UNIVERSITY ENGINEER
GOA UNIVERSITY TALEIGAO PLATEAU GOA
SETTING-UP OF AN 11KV SUBSTATION NEAR SPAS BUILDING AND AN 11KV SUBSTATION NEAR FACULTY BLOCK E ALONG WITH CONSTRUCTION OF BUILDING FOR 33KV SUBSTATION AND CONSTRUCTION OF SERVICE ROADS NEAR SPAS BUILDING IN G.U CAMPUS
2024_GU_16965_1
GU/9/2024-2025/Engg and Tech Div/145
Open Tender
Miscellaneous Works
Item Rate
270 days
GOA UNIVERSITY TALEIGAO PLATEAU GOA
PLEASE REFER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹15,000
₹6.3 L
14 Feb 2025
28 Aug 2024
17 Sept 2024
28 Aug 2024
16 Sept 2024
29 Aug 2024
Amount
Earthwork in excavation by mechanical means ( hydraulic excavator/manual means in foundation trenches drain ( not exceeding 1.5 m in width or 10 sq.m on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m.
b)All types of Ordinary rock including all types of laterite rock, blasting prohibited
Refilling the foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50M and all lifts and disposal of surplus earth as directed by Engineer in charge
Supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing, complete.
b) Moorum
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.
Laterite masonry in neatly dressed stones of size as specified in cement mortar 1:4 ( 1cement : 4 coarse sand ) in foundation and basement
Pre-cast cement concrete solid block masonry of compressive strength 70 kg / cm2 in cement mortar 1:4 (1 cement : 4 corase sand ) in all sizes in superstructure from floor one level upto floor V level ( size of block 30x23x15)
Providing & laying cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded granitic or basaltic stone aggrt. 40 mm. nominal size) excluding cost of centering, shuttering and finishing in:(a) All works upto plinth level
a)all works up to plinth level
Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in:
A) all works up to plinth level
Providing & laying damp proof course 50 mmthick with cement concrete 1:2:4 (1 cement: 2coarse sand: 4 graded stone agg. 20 mm nominalsize).
Providing and laying in position machinebatched concrete (BMC), machine mixed anmachine vibrated design mix cement concrete ofspecified grade for reinforced cement concretework including pumping of concrete to the siteof laying but excluding the cost of centering ,shuttering, finishing and reinforcementincluding admixtures in recommendedproportions as per IS 9103 to accelerate, retardsetting of concrete, improve workability withoutimpairing the strength and durability as per thedirection of the Engineer-in-charge. M-30 gradeof reinforced cement conrete by using 420 kg ofcement per cu.m. of concrete. All works upto floor V level.
Providing and laying in position ready mixedconcrete (RMC) with usage of OrdinaryPortland Cement manufactured in fully automatic batching plant and transported to siteof work in transit mixer for a lead upto 10kmshaving continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C., from the transit mixer to the site of laying, excluding the cost of centering,shuttering, finishing and reinforcement including the cost of admixtures in recommended porportions as per IS : 9103 to accelerate/retard setting of concrete, improve workability without imparing strength and durability as per the directions of the engineerin- charge. All works upto floor V level
v)M-30grade of concrete
Centering and shuttering including strutting , propping & removal of forms for
I) Foundations, Footings, Bases for columns
II)Vertical surfaces such as retaing walls, returnwalls, Partitions, walls (any thickness) includingattached Pilasters, Buttresses, Plinth and stringcourses, Fillets and the like
III) Columns , piers, pillars, abutments, posts and struts ( square, rectangle or polygon in plan )
iv) sides / soffits of beams, beam haunchings, cantilevers, girders, bressumers and lintels plinth beams not exceeding 1M in depth
XIII) Suspended floors , roof landings, shelves & their supports,chajjas
Providing corrosion resistant steel CRS-50 bars of (SAIL, TATA, VIZAG, JSW SteelLtd.)(Confirming to IS 1786 if 1985) for RCCwork including bending, binding & placing inposition in all the floors along with factory made precaste concrete cover blocks of specified s izeswhose compressive strengthis not less than thatof surrounding concrete in the structuralmember .
Kotah stone slab flooring over 20 mm (average) thick base laid over & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)
a) 20 mm thick.
b) Kotah stone slab flooring over 25 mm thick in risers of steps, skirtings, dado & pillars laid on 12mm (average) thick cement mortor 1:3 (1 cement : 3 coarse sand) & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete.
Providing woodwork in frames of doors, windows, clerestory windows trusses & other frames wrought framed and fixed in position.
c) first class matti wood
Providing and fixing 38 mm thick panelledglazed or panelled and glazed shutters for doors,windows and clerestory window includinganodized aluminium butt hinges with necessaryscrews:
a) Second class Indian teak wood
Extra for providing vision panel not exceedin0.1 sq.m. in all types of flush doors (cost of glassexcluded)
a Rectangular or square Unit: SQ.M. door area
Providing & fixing anodised aluminium sliding door bolt anodised transparent or dyed required colour and shade with bolts, nuts and screws etc. complete ( ISI mark, Heavy )
Providing and fixing aluminium tower bolt (barrel type) anodised or dyed to required colour or shade with screws etc complete.
( ISI mark, Heavy )
Providing and fixing aluminium handle anodized or dyed to required colour or shade with screws etc. ( ISI mark, Round, Heavy)
Providing flat iron hold fast 40 cm including fixing to frame with 10mm dia bolts , nuts and wooden plugs and embedded in cement concrete blocks 30 x 10 x 15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 stone aggregate 20 mm nominal size
b) 40 x3 mm flat iron hold fast, 15 cm long
Providing and fixing M.S grill of required pattern in wooden frames of windows etc with M.S flats square or round bars with round headed bolts and nuts or by screws.
a) Plain grill
Providing & fixing aluminium shutters( Jindal Make) as per design including transportation, scaffolding and handling etc, complete. , Adjustable louvered windows using 25 mm x 50 mm tube with exhaust provision with 3.5 mm pin headed glass complete.
Extra for powder coating with pure polyester powder of shade of required colour on the aluminium section
12mm cement plaster 1:4 ( 1 cement : 4 coarse sand )
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1;5 ( 1cement : 5 coarse sand ) and top layer 6 mm thick with cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with sponge
6mm cement plaster to ceiling 1:3 ( 1cement : 3 fine sand)
Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacture, over the plastered wall surface to prepare the surface even and smooth complete.
Extra for providing and mixing water proofing material proportion recommended by the manufacturers
a) 12mm cement plaster 1:3 ( 1cement: 3 sand)
Applying priming coat with ready mixed primer of approved brand and manufacture on WOOD WORK complete
Painting two or more coats (excluding priming coat ) with superior quality ready mixed paint(satin finish) for WOOD WORK of approved brand & manufacture in all shades on NEW WORK to give an even shade
Painting three or more coats with acrylic exterior paint of approved brand and manufacture ( such as weather shield, Apex) including applying one coat of cement primer and one coat of surface treatment etc. complete
Applying one coat of cement primer of approved brand and manufacture on wall surface.
Wall painting ( two or more coats) with plastic emulsion paint of approved brand and manufacture including a priming coat on NEW WORK to give an even shade
Applying one or more coat of corroseal ZR epoxy zinc rich primer( mixed corroseal ZR based and curing agent in prescribed proportion ( 1:1) by volume and allow it to remain for 10 minutes
Painting two or more coats of Anti-corrosive Epoxy Paint on Steel Work of approved brand on New work to give an even shade.( Asian Paints / Surfa Coat)
Neat cement punning
Providing anti – termite treatment to buildingsconforming to I.S.S. 6113 part II 1971 (revised)including adopting precautions for healthhazards and safety measures as required therein with the cost of all materials, chemicals, plants,equipments required for the treatment and furnishing a guarantee for a minimum period of 10 years from the date of completion including eradicating any infestation of termite free of cost during the guaranty period complete. (Thepayment will be made on plinth of the building.
a)Pre-construction
Providing and fixing rigid PVC S.W.R. (soil, waste & rain water drainage pipes of approved including lubricant etc. complete (single/double) socketed:
a) 110 mm dia
Providing and fixing square-mouth S.W. gully trap grade ‘A’ complete with c.i. grating brick masonry chamber and water tight C.I. cover with frame of 300 x 300 mm size (inside the weight of cover to be not less than 4.53 kg). And frame to be not less than 2.72 kg as per standard design :
b) 150 x 100 mm size –P or S type
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) (Square Hollow Section (SHS) IS4923 /Rectangular Hollow Section (RHS) IS4923/ Circular Hollow Section (CHS) IS1161 closed Structural Steel of (SAIL, TATA. VIZAG, JSW ,APOLLO Steel Ltd.) make (Min Yeild Stress 310 Mpa)) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Steel work welded ( SAIL, TATA, VIZAG & using electrodes of AdOr make only) in built up sections trusses and framed work including cutting, hoisting, fixing in position with anchor fasteners ( Hilti HST) and applying zinc chromite primer
b) In tees, angles ,flats and channels as per the design
Providing and fixing colour coated galvuliumroofing sheets of 0.5mm thickness including allthe accessories (TATA / JSW make) but excluding thecost of purlins, rafters, trusses, flashings etc.complete as per the directions of the Engineer incharge.
Providing and fixing colour coated Galvulium Flashings of 0.5 mm thickness( TATA / JSW Make) in - corners,ridges,valleys, gable end and trims Girth up to 610 mm including all the accessories complete as per the directions of the Engineer in Charge.
Providing and fixing 0.50mm thick colour coated galvulium Rain Water gutter with machine cut and press bend in as per approved design in line level along with gutter strip, silicon sealant, SDS, etc.complete.
Extra for carriage of R.M.C. beyond the 10 kms. For 15 kms
12mm thick plain cement mortar bands in cement mortar 1:4 (1 cement: 4 fine sand)1 meter long, 1 cm wide
Construction of embankement with approved material obtained from borrowpits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300-2 as per MORTH specification 305
Supplying of laterite stone soling of size 150-200 mm size and murrum having P.I. Value not more than 6 and laying including packing with smaller stones and consolidation with power road roller including spreading, watering and consolidation of binding material etc.(Measurements shall be considered on finished item) .
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : (b)All types of Ordinary rock including all types of laterite rock, blasting prohibited
Providing and laying 50mm(consolidated thickness)full grout using granitic or basaltic stone of specified grading at 6.00 cu.m. per 100 sq.m. grouting with hot bitumen straight run bitumen(or with such bituminous material of grade and type as specified by the Engineer-in-Charge)at 5.0kg. per sq. m. binding with key aggregate of granitic or basaltic stone of specified grading at 1.5 cu.m. per 100 sq.m. including Providing and laying seal coat sealing the voids in a bituminious surface laid with F.E loader with 1 Cu.m. bucket capacity to the specified levels, grade and cross fall using Type A seal coat with 0.98 kg/sqm of bitumen of grade as per MoRT&H specifications clause 513.
Providing and laying bituminous macadam with 40- 60 TPH hot mix plant producing an average output of 50 tonnes per hour using crushed aggregates of specified grading premixed with bituminous binder to the specified percentage of total mix , transported to site, with all leads laid over a previously prepared surface with sensor paver finisher to the required grade, level and alignment and rolled with smoth wheeled roller and vibratory roller to achieve the desired compaction, using antistripping agent complete as per MoRT&H Specifications Clause 504
Grade-II (19mm nominal size)@ 4% of Bitumen-mix (a)Antistripping agent @ 0.5% of bitumen content
Providing and laying 30 mm thick Bituminious/Asphaltic concrete with 40-60 batch type HMP producing an average output of 50 tonnes per hour using crushed aggregates of specified gradings Premixed with bituminious binder at 6.0 % by weight of total mix and filler incl. Providing Antistripping agent.@ 0.50% of bitumen content of, transpoting the hotmix to work site with all leads and applying a tack coat @f 2.00 kg/10sq.m. with hot bitumen of 80/100 and laying with hydrostatic/hydraulic power finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory or tandem rollers to achieve the desired compaction as per MORT&H specifications clause 509 and 503 a) Antistripping agent @0.5% of bitumen content
Providing and applying tack coat with bitumen grade of 80/100 or bitumen emulsion using pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom as per MoRT&H specifications clause 503. Bitumen 80/100@ 0.375 kg/sq.m
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC : 35. The finished surface to be level uniform and free from streaks and holes as per MORTH Specification 803
Raising side shoulders with hard murrum including spreading watering and consolidation using murrum from cut spoils
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) with modular switch, modular plates,suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
(f) Group C -- with Cat B Modular Accessories
Wiring for group controlled light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing suitable size modular GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/ 6 A modular switch connection painting etc. as required.
(b) Cat B
Supply and erecting fan hook box ( 100 mm diameter or equivalent square size, 75mm deep) fabricated out of 16 SWG sheet steel with 10 m round bar hook bounded to RCC steel upto 50 mm length protruding on each side of the box, including painting with 2 coats of red oxide, complete as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit(heavy) of appropriate size as required.
(b)2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm Conduit)
(c) 2 x 4 sq.mm + 1 x 4 sq.mm earthwire (20mm Conduit)
Supplying and fixing of following sizes of rigid PVC conduit alongwith accessories in surface(medium)/recess(heavy) including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
(b) Cat B
Supplying and fixing following way TPN sheet steel, double door, Verticle type MCB distribution board 415 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator)interconnection between incomer MCB and busbars of following ways (but without MCBs as required)
(e) 8 way (8+24), double door, Vertical type, Cat B
Supplying and fixing B series SP MCB 240V, suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required"
(c )5A TO 32A, Cat B
Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry enclosure with CI/RCC cover having locking/lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size 1.0x1.0x 3.0 mtrs(min) and disposal of excavated soil. c)Watering GI pipe, 20 mm Class B, with funnel as per specs. d) Charcoal/salt as per specs ( paid seperately). e) Refilling the pit of size 1.0x1.0x 3.0 mtrs(min) with soft black agriculture soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. g)watering arrangement (plumbing will be paid seperately).
(b) In rocky strata
Extra for using salt and charcoal for GI or Copper plate earth electrode as required (96kgs of charcoal and 5kgs of salt)
Earthing with GI earth pipe 2 mts long 40 mm dia medium class with ISI mark, of approved brands including accessories and providing masonry enclosure with CI/RCC cover having locking /Lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size not less than 1.0x1.0x 2.0 mtrs(min) and disposal of excavated soil. b) Class B GI pipe, 40mm diameter as per specifications. c) Charcoal/salt as per specs ( paid separately). d) Refilling the pit of size not less than 1.0x1.0x 2.0 mtrs(min) with soft black soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe . g)watering arrangement(plumbing will be paid separately).
(b) In rocky strata
Extra for using salt and charcoal for pipe earth electrode as required( 65 Kgs of Charcoal and 5 Kgs of Salt).
Supply of 4 core armoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size.
4 Core 6 sq.mm
Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.
(3) 4 x 6 Sq. mm.
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made complete
Supply Installation Testing Commissioning of Main LT panel Single front, compartmentalized, ,indoor, Construction: Structural members – 2.5mm , doors – 1.6mm CRCA, covers & partitions – 1.6mm CRCA, base frame –75x75x5mm CRCA, Component Mounting Plates – 2mm CRCA, Gland Plates – 2mm CRCA, Gaskets: Soft EPDM rubber gaskets, completely derusted, chemically treated in 7 tank process Painting/ Powder coating in RAL 7032 Siemens Grey, Cable Entry – Incomer & Outgoing: bottom:, Degree of Protection – IP52, some spare compartments Applicable Standard: IS:8623-1994, Insulation Volts: 660V, 50-60Hz, System Volts: 415V, 50Hz, 3-phase, 4-wire, Ambient Temperature: 40oC, Relative Humidity: 90%
Busbars 2 sets, Material: Aluminium alloy 63401-WP to IS:5082-1998, four pole, Continuous current rating: 2000A: Bus bar Supports :Non Hygroscopic SMC Supports , Isc = 50kA/1 sec
INCOMER1- to Bus Bar1, 1 no for 1000KVA Transformer, equipped with 2000A 4P EDO ACB, 50KA,microprocessor based Over current, Short circuit and Earth fault relay, 240V controls 4NO+4NC aux contacts and 1 no. fault sig contact, digital multifunction meter read volts,amps,frequency,pf, Maximum Demand, 96x96, class 1.0, aux, supply 90-270VAC, with RS 485 port , 2000/5A 15VA CT suitable for connecting to APFCR. Aluminium bus bar links suitable for terminating incoming power cables of size 5//3.5Cx300 mm2
INCOMER2 to BusBar2- 1 no. for DG, equipped with 1000A 4P EDO microprocrssor based ACB with AMF controls, 50KA, with Over current, Short circuit and Earth fault release, 240VAC controls,4NO+4NC aux contacts, 1no fault sig. contact. Microprocessor based earth leakage relay 30-300mA (18steps) sensitivity. 85-275VAC aux, supply, 2 co contacts with tape wound rectangular CBCT.Trip-Neutral-close switch, momentary, spring return to normal, 25A, 1no+1nc per way. 1no 6A single pole control MCB, 10KA C curve. Restrictted earth fault realy with potential free contact to trip the DG. Supply indicating led R Y B lamps, ON indication RED lamp, Off indicating led lamp Green, Trip indicating led lamp. Digital multifunction meter to read volts,amps,frequency, pf, KVA, KWH, KVAH, KVRAH 96x96 with rectangular polyamide CT class 1.0. Aux, supply 90-270VAC, without RS 485 port. Aluminium bus bar links suitable for terminating incoming power cables of size 3//3.5Cx400 mm2
Bus Coupler, 1 no for above two bus bars with 1000A 4P EDO ACB, 50KA, microprocessor based Over current, Short circuit and Earth fault relay, 240V controls 4NO+4NC aux contacts and 1 no. fault sig contact, aux, supply 90-270VAC, with RS 485 port, providing necessary signals and cable to start/stop the DG when transformer ACB is OFF with settable timings, with potential free contact to trip the transformer breaker, and interlocking with DG ACB so that the bus coupler can be made ON only when DG ACB is OFF.
Outgoings from bus bars1
Outgoing1 from bus bar1 630A thermal magnetic based 4P MCCB with 12 stage APFC relay with CTs with 2000A 50KA bus bars with outgoings 2 sets of 200A TP fuses with 100KVAR app type capacitor, 2 sets 150A TP fuses with 50KVAR APP type capacitors. 1 set of 100A TPN Fuses with 25KVAR APP type capacitors, 2 sets of 100A Fuses with 12.5KVAR APP type capacitors
Outgoing2 -from bus bar1, 1 no equipped with 1200A 4P EDO ACB, 50KA,microprocessor based Over current, Short circuit and Earth fault relay, 240V controls 4NO+4NC aux contacts and 1 no. fault sig contact, digital multifunction meter read volts,amps,frequency,pf,96x96, class 1.0, aux, supply 90-270VAC, without RS 485 port. Digital multifunction meter to read volts,amps,frequency,pf,KW & KWH ,9x96,class 1.0; aux. supply 90-270VAC , with RS485 port , aluminium bus bar links suitable for terminating outgoing power cables of size 5//3.5Cx300 mm2
Outgoing3 -from bus bar1, 1 no equipped with 100A 4P fixed type thermo magnetic 36KA MCCB with overload and short circuit protection with Extended operating rotary handle for mccb with door interlock for RTCC indoor panel controller
Outgoings from bus bars2
Outgoing1 from bus bar2 1 no equipped with1000A 4P EDO ACB, 50KA,microprocessor based Over current, Short circuit and Earth fault relay, 240V controls 4NO+4NC aux contacts and 1 no. fault sig contact, digital multifunction meter to read volts,amps,frequency,pf,96x96, class 1.0, aux, supply 90-270VAC, without RS 485 port, aluminium bus bar links suitable for terminating outgoing power cables each of size 4//3.5Cx300 mm2
Outgoing2 from bus bar2 100A 4P MCCB, 36KAfixed type Thermal magnetic type with overload and short circuit protection with Extended operating rotary handle for mccb with door interlock spreader terminal for mccb 1co auxiliary +1 co fault indicating contact for mccb, 6A single pole control mcb, C curve, 10 KA , 15A disconnecting type neural link, ON indicating lamp, red, LED type, 240VAC , OFF indicating lamp, green , LED type , 240 VAC , outgoing power cables each of size 3.5Cx50 mm2
Main LT Panel as above
Design, Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 1000 kVA, Mineral oil immersed and naturally cooled outdoor type, Copper wound ,without gas cushioning ,hermetically Sealed transformer, delta/star connected additional neutral brought out on load side, with incomer and outgoing cable end boxes, temperature rise should not exceed 45℃ by thermometer in oil and 50℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with on load tap changer) on load +5 to -15 in steps of 2.5%, with standard accessories complete with test certificate with losses below 2790 Watts at 50% load, 7700 Watts at 100% load as per IS:1180 (part 1) : 2014 with necessary permissions of Electrical Inspector, as per specification no SS- TR-SL
Design, Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 1500 kVA, Mineral oil immersed and naturally cooled outdoor type, Copper wound ,without gas cushioning ,hermetically Sealed transformer, delta/star connected additional neutral brought out on load side, with incomer and outgoing cable end boxes, temperature rise should not exceed 45℃ by thermometer in oil and 50℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with on load tap changer) on load +5 to -15 in steps of 2.5%, with standard accessories complete with test certificate with losses below 2790 Watts at 50% load, 7700 Watts at 100% load as per IS:1180 (part 1) : 2014 with necessary permissions of Electrical Inspector, as per specification no SS- TR-SL
Design, Supplying, installing, testing & commissioning indoor double door cubicle type panel fabricated in CRCA sheets. The panel shall be powder coated and it will be totally dust and Vermin proof with busbar, wiring and stand. It will consists of: 2000A 4P EDO Microprocessor ACB 50kA: 1 No RYB Indicator: 1 Set
Supply of armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I),IS:7098(Part I) with latest amendments of following size.
(10) 3 1/2cx300 sq.mm
Supply of armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I),IS:7098(Part I) with latest amendments of following size.
(10) 3 1/2cx400 sq.mm
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of exceeding 120 sq.mm but not exceeding 400 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required.
b) In rocky strata
Laying of one number additional PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 120 sq.mm but not exceeding 400sqmm direct in ground in the same trench in one tier horizontal formation including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick, protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required.
b) In rocky strata
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 400 sq.mm in the existing RCC/HUME/STONEWARE Metal pipe, etc. complete as required
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 400 sq.mm in the existing masonry open duct, etc. complete as required
Supplying and making cable end terminations with brass compression gland and copper lugs for following sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.
(11) 3 1/2 x 300 Sq. mm.
Supplying and making cable end terminations with brass compression gland and copper lugs for following sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.
(12) 3 1/2 x 400 Sq. mm.
Steel work in single sections (SAIL, TATA. VIZAG & using electrodes of Ador or ES4B or Deh Secheron make only) including cutting, hoisting fixing in position and applying a priming coat of red lead paint.
a ) In R.S. joists, channels, angles, tees
b) In flats of all sizes
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working up to 22 kV supply complete.
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes)
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 having 2 mm thickness up to 3.3 kV
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652 – 2006 having 2.5 mm thickness up to 11 Kv
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class C insulation conforming to IS: 15652 – 2006 tested having 3mm thickness up to 33 kV
Supplying & installing SMC chequered plates of size 4ft x 2ft, hot press moulded from advanced composites of plastics namely sheet moulding compound of thickness 2.5 mm with insulation level up to 22 kV and fixing it to substation floor with SR-998 adhesive along with 5 mm thick E.P. foam complete.
Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width chain link wire mesh (jali) with angle iron frame work erected in CC foundation and painted complete as required
Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation, and painted complete as required
Supplying and erecting 50 x 50 x 6 mm angle iron as corner support 2m long fixed at the middle of the fencing frame and the other side inclined at 30 degree angle, in cement concrete foundation of 15 x 15 x 40 cm complete duly painted with one coat of red oxide and two coats aluminium paint complete.
Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosure with CI/RCC cover having locking/Lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size 1.0x1.0x 3.0 mtrs(min) and disposal of excavated soil. b)Watering GI pipe, 20mm, Class B, with funnel as per specs. c)Charcoal/salt as per specs (paid separately). d) Refilling the pit of size 1.0x1.0x 3.0mtrs(min) with soft black agriculture soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe.g)watering arrangement(plumbing will be paid separately).
(b) In rocky strata
Supplying and laying 25 mm x 6 mm GI strip at 0.5 m below ground as strip earth electrode including soldering etc. as required
Supplying and laying 25 mm x 5 mm copper strip in 40 mm dia GI pipe from earth electrode as required
Supplying and fixing suitable size modular GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 15/16 A and 5/6 A modular socket outlet modular socket outlet and 15/16 A modular switch connection painting etc. as required. (b) Cat B
Supplying and erecting of 48 inch (1200mm sweep) ceiling fan, double ball bearing type complete with all accessories
(b) Cat B
Supplying and erecting slotted angles, frames, strips, etc. for fixing of trays complete with bending, cutting, drilling and welding complete erected at the position with necessary materials such as nut bolts,etc duly painted with one coat of red oxide and two coats of enamel paint to match the structures or as per directions
Supplying and fixing 40 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.
(f) SP, Cat B
Supplying and fixing 63 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.
(j) TPN Cat B
Supply and erecting of 9 inch (225 mm sweep) exhaust fan with double ball bearing 1400 rpm, complete with all accessories.
(a) Cat A
Supplying and erecting integrated LED flood light fitting Max. 50W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 5000 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2
Supplying & erecting LED 40W tube light fitting (4 feet), 5700K, with CRCA housing, heat sink, with industrial grade heavy duty driver complete Havels Cat stout mini 1200bs 40w led 865 spcwh OR Wipro cat no LL24-541-XXX-57-CD (including lamp).
Supply and fixing of cable route marker 15 cms diameter of GI plate 6mm thick with inscription thereon bolted or welded to 25mm x 25mmx 5mm angle iron 60 cms long and fixing the same in ground with PCC etc complete as required.
Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm in the existing masonry open duct, etc. complete as required
Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete.
Supply of following size of 3 core, HV, 11 KV grade, ISI mark, XLPE cable with stranded compact circular aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated, insulation screned with extruded semiconducting compound in combination with copper tape(0.3 KA for 1Sec.) cores laid off,inner sheath of PVC tape,galvanised steel flat strip armoured and overall PVC sheathed cable conforming to IS:7098(Part II) with latest amendments.
3 Core 95 sq.mm
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of grade exceeding 1.1 KV but not exceeding 11 KV grade of size not exceeding 120 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed lenghtwise on top of cable all over the run and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required.
(b) Rocky strata
Supplying and making Indoor cable end termination with heat shrinkable kit for following sizes of PVC insulated PVC sheathed/XLPE aluminium conductor cable upto 11 KV grade, complete as required.
(b) 11 KV, 3 Core x 50 - 95 sq.mm
Clearing grass and removal of rubbish upto a distance of 50 m outside the periphery of the area
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means in foundation pipeline trenches drain (not exceeding 1.5 m in width or 10 sq.m. on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m.
b) All types of Ordinary rock including all types of laterite rock, blasting prohibited
Providing and laying in position (1:2:4) reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement. (1 cement:2 coarse sand:4 graded stone agg 20mm nominal size)
All works upto plinth level
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 500 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 81.90 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 690 Ltr etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG For all the Engines, the emission standards/norms shall meet applicable pollution control board norms as amended by Government.
Design, Supply, fabrication, transportation, hoisting, erection & painting of common MS stack structure / MS support for 500KVA, DG Sets Exhaust pipe including exhaust pipe including mineral wool insulation, cladding covered with wire mesh, aluminium sheet , SS expansion bellows etc , (SAIL, TATA. VIZAG) channel angles, plates, flat, beam sheet, foundation with excavation , rcc etc. as per design including anchor bolts / dash fasteners/ bolts nuts/hardware etc. as required complete with painting with one coat of primer and two coats of synthetic enamel paint as per approved shade for exhaust stack. Liability certificate for the structural work is to be provided from reputed structural consultant. Also approval of the completed work is to obtained from Pollution Control Board, Goa.
Supply installation of 999 litres Diesel tank as per standard requirement including all connections
Premier Builders Goa Pvt. Ltd. (BID ID -37637)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .