in repalcement of fire Extinguisher Mechanical Foam type (AFFF ) 4.5/5 Ltrs capacity confirming to IS-10204 complete all as specifed and directed.
Supply and installation in repalcement of fire Extinguisher Foam type 50 Ltrs capacity confirming to IS-10204 complete all as specifed and directed.
Supply installation in repalcement of fire Extiguisher Dry Chemical Power(ABC Type) 4.5/5 Kgs capacity confirming to IS-13849 complete all as specifed and directed.
Supply installation in repalcement of fire Extiguisher (ABC Type) Trolley Mounted 25 Kg capacity confirming to IS-13849 complete all as specifed and directed.
Supply and installation in repalcement of fire Extinguisher CO2 type 3 Ltrs capacity confirming to IS-2878 complete all as specifed and directed.
Supply and installation in repalcement of fire Extinguisher CO2 type 9 Ltrs capacity confirming to IS-2878 complete all as specifed and directed.
Supply and installation in repalcement of fire Extinguisher CO2 type 22.5 Ltrs capacity Trolley Mounted confirming to IS-2878 complete all as specifed and directed.
Flint India
M/s Adhikari construction co.
M/s VINOD KUMAR SHARMA
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .