Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹73.0 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest bidder | |
| 2 | L2₹75.0 L+₹1.1 L (1.44%)Rejected-Finance FLAT NO 107 C WING SKYWAYS SERENO LOHEGAON PUNE 411 047 | PUNE | PUNE | MAHARASHTRA | 411047 | L2 | Rejected-Finance Rejected being not lowest bidder | |
| 3 | L3₹77.0 L+₹3.0 L (4.07%)Rejected-Finance | L3 | Rejected-Finance Rejected being not lowest bidder | |
| 4 | L4₹1.1 Cr+₹34.7 L (46.9%)Rejected-Finance SHOP NO 18 1ST FLOOR NORTH LAND BUILDING SECTOR NO 1 BACK SIDE OF BANK OF MAHARASHTRA INDRAYANI NAGAR BHOSARI PUNE 411039 | PUNE | MAHARASHTRA | 411039 | L4 | Rejected-Finance Rejected being not lowest bidder |
Tender Value
₹80.9 L
EMD Value
₹1.5 L
Closing Date
24 Aug 2022, 6:00 pmClosed
CWE KIRKEE
Headquarters CWE Kirkee, Military Engineer Services, Range Hills Road, Kirkee, Pune-411003
PROVN OF FIVE GARAGES AND TWO STORAGE ROOMS FOR HOUSING TRG AND MT EQPT IN TRG AREA OF FCBRNP (SPL WK) (CAT A WKS AND B WKS) UNDER GE (CME) KIRKEE
2022_MES_539508_1
CWE/KKE/TOKEN-14 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
KIRKEE
AS PER TENDER DOCUMENTS
5 documents required · 5 mandatory
₹1,000
Yes
GE CME KIRKEE
₹1.5 L
Yes
2 Sept 2022
20 Jul 2022
26 Aug 2022
20 Jul 2022
24 Aug 2022
10 Aug 2022
21 Jul 2022 - 28 Jul 2022
Amount
Surface dressing n exc 15 cm deep in any type of soil complete all as specified and directed by Engr-in-charge.
Excavating over areas, n exc 1.5 m deep in Soft/disintegrated rock and getting out complete as specified and directed by Engr-in-charge.
Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth; for foundation, or for shafts, wells, cesspits, manholes, pier holes, etc. and making good surface for laying /removing of cable all as specified and directed by Engr in charge for Soft/loose soil all as specified and directed by Engr in charge
All as per item No 3 above but for Hard/dense soil all as specified and directed by Engr in charge
All as per item No 3 above but for Soft/disintegrated rock all as specified and directed by Engr in charge .
Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth; for foundation, or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out in hard rock complete as specified and directed by Engr in charge
Excavation in trenches exc 1.5m wide and exc 1.5m in depth upto 3.00 m for foundation, or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out in hard rock complete as specified and directed by Engr in charge
Removing excavated surplus soil nexc 50m and depositing where directed at a levelnot exc 1.5 m above the starting point all as specified and directed by Engr in charge
M&L for moorum filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering all as specified and directed by Engr in charge
Returning, filling in including spreading, leveling, watering & welling ramming in layers n.exc 25cm th all as specified and directed by Engr in charge.
M&L for PCC 1:4:8 type D2 (40mm Graded stone aggregate) as in foundations filling and mass concrete, plinth block of LT poles etc all as specified and directed by Engr in charge.
M & L for RCC M-25 (Design mix) using 20mm graded stone aggregate as in column footing plinth beam tie beams and column up to plinth beam all as specified and directed by Engr in charge.
M & L for RCC M-25 (Design mix) using 20mm graded stone aggregate as in column as in column above top of plinth beam all as specified and directed by Engr in charge.
M&L RCC M-25 (Design mix) as in roof beam,lintel beam etc complete all as specified and directed by Engr in charge.
M&L RCC M-25 (Design mix) as in roof Slabs supported on walls,beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engr in charge.
M & L for Form work to sides of foundation / base of columns plinth beams and similar work with fair finished surface all as specified and directed by Engr in charge.
M & L for Form work to sides of columns and similar work with fair finished surface all as specified and directed by Engr in charge.
M & L for Form work to sides of roof beam, lintel beam & cantilevers and similar work with fair finished surface all as specified and directed by Engr in charge.
M & L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete as specified and directed by Engr in charge.
M&L Stone sett flooring with stone setts of size 200 to 250mm long,150 to 200mm wide and 150mm deep and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush complete as specified and directed by Engr in charge.
M&L 150 mm thick sub base cement concrete type B-2 1:2:4 using 40 mm graded stone agrregate complete as specified and directed by Engr in charge.
M&L for TMT bars 6 to 8 mm dia and over cut to length, bent to shape required including cranking, hooking ends, and binding with mild steel wire (annealed) not less than 0.9 mm dia conforming to Fe 400 or 410 S all as specified and directed by Engr in charge.
M&L for TMT bars 10 mm dia and over cut to length, bent to shape required including cranking, hooking ends, and binding with mild steel wire (annealed) not less than 0.9 mm dia conforming to Fe 400 or 410 S complete as specified and directed.
M&L Brick work with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar (1:6) with modular bricks all as specified and directed by Engr in charge.
M&L for PCC 1:3:6 type C1, using 20mm graded stone aggregate as in coping all as specified and directed by Engr in charge.
M&L for PCC type 1:2:4 using 20mm graded stone aggregate as in surface channel and drain average 50mm thick all as specified and directed by Engr in charge.
M & L Rendering 10 mm thick in cement mortar (1:4) mixed with liquid water proofing compound, on brick or concrete surfaces, trowelled to even and smooth finish without using extra cement with provide 300 mm wide chicken wire mesh at the junction of RCC and brick work all as specified and directed by Engr in charge. (Note :- liquid water proofing compound shall be measured and paid separately)
M & L for 15mm thick rendering in CM 1:6 on brick or concrete surfaces finishing even and smooth without using extra cement with provide 300 mm wide chicken wire mesh at the juction of RCC and brick work all as specified and directed by Engr in charge.
M & L rendering 5mm thick on concrete surface in CM 1:3 on ceiling, finished even & smooth with sagol all as specified and directed by Engr in charge.
Supply only liquid water proofing compound all as specified and directed by Engr in charge.
M & L Preparation of newly plastered surfaces of walls and apply two coats of oil bound distemper over a coat of primer white or tinted all as specified and directed by Engr in charge.
M & L for preparation of newly plastered surface and applying three coats of white wash on ceiling all as specified and directed by Engr in charge.
M & L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces all as specified and directed by Engr in charge.
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and pointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 15 mm thick screed bed in cement mortar 1:4 all as specified and directed by Engr in charge.
Machine cut kota stone slab, 15-20 mm (+ 2mm) thick as in risers of step, skirting, dado etc over and including 10 mm thick rendering in cement mortar 1:4 as base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including taking down cement plaster rubbing and polishing all as specified and directed by Engr in charge.
S & F on wall face unplasticised Rigid 110 mm PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipesall as specified and directed by Engr in charge.
S & F in110 mm PVC(SWR) Bend any radius all as specified and directed by Engr in charge.
S & F Mild steel bolts. purpose made. with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. Exc 30cm long complete all as specified and direted.
M&L Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. or other connecting plates etc complete all as specified and direted.
S & F Galvalume pre-coated profile Colour Roof sheets 0.50mm thick BMT with Zinc coating not less than 275gm/m² as in roofing fixed with including vertical/curved surface fixed with self tapping screw (60mm length 5mm dia G.I) with bitumen and G.I limpet washers or with G.I Limpet washer filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete(upto any pitch in horizontal/vertical or curved surface) excluding the cost of purlins, rafters and trusses and including cutting to size and shapes wherever required. bolts complete all as specified and as directed by Engineer- in Charge.
S & F Galvalume sheets 0.50mm thick with Zinc coating not less than 275gm/m² . ridges or hips of width 60cm over all width plain G.S. sheet fixed with polymer coated J. or L hooks,bolts and nuts 8mm dia. G.I. limpet and bitumen washers complete all as specified and as directed by Engineer- in Charge.
M&L for 75 mm thick cement concrete 1:3:6 type C1 using 20 mm graded stone aggregate in plinth protection finished even and smooth without using extra cement including necessary form work etc all as specified and directed by Engr in charge.
M & L Treating the bottom and sides of excavation at the rate of 5 ltrs of emulsion per Square metre of surface area with ATT all as specified and directed by Engr in charge.
M & L Treating the back fill in contact with foundation @ 7.5 ltr of emulsion per Sqm of vertical surface area with ATT all as specified and directed by Engr in charge.
M & L Treating the top surface of the filled earth @ 5.00 ltr of emulsion per Sqm of surface area with ATT all as specified and directed by Engr in charge.
M & L Treating the soil under the plinth protection at the rate of 5 ltrs of emulsion per Square metre of surface area with ATT all as specified and directed by Engr in charge.
M & L Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall all as specified and directed by Engr in charge.
M & L 40mm thick PCC 1:2:4, type B-O using 12.5 mm graded stone aggregate as in damp proof course to horizontal or vertical surfaces including necessary formwork all as specified and directed by Engr in charge.
M & L for water proofing treatment to RCC roof slab surface with 10 mm thick CM (1:3) screed bed over slab mixed with WPC @ 3% by weight of cement and applying one coat of oil based bituminious primer @ 0.20 kg/Sqm and laying 3 mm thick APP polymer modified membrane weighing not less than 3.5 kg/Sqm reinforced with non woven polyster weighing not less than 160 gm/sqm with thermal insulation and finally applying a coat of solar reflective bituminous aluminium paint @ 0.10 Kg/Sqm including removal of existing treatment, plaster etc complete and removing rubbish upto distance exc 50m and n.exc 250m all as specified and as directed by Engr in Charge.
M&L bitumen blown any grade applied hot, two coats to concrete surfaces @ 1.5 Kg/sqm per coat complete all as specified and directed by Engr in charge.
M&L for Providing precast cement concrete louvres and jallies, 25mm thick (mea sured solid), including all mould- ings, (Type C-0 1:3:6 12.5mm graded aggregate) set in CM 1:4 all as specified and directed by Engr in charge.
M&L Bitumastic gola, with 80/25 bitumen and coarse sand mixture. 1:3 by weight, 8cmx8cm at the junction of roofing to vertical surfaces all as specified and directed by Engr in charge.
M&L painting two coat of Synthetic enamel paint over one coat or red oxide zinc chrome. Primer on steel surface including preparation of new surface of any description, over 10 cm width or girth not otherwise described all as specified and directed by Engr in charge.
M& L Steel rolling shutters gear operated type 1.25 mm thick sheet with bevel gear box and crank handle , with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated,complete all as specified and directed by Engr in Charge.
S&F Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed.
S&F Ball bearing for rolling shutters complete all as specified and directed.
M&L Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface all as specified and directed by Engr in charge.
M&L 150 mm thick sub base cement concrete type D-2 1:4:8 using 40 mm graded stone agrregate all as specified and directed by Engr in charge.
M&L for PCC work in pavement/ hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre the thickness of concrete 25 cm or less all as specified and directed by Engr in charge.
M&L Finishing surface of concrete roads,pavements, by brooming all as specified and directed by Engr in charge.
M&L Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound all as specified and directed by Engr in charge.
S&F Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’complete all as specified and directed.
M&L for point wiring for light/fan/Bell with FRLSH cable 1.5 sqmm PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade in and incl not less than 2mm thick PVC casing/caping with all accessories and 1.50 sqmm green in colour PVC copper conductor cable for earth continuity connected to common earth dolly incl PVC box surface/ flush type with PVC sheet for mounting fittings such as switches, sockets, fan regulators, etc all as specified and directed by Engr in charge for one light/fan /bell point controlled by one switch & making good to disturbed surface of wall etc for the following :-
All as per item 64 above but for One light point controlled by one switch
All as per item 64 above but for One fan/exhaust fan point controlled by one switch and regulator
All as per item 64 above but for Socket outlet, three pin 5 Amps on the same board
All as per item 64 above but for Socket outlet, three pin, 5 Amp, independent
S & F switch piano, flush type, single pole one way 5 amps all as specified and directed by Engr in charge.
S & F socket outlet 2 in 1, 5 pin, 5 amps flush type all as specified and directed by Engr in charge.
S & F ceiling rose, 3 terminal PVC/polycarbonate isolated body, surface bakelite 65 x 50 mm, 3 terminal incl PVC square block all as specified and directed by Engr in charge.
S&F surface and wall mounted LED batten(LED tube light fitting 20W) with polycarbonate housing & integrated electronic driver alongwith LED tube 20 watt and 02 No PVC square blocks all as specified and directed by Engr in charge.
S&F building security LED light fitting 35 Watt , energy saving and environmental friendly long life LED fitting made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP 66 protection and impact resistance of IK 07 including suitable size bracket all as specified and directed by Engr in charge.
S & F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) all as specified and directed by Engr in charge.
S&F new generation energy saving LED Bulk Head fitting 10 Watt made up of Poly carbonate housing with diffuser.
M&L for sub main wiring with two run of 6 sqmm single core multi stranded PVC insulated and unsheathed copper conductor (red for phase and black for neutral) of grade 1100 volt FRLSH cable in and including 1100 volt electrical grade PVC Conduit of desired colour not less than1.2 mm thick and 25 mm wide & 6 sqmm copper conductor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth dolly all as specified and directed by Engr in charge
S&F MCB distribution board Double door SPN 240 volts 8 way with 200 amps rated bus bar and making good to disturbed surfaces of floors walls etc all as specified and directed by Engr in charge.
S&F MCB distribution board Double door SPN 240 volts 4 way with 200 amps rated bus bar and making good to disturbed surfaces of floors walls etcall as specified and directed by Engr in charge.
S & F MCB SP 6 to 32 Amps, 230 V AC all as specified and directed by Engr in charge.
S & F MCB SPN 40 to 63 Amps, 230 V, AC all as specified and directed by Engr in charge.
S & F MCB TPN 63 Amps,415 V, AC all as specified and directed by Engr in charge.
M&L for earthing complete with GI earth plate electrode 60x60cmx6mm thick burried directly in ground in earth pit not less than 2.25 mtr depth below normal ground level with top edge of the plate vertically to depth of not less than 1.5 mtr below ground level connected to & including GI lead 4 mm dia as earthing lead connecting to equipment by means of GI bolts & nuts etc with provision of charcoal and salt etc all as per electrical plate No-3 of SSR part-I 2009 including RCC cover and MS angle iron frame, watering with GI pipe 20 mm dia (medium grade) & MS funnel, concrete pit including excavation and earthwork in any strata and testing on completion etc. complete all as specified and directed by Engineer-in-charge.
S & L of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polythylene with smoooth internal and profiled external surface for non pressue under ground cable incl couplers & bends all as specified and directed by Engr in charge.
S & F LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection all as specified and directed by Engr in charge.
Supply, install and erect in true vertical position (or to be fixed in an inclined position as strut pole) steel tubular swaged poles complete with MS base plate of 6 mm thick of size 300 mm x 300 mm, finial taper plug, pole cap, bolts, nuts and washers and screwed pole made out of FRW MS tubing conforming to IS-2713 (Part-II) 1980 type 410-SP-31 ( 9 meters long ) pole including drilling of holes of required size, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embeded in concrete, etc all as specified and directed by Engr in charge. Note :- Earth work and PCC work will be measured and paid seperately.
S & F pole junction box sheet moulded compound (SMC) type with hinged door and locking arrangement of size 300 X 200 X 105 mm (internal ) comprising , 01 Nos MCB single pole of capacity 6 Amps 240 volts and four Nos terminal for loop in & loop out suitable for three phase street light system including nuts and bolts and connecting up complete, MS clamp fabricated from 25x3mm MS flat iron, nut bolts and washers etc all as specified and directed by Engr in charge.
S & F or passing through pipe, 1100 volts grade heavy duty , PVC insulated round 3 core 2.5 sqmm copper cable including electrical connection complete all as specified and directed by Engr-in-Charge.
S&F street light bracket made out of 40mm dia light grade GI pipe of 1.5 Mtr long bend to shape including pole bracket made out of MS strip 40x5 mm flat, nut bolts, washers etc and fixed on pole all as specified and directed by Engr in charge.
Supply , laying and testing cable XLPE insulated screened pvc bedded galvanised steel strip or wire armoured , electric power cables ( heavy duty) with stranded aluminium conductor 1100 volts grade in trenches/ passing through pipe/fixing on walls, floors etc incl connection with proper sizes lugs and gland, suitable clamp of cross sectional area 4 core 16 Sqmm all as specified and directed by Engr in charge.
All as per item 88 above but of the size 4 core 25 Sqmm all as specified and directed by Engr in charge.
All as per item 88 above but of the size 2 core 10 Sqmm all as specified and directed by Engr in charge. General Note applicable to all items :- The structural/ Arch drg included in the tender are for guidance purpose. Contractor will have to get these drg vetted for structural soundness from Govt Engg College/ Approved consultant and submit approved/vetted copy of these drgs to GE for his approval before commencement of work. Necessary charges for vetting to Govt Engg College/ Approved consultant shall be paid by the contractor and same shall be deemed to be included in rate quoted by the contractor.
Mukund Engineers and Contractors
sagar construction
ShreHari Civil Enginneering and Contractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .