Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹16.1 Cr 501 REGENT HEIGHTS 155 NSC BOSE ROAD TOLLYGUNGE KOLKATA 700040 WB | ₹16.1 Cr |
Tender Value
₹16.2 Cr
EMD Value
₹16.2 L
Closing Date
28 Jan 2025, 11:00 amClosed
Restoration and Upgradation including structural repair, retrofitting, demolition and re-construction of slab located at WRPC Staff Quarters, New D.N. Nagar, Andheri (West), Mumbai (Maharashtra)
NBCC/SBG-WEST/WRPC/MUM/NIT/2025/06
NBCC/SBG-WEST/WRPC/MUM/NIT/2025/06
Open Tender-Domestic
Civil Works - Buildings
Mumbai, Maharashtra
₹11,800
₹16.2 L
13 Jan 2025
13 Jan 2025
28 Jan 2025
28 Jan 2025
31 Jan 2025
NAME OF WORK: Renovation/ Conversion & Repair Works at WREB Staff Quarters at
D. N. Nagar, Andheri (West), Mumbai
SUMMARY OF COST OF CIVIL WORKS
S. No. Chapter Description/ Head of work Scheduled Items based
Non Scheduled Items
1 Dismentaling & Demolishing 43,41,000.26 58,075.00
2 Conservation of Building 7,30,620.00 -
3 New Technologies and Materials 1,05,38,568.00 1,60,71,125.49
4 Reinforced Cement Concrete 72,49,661.98 -
5 Brick Work 66,33,820.80 -
6 Wood & PVC Work 77,30,742.49 -
7 Steel Work 13,18,346.67 -
10 Finishing Work 57,60,193.37 -
12 Water Proofing 46,13,896.00 -
13 Exterior Finish Work 42,29,298.00 -
14 Barricading Work 14,78,126.00 -
15 Furniture & Furnishing Work - 67,08,000.00
TOTAL OF CIVIL WORKS CARRIED OVER TO GRAND
SUMMARY OF COSTS
GRAND TOTAL 9,42,02,094.46
GRAND TOTAL 9,42,02,094.46
NAME OF WORK: Renovation/ Conversion & Repair Works at WREB Staff Quarters at D. N. Nagar, Andheri (West), Mumbai
SCHEDULE OF QUANTITIES OF CIVIL WORKS
DSR 2023 Amount (Rs.)
S. No. Description Of Item Unit Approx. Qty. Rate (Rs.)
Ref. No. DSR NSR
SH-15: SH DISMANTLING AND DEMOLISHING
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and
disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats,
architrave, holdfasts etc. complete and stacking within 50 metres lead :
2.1 15.12.1 Of area 3 sq. metres and below each 360.00 367.20 1,32,192.00
2.2 15.12.2 Of area beyond 3 sq. metres each 60.00 502.75 30,165.00
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including
3 15.57 disposal of unserviceable material and stacking of serviceable material within 50 meters lead as directed sqm 518.77 56.35 29,232.84
by Engineer-in-charge.
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50
metres lead as per direction of Engineer - in - charge.
4.1 15.2.2 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) cum 606.40 1503.60 9,11,783.04
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal
of unserviceable material within 50 metres lead as per direction of Engineer - in- charge
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and
disposal of unserviceable material within 50 metres lead.
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50
7.1 15.23.1 For thickness of tiles 10 mm to 25 mm sqm 3480.30 73.40 2,55,454.02
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical
8 15.60 means, including loading, transporting, unloading to approved municipal dumping ground or as approved cum 2480.40 263.95 6,54,701.58
by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
Obtaining permission from local body for disposal of building rubbish / malba / similar unserviceable,
dismantled or waste materials to approved municipal dumping ground.
TOTAL OF DISMANTLING AND DEMOLISHING 43,41,000.26 58,075.00
SH-24: SH CONSERVATION OF BUILDINGS
Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure,
upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as
per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal &
vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase
10 24.2 system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for sqm 2160.00 338.25 7,30,620.00
execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The
scaffolding system shall be stiffened with bracings, runners, connecting with the building etc., wherever
required, if feasible, for inspection of work at required locations with essential safety features for the
workmen etc, complete as per directions and approval of Engineer-in-charge
SCHEDULE OF QUANTITIES OF CIVIL WORKS
DSR 2023 Amount (Rs.)
S. No. Description Of Item Unit Approx. Qty. Rate (Rs.)
Ref. No. DSR NSR
TOTAL OF CONSERVATION OF HERITAGE BUILDINGS 7,30,620.00 -
SH-26: SH NEW TECHNOLOGIES AND MATERIALS
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or
by standard power driven percussion type or of approved make including tapering of all edges, making
11 26.28 square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire
brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-
26.28.1 75mm average thickness sqm 2800.00 378.00 10,58,400.00
Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by
using alkaline chemical rust remover of approved make with paint brush and removing loose particles
after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry,
all complete as per direction of Engineer-In-Charge.
12.1 26.29.1 Bars upto 12 mm diameter metre 52000.00 8.23 4,27,960.00
12.2 26.29.2 Bars above 12 mm diameter metre 48000.00 16.45 7,89,600.00
Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a
minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars
13 26.30 for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of
approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In
13.1 26.30.1 Upto and including 12mm dia each 4800.00 141.20 6,77,760.00
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per
specifications and direction of Engineer-In-charge complete in all respect.
14.1 26.31.2 Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make sqm 2800.00 285.20 7,98,560.00
Providing, mixing and applying SBR polymer (of approved make @ minimum 2% by wt. of cement used)
modified plain/reinforced cement concrete for structural members having minimum characteristic
compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10mm
maximum size in proportion as per design criteria] with specified average thickness.
Note: Rates shall be for finished surface area of concrete and shall include the cost of labour, concrete
and appropriate approved Super Plasticiser for rendering concrete as flowable and SBR polymer but
shall exclude cost of reinforcement, bond coat, Shear Keys, centering and shuttering, strutting, propping
etc (Payment under this item shall be made only after proper wet curing has been done and surface has
been satisfactorily evaluated by sounding/tapping with a blunt metal instrument)
15.1 26.33.2 75mm thick in Grade M 25 with cement content not less than 330 kg per cum sqm 1620.00 853.70 13,82,994.00
Providing and injecting approved grout in proportion recommended by the manufacturer into
cracks/honey-comb area of concrete/ masonry by suitable gun/pump at required pressure including
16 26.35 cutting of nipples after curing etc. complete as per directions of Engineer-in Charge.
(The payment shall be made on the basis of actual weight of approved grout injected.)
16.1 26.35.3 Epoxy injection grout in concrete/RCC work of approved make kg 1800.00 553.40 9,96,120.00
Providing, erecting, maintaining and removing temporary protective screens made out of specified fabric
17 26.36 with all necessary fixing arrangement to ensure that it remains in position for the work duration as
required by the Engineer-in-charge.
SCHEDULE OF QUANTITIES OF CIVIL WORKS
DSR 2023 Amount (Rs.)
S. No. Description Of Item Unit Approx. Qty. Rate (Rs.)
Ref. No. DSR NSR
Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having
the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand
18 26.38 and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the
cost of centering and shuttering at edges and corners etc. as directed by Engineer in-Charge
Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall
be paid for separately. Payment under this item shall be made only after proper wet curing has been
done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument.
18.1 26.38.3 75mm thick in Grade M 25 with cement content not less than 330 kg per cum sqm 540.00 1628.85 8,79,579.00
Providing and inserting 12mm dia galvanised steel injection nipple in honey comb area and along crack
line including drilling of holes of required diametre (20mm to 30mm) up to depth from 30mm to 80mm at
19 26.39 required spacing and making the hole & crack dust free by blowing compressed air, sealing the distance each 3600.00 236.90 8,52,840.00
between injection nipple with adhesive chemical of approved make and allow it to cure complete as per
direction of Engineer-In-Charge.
Providing and fixing hard drawn steel wire fabric of size 75x25 mm mesh or other suitable size wire mesh
to be fixed & firmly anchored to the concrete surface by means of "L" shaped mild steel shear key welded
with existing reinforcement including the cost of materials, labour, tool & plants as approved by Engineer-
For Shear Connector/Ties/Stirrups: Supply and fixing of shear connectors/ties/ stirrups using rebars of
designated dia for column/beam /Shear walls etc at designed embedement length wherever required ,
including power drilling, cleaning of holes, then rebars should be inserted in holes that should be filled
with a hybrid rebarring chemical approved for diameter range from 8 mm to 28mm reinforcement bar as
per manufacturer's specification as per the direction of Engg In- charge. Drilling of hole should be done
upto provided embedment depth as per the design from manufacturer approved by EnC, followed by
cleaning with blow pump, wire brush and blow pump for 4 times, complete as per the manufacturer's
methodology. Cost of providing, cutting, bending of rebar shall be paid separately as per approved item.
Providing & fixing of additional reinforcement wherever the reinforcement loss is heavy (>30%) or
reinforcement lost is completely
22.1 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. kg 18000.00 107.85 19,41,300.00
Microconcrete with 6mm aggregates: Application of repair Micro-concrete of minimum M40 grade with
25% aggregate of 6mm dia. of approved make for making up lost section of concrete or for increasing of
cross section for thickness above 75 mm, after the application of bonding agents to ensure stability of
the concrete, followed by water curing for at least 7 days. The rates are inclusive of all materials, labor,
machinery, equipment, tools, tackles, etc., all complete.The microconcrete shall be free flow, self
compacting & should not require any vibratory compaction.Payment shall be made on the basis of
consumed dry material of microconcrete and payment for bonding agents will be done through separate
BOQ item. The cost chips is considered to included in the item rate.
SCHEDULE OF QUANTITIES OF CIVIL WORKS
DSR 2023 Amount (Rs.)
S. No. Description Of Item Unit Approx. Qty. Rate (Rs.)
Ref. No. DSR NSR
Microconcrete without aggregates: Application of repair Micro-concrete of minimum M40 grade of
approved make for Making up lost section of concrete for thickness less than 75 mm, after the application
of bonding agents to ensure stability of the concrete, followed by water curing for at least 7 days. The
23.1 NSR4 rates are inclusive of all materials, labor, machinery, equipment, tools, tackles, etc., all complete.The kg 10500.00 313.00 32,86,500.00
microconcrete shall be free flow, Self compacting & should not require any vibratory compaction.Payment
shall be made on the basis of consumed dry material of microconcrete and payment for bonding agents
will be done through separate BOQ item.
CARBON FIBER SHEETS FOR STRUCTURAL STRENGTHENING
Providing and wrapping uni-directional, high strength Carbon Fiber Sheets "Nitowrap-CWS' or equivalent.
The FRP fabric used shall be of zero degree unidirectional fibers having fiber density of 1.8 g/cc and
shall have tensile strength > 4900 MPa ; tensile modulus > 230 GPa and ultimate elongation of 2.1%. To
be applied, fixed over the distressed Columns/ Beams / Slabs. The columns/ Beam/ Slab surface is to be
24 NSR5 grind and cleaned, then applying levelling agent such as Nitomortar/ putty, priming agent and bonding
agent such as Nitowrap 30 Primer and Nitowrap 410 saturate of Fosroc as per manufacturer's
recommendations before wrapping the Carbon Fiber sheet. All surfaces shall be dry smooth and fee from
debris or loose material. Surfaces must be fully cured and free from coatings, im-pregnations or
Strengthening/ retrofitting of column/ beams using Carbon Fiber Jacketing as per drawing, design and
specifications including the cost of centering and shuttering as directed by Engineer in-Charge
Chicken Wire Mesh: Providing and fixing of chicken mesh with cement mortar and screws/nail in plaster
25 NSR6 work between concrete bend, lintels, column and brick work for avoid the cracks in finishing work. sqm 550.00 114.00 62,700.00
New External Plaster: Providing and applying new Pre mix and pre bagged ready made fibre reinfoced
cement plaster in 18-20 mm thickness in 2 coats including curing etc complete as per EIC instructions.
New Internal Plaster: Providing and applying new Pre mix and pre bagged ready made fibre reinfoced
cement plaster in 12-15 mm thickness including curing etc complete as per EIC instructions.
Rebar : Providing & fixing in position of reinforcement bar of specified die by drilling hole in concrete with
specified drilling bit, cleaning of hole with air pump(manually),placing of reinforcement steel & injecting
chemical in hole by using approved make such as HILTI /or equivalent including cost of chemicals but
28 NSR9 excluding cost of reinforcement bars. -
The depth of hole to be minimum 10 times dia of rebar or as specified by vendor, as per direction
of Engineer-in-charge.
i i By using Re 500 V-3 chemical or equivalent. -
ii ii By using HY-200 chemical or equivalent. 0.00
SCHEDULE OF QUANTITIES OF CIVIL WORKS
DSR 2023 Amount (Rs.)
S. No. Description Of Item Unit Approx. Qty. Rate (Rs.)
Ref. No. DSR NSR
TOTAL OF NEW TECHNOLOGIES AND MATERIALS 1,05,38,568.00 1,60,71,125.49
SH-5: SH REINFORCED CEMENT CONCRETE WORK
29 5.9 Centring and shuttering including strutting, propping etc. and removal of form for:
a) 5.9.2 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. sqm 52.00 842.50 43,810.00
b) 5.9.20 Suspended floors, roofs,landings, balconies and access platform with water proof ply 12 mm thick sqm 780.00 1,028.40 8,02,152.00
c) 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts sqm 290.00 961.30 2,78,777.00
d) 5.9.7 Stairs, (excluding landings) except spiral-staircases. sqm 285.00 764.95 2,18,010.75
e) 5.9.21 Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick sqm 1,230.00 841.95 10,35,598.50
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping
30 5.11 etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every -
additional height of 1 metre or part thereof (Plan area to be measured)
30.1 5.11.1 Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) sqm 368.67 384.30 1,41,678.73
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced
cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland
Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS:
9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing
strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the
cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for
the following grades of concrete.
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable
separately. In case the cement content in design mix is more than 110% of the specified minimum
cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra
31.2 5.37.2 All works above plinth level upto floor V level -
31.2.1 5.33.2.2 Concrete of M30 grade with minimum cement content of 350 kg /cum cum 180.00 10,011.35 18,02,043.00
31.2.2 5.33.2.3 Concrete of M35 grade with minimum cement content of 370 kg /cum cum 220.00 10,162.35 22,35,717.00
31.2.3 5.33.2.5 Concrete of M50 grade with minimum cement content of 410 kg /cum cum 60.00 10,464.30 6,27,858.00
32 5.38 Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each four floors or part thereof. cum 180.00 355.65 64,017.00
TOTAL OF R.C.C WORKS CARRIED OVER TO SUMMARY OF CIVIL WORKS 72,49,661.98 -
SH-6: SH BRICK WORK
Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average
33 6.34 compressive strength in super structure above plinth level up to floor V level in :
33.1 6.34.2 Cement mortar 1:6 (1 cement : 6 Coarse sand) cum 576.00 8,752.55 50,41,468.80
Extra for brick work / AAC block masonry / Tile brick masonry in superstructure above floor V level, for
each four floors or part there of by mechanical means.
Half brick masonry with non modular fly ash bricks of class designation 10, conformingio IS :12894, in
35 6.45 super structure above plinth and upto floor V level. -
35.1 6.45.2 Cement mortar 1 : 4 (1 cement : 4 coarse sand) sqm 1,440.00 1,105.80 15,92,352.00
SCHEDULE OF QUANTITIES OF CIVIL WORKS
DSR 2023 Amount (Rs.)
S. No. Description Of Item Unit Approx. Qty. Rate (Rs.)
Ref. No. DSR NSR
Extra for half brick masonry in superstructure, above floor V level for every four floors or part thereof by
mechanical means.
TOTAL OF BRICK WORK CARRIED OVER TO SUMMARY OF CIVIL WORKS 66,33,820.80 -
SH-9: SH WOOD & PVC WORK
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought
framed and fixed in position :
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows,
including ISI marked stainless steel butt hinges of required size with necessary screws, excluding
38 9.5 panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. -
38.1 9.5.1 Second class teak wood -
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for
doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside
39 9.7 grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 -
39.1 9.7.1 Second class teak wood sqm 403.00 3,323.20 13,39,249.60
Extra for providing ISI marked stainless steel butt hinges instead of MS pressed butt hinges bright
finished of required size with necessary screws.( Shutter area to be measured )
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and
priming coat on unexposed surface etc.
41.1 9.40.1 2nd class teak wood -
Providing 40x5 mm flat iron hold fasts 40 cm. long including fixing to frame with 10 mm dia. Bolts,nuts
42 9.53 and wooden plugs and embedding in cement concrete block 30x10x15 cm. 1:3:6 mix ( 1 cement :3 each 2,400.00 228.85 5,49,240.00
coarse sand 6 graded stone aggregate 20 mm nominal size )
Providing and fixing bright finished brass towerbolts( barrel type ) with necessary screws etc. complete
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever
handles of approved quality with necessary screws etc. complete
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than
44 9.96 grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. -
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC
45 9.97 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. -
SCHEDULE OF QUANTITIES OF CIVIL WORKS
DSR 2023 Amount (Rs.)
S. No. Description Of Item Unit Approx. Qty. Rate (Rs.)
Ref. No. DSR NSR
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10
46 9.100 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : -
Providing and fixing aluminium hanging floor door stoppers,ISI marked,anodizes,(anodic coating not less
47 9.101 than grade AC10 as per IS :1868) transparent or dyed to required colour and shade,with necessary -
screws etc. complete
47.1 9.101.2 Twin rubber stoppers each 40.00 72.35 2,894.00
Providing and fixing aluminium casement stays,ISI marked,anodises ( anodic coating notless than grade
48 9.102 AC10 as per IS:1868) transparent or dyed to required colour and shade with necessary screws etc. each 80.00 71.50 5,720.00
Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of
16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete
mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire
49 9.136 seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size metre 21.60 1,709.25 36,919.80
and make, including applying a coat of approved brand fire resistant primer etc.complete as per direction
of Engineer-in-charge (Dash fastener to be paid for separately).
Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to
IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable
mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm
50 9.137 wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation sqm 21.60 7,533.20 1,62,717.12
material and fixing with necessary stainless steel ball bearing hinges of approved make, including
applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge
(panneling to be paid for separately).
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading
made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed
with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a
coat of approved fire resistant primer/powder coating of not less than 30 micron on G.I. beading, &
special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part
3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 60 minutes of
fire resistance both integrity & radiation control (EW60) and minimum 20 minutes of insulation (EI20).
The manufacturer have to give test report/certification of fire glass and the glass should have the stamp
showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any
other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per
ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be
more than 1100x2200 mm (w x h) or 2.42 sqm.
TOTAL OF WOOD WORK CARRIED OVER TO SUMMARY OF CIVIL WORKS 77,30,742.49 -
SH-10: SH STEEL WORK
SCHEDULE OF QUANTITIES OF CIVIL WORKS
DSR 2023 Amount (Rs.)
S. No. Description Of Item Unit Approx. Qty. Rate (Rs.)
Ref. No. DSR NSR
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S.
52 10.5 gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming
coat of approved steel primer.
52.1 10.5.1 Using M.S. angles 40x40x6 mm for diagonal braces. sqm 15.12 5,804.35 87,761.77
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked
together through their entire length and jointed together at the end by end locks mounted on
specially designed pipe shaft with brackets, side guides and arrangements for inside and outside
53 10.6 locking with push and pull operation complete including the cost of providing and fixing necessary -
27.5cm long wire springs grade No.2 and M.S. top cover of required thickness for rolling shutters.
53.1 10.6.1 80x1.25 mm M.S. laths with 1.25 mm thick top cover sqm 54.00 3,653.20 1,97,272.80
54 10.7 Providing and fixing ball bearing for rolling shutters. each 6.00 492.35 2,954.10
Extra for providing mechanical device chain and crank operation for operating rolling shutters.
55.1 10.8.1 Exceeding 10.00 sqm and upto 16.80 sqm in the area sqm - 1,281.35 -
Extra for providing grilled rolling shutters manufactured out of 8 mm dia. MS bar instead of laths as per
design approved by Enginer-in-charge ( area of grill to be measured )
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and
applying a priming coat of approved steel primer using structural steel etc.as required
57.1 10.25.2 In gratings, frames, guard bar, ladders, railings, brackets, gates & similar works kg 1,280.00 172.60 2,20,928.00
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting,
fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc.,
including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the
same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary
58 10.28 accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the kg 580.00 772.40 4,47,992.00
floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for
payment purpose only weight of stainless steel members shall be considered excluding fixing
accessories such as nuts, bolts, fasteners etc).
TOTAL OF STEEL WORK CARRIED OVER TO SUMMARY OF CIVIL WORKS 13,18,346.67 -
SH-11: SH FLOORING
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine
cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,
approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse
59 8.2 sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including
rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.
59.1 8.2.1 Raj Nagar Plain white marble/ Baroda green marble/ Zebra black marble
SCHEDULE OF QUANTITIES OF CIVIL WORKS
DSR 2023 Amount (Rs.)
S. No. Description Of Item Unit Approx. Qty. Rate (Rs.)
Ref. No. DSR NSR
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine
cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,
approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse
60 8.2 sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including
rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.
60.1 8.2.2 Granite stone slab of colour black, Cherry/Ruby red
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be
specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green,
61 8.31 black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm sqm 1,800.00 1,267.95 22,82,310.00
thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg
per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a
62 11.3 floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc.
62.1 11.3.1 40 mm thick with 20 mm nominal size stone aggregate sqm 210.00 614.20 1,28,982.00
63 11.24 Extra for pre finished nosing in treads of steps of marble stone metre 756.00 719.90 5,44,244.40
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry
64 11.26 mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of -
cement mortar 1:4 (1 cement : 4 coarse sand):
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the
manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except
65 11.38 White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 sqm 1,800.00 244.75 4,40,550.00
Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white
cement and matching pigments etc., complete.
Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the
manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand &
66 11.49 manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile -
adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints
(Payment for grouting of joints to be made separately).
66.1 11.49.3 Size of Tile as per design & drawing sqm 2,880.00 2,060.75 59,34,960.00
TOTAL OF FLOORING WORK CARRIED OVER TO SUMMARY OF CIVIL WORKS
SH-12: SH ROOFING
SCHEDULE OF QUANTITIES OF CIVIL WORKS
DSR 2023 Amount (Rs.)
S. No. Description Of Item Unit Approx. Qty. Rate (Rs.)
Ref. No. DSR NSR
Providing and fixing in position wall panelling at all heights with integral densified calcium silicate
panels/tiles of size 595 x 595mm, having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS
8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire
performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity <0.043 W/m K
as per ASTM 518:1991, comprising of a frame made from especially fabricated galvanised mild steel
sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both sides) i.e.vertical
studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor and ceiling channel section
of size 50 x 32m fixed to the floor and soffit at 600mm centers using 12mm dia,50mm long wedge type
expanded zinc alloy dash fastner with 10mm bolt. This same channel is then to be fixed in horiziontal
direction at 600mm center to center so as to form a grid of 600mm x 600mm. Glasswool of 50mm
thickness is then to be inserted in the slots and finally calcium silicate non combustible panels/tiles are to
be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2mm on to this
grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly
jointed and finished using recommended jointing calcium silicate based compound and fiber joint tape roll
50mm wide (90 metre )roll and two coats of primer suitable for panelling as per manufacturer's
specification as
per direction of Engineer-in-Charge all complete.
67.1 26.24.1 With 15 mm thick fully perforated square/butt edge light weight calcium silicate panels/ tiles sqm 750.00 3,117.60 23,38,200.00
TOTAL OF ROOFING WORK CARRIED OVER TO SUMMARY OF CIVIL WORKS
SH-13: SH FINISHING
68 13.1 12 mm cement plaster of mix:
69 13.2 15 mm cement plaster on the rough side of single or half brick wall of mix : -
70 13.16 6 mm cement plaster of mix -
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to pepare the
surface even and smooth complete .
72 13.45 Finishing walls with textured exterior paint of required shade : -
New work (Two or more coats applied @ 3.28 ltr/10 sqm. over and including priming coat of exterior
primer applied @ 2.20 kg/10 sqm).
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less
73 13.41 than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever -
required, to achieve even shade and colour
New wor (Two or more coats) over and including water thinnable priming coat with cement primer having
VOC content less than50 gram/ litre
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic
74 13.83 Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying -
additional coats wherever required to achieve even shade and colour.
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile
Organic Compound ) content.
SCHEDULE OF QUANTITIES OF CIVIL WORKS
DSR 2023 Amount (Rs.)
S. No. Description Of Item Unit Approx. Qty. Rate (Rs.)
Ref. No. DSR NSR
With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than
50 grams/ litre
75.2 13.85.3 With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre sqm 188.94 73.95 13,972.01
76 13.63 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : -
76.1 13.63.1 Two or more coats on new work sqm 745.55 146.80 1,09,447.42
TOTAL OF FINISHING WORK CARRIED OVER TO SUMMARY OF CIVIL WORKS
SH-16: SH ROAD WORK
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The
ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process
and finally finished by floating, brooming with wire brush etc. complete as per specifications and
77 16.75 directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement sqm 720.00 9,823.80 70,73,136.00
content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/
recoverable separately).
TOTAL OF ROAD WORKS CARRIED OVER TO SUMMARY OF CIVIL WORKS 70,73,136.00 -
SH-22: SH WATER PROOFING
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of
WC's,Kitchen and the like consisting of :
Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound confirming to IS
(i) 2645 in recommended proportions including rounding of junctions of vertical and horizontal surface.
IInd course of 20 mm cement plaster 1:3 ( 1 cement :3 coarse sand ) mixed with water proofing
(ii) compound in recommended proportion including rounding off junction of vertical and horizontal surface.
(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg.per sqm of area
IVth course of 400 micron thick PVC sheet( Overlaps at joints of PVC sheet should be 100 mm wide and
pasted to each other with bitumen @ 1.7 kg/sqm
SCHEDULE OF QUANTITIES OF CIVIL WORKS
DSR 2023 Amount (Rs.)
S. No. Description Of Item Unit Approx. Qty. Rate (Rs.)
Ref. No. DSR NSR
Providing and laying integral cement based water proofing treatment including preparation of surface as
required for treatment of roofs,balconies,terrace etc. consisting of following operations.Applying a slurry
coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to
IS. 2645 and approved by E-in- Charge over the RCC slab including adjoining walls up to 300 mm height
including cleaning the surface before treatment..Laying brick bats with mortar using broken bricks/brick
bats 25mm to 100mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with
water proofing compound conforming to IS : 2645 and approved by E-in- Charge over 20mm thick layer
of cement mortar of mix 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound
conforming to IS : 2645 and as approved by E-in Charge to required slope and treating similarly the
79 22.7 adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.After two days of
proper curing applying a second coat of cement slurry admixed with water proofing compound
conforming to IS : 2645.and approved by E-in-Charge.Finishing the surface with 20mm thick jointless
cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound conforming
to IS : 2645 and approved by E-in -Charge including laying glass fibre cloth of approved quality in top
layer of plaster and finally finishing the surface with trowel with neat cement slurry and making of 300 x
300 mm square 3 mm deep.The whole terrace so finished shall be flooded with water for a minimum
period of two weeks for curing and for final test. All above operations to be done in order and as directed
and specified by the Engineer-in-Charge.
79.1 22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 cms. sqm 1,880.00 1,684.60 31,67,048.00
TOTAL OF WATER PROOFING WORK CARRIED OVER TO SUMMARY OF CIVIL
SH-25: EXTERIOR FINISH (FAÇADE)
I) GRC (Glass Reinforced Concrete)
Providing & Fixing Glass Reinforced Concrete (GRC) panels including all items required & as the
direction of Engineer -in-Charge.
II) TEXTURED PAINT
81 13.45 Finishing walls with textured exterior paint of required shade :
New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior
primer applied @ 2.20kg/10 sqm
TOTAL OF EXTERIOR FINISH (FAÇADE) 42,29,298.00 -
BARRICADING WORK
Providing and erecting barricading for height above + 2.0 m and up to +10.0 m high at site and 2.0 m
platform alround the building to retain any material during dismantling/construction as per drawing
82 /direction of Engineer-In Charge including required signages etc complete consisting of following items :
SCHEDULE OF QUANTITIES OF CIVIL WORKS
DSR 2023 Amount (Rs.)
S. No. Description Of Item Unit Approx. Qty. Rate (Rs.)
Ref. No. DSR NSR
Providing and fixing pre-coated galvanised iron profile sheets (size, shape and pitch of corrugation as
approved by Engineer-incharge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams
per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and
polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to
avoid scratches during transportation and should be supplied in single length up to 12 metre or as
desired by Engineer- in-charge. The sheet shall be fixed using self drilling /self tapping screws of size
(5.5x 55 mm) with EPDM seal, complete up to any pitch in horizontal/ vertical or curved surfaces,
excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever
required. (Note :One time payment shall be made for providing barricading from start of work till
completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor
on ion of the work). Vertical nd U value of 3.0 to 3.3 W/m2 K etc.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including
cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
82.2 10.2 (Note :- One time payment shall be made for providing barricading from start of work till completion of kg 6,200.00 133.70 8,28,940.00
work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion
of the work after deducting salvage value of material through separate item)
Credit for salvage value of sheeting and structural steel of Item no. 68.1 and 68.2 (50% of total
TOTAL OF BARRICADING WORK 14,78,126.00 -
FURNITURE & FURNISHING WORK
Providing and fixing of premium quality cup boards as per design and to the satisfaction of the Engineer-
84 NSR11 in-Charge/ Architect. The rates shall include all hardware, fittings, adhesives, beadings, lippings etc. sqft 1,750.00 1,800.00 31,50,000.00
Details of cup boards are as below:
Overall Size including top cornice : Width - 946.0 mm Depth - 598.0 mm Height - 1941.0 mm. Material
:Body panels are made of 18 mm thick water proof plywood. All the exposed edges are edge banded with
0.8 mm thick PVC edge banding. Door are made of 18 mm thick water proof plywood with all the
exposed edges are edge banded with 0.8 mm thick PVC edge banding. Side panel are made of 18 mm
thick water proof plywood with all the exposed edges are edge banded with 0.8 mm thick PVC edge
banding and with imported H.D.F. foil wrapped decorative trim fixed on to it. Drawer components are
made of 18 mm thick water proof plywood. All the exposed edges are edge banded with 0.8 mm thick
PVC edge banding. Body back and drawer bottom are made of 12 mm mm thick water proof plywood.
Top cornice is made of imported H.D.F. foil wrapped decorative Trim. Hardware : The high quality
hardware used like Roller slides, Hinges , minifix,wooden dowels is of make Hettich. Lock used for main
door is 3 way lock and lock used for drawer is cam lock Construction : Knock Down construction. Packets
: 2 packet. Finish :18 mm thick water proof plywood is in Walnut shade.
Providing and fixing of premium quality Modular Kitchen as per design and to the satisfaction of the
85 NSR12 Engineer-in-Charge/ Architect. The rates shall include all hardware, fittings, adhesives, beadings, lippings
etc. Details of Modular Kitchen are as below:
SCHEDULE OF QUANTITIES OF CIVIL WORKS
DSR 2023 Amount (Rs.)
S. No. Description Of Item Unit Approx. Qty. Rate (Rs.)
Ref. No. DSR NSR
Providing & fixing factory made modular kitchen cabinets carcase with openable shutters and sufficient
number of drawers made of 0.6mm body panels & 1.2mm thick horizontal Frames of Galvanised sheet
with zero spangels(as per ASTM A653), components shall be powder coated with high quality powders
like Dupont, Kanasai Nerolac with dry film thickness of 40 to 60 microns with pencil hardness of 2H Min.
The powder coat would be fringyspus in nature and impart the same in appearence . All shelves should
be supported on approved quality SS pins and shall be adjustable for different heights as per
requirements.Shutters to be at least 18mm thick in BWP marine Ply IS 710 grade with laminate on both
sides with 18mm wide 2mm thick edge banding. Each shutter shall be fixed to the carcass using two
numbers of best quality CED coated hinges ( Blum, Hettich approved make) i/c soft/Auto closing
hinges as per requirement(Hettich make or equivalent) fixed with SS screws , nails etc complete and
these shutters are provided with an approved quality of Godrej Arc 128 mm pitch. Finished components
shall be tested for the critical quality parameters ,Adhesion and impact test which enhances the life of
kitchen.Shelves to be of galvanised steel sheet with thickness of 12 mm with even wire basket in grade
304 SS.Carcass and shutters shall have passed the test like Static Load test,Shelf deflection
test.Modular kitchen accessories, payment for which will be made separately) to be fixed in the
drawer/Cabinet with suitable provision with panels of bottom and rear shelves with thickness of 0.6mm
as per technical requirement. The carcase of floor units units will be supported by 100mm height vertical
ajustable legs (Hettich or equivalent approved) which will be covered with PVC skirting (Rehau or
equivalent make ) in brushed aluminium finish attached by hardware of skirting.The unit shall be fixed to
the floor/ wall/slab using metal screws of appropriate size and rawl plugs . The work shall be executed as
per drawing/Sample prepared in sample flat at site and direction of Engineer-in-charge. Only face area of
openable shutter and drawer shall be measured for payment. Cabinet with depth of 560mm(Approx).
B Sub Head: Modular Kitchen : Wall units
Providing & fixing factory made modular kitchen cabinets with openable shutters and having 0.6mm body
panels & 1.2mm thick horizontal Frames of Galvanised sheet with zero spangels(as per ASTM A653),
components shall be powder coated with high quality powders like Dupont, Kanasai Nerolac with dry film
thickness of 40 to 60 microns with pencil hardness of 2H Min. The powder coat would be fringyspus in
nature and impart the same in appearence.
All shelves shall be supported on approved quality SS pins and shall be adjustable for different heights as
per requirements.Shutters to be at least 18mm thick in Galvanised steel .Shutters to be at least 18mm
thick in BWP marine Ply IS710 grade with laminates on both sides with 18mm wide 2 mm thick edge
banding as well as Glass shutters. The glass used in top unit shutters are used of Saint Gobain or
equivalent make. The glass used is itching in nature with 6mm thickness. Each shutter shall be fixed to
2 the framework/carcass using two numbers of best quality CED coated hinges ( Blum, Hettich approved
make) i/c soft/Auto closing hinges as per requirement(Hettich make or equivalent) fixed with SS screws ,
nails etc complete and these shutters are provided with an approved quality 128 mm pitch Handle .
Finished components shall be tested for the critical quality parameters ,Adhesion and impact test which
enhances the life of kitchen.Shelves to be of galvanised steel sheet with thickness of 12 mm . Steel
carcase and shutters shall have passed the test like Static Load test,Shelf deflection test..The unit shall
be hanged on to the the wall using metal screws of appropriate size and rawl plugs . The work shall be
executed as per drawing/Sample prepared in sample flat at site and direction of Engineer-in-charge. Only
face area of openable shutter and drawer shall be measured for payment. Cabinet with depth of 300
C Sub Head: Modular Kitchen : Tall Unit
SCHEDULE OF QUANTITIES OF CIVIL WORKS
DSR 2023 Amount (Rs.)
S. No. Description Of Item Unit Approx. Qty. Rate (Rs.)
Ref. No. DSR NSR
Providing & placing factory made modular kitchen having Tall Unit with openable shutters and 1.2mm
thick horizontal Frames of Galvanised sheet with zero spangels(as per ASTM A653), components shall
be powder coated with high quality powders like Dupont, Kanasai Nerolac with dry film thickness of 40 to
60 microns with pencil hardness of 2H Min. The height of unit is 2000 mm. All shelves shall be supported
on approved quality SS pins and shall be adjustable for different heights as per requirements.Shutters to
be at least 18mm thick in Galvanisheet steel . Each shutter shall be fixed to the framework/carcass using
two numbers of best quality CED coated hinges ( Blum, Hettich approved make) i/c soft/Auto closing
hinges as per requirement(Hettich make or equivalent) fixed with SS screws , nails etc complete and
these shutters are provided with an approved quality of Godrej Arc 128 mm pitch. Finished components
shall be tested for the critical quality parameters ,Adhesion and impact test which enhances the life of
kitchen.Shelves to be of galvanised steel sheet with thickness of 12 mm with even wire basket in grade
1 304 SS. Steel carcass and shutters shall have passed the test like Static Load test,Shelf deflection
test.Modular kitchen accessories, payment for which will be made separately) to be fixed in the
drawer/Cabinet with sutable provision with panels of bottom and rear shelves with thickness of 0.6mm as
per technical requirement. Tall units will be supported by 100mm height vertical ajustable legs (Hettich or
equivalent approved) which will be covered with PVC skirting (Rehau or equivalent make ) in brushed
aluminium finish attached by hardware of skirting. The unit shall be fixed to the floor/ wall/slab using
metal screws of appropriate size and rawl plugs . The work shall be executed as per drawing/Sample
prepared in sample flat at site and direction of Engineer-in-charge. Only face area of openable shutter
and drawer shall be measured for payment. Cabinet with depth of 560mm(Approx).
D Sub Head- Kitchen Accessories,
Providing and fixing Utensil Kit of size 900mm in 304 SS grade i/c a set of 2 Plain SS wire baskets 150
1 mm with required SS screw for fixing above component, complete as per drawing in the exisitng space,
sample prepared in sample flat at site and direction of Engineer-in-charge.
Providing and fixing Grocery Kit of size 450 mm in 304 SS grade i/c a set of 2 plain SS wire baskets 150
2 mm with required SS screw for fixing above component complete as per drawing in the exisitng space,
sample prepared in sample flat at site and direction of Engineer-in-charge.
Providing and fixing Cooking Kit in 304 SS Grade i/c 2 Plain Basket 100 mm and 150 mm + Drawer with
Cutlery Tray with 600m width , and fittings required SS screw for fixing above component, complete as
3 per drawing in the exisitng space, sample prepared in sample flat at site and direction of Engineer-in-
4 Providing and fixing GTPT Kit in 304 SS Gradefittings required SS screw for fixing above component
complete as per drawing in the exisitng space, sample prepared in sample flat at site and direction of
Engineer-in-charge.
WPC board to be placed over floor units sqft 1,200.00 1,250.00 15,00,000.00
Providing and fixing of premium quality Wooden Bed as per design and to the satisfaction of the Engineer-
86 NSR13 in-Charge/ Architect. The rates shall include all hardware, fittings, adhesives, beadings, lippings etc. The
details of bed are as below:
Material of Bed Frame-18 mm thick water proof plywood
Material of Bottom Pannel of Storage Box- 18 mm thick water proof plywood
Material of Front, Back and side Pannels- 18 mm thick water proof plywood
SCHEDULE OF QUANTITIES OF CIVIL WORKS
DSR 2023 Amount (Rs.)
S. No. Description Of Item Unit Approx. Qty. Rate (Rs.)
Ref. No. DSR NSR
Material of Headrest- 18 mm thick water proof plywood
Material of Legrest- 18 mm thick water proof plywood
Material of Matresses Pannel- Other wood
Finish- Laminated
The overall size of the bed shall be 1524mm (W) x 2060mm (L) x 610mm (H). The bed shall be provided
with one coir matteress of 4 inch thickness. The work shall be carried out as per the instructions received Set 14.00 32,000.00 4,48,000.00
from engineer in charge.
Providing and fixing of premium quality Centre Table as per design and to the satisfaction of the Engineer-
87 NSR14 in-Charge/ Architect. The rates shall include all hardware, fittings, adhesives, beadings, lippings etc. The
details of centre table are as below:
Providing in position of Center table of following specifications. The overall size shall be : Width - 1000
mm, Depth-600, Height - 428 mm. Material : Glass shall be of 08 mm thk tempered glass. Legs and
frame shall be Solid rubber wood. Bottom shelf shall be a sheet of MS. Rubber wood parts shall be Set 14.00 12,000.00 1,68,000.00
PU coated and shall have clear glass. Metal frames are powder coated in shade Black to the thickness
of 40-80 microns.
Providing and fixing of premium quality Corner Table as per design and to the satisfaction of the Engineer-
88 NSR15 in-Charge/ Architect. The rates shall include all hardware, fittings, adhesives, beadings, lippings etc. The
details of corner table are as below:
Providing in position corner table of following specifications. The overall size shall be : Width - 500 mm,
Depth-500, Height - 428 mm. Material : Glass shall be of 08 mm thk tempered glass. Legs and frame
shall be Solid rubber wood. Bottom shelf shall be a sheet of MS. Rubber wood parts shall be PU Set 14.00 7,500.00 1,05,000.00
coated and shall have clear glass. Metal frames are powder coated in shade Black to the
thickness of 40-80 microns.
Providing and Placing in place of 2 seater sofa. The overall dimensions shall be 1560 x 935 x 890mm.
Understructure is made up of combination of plywood & pinewood members. Plywood is 12±1mm
thk. [moisture resistance & termite proof as per IS:303] & pinewood are of cross sections 22x64mm,
34x64mm & 16x35mm without having major knots & defects on the surface. Zigzag spring of dia. 3.8mm
is mounted on the seat structure using plastic spring mounting clip for support & additional cushioning
purpose. Non woven fabric is stapled on the seat structure frame above the spring asly. to avoid direct
contact between the metal springs and the seat foam. Powder coated MS support pipe is fitted with the
89 NSR16 wooden seat frame to give additional strength to the structure. Seat is made of PU foam with density 28 Set 14.00 1,500.00 21,000.00
kg/m3 with a top layer of supersoft PU foam with density 32kg/m3. Recron sheet of 200GSM is wrapped
& glued above this seat top foam. Seat front bottom is glued with the PU foam with density 28 kg/m3. :
Seat upholstery is made in polyester fabric, having pockets to insert the seat foam. The fabric has a
special coating which gives it a leather like feel. Plastic legs with the M8 stud are fitted at the bottom
surface of both the armrests and on front of the seat.
Providing and fixing of premium quality Wooden Dining Table with 4 nos. of Wooden Chairs as per
design, drawing & specifications and to the satisfaction of the Engineer-in-Charge/ Architect.
SCHEDULE OF QUANTITIES OF CIVIL WORKS
DSR 2023 Amount (Rs.)
S. No. Description Of Item Unit Approx. Qty. Rate (Rs.)
Ref. No. DSR NSR
Providing and fixing of premium quality Wooden Study Table as per design, drawing & specifications and
to the satisfaction of the Engineer-in-Charge/ Architect.
Providing and fixing of premium quality Wooden TV Mounting Stand as per design, drawing &
specifications and to the satisfaction of the Engineer-in-Charge/ Architect.
Providing and fixing of premium quality Wooden Luggage Rack as per design, drawing & specifications
and to the satisfaction of the Engineer-in-Charge/ Architect.
Providing and fixing of premium quality Wooden Dressing with premium quality mirror and wooden stool
93 NSR21 as per design, drawing & specifications and to the satisfaction of the Engineer-in-Charge/ Architect. Set 14.00 12,000.00 1,68,000.00
Providing and fixing of premium quality Wooden Chair as per design and to the satisfaction of the
Engineer-in-Charge/ Architect. The rates shall include all hardware, fittings, adhesives, beadings, lippings
etc. The details of chair are as below:
TOTAL OF FURNITURE & FURNISHING WORK - 67,08,000.00
NBCC (India) Limited
Page 1 of 17 Digitally signed by AMIT JAIN
WRPC, ANDHERI WEST , MUMBAI
SCHEDULE OF QUANTITES
Providing, Fixing, testing and commissioning of 15 mm dia C.P. brass
Short / Long Body bib cock with C.P. wall flange of approved quality
Providing, Fixing, testing and commissioning of C.P. brass angle valve
with C.P. wall flange, Nut and Washer etc. complete as required.
Providing, Fixing, testing and commissioning of Wall Mixer for for cold
and hot water supply
Providing, Fixing, testing and commissioning of C.P. brass wall /
4 counter mounted sink mixer with C.P. wall flange, overhead swinging Nos. 20 2300 46000
spout complete as required and making good.
Providing, Fixing, testing and commissioning of C.P. brass wall /
5 counter mounted wash basin mixer with C.P. wall flange, overhead Nos. 120 2150 258000
swinging spout complete as required and making good.
Page 2 of 17 Digitally signed by AMIT JAIN
providing, and fixingfirst quality white vitreous china wash basin (size
as per architectural drawing) for under / over counter mounting,
specially fabricated CI / MS brackets, including providing & providing
6 and fixingpainted with two or three coats of enamel paint of Nos. 120 3500 420000
approved shade over a coat of primer, complete including filling gap
between counter and wash basin with approved type poly sulphide
sealant, cutting and making good the walls wherever required.
Providing ,Fixing, testing and commissioning of C.P. health faucet for
7 ablution and flexible hose 1 m long connection with C.P. holder for Nos. 120 760 91200
hand spray complete in all respects.
Providing, Fixing, testing and commissioning of complete shower
assembly comprising the following, including making cutting and
making good the walls wherever required
a) Shower wall maixer with diverter with provision of spout, C.P
overhead shower complete with long bend pipe of 115mm and
telephonic hand shower
b)Overhead rain shower with revolving joint and shower arm with
c) Telephonic Hand Shower with flexible 1.5 m flexible hose, hook and
all accessories.
Page 3 of 17 Digitally signed by AMIT JAIN
Providing, Fixing, testing and commissioning of complete shower
panel assembly 1500x230 mm comprising the following, including
making cutting and making good the walls wherever required
b)Overhead rain shower with revolving joint
c) Telephonic Hand Shower with flexible 1.5 m flexible hose, hook and
all accessories.
Providing,Fixing, testing and commissioning of white vitreous China
wall / Floor mounting type European water closet / seat cover with
Supply of C.P. bolts, nuts, C.I. chair, Connection Pipes etc or other
10 hanging arrangements, including providing & providing and fixingpaint Nos. 6 6400 38400
with two coats of enamel paint over a coat of primer, hinges & rubber
buffers, C.P. brass screw, washer with all accessories. Including
cutting & making good the walls, floors, slab wherever required.
Providing and fixing S.S Kitchen Sink double/single bowl with drain
board with C.I. bracket,best jali as per approved.
12 Providing and fixingpvc cPVC ball valves of approved quality. 0
Page 4 of 17 Digitally signed by AMIT JAIN
Providing, fixing, jointing and testing in position C-PVC (Chlorinated
Poly Vinyl Chloride) of approved manufacturer for water supply pipes
and fittings as per CTS SDR - 11 pipes at a working pressure of of
22.50 kg /sq.cm at 23 deg C and 5.5 kg/sq.cm at 82 deg.C using
moulded CPVC fittings e.g Tees, Elbows, Couplers, Unions, Reducers,
Adapters, Bushings etc. including transition fittings connection
between CPVC & metal pipe / GI with Brass Adaptors (Both Male &
Female threaded) conforming to ASTM D-2846 with only CPVC
solvent cement conforming to ASTM F-493 with fabricated &
subsequently rubber line bracket, hot dip galvanized clamps (2 coats
of enamel paint) supports as required / directed at site including
cutting and providing and fixingthe same with anchor fastners,
including painting the exposed pipes with one coat of desired shade
of enamel paint. All termination points for installation shall have brass
termination fittings. The rates to include for chasing in brick masonry
with wire mesh / PCC for internal water supply pipes and making
good the same in 1:4 cement mortar, cleaning the debris and carting
outside the site premises.
Page 5 of 17 Digitally signed by AMIT JAIN
Providing ,fixing, testing and commissioning of G.I heavy class pipe
and fittings such as bends, junctions for indirect waste, jointing,
providing and fixingat wall / ceiling level supported by bracket &
14 hangers etc. duly epoxy coated. Cutting, chases / holes in floors /
walls / slab complete in all respect. (The rate includes the cost of two
coat of primer and two coat of enamel paint and pypcote wrapping
for the underground pipe )
Page 6 of 17 Digitally signed by AMIT JAIN
Providing, jointing and providing and fixing UPVC Soil, Waste and
Vent System ,The work shall be done as per technical specifications
and in general shall include:Material: UPVC pipes and fittings
(moulded as well as fabricated) conforming to IS : 13592 type
15 B,Fittings shall include all standard moulded as well as fabricated
fittings like bends, tees, Y-tees, crosses, boss connections, access
pieces, saddle pieces, cleanouts, adaptors,Jointing: Pushfit rubber ring
jointing technique in general. Solvent cement joints may be provided
for fittings and specials which are not manufactured with pushfit rubb
15.1 50 mm dia. UPVC pipes of 6Kg/cm2 i/c all fittings. Rmt 300 535 160500
15.2 75 mm dia. UPVC pipes of 6Kg/cm2 i/c all fittings. Rmt 120 688 82560
15.3 110 mm dia UPVC pipes of 6Kg/cm2 i/c all fittings. Rmt 120 970 116400
110 mm dia S.W.R. Soil waste/ Soil stack pipes of 6Kg/cm2 i/c all
8 Providing & providing and fixingP.R.V. (Pressure reducing valve)
Page 7 of 17 Digitally signed by AMIT JAIN
Providing and providing and fixingof UPVC Floor Traps formed out of
bore 'P' trap with 50 mm water seal, setting in 1:2:4 mix cement
9 concrete block or clamping to the wall or suspending with the ceiling No. 21 997 20937
including cutting and making good the walls and floors wherever
10 Proving & providing and providing and fixing Slotted angle. Rmt 86 250 21600
12.1 Providing & providing and fixing 50 mm dia G.I. Union Nos. 4 700 2800
12.2 Providing & providing and fixing 80mm dia G.I. Union Nos. 4 850 3400
Providing and providing and providing and fixing C.P. brass grating of
13 approved quality and make conforming to IS:specification. 100 mm Nos. 240 95 22800
Supplying and fixing approved make SS towel
rod of 20 mm dia, 600 mm long with concealed
14 brackets fixing to wall dado using suitable size Nos. 80 460 36800
non-corrosive screws, teak wood plugs etc.
Providing and fixing of CP brass waste coupling of approved quality
and make for sink and wash basin
Page 8 of 17 Digitally signed by AMIT JAIN
Providing and fixing CP brass bottle trap of approved quality and
make for wash basin.
Providing & providing and providing and fixingbutterfly valve (Body
: Grey Cast Iron, Shaft : SS, Disc : SG Iron (Rilson coated), Liner : HT -
EPDM) (upto 150mm dia with hand lever operation & above
18 with gear box operation) with a working pressure not less than 16
Kg/Sq.cm. Including chain/pad lock arrangement, rubber gasket,
flanges, nuts, bolts, washers & painting complete as
Providing Fixing, testing and commissioning of PVC connection 450
19.0 mm long including nuts and washers and making connection to Nos. 140 145 20300
fixtures and fittings complete as required.
Page 9 of 17 Digitally signed by AMIT JAIN
WRPC, ANDHERI WEST , MUMBAI
SCHEDULE OF QUANTITES
Providing, Fixing, testing and commissioning of 15 mm dia C.P. brass
1 Short / Long Body bib cock with C.P. wall flange of approved quality Nos. 20 460 9200
and making good as required.
Providing, Fixing, testing and commissioning of C.P. brass angle valve
with C.P. wall flange, Nut and Washer etc. complete as required.
Providing, Fixing, testing and commissioning of Wall Mixer for for cold
and hot water supply
Providing, Fixing, testing and commissioning of C.P. brass wall /
4 counter mounted sink mixer with C.P. wall flange, overhead swinging Nos. 20 2300 46000
spout complete as required and making good.
Providing, Fixing, testing and commissioning of C.P. brass wall /
5 counter mounted wash basin mixer with C.P. wall flange, overhead Nos. 20 2150 43000
swinging spout complete as required and making good.
Page 10 of 17 Digitally signed by AMIT JAIN
providing, and fixingfirst quality white vitreous china wash basin (size
as per architectural drawing) for under / over counter mounting,
specially fabricated CI / MS brackets, including providing & providing
6 and fixingpainted with two or three coats of enamel paint of Nos. 20 3500 70000
approved shade over a coat of primer, complete including filling gap
between counter and wash basin with approved type poly sulphide
sealant, cutting and making good the walls wherever required.
Providing ,Fixing, testing and commissioning of C.P. health faucet for
7 ablution and flexible hose 1 m long connection with C.P. holder for Nos. 20 760 15200
hand spray complete in all respects.
Providing, Fixing, testing and commissioning of complete shower
assembly comprising the following, including making cutting and
making good the walls wherever required
a) Shower wall maixer with diverter with provision of spout, C.P
overhead shower complete with long bend pipe of 115mm and
telephonic hand shower
b)Overhead rain shower with revolving joint and shower arm with
c) Telephonic Hand Shower with flexible 1.5 m flexible hose, hook and
all accessories.
Page 11 of 17 Digitally signed by AMIT JAIN
Providing, Fixing, testing and commissioning of complete shower
panel assembly 1500x230 mm comprising the following, including
making cutting and making good the walls wherever required
b)Overhead rain shower with revolving joint
c) Telephonic Hand Shower with flexible 1.5 m flexible hose, hook and
all accessories.
Providing,Fixing, testing and commissioning of white vitreous China
wall / Floor mounting type European water closet / seat cover with
Supply of C.P. bolts, nuts, C.I. chair, Connection Pipes etc or other
10 hanging arrangements, including providing & providing and fixingpaint Nos. 6 6400 38400
with two coats of enamel paint over a coat of primer, hinges & rubber
buffers, C.P. brass screw, washer with all accessories. Including
cutting & making good the walls, floors, slab wherever required.
Providing and fixing S.S Kitchen Sink double/single bowl with drain
board with C.I. bracket,best jali as per approved.
12 Providing and fixingpvc cPVC ball valves of approved quality. 0
Page 12 of 17 Digitally signed by AMIT JAIN
Providing, fixing, jointing and testing in position C-PVC (Chlorinated
Poly Vinyl Chloride) of approved manufacturer for water supply pipes
and fittings as per CTS SDR - 11 pipes at a working pressure of of
22.50 kg /sq.cm at 23 deg C and 5.5 kg/sq.cm at 82 deg.C using
moulded CPVC fittings e.g Tees, Elbows, Couplers, Unions, Reducers,
Adapters, Bushings etc. including transition fittings connection
between CPVC & metal pipe / GI with Brass Adaptors (Both Male &
Female threaded) conforming to ASTM D-2846 with only CPVC
solvent cement conforming to ASTM F-493 with fabricated &
subsequently rubber line bracket, hot dip galvanized clamps (2 coats
of enamel paint) supports as required / directed at site including
cutting and providing and fixingthe same with anchor fastners,
including painting the exposed pipes with one coat of desired shade
of enamel paint. All termination points for installation shall have brass
termination fittings. The rates to include for chasing in brick masonry
with wire mesh / PCC for internal water supply pipes and making
good the same in 1:4 cement mortar, cleaning the debris and carting
outside the site premises.
Page 13 of 17 Digitally signed by AMIT JAIN
Providing ,fixing, testing and commissioning of G.I heavy class pipe
and fittings such as bends, junctions for indirect waste, jointing,
providing and fixingat wall / ceiling level supported by bracket &
14 hangers etc. duly epoxy coated. Cutting, chases / holes in floors /
walls / slab complete in all respect. (The rate includes the cost of two
coat of primer and two coat of enamel paint and pypcote wrapping
for the underground pipe )
Page 14 of 17 Digitally signed by AMIT JAIN
Providing, jointing and providing and fixing UPVC Soil, Waste and
Vent System ,The work shall be done as per technical specifications
and in general shall include:Material: UPVC pipes and fittings
(moulded as well as fabricated) conforming to IS : 13592 type
15 B,Fittings shall include all standard moulded as well as fabricated
fittings like bends, tees, Y-tees, crosses, boss connections, access
pieces, saddle pieces, cleanouts, adaptors,Jointing: Pushfit rubber ring
jointing technique in general. Solvent cement joints may be provided
for fittings and specials which are not manufactured with pushfit rubb
15.1 50 mm dia. UPVC pipes of 6Kg/cm2 i/c all fittings. Rmt 100 535 53500
15.2 75 mm dia. UPVC pipes of 6Kg/cm2 i/c all fittings. Rmt 160 688 110080
15.3 110 mm dia UPVC pipes of 6Kg/cm2 i/c all fittings. Rmt 160 970 155200
110 mm dia S.W.R. Soil waste/ Soil stack pipes of 6Kg/cm2 i/c all
8 Providing & providing and fixingP.R.V. (Pressure reducing valve)
Page 15 of 17 Digitally signed by AMIT JAIN
Providing and providing and fixingof UPVC Floor Traps formed out of
bore 'P' trap with 50 mm water seal, setting in 1:2:4 mix cement
9 concrete block or clamping to the wall or suspending with the ceiling No. 21 997 20937
including cutting and making good the walls and floors wherever
10 Proving & providing and providing and fixing Slotted angle. Rmt 86 250 21600
12.1 Providing & providing and fixing 50 mm dia G.I. Union Nos. 4 700 2800
12.2 Providing & providing and fixing 80mm dia G.I. Union Nos. 4 850 3400
Providing and providing and providing and fixing C.P. brass grating of
13 approved quality and make conforming to IS:specification. 100 mm Nos. 80 95 7600
Supplying and fixing approved make SS towel
rod of 20 mm dia, 600 mm long with concealed
14 brackets fixing to wall dado using suitable size Nos. 40 460 18400
non-corrosive screws, teak wood plugs etc.
Providing and fixing of CP brass waste coupling of approved quality
and make for sink and wash basin
Page 16 of 17 Digitally signed by AMIT JAIN
Providing and fixing CP brass bottle trap of approved quality and
make for wash basin.
17 Providing and fixing MS angle for support the wash basin and Sink. Kg 250 130 32500
Providing & providing and providing and fixingbutterfly valve (Body
: Grey Cast Iron, Shaft : SS, Disc : SG Iron (Rilson coated), Liner : HT -
EPDM) (upto 150mm dia with hand lever operation & above
18 with gear box operation) with a working pressure not less than 16
Kg/Sq.cm. Including chain/pad lock arrangement, rubber gasket,
flanges, nuts, bolts, washers & painting complete as
Providing Fixing, testing and commissioning of PVC connection 450
19.0 mm long including nuts and washers and making connection to Nos. 40 145 5800
fixtures and fittings complete as required.
Page 17 of 17 Digitally signed by AMIT JAIN
GRAND TOTAL 1,87,96,966
totally any item of work. Any claim by the Contractor on these accounts will not be
All the items of work given in this schedule of quantities shall be executed strictly in
accordance with the latest Indian Standard Specifications and the requirements of the
Electricity Supply Authority read in conjunction with the relevant drawings and
Specifications.
The Contractor shall visit the site and shall satisfy himself as to the conditions under
which the work is to be performed. He shall also check and ascertain the location of
any existing structure or equipment or any other situation which may affect the work.
No extra claim as a consequence of ignorance or on ground of insufficient
description will be allowed at a later date.
All equipment and material shall be BIS complete
vendor drawings shall be approved by the consultant before fabrication work starts.
All Testing and Commissioning shall be as per relevant IS for equipment and
IS:732:1989 for the installation. All these testing records are to be maintained.
S.No Description UOM QTY RATES AMOUNT
The rate for each item of work included in the Schedule of Quantities shall, unless
expressly stated otherwise, include cost of :
a. All materials, fixing materials, accessories, appliances tools, plants, equipment,
transport, labour and incidentals required in preparation for and in the full and entire
execution, testing, balancing, commissioning and completion of work called for in the
item and as per Specifications and Drawings.
b. Wastage on materials and labour.
c. Loading, transporting, unloading, handling/double handling, hoisting to all levels,
setting, fitting and fixing in position, protecting, disposal of debris and all other labour
necessary in and for the full and entire execution and for the job in accordance with the
contract documents, good practice and recognize principles.
d. Liabilities, obligations and risks arising out of Conditions of Contract.
e. All requirements of Specifications, whether such requirements are mentioned in the
item or not. The Specifications and Drawings where available, are to be read as
complimentary to and part of the Schedule of Quantities and any work called for in one
shall be taken as required for all.
f. In the event of conflict between Schedule of Quantities and other documents including
the Specifications, the most stringent shall apply. The interpretation of the Architect /
Engineer shall be final and binding.
g. Embedding conduits and accessories in walls and floors etc. during construction and /
or cutting chases (with chase cutting machine) and making good the same as necessary
in the case of concealed conduit work. Ready Mix Sand Cement Plaster for Chase filling
in Block Works & Non shrink Grout Material to be used for filling grooves in RCC
structure walls
GI Box Should Application of Zinc Chromate layer or equivalent anti-corrosive coat on GI
Third Party Test for each Source of Material such Conduit, Wires
S.No Description UOM QTY RATES AMOUNT
All equipment's, quantities and technical data indicated in this Schedule are for the
Contractor’s guidance only, these are based on the documents prepared by the Services
Consultant. This schedule must be read in conjunction with other documents. The
Contractor shall be paid for the actual quantity of work executed by him in accordance
with the approved Shop Drawings at the contract rates.
This Schedule shall be fully priced and the extensions and totals duly checked. The rates
for all items shall be filled in INK including NIL items.
No alteration whatsoever is to be made to the text or quantities of this Schedule unless
such alteration is authorised in writing by Services Consultant. Any such alterations,
notes or additions shall, unless authorized in writing, be disregarded when tender
documents are considered.
In the event of an error occurring in the amount of the Schedule, as a result of wrong
extension of the unit rate and quantity, the unit rate quoted by the tenderer shall be
regarded as firm and the extensions shall be amended on the basis of rates.
Any error in totaling in the amount column and in carrying forward total shall be
corrected. Any error, in description or in quantity, omission of items from this Schedule
shall not vitiate this Contract but shall be corrected and deemed to be variation required
by the Services Consultant/Project Manager.
The Contractor shall procure and bring Materials/Equipment to the site only on the basis
of drawings approved for construction and shop drawings and not on the basis of
Schedule of Quantities which are approximate only. This also applies to the Contractor’s
requisition for Owner supplied materials.
The unit rate for all local equipment or materials shall include cost of equipment and
materials including all taxes and duties and also including forwarding, freight, insurance
and transport into Contractor’s store at site, storage, installation, testing, balancing,
commissioning and other works required.
A CIRCUIT CUM POINT WIRING WITH SLAB & WALL CODUTING & BOXING
S.No Description UOM QTY RATES AMOUNT
The rates for all point wiring items shall also include supplying, fixing , Testing &
Commssinng of the following:
Conduits, conduit specials, PVC bushes and other fittings.
Approved GI saddles and grouting the same for exposed conduit work.
1.2 mm thick Outlet boxes and junction box.
All fixing accessories such as clips, brass screws etc.
All work necessary for wiring a point circuit of any length from the Final Distribution
Board to connector via switch and shall include the circuit wiring also except where
Embedding conduits and accessories in walls and floors etc. during construction and /
or cutting chases (with chase cutting machine) and making good the same as
necessary in the case of concealed conduit work.
Modular Switch, socket outlet with cover plateand necessary blank plates wherever
FRLS copper conductor stranded flexible wire of Green colour with yellow bands for
earthing of fixtures, outlet boxes and third pin of socket outlet.
Preparing of outlet boxes and junction boxes where ever damaged.
All wires shall be FRLS copper conductor stranded flexible 1100 volts grade and shall be
of approved make.
All sockets shall be shuttered type and with earth terminal.
Separate neutral and earthing wire shall be provided for each circuit.
CIRCUIT CUM POINT WIRING With SLAB & WALL CONDUITING AND BOXING
S.No Description UOM QTY RATES AMOUNT
Primary Point wiring for switch board controlled light points with 2 x 1.5 sq.mm FRLS
PVC insulated copper wire and earthing with 1.5 sq.mm. insulated copper wire in heavy
duty 25mm rigid PVC conduit, including clearance of pipe choking as required, providing
& fixing of modular switches as specified complete with modular plate in existing MS
boxes of suitable sizes with fish wire of size 2 mm (14 SWG) provided along with
conduit.. (first point shall be used from 1.5 sqmm 1100V grade FR PVC insulated copper
wires & looping with 1.5 sqmm). The cost of circuit wiring with 2 x 1.5 Sqmm + 1 x 1.5
Sqmm PVC insulated copper conductor 1100 Volts grade wires shall be included in the
cost of point wiring complete with all accessories.
One point controlled by one no. 6 amps switch.
Secondary Light Points.(Same above Item No. 1 but Loop Points.) Nos. 120 650 78000
2 Same as above item No. 1.0 but with 2 Light Controlled with Two (2) nos. 2-way switches Nos. 40 1100 44000
Ponit Wiring for Ceiling Fan Points with 1.5 sq.mm FRLS PVC insulated copper
conductor 1100 Volts grade stranded flexible wires in Existing concealed/surface
mounted heavy duty 25mm dia PVC Conduit & 1.2mm thick GI box. Supply & fixing of 6
Amps switch and 300 Watts electronic (modular) fan regulator of approved make in
1.2mm thick GI box and earthing the fan and outlet box with 1.5 sq. mm. PVC
insulated copper conductor stranded flexible wire.
Point Wiring for Exhaust fan points with 1.5 sq. mm. FR insulated copper conductor 1100
volts grade stranded flexible wires in Existing concealed/surface mounted heavy duty
25mm dia PVC Conduit & 1.2mm thick GI box. Supply & fixing of 6 Amps flush mounted
4 switch at the normal switch level (near entrance) in 1.2 mm thick GI box and 6 amps 3 Nos. 120 825 99000
pin flush mounted socket with child protection shutter out of near exhaust fan and
earthing of exhaust fan through the third pin of the socket outlet and GI box with 1.5 sq.
mm. PVC insulated copper conductor flexible wire.
Ponit Wiring for single phase and neutral 6 amps socket outlet for RO with 1.5 sq.mm
FR PVC insulated copper conductor 1100 volts grade stranded flexible wires in Existing
concealed/surface mounted medium duty 25mm dia PVC Conduit & 1.2mm thick GI
box.Supply & fixing of 6 amps 5 pin socket of approved make colour and design in
1.2mm thick GI box with grid plate and earthing of third pin of the socket outlet and the
GI box with 1.5 Sq.mm PVC insulated copper conductor stranded flexible wire.
S.No Description UOM QTY RATES AMOUNT
Ponit Wiring for single phase and neutral 6 amps switch socket outlet with 1.5 sq.mm FR
PVC insulated copper conductor 1100 volts grade stranded flexible wires in
concealed/surface mounted heavy duty 25mm dia PVC Conduit & 1.2mm thick GI box.
supply & fixing of 6 amps 5 pin switched socket of approved make colour and design in
6 1.2mm thick GI box with grid plate and earthing of third pin of the socket outlet and the Nos. 340 875 297500
GI box with 1.5 Sq.mm PVC insulated copper conductor stranded flexible wire. (Looping
shall be done with 3 Nos. 1.5 Sq.mm copper wire).
(Looped to lighting circuit as shown in drawing)
Same above Item No. 5 but Loop Points. Nos. 40 800 32000
Ponit Wiring for single phase and neutral 16 amps switch socket outlet with 4.0 sq.mm
FR PVC insulated copper conductor 1100 volts grade stranded flexible wires in Existing
concealed/surface mounted medium duty 25mm dia PVC Conduit & 1.2mm thick GI box.
7 Supply & fixing of 16 amps 6 pins switched socket of approved make colour and design Nos. 100 1600 160000
in 1.2mm thick GI box with grid plate and earthing of third pin of the socket outlet and the
GI box with 2.5 Sq.mm PVC insulated copper conductor stranded flexible wire. (Looping
shall be with 2.5 Sq.mm copper wire).
Wiring for Call bell points with 1.5mm2 FRLS PVC insulated, 1100V grade stranded
copper conductor wire in Existing concealed/surface mounted heavy duty 25mm dia
8 PVC Conduit & 1.2mm thick GI box.Supply & fixing of modular switche, plate & buzzer, Nos. 20 950 19000
1.2mm thick GI box, and earthing with 1.5 Sqmm PVC insulated green copper wire
complete with all accessories as required.
Point Wiring for single phase and neutral 16 amps switch socket outlet for Geaser with
4.0 sq.mm FRLS PVC insulated copper conductor 1100 volts grade stranded flexible
wires in Existing concealed/surface mounted heavy duty 25mm dia PVC Conduit &
9 1.2mm thick GI box. Supply & fixing of 16 amps 6 pins switched socket of approved Nos. 120 1700 204000
make colour and design in 1.2mm thick GI box with grid plate and earthing of third pin of
the socket outlet and the GI box with 2.5 Sq.mm PVC insulated copper conductor
stranded flexible wire. (Loop From A.C Point)
S.No Description UOM QTY RATES AMOUNT
Wiring for single phase and neutral for A/C with 4.0 sq.mm FRLS PVC insulated copper
conductor 1100 volts grade stranded flexible wires in Existing concealed/surface
mounted medium duty 25mm dia PVC Conduit & 1.2mm thick GI box. Supply & fixing of
20A 6 Pin outlet with mcb of approved make colour and design in 1.2mm thick GI box
with grid plate and earthing of third pin of the socket outlet and the GI box with 2.5
Sq.mm PVC insulated copper conductor stranded flexible wire.
Supply, installation, testing & commissioning of RG006 co-axial TV modular outlet in one
module plateRG006 co-axial TV signal cable in existing PVC conduit for TV modular
outlet including in existing outlet box for TV sockets with earth point, concealed or
surface mounted as required including necessary civil work such as chase cutting and
making good including clearance of pipe choking as required from Points inside Flat to
Supply, installation, testing & commissioning of RJ-11 Telephone modular outlet in one
module plate in existing outlet box with 2 pair, 0.61mm dia tinned copper conductor,
12 PVC insulated sheathed unarmoured telephone wire in existing PVC conduit including Nos. 120 650 78000
clearance of chocking pipe, and complete in all respects as required from Points inside
Flat to LV Shaft.
SUBMAIN WIRING WORK
Supply, laying, testing & commissioning of wiring with FR PVC insulated stranded copper
conductor wire 660/1100 V grade in existing surface / recessed conduit including
ferruling, terminations at both ends with suitable lugs, hylem pull box cover etc. complete
as required for the following
4 x 10mm2 Cu. Wire + 2 x 4.0 Sqmm Cu. Stranded green PVC insulated Earth wire in
existing conduit (Mentioned wires to be laid in single length without any joint)
4x16mm2 Cu. Wire + 2 x 10 Sqmm Cu. Stranded green PVC insulated Earth wire in
existing conduit (Mentioned wires to be laid in single length without any joint)
DISTRIBUTION BOARD /LV BOX
S.No Description UOM QTY RATES AMOUNT
Supply ,Installation, Dressing, testing and commissioning of the following FDB's pre
fabricated out of 1.2 mm thick CRCA sheet steel, dust and vermin proof, double door
construction, powder coated with approved shade and segregate phases. The Scope of
work shall include fixing of distribution boards with ready mix cement mortar in
Existing DB niche & for surface mounting with Screw/ fastner alongwith chase filling of
14 conduits in block work with ready mix cement
plaster & non shrik grout in RCC walls . The connection of DB by using conduit (including
accessories if any) with existing conduit
(with existing conduit left in DB cutout/ DB Niche ) and making good/complete in all
respect.Approved lockable cover with padlocking arrangement, recessed in wall or
surface mounted final distribution boards of the following description:
S.No Description UOM QTY RATES AMOUNT
Supply, installation, testing and commissioning of necessary MCB's B/ C series &
minimum 10kA breaking capacity, 2 Pole MCB's etc. including dressing, ferruling,
thimbling of wires etc. complete as per specifications and details as follows:
(Without Double Door D.B. Enclosure box )
C. 18 Nos. 6A/10A/16A/20A/25A SP MCB's, as specified in drawings & as required.
D. 6 WAY TPN DB as described above.
E. Blanker as required
F . Bus bar:100A TPN copper bus bar
G. Neutral link:Separate for each phase.
H. Earthing:Suitable for 12 Nos. outgoing.
Supply, installation, testing and commissioning of ONT box 450x300 mm etc. including
dressing, ferruling, thimbling of wires etc. complete as per specifications
3 LIGHTING & POWER DB for Common /Basement Area
TPN DB with 12 No. 10/16/20/25/32 SP MCB’s with 3 No. 40 amps DP RCCB of 30 mA leakage
current including 1 No.40 amps 4 Pole MCB as incomer. (Base Rate - Rs)
15.00 EARTHING INSTALLATION (FOR DISTRIBUTION SYSTEMS)
Rates shall also include the following :
All fixing accessories such as brass saddles, brass screws rawl plugs etc.
Jointing by rivetting and brazing after rivetting in case of copper and welding / bolting in case of
Cutting chases holes and making good the same wherever required.
S.No Description UOM QTY RATES AMOUNT
Effecting adequate and proper interconnections.
Use of copper thimbles.
Earthing system shall comply to IS:3043-1987.
All earthing pits shall be interconnected.
All equipment motors, DB’s, panels to be connected on either ends (double earthing) with suitable
Not:- Copper purity -90% for Plates & 95% for strips.
1.00 EARTHING INSTALLATION (FOR DISTRIBUTION SYSTEMS)
Supplying, fixing, testing and commissioning of following bare Copper/GI tapes including all
necessary fixing accessories and effecting connections.
1.30 6 SWG GI wire Meter 300 65 19500
Providing, laying, testing and commissioning of 600 x 600 x 3.15 mm thick Cu. electrode, with 2
nos. 32 X 6 mm CU strips from earth electrode to inspection chamber, 50 mm dia medium class
GI pipe, CI funnel with 20 gauge GI wire mesh, masonry chamber 450 x 450 mm with concrete
base CI / Heavy duty chequered plate manhole cover dia 560 mm heavy duty with frame painted
with bitumastic paint and packing with mixtures of charcoal and common salt around plate
electrode including excavation and backfilling of all kinds of earth , masonry work , connecting
the earth pit with earthing grid with bitumin covering of joints , all work as per IS:3043 complete
S.No Description UOM QTY RATES AMOUNT
Providing, laying, testing and commissioning of 600 x 600 x 6.3 mm thick GI electrode, with 2
nos. 50 X 6 mm GI strips from earth electrode to inspection chamber, 50 mm dia medium class GI
pipe, CI funnel with 20 gauge GI wire mesh, masonry chamber 450 x 450 mm with concrete base
3.00 CI / Heavy duty chequered plate manhole cover dia 560 mm heavy duty with frame painted with Nos 6 12560 75360
bitumastic paint and packing with mixtures of charcoal and common salt around plate electrode
including excavation and backfilling of all kinds of earth , masonry work , connecting the earth pit
with earthing grid with bitumin covering of joints , all work as per IS:3043 complete as required.
The cable management system shall comprise:
1 Ladder cable trays and supports.
2 Perforated cable trays and supports.
3 Surface mounted wire ducts with brackets / supports.
All cuts/perforations/folded sections where contact with wires/cables in expected shall be burr
5 The materials shall conform to relevant IS / BS standards for the category / application specified.
The cable tray shall be factory built. cable tray joints must be factory fabricated.Cable tray Only
cutting to achieve assembly system length shall be permitted at site.
Accurate fabrication formed section with tolerances of + 2 mm on width and + 5 mm on length
Dimensional and general arrangement drawing of the system are expected to be provided by
tenderer / cable tray / duct supplier.
S.No Description UOM QTY RATES AMOUNT
9 The system shall be designed for installation with a temperature classification of + 60 deg.C.
10 The cable tray/duct systems shall be suitable for against corrosion.
11 Details of fixing supports etc. shall be submitted for approval.
12 Paint shade should be siemens grey
Suspension should be with twin thread rod & MS angle at base for below 450mm size cable tray
and above 450mm size MS angle as base and suspenders
G FIRE ALARM SYSTEM
The rates shall include all components that may be required to make the installation complete in
all respects such as :
i. Suitable length connecting wires where called for.
ii. Internal wiring between accessories.
iii. Bonding with earth wires.
iv. Drilling holes in supports wherever require.
v Any supporting require for installation of detector , Speaker & GI Flexible pipe.
S.No Description UOM QTY RATES AMOUNT
Supply installation testing and commissioning of Micro processor based 2 wire fault tolerat loop,
HYBIRD 10 loop ( Devices Capacity 250 addressable units per loop ) Fire alarm/detection
control panel. The panel shall be able to give Pin Point location of all fire/fault conditions of
addressable units via the address codes. Further, the panel must be able to automatically switch
ON respective control module when ever any alarm is triggered, The panel shall have rectifier,
Loop cards, with 4.7 inch Graphical touch Screen LCD display along with LED Zonal indicators
event historical logging facility & Fire/Fault Signal with address and analog output. The panel
shall be duly backed up with 24 volt SMF batteries capable of running for a minimum of 24
hours normal working and 30 minuts (minimum) during emergency with automatic battery charger
240 volt AC power supply. The panel shall have required power supply for public address system
with hooter and Talk back Communication. 4007 ES UL Listed / FM approved. Battery To Be
precured locally by Client.
Supply installation testing and commissioning of UL/EN listed addressable plug-in type optical
(photoelectric) Smoke detectors as per detailed specifications including base plate mounting
accessories with end of line resistance complete as required. AD 338-2L, LPCB Approved (at
Supply installation testing and commissioning of Recess/surface mounting dust and vermin proof
UL/EN listed Manual call station, with back box as approved by Engineer incharge for fixing of
the station, unbreakable glass cover mounting accessories etc. complete as per specifications and
as required. ( AD110-BL )
Supply installation testing and commissioning of Recess/surface mounting dust and vermin proof
8.13 Sounder/ Hooter, with back box as approved by Engineer incharge for fixing of the station, Nos 1 1450 1450
complete as per specifications and as required. UL Listed / FM Approved ( 49AO-WRF )
Supply ,installation , testing and commissioning of Addressable fault isolators, UL Listed / FM
Approved, 4090-9116
S.No Description UOM QTY RATES AMOUNT
Supply ,installation , testing and commissioning of telephonic Jack Plates with back Boxes as
required to complete.
Supply ,installation , testing and commissioning of Handsets for fire fighter communication
Supply, laying, testing and commissioning of 2.0 x 1.5 Sq. mm Cu wire in existing PVC / MS /
conduit complete with accessories etc. as required.
Supply & fixing of following sizes of PVC Heavy Duty conduit on surface and/or recess along
with the accessories including cutting the wall & making good the same in case of recessed
conduit including providing & fixing of MS suspenders for fixing of conduits above false ceiling
etc. as required with fish wire of size 2mm (14 SWG) provided along with conduit.
J PUBLIC ADDRESS SYSTEM
Supply, laying, testing and commissioning of 2.0 x 1.5 Sq. mm Cu wire in existing PVC / MS /
conduit complete with accessories etc. as required.
Supply & fixing of following sizes of PVC conduit on surface and/or recess along with the
accessories including cutting the wall & making good the same in case of recessed conduit
including providing & fixing of MS suspenders for fixing of conduits above false ceiling etc. as
required with fish wire of size 2mm (14 SWG) provided along with conduit.
S.No Description UOM QTY RATES AMOUNT
Supply ,installation , testing and commissioning of Fire Alarm sounder & speaker having an
8.26 audible range of 25 meters with line matching transformers, Ceiling Type complete as Meters 15 2400 36000
required. HNCL/06
Supply ,installation , testing and commissioning of Power / Booster Amplifier, 250 W integrated
PA (DVC) with PA Rack complete with 4 way selection switch with power supply + battery
8.28 charger + battery housing + Talk Back Master Station and battery . PA CONSOLE including Nos 1 65000 65000
Distribution rack and housing for amplifier, SMPS Power Supply, 05 Amp. 24v DC as required to
complete the system
Supply, Installation, Testing & Commissioning of Distribution rack and housing for amplifier,
SMPS Power Supply, 05 Amp. 24v DC as required to complete the system
Supplying & laying of following 1.1 KV grade XLPE insulated, PVC inner sheathed and PVC
outer sheathed Copper conductor armoured cables as per specification in existing trenches, cable
trays, ducts, clamped to wall with suitable clamps including, saddles fixing bolts, connecting
testing and commissioning.
K CCTV SYSTEM COMPONENT:
Supply, installation, testing and commissioning of UL/CE Listed CCTV Coloured Camera,1.3
megapixel (1280 x 960) high resolution,1/3” Progressive scan CMOS, 0.2 lux with 4/6 mm auto
iris lens or equivalent high definition, motion detection,120dB wide dynamic range, H.264 /
1 MPEG4 / MJPEG, Dual stream, Bit rate 32 Kbps-16Mbps, 2 way audio, 12 VDC ± 10%, PoE Nos 20 8500 170000
(802.3af), with ONVIF supported, in built HD card slot up to 32 GB, connectors complete as
required in dome shape fixed type for mounting recessed in false ceiling or mounted on wall
complete as per tender specifications required. (Hikvision/CP Plus/ Godrej)
Supply, installation, testing and commissioning of 32" totally flat colour LCD monitor to display
the required Nos. of Camera's in Multiscreen.
S.No Description UOM QTY RATES AMOUNT
Supply, installation,testing & commissioning of 32 channel DVR capable of handling upto 32
cameras with HD real time recording with camera upto 5 MP, pentaplex operation -
simentuneious view, record, play back, backup & remort monitering. should have auto discovery
of camera with no programmeing. Should have drive mirroring between upto 4 internal HDD's,
sports 4x sata HDD's upto 6TB, esata sport for 4 external drives. Should have remort access via
iOS, android, PC / MAC on cloud. (Hikvision/CP Plus/ Godrej)
5 Supply ,Installation,testing and commissioning of 6 TB Hard Disk (Storage capacity of 180 Days) Nos 1 24500 24500
Supply Installation, testing and commissioning of 6U Indoor Rack with accessories (For DVR ,
Switches at control room) .
Supply ,Installation ,termination, testing and commissioning of Cat 6 Cable including all
accessories as required to complete.
10 Supply installation testing & Commisioning of 5 KVA UPS with 30 min backup including Trolley Nos 1 140000 140000
Supply, installation, testing and commissioning of user Client control software ( web based
)complete along with PC as per spec with valid licenses. The software should enable the user to
view multiple cameras in any combination available on the network (maximum 16 Nos) along
with all necessary accessories.
Supply and fixing of ISI marked (IS:9537-part 3 & 3419) 2 mm thick PVC conduit in concealed /
exposed system in wall, ceiling or on floor including cutting of brick / rcc work, laying of conduit
and fixing it with M.S. hooks and then plastering with cement, sand motar finished to the level,
providing necessary sockets, bends, tees, junction boxes of required sizes etc as directed at site by
the engineer-in-charge with supply of all material labour and T & P required for proper
completion of work. conduit being laid either in concealed system in ceiling slab or wall or on
surface or under the frame of false ceiling including flexible conduits or through wooden partition
including clamping arrangements as required.
S.No Description UOM QTY RATES AMOUNT
b 25 mm dia. conduit (Heavy duty) Meters 300 165 49500
c 32 mm dia. conduit (Heavy duty) Meters 100 210 21000
Supplying, receiving, storing, handling, fixing, wiring for CCTV wiring using ISI marked (IS 694)
1100 Volts grade, PVC insulated, flexible, flame retardant low smoke (FRLS) copper conductor
wire, drawn in existing solid / flexible conduits / casing caping including connections to the
detectors, manual call points, hooters, response indicators, accessories, fire alarm control panel
etc. including termination with bottle type copper lugs, connectors etc as required to complete the
D PANEL & DISTRIBUTION BOARDS
4 DISTRIBUTION PANELS
Design, manufacture, supply,including supervision during installation, testing and commissioning
of following Panels fabricated out of 2 mm thick CRCA sheet steel fabricated, cubicle type Panel
dust and vermin proof complete with hinged and lockable doors . The Sheet Steel shall under go
minimum eight tank treatment followed by finishing treatment of powder coating with 70 micron
minimum thickness. All the panels shall be floor mounted and dead front construction complete
with interconnections.
a) The panels shall be FRONT operated, with cable entry from the top. Earth bus shall be part of
the panel.) (All MCB to be "C" Curve)
b) The following provisions shall be required to be made in the Distribution Panel as detailed below:
S.No Description UOM QTY RATES AMOUNT
i) All live accessible parts shall be shrouded with 1mm thick polycarbonate/3 mm thick FRP sheet
and all equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable
sleeves according to the colour code. SMC shrouds and busbar supports shall be used. All MCCB
door handle shall be interlocked and lockable in OFF position.
ii) Galvanised hardware with zinc passivation shall be used in fabrication of Switchboards.
iii) Suitable Aluminium earth bus to be provided throughout the length of Switchboards.
iv) All indication lamps / illuminated push buttons shall be LED type.
v) Coil of all motor starters shall be fed from 440 V / 230 V Control Transformer.
vi) 2A SP MCBs shall be used as backup protections.
vii) All MCCBs shall be variable plug setting type with thermal magnetic up to & including 400 A
rating and with microprocessor based releases above 400 A rating, line load reversibility, Ics =
100% Icu,& rotary handle.
viii) All control& power wiring shall be broughtout upto the cable alley in the terminal blocks.
ix) An approval shall be taken for each panel before manufacturing.
x) Provision of one 6/16 amp socket & compartment lighting for each vertical section of main panel.
xi) Illuminated push button on Starter Panels of Pumps.
aa) Interlocking / Auto start command terminals for Starter panels. All Ventilation & pressurisation
fans shall be interlocked with Fire Alarm Panel as per given logic.
ab) All breaking Capacity for MCCB to be Ics=100%Icu.
ac) All MCB to be C Curve
COMMON AREA PANEL
IP Rating : IP 42
1 No. 100 A 35 KA, 4P MCCB of motor duty (Adjustable Magnetic release upto 250A MCCB OR
Micro-Processor based release above 250A MCCB). MCCB shall have 1NO + 1NC auxiliary contacts
+ a trip contact.
Incomer Metering & Indication:
S.No Description UOM QTY RATES AMOUNT
415V / √3 / 110V/ √3 PT's, Cast Resin type, 3 Phase for metering & indications, suitable rated 6A,
TP MPCB of the fault withstand capacity as of the panel on the primary side of PT & suitable rated
6A, TP MCB on the secondary side of PT. This metering PT shall be of Class-1 accuracy.
R,Y,B phase indication lamps (110V) LED Type
ON' & Trip indication lamps (110V) LED Type
Cast resin metering CT's for each phase of class-1 accuracy & of suitable burden & ratio
1 No. Digital VAF + PF Meter (110V) (With RS 485 Port)
100 A, TPN Aluminium Bus bars of electrolytic grade with heat shrinkable sleeve 35 KA.
1 Nos. 100/70 A 35 KA, 4P, MCCB's, motor duty for Lift Panel of Tower.
2 No. 100/32 A 35 KA, 4P, MCCB's, Common Area DB at Tower.
Vendor to ensure selection of MCCB & MCB through cascading effect to mitigate the
prospective fault circuit current.
Common Area Panel as Described Above. Nos 1 125000 125000
Meter Board Panel
Design, manufacture, supply,including supervision during installation, testing and commissioning
of following Panels fabricated out of 2 mm thick CRCA sheet steel fabricated, cubicle type Panel
dust and vermin proof complete with hinged and lockable doors . The Sheet Steel shall under go
minimum eight tank treatment followed by finishing treatment of powder coating with 70 micron
minimum thickness. All the panels shall be floor mounted and dead front construction complete
with interconnections.
a) The panels shall be FRONT operated, with cable entry from the top. Earth bus shall be part of
the panel.) (All MCB to be "C" Curve)
S.No Description UOM QTY RATES AMOUNT
b) The following provisions shall be required to be made in the Distribution Panel as detailed below:
i) All live accessible parts shall be shrouded with 1mm thick polycarbonate/3 mm thick FRP sheet
and all equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable
sleeves according to the colour code. SMC shrouds and busbar supports shall be used. All MCCB
door handle shall be interlocked and lockable in OFF position.
ii) Galvanised hardware with zinc passivation shall be used in fabrication of Switchboards.
iii) Suitable Aluminium earth bus to be provided throughout the length of Switchboards.
iv) All indication lamps / illuminated push buttons shall be LED type.
v) Coil of all motor starters shall be fed from 440 V / 230 V Control Transformer.
vi) 2A SP MCBs shall be used as backup protections.
vii) All MCCBs shall be variable plug setting type with thermal magnetic up to & including 400 A
rating and with microprocessor based releases above 400 A rating, line load reversibility, Ics =
100% Icu,& rotary handle.
viii) All control& power wiring shall be broughtout upto the cable alley in the terminal blocks.
ix) An approval shall be taken for each panel before manufacturing.
x) Provision of one 6/16 amp socket & compartment lighting for each vertical section of main panel.
xi) Illuminated push button on Starter Panels of Pumps.
aa) Interlocking / Auto start command terminals for Starter panels. All Ventilation & pressurisation
fans shall be interlocked with Fire Alarm Panel as per given logic.
ab) All breaking Capacity for MCCB to be Ics=100%Icu.
ac) All MCB to be C Curve
Meter Board (4 Meters):
Incoming Cable connection link work & Bus Bars:
4 Pole 100 Amp 25 KA Aluminium link work & bus bars with heat shrinkable sleeves.
LED type R,Y,B Phase Indication lamps with suitable rating CTs.
2 Nos.63 A, 4P, MCB's
S.No Description UOM QTY RATES AMOUNT
2 Nos. Dual source KWH meter, Class-1 accuracy, (Direct reading type without CT's) 0-80A, 3
Phase, 4 Wire with auto cut-off, With pre-paid facility with room unit and complete with internal
HR FRLS PVC Insulated unsheathed flexible copper conductor wiring of adequate size and input &
output wiring terminal blocks as required.
Meter Board (2 Meters) as described above. Nos 6 85000 510000
MAIN & SUB MAIN CABLES
1.0 Supply of following sizes of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC
sheathed armoured cable conforming to relevant IS (Cable shall be purchased only after approval of cable
schedule by architect / consultant)
1.1 3.5 core, 300 sq.mm. Meter 1446
1.3 3.5 core, 185 sq.mm. Meter 936
2.0 Supply and making end termination with brass single compression glands and aluminium lugs following
sizes of XLPE insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade of the
following sizes as required.
S.No Description UOM QTY RATES AMOUNT
Supplying, installing by suspension on ceiling/along the wall, testing and commissioning of following
capacity Sandwich Type Bus Duct (Outdoor Type) for use on 3 phase 4 wire 415 V, 50Hz A.C. supply with
metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm
thick steel sheet duly powder coated in convenient sections complete with 4 Nos. aluminium bus bars
having current density of 130 A/sq. cm at nominal current rating, necessary joints, elbow joints & expansion
joints and bends, fire barrier at each floor, provision of tapping at every meter, adopter box and copper
flexible for joints, continuous earthing with 2 Nos. aluminium strip of suitable size (one on each side)
including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing
system etc. as required
400 Amp Meter 17,562
2.0 END FEED UNIT-
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, Installation, Testing & Commissioning of
following End Feed Unit housing fabricated out of 14G CRCA powder coated (as approved) sheet steel for
the Rising Mains fitted with following MCCB. The End Feed Unit should complete with solid aluminium
links of rated capacity of MCCB to Rising Mains. The End Feed Unit should be complete with suitable size
of glands plate for incoming cables. All MCCB shall have Ics value of 50 KA. Each end feed unit shall have
a set of 3 nos. phase LED Type indicating lights with control fuses.
2.1 250 A, Isc = 50 kA for 1 second Set 2 85,600 171200
3.0 TAP OFF UNIT-
S.No Description UOM QTY RATES AMOUNT
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, Installation, Testing & Commissioning of
cubical type tap off unit box fabricated out of 2.0 mm thick CRCA sheet, dust and vermin proof, with hinged
detachable doors and painted front, comprising LED type indication lamps with toggle switches and 4 pole
MCCB terminated directly with tap off box with Bus Bar links on the incoming side and suitable for cable
connection on the outgoing side including making connections, interconnections, earthing complete as
required. All MCCB shall have Ics value of 36 KA and Thermal Magnetc release for over current & short
3.1 Tap Off Box with 160 Amp FP MCCB. 21,560 301840
4 Supply & fixing of end capTap Set 2 8,560 17120
SUPPLY & FIXING OF LIGHT FIXTURES & FANS INTERNAL LIGHTING-
1.0 Supply, Installation, Testing & Commissioning of 1x22 Watt LED Light Fixture surface mounted as per
technical specification. (Philips Make - Cat No BN021C LED20S PSU CDL GR) or equivalent fixture as per Nos 120 1035.85 124302
2.0 Supply, Installation, Testing & Commissioning of 10 W Surface Mounted LED down light Philips make cat
no - DN097B LED10S-6500 PSU WH) or equivalent fixture as per tender make. Nos 300 2192.28 657684
3.0 Supply, Installation, Testing & Commissioning of 15 W Recess Mounted LED down light Philips make cat
no - DN194B LED15S-6500 PSU WH) or equivalent fixture as per tender make. Nos 160 2978.25 476520
4.0 Supply, Installation, Testing & Commissioning of 1x10 Watt LED Light Fixture surface mounted as per
technical specification. (Philips Make - Cat No BN021C LED10S PSU CDL GR) or equivalent fixture as per Nos 60 749.65 44979
5.0 Supply, Installation, Testing & Commissioning of Light Fixture surface mounted. (Philips make cat no-
WT140 LED6S NW PSU S2 PC or equivalent.) Nos 60 1189.85 71391
6.0 Supply, Installation, Testing & Commissioning of GARRNET 12W LED BULB suitable for batten holder.
(Wipro Make or equivalent.) Nos 54 1407.77 76020
7.0 Supply, Installation, Testing & Commissioning of Bracket Light Fixture surface mounted. (Philips make cat
no- 30762 Delight or equivalent.) Nos 45 1598.08 71914
S.No Description UOM QTY RATES AMOUNT
8.0 Supply of following sizes of heavy duty exhaust fan for single phase 230 volt, 50HZ AC supply complete
with motor, blades, frame, bracket, louver/ shutter etc as required. (HavellS Make, Cat No - Ventil Air-DX
or equivalent.)
8.1 250 mm Exhaust Fan Nos 120 2811.18 337342
9.0 Supply of following sizes of ceiling fan complete with double ball bearing, motor, blades, downrod, canopy,
capacitor etc. suitable for operation on 230 volt, 50 Hz, A.C. supply complete as required. (Havells Make,
Cat No-ES-50 Premium 5 or equivalent.)
TOTAL OF ELECTRICAL CARRIED TO SUMMARY 89,79,185
NBCC (India) Limited
SCHEDULE OF QUANTITY
ELECTRICAL WORKS
S.No Description UOM QTY RATES AMOUNT
Nos of flats 20
Nos of Floors G+5
Nos of Towers 1
ELECTRICAL WORK
A POINT WIRING
The items given in this schedule are provisional. The Contractor shall be paid for the
actual quantity of work executed as measured at the site at the rates tendered. The
Owner reserves the right to increase or decrease any of the quantities, or to omit
totally any item of work. Any claim by the Contractor on these accounts will not be
All the items of work given in this schedule of quantities shall be executed strictly in
accordance with the latest Indian Standard Specifications and the requirements of the
Electricity Supply Authority read in conjunction with the relevant drawings and
Specifications.
The Contractor shall visit the site and shall satisfy himself as to the conditions under
which the work is to be performed. He shall also check and ascertain the location of
any existing structure or equipment or any other situation which may affect the work.
No extra claim as a consequence of ignorance or on ground of insufficient
description will be allowed at a later date.
All equipment and material shall be BIS complete
vendor drawings shall be approved by the consultant before fabrication work starts.
All Testing and Commissioning shall be as per relevant IS for equipment and
IS:732:1989 for the installation. All these testing records are to be maintained.
S.No Description UOM QTY RATES AMOUNT
The rate for each item of work included in the Schedule of Quantities shall, unless
expressly stated otherwise, include cost of :
a. All materials, fixing materials, accessories, appliances tools, plants, equipment,
transport, labour and incidentals required in preparation for and in the full and entire
execution, testing, balancing, commissioning and completion of work called for in the
item and as per Specifications and Drawings.
b. Wastage on materials and labour.
c. Loading, transporting, unloading, handling/double handling, hoisting to all levels,
setting, fitting and fixing in position, protecting, disposal of debris and all other labour
necessary in and for the full and entire execution and for the job in accordance with the
contract documents, good practice and recognize principles.
d. Liabilities, obligations and risks arising out of Conditions of Contract.
e. All requirements of Specifications, whether such requirements are mentioned in the
item or not. The Specifications and Drawings where available, are to be read as
complimentary to and part of the Schedule of Quantities and any work called for in one
shall be taken as required for all.
f. In the event of conflict between Schedule of Quantities and other documents including
the Specifications, the most stringent shall apply. The interpretation of the Architect /
Engineer shall be final and binding.
g. Embedding conduits and accessories in walls and floors etc. during construction and /
or cutting chases (with chase cutting machine) and making good the same as necessary
in the case of concealed conduit work. Ready Mix Sand Cement Plaster for Chase filling
in Block Works & Non shrink Grout Material to be used for filling grooves in RCC
structure walls
GI Box Should Application of Zinc Chromate layer or equivalent anti-corrosive coat on GI
Third Party Test for each Source of Material such Conduit, Wires
S.No Description UOM QTY RATES AMOUNT
All equipment's, quantities and technical data indicated in this Schedule are for the
Contractor’s guidance only, these are based on the documents prepared by the Services
Consultant. This schedule must be read in conjunction with other documents. The
Contractor shall be paid for the actual quantity of work executed by him in accordance
with the approved Shop Drawings at the contract rates.
This Schedule shall be fully priced and the extensions and totals duly checked. The rates
for all items shall be filled in INK including NIL items.
No alteration whatsoever is to be made to the text or quantities of this Schedule unless
such alteration is authorised in writing by Services Consultant. Any such alterations,
notes or additions shall, unless authorized in writing, be disregarded when tender
documents are considered.
In the event of an error occurring in the amount of the Schedule, as a result of wrong
extension of the unit rate and quantity, the unit rate quoted by the tenderer shall be
regarded as firm and the extensions shall be amended on the basis of rates.
Any error in totaling in the amount column and in carrying forward total shall be
corrected. Any error, in description or in quantity, omission of items from this Schedule
shall not vitiate this Contract but shall be corrected and deemed to be variation required
by the Services Consultant/Project Manager.
The Contractor shall procure and bring Materials/Equipment to the site only on the basis
of drawings approved for construction and shop drawings and not on the basis of
Schedule of Quantities which are approximate only. This also applies to the Contractor’s
requisition for Owner supplied materials.
The unit rate for all local equipment or materials shall include cost of equipment and
materials including all taxes and duties and also including forwarding, freight, insurance
and transport into Contractor’s store at site, storage, installation, testing, balancing,
commissioning and other works required.
A CIRCUIT CUM POINT WIRING WITH SLAB & WALL CODUTING & BOXING
S.No Description UOM QTY RATES AMOUNT
The rates for all point wiring items shall also include supplying, fixing , Testing &
Commssinng of the following:
Conduits, conduit specials, PVC bushes and other fittings.
Approved GI saddles and grouting the same for exposed conduit work.
1.2 mm thick Outlet boxes and junction box.
All fixing accessories such as clips, brass screws etc.
All work necessary for wiring a point circuit of any length from the Final Distribution
Board to connector via switch and shall include the circuit wiring also except where
Embedding conduits and accessories in walls and floors etc. during construction and /
or cutting chases (with chase cutting machine) and making good the same as
necessary in the case of concealed conduit work.
Modular Switch, socket outlet with cover plateand necessary blank plates wherever
FRLS copper conductor stranded flexible wire of Green colour with yellow bands for
earthing of fixtures, outlet boxes and third pin of socket outlet.
Preparing of outlet boxes and junction boxes where ever damaged.
All wires shall be FRLS copper conductor stranded flexible 1100 volts grade and shall be
of approved make.
All sockets shall be shuttered type and with earth terminal.
Separate neutral and earthing wire shall be provided for each circuit.
CIRCUIT CUM POINT WIRING With SLAB & WALL CONDUITING AND BOXING
S.No Description UOM QTY RATES AMOUNT
Primary Point wiring for switch board controlled light points with 2 x 1.5 sq.mm FRLS
PVC insulated copper wire and earthing with 1.5 sq.mm. insulated copper wire in heavy
duty 25mm rigid PVC conduit, including clearance of pipe choking as required, providing
& fixing of modular switches as specified complete with modular plate in existing MS
boxes of suitable sizes with fish wire of size 2 mm (14 SWG) provided along with
conduit.. (first point shall be used from 1.5 sqmm 1100V grade FR PVC insulated copper
wires & looping with 1.5 sqmm). The cost of circuit wiring with 2 x 1.5 Sqmm + 1 x 1.5
Sqmm PVC insulated copper conductor 1100 Volts grade wires shall be included in the
cost of point wiring complete with all accessories.
One point controlled by one no. 6 amps switch.
Secondary Light Points.(Same above Item No. 1 but Loop Points.) Nos. 80 650 52000
2 Same as above item No. 1.0 but with 2 Light Controlled with Two (2) nos. 2-way switches Nos. 40 1100 44000
Ponit Wiring for Ceiling Fan Points with 1.5 sq.mm FRLS PVC insulated copper
conductor 1100 Volts grade stranded flexible wires in Existing concealed/surface
mounted heavy duty 25mm dia PVC Conduit & 1.2mm thick GI box. Supply & fixing of 6
Amps switch and 300 Watts electronic (modular) fan regulator of approved make in
1.2mm thick GI box and earthing the fan and outlet box with 1.5 sq. mm. PVC
insulated copper conductor stranded flexible wire.
Point Wiring for Exhaust fan points with 1.5 sq. mm. FR insulated copper conductor 1100
volts grade stranded flexible wires in Existing concealed/surface mounted heavy duty
25mm dia PVC Conduit & 1.2mm thick GI box. Supply & fixing of 6 Amps flush mounted
4 switch at the normal switch level (near entrance) in 1.2 mm thick GI box and 6 amps 3 Nos. 60 825 49500
pin flush mounted socket with child protection shutter out of near exhaust fan and
earthing of exhaust fan through the third pin of the socket outlet and GI box with 1.5 sq.
mm. PVC insulated copper conductor flexible wire.
Ponit Wiring for single phase and neutral 6 amps socket outlet for RO with 1.5 sq.mm
FR PVC insulated copper conductor 1100 volts grade stranded flexible wires in Existing
concealed/surface mounted medium duty 25mm dia PVC Conduit & 1.2mm thick GI
box.Supply & fixing of 6 amps 5 pin socket of approved make colour and design in
1.2mm thick GI box with grid plate and earthing of third pin of the socket outlet and the
GI box with 1.5 Sq.mm PVC insulated copper conductor stranded flexible wire.
S.No Description UOM QTY RATES AMOUNT
Ponit Wiring for single phase and neutral 6 amps switch socket outlet with 1.5 sq.mm FR
PVC insulated copper conductor 1100 volts grade stranded flexible wires in
concealed/surface mounted heavy duty 25mm dia PVC Conduit & 1.2mm thick GI box.
supply & fixing of 6 amps 5 pin switched socket of approved make colour and design in
6 1.2mm thick GI box with grid plate and earthing of third pin of the socket outlet and the Nos. 340 875 297500
GI box with 1.5 Sq.mm PVC insulated copper conductor stranded flexible wire. (Looping
shall be done with 3 Nos. 1.5 Sq.mm copper wire).
(Looped to lighting circuit as shown in drawing)
Same above Item No. 5 but Loop Points. Nos. 40 800 32000
Ponit Wiring for single phase and neutral 16 amps switch socket outlet with 4.0 sq.mm
FR PVC insulated copper conductor 1100 volts grade stranded flexible wires in Existing
concealed/surface mounted medium duty 25mm dia PVC Conduit & 1.2mm thick GI box.
7 Supply & fixing of 16 amps 6 pins switched socket of approved make colour and design Nos. 60 1600 96000
in 1.2mm thick GI box with grid plate and earthing of third pin of the socket outlet and the
GI box with 2.5 Sq.mm PVC insulated copper conductor stranded flexible wire. (Looping
shall be with 2.5 Sq.mm copper wire).
Wiring for Call bell points with 1.5mm2 FRLS PVC insulated, 1100V grade stranded
copper conductor wire in Existing concealed/surface mounted heavy duty 25mm dia
8 PVC Conduit & 1.2mm thick GI box.Supply & fixing of modular switche, plate & buzzer, Nos. 20 950 19000
1.2mm thick GI box, and earthing with 1.5 Sqmm PVC insulated green copper wire
complete with all accessories as required.
Point Wiring for single phase and neutral 16 amps switch socket outlet for Geaser with
4.0 sq.mm FRLS PVC insulated copper conductor 1100 volts grade stranded flexible
wires in Existing concealed/surface mounted heavy duty 25mm dia PVC Conduit &
9 1.2mm thick GI box. Supply & fixing of 16 amps 6 pins switched socket of approved Nos. 60 1700 102000
make colour and design in 1.2mm thick GI box with grid plate and earthing of third pin of
the socket outlet and the GI box with 2.5 Sq.mm PVC insulated copper conductor
stranded flexible wire. (Loop From A.C Point)
S.No Description UOM QTY RATES AMOUNT
Wiring for single phase and neutral for A/C with 4.0 sq.mm FRLS PVC insulated copper
conductor 1100 volts grade stranded flexible wires in Existing concealed/surface
mounted medium duty 25mm dia PVC Conduit & 1.2mm thick GI box. Supply & fixing of
20A 6 Pin outlet with mcb of approved make colour and design in 1.2mm thick GI box
with grid plate and earthing of third pin of the socket outlet and the GI box with 2.5
Sq.mm PVC insulated copper conductor stranded flexible wire.
Supply, installation, testing & commissioning of RG006 co-axial TV modular outlet in one
module plateRG006 co-axial TV signal cable in existing PVC conduit for TV modular
outlet including in existing outlet box for TV sockets with earth point, concealed or
surface mounted as required including necessary civil work such as chase cutting and
making good including clearance of pipe choking as required from Points inside Flat to
Supply, installation, testing & commissioning of RJ-11 Telephone modular outlet in one
module plate in existing outlet box with 2 pair, 0.61mm dia tinned copper conductor,
12 PVC insulated sheathed unarmoured telephone wire in existing PVC conduit including Nos. 100 650 65000
clearance of chocking pipe, and complete in all respects as required from Points inside
Flat to LV Shaft.
SUBMAIN WIRING WORK
Supply, laying, testing & commissioning of wiring with FR PVC insulated stranded copper
conductor wire 660/1100 V grade in existing surface / recessed conduit including
ferruling, terminations at both ends with suitable lugs, hylem pull box cover etc. complete
as required for the following
4 x 10mm2 Cu. Wire + 2 x 4.0 Sqmm Cu. Stranded green PVC insulated Earth wire in
existing conduit (Mentioned wires to be laid in single length without any joint)
4x16mm2 Cu. Wire + 2 x 10 Sqmm Cu. Stranded green PVC insulated Earth wire in
existing conduit (Mentioned wires to be laid in single length without any joint)
DISTRIBUTION BOARD /LV BOX
S.No Description UOM QTY RATES AMOUNT
Supply ,Installation, Dressing, testing and commissioning of the following FDB's pre
fabricated out of 1.2 mm thick CRCA sheet steel, dust and vermin proof, double door
construction, powder coated with approved shade and segregate phases. The Scope of
work shall include fixing of distribution boards with ready mix cement mortar in
Existing DB niche & for surface mounting with Screw/ fastner alongwith chase filling of
14 conduits in block work with ready mix cement
plaster & non shrik grout in RCC walls . The connection of DB by using conduit (including
accessories if any) with existing conduit
(with existing conduit left in DB cutout/ DB Niche ) and making good/complete in all
respect.Approved lockable cover with padlocking arrangement, recessed in wall or
surface mounted final distribution boards of the following description:
S.No Description UOM QTY RATES AMOUNT
Supply, installation, testing and commissioning of necessary MCB's B/ C series &
minimum 10kA breaking capacity, 2 Pole MCB's etc. including dressing, ferruling,
thimbling of wires etc. complete as per specifications and details as follows:
(Without Double Door D.B. Enclosure box )
C. 18 Nos. 6A/10A/16A/20A/25A SP MCB's, as specified in drawings & as required.
D. 6 WAY TPN DB as described above.
E. Blanker as required
F . Bus bar:100A TPN copper bus bar
G. Neutral link:Separate for each phase.
H. Earthing:Suitable for 12 Nos. outgoing.
Supply, installation, testing and commissioning of ONT box 450x300 mm etc. including
dressing, ferruling, thimbling of wires etc. complete as per specifications
3 LIGHTING & POWER DB for Common /Basement Area
TPN DB with 12 No. 10/16/20/25/32 SP MCB’s with 3 No. 40 amps DP RCCB of 30 mA leakage
current including 1 No.40 amps 4 Pole MCB as incomer. (Base Rate - Rs)
15.00 EARTHING INSTALLATION (FOR DISTRIBUTION SYSTEMS)
Rates shall also include the following :
All fixing accessories such as brass saddles, brass screws rawl plugs etc.
Jointing by rivetting and brazing after rivetting in case of copper and welding / bolting in case of
Cutting chases holes and making good the same wherever required.
S.No Description UOM QTY RATES AMOUNT
Effecting adequate and proper interconnections.
Use of copper thimbles.
Earthing system shall comply to IS:3043-1987.
All earthing pits shall be interconnected.
All equipment motors, DB’s, panels to be connected on either ends (double earthing) with suitable
Not:- Copper purity -90% for Plates & 95% for strips.
1.00 EARTHING INSTALLATION (FOR DISTRIBUTION SYSTEMS)
Supplying, fixing, testing and commissioning of following bare Copper/GI tapes including all
necessary fixing accessories and effecting connections.
1.30 6 SWG GI wire Meter 150 65 9750
Providing, laying, testing and commissioning of 600 x 600 x 3.15 mm thick Cu. electrode, with 2
nos. 32 X 6 mm CU strips from earth electrode to inspection chamber, 50 mm dia medium class
GI pipe, CI funnel with 20 gauge GI wire mesh, masonry chamber 450 x 450 mm with concrete
base CI / Heavy duty chequered plate manhole cover dia 560 mm heavy duty with frame painted
with bitumastic paint and packing with mixtures of charcoal and common salt around plate
electrode including excavation and backfilling of all kinds of earth , masonry work , connecting
the earth pit with earthing grid with bitumin covering of joints , all work as per IS:3043 complete
S.No Description UOM QTY RATES AMOUNT
Providing, laying, testing and commissioning of 600 x 600 x 6.3 mm thick GI electrode, with 2
nos. 50 X 6 mm GI strips from earth electrode to inspection chamber, 50 mm dia medium class GI
pipe, CI funnel with 20 gauge GI wire mesh, masonry chamber 450 x 450 mm with concrete base
3.00 CI / Heavy duty chequered plate manhole cover dia 560 mm heavy duty with frame painted with Nos 6 12560 75360
bitumastic paint and packing with mixtures of charcoal and common salt around plate electrode
including excavation and backfilling of all kinds of earth , masonry work , connecting the earth pit
with earthing grid with bitumin covering of joints , all work as per IS:3043 complete as required.
The cable management system shall comprise:
1 Ladder cable trays and supports.
2 Perforated cable trays and supports.
3 Surface mounted wire ducts with brackets / supports.
All cuts/perforations/folded sections where contact with wires/cables in expected shall be burr
5 The materials shall conform to relevant IS / BS standards for the category / application specified.
The cable tray shall be factory built. cable tray joints must be factory fabricated.Cable tray Only
cutting to achieve assembly system length shall be permitted at site.
Accurate fabrication formed section with tolerances of + 2 mm on width and + 5 mm on length
Dimensional and general arrangement drawing of the system are expected to be provided by
tenderer / cable tray / duct supplier.
S.No Description UOM QTY RATES AMOUNT
9 The system shall be designed for installation with a temperature classification of + 60 deg.C.
10 The cable tray/duct systems shall be suitable for against corrosion.
11 Details of fixing supports etc. shall be submitted for approval.
12 Paint shade should be siemens grey
Suspension should be with twin thread rod & MS angle at base for below 450mm size cable tray
and above 450mm size MS angle as base and suspenders
G FIRE ALARM SYSTEM
The rates shall include all components that may be required to make the installation complete in
all respects such as :
i. Suitable length connecting wires where called for.
ii. Internal wiring between accessories.
iii. Bonding with earth wires.
iv. Drilling holes in supports wherever require.
v Any supporting require for installation of detector , Speaker & GI Flexible pipe.
S.No Description UOM QTY RATES AMOUNT
Supply installation testing and commissioning of Micro processor based 2 wire fault tolerat loop,
HYBIRD 10 loop ( Devices Capacity 250 addressable units per loop ) Fire alarm/detection
control panel. The panel shall be able to give Pin Point location of all fire/fault conditions of
addressable units via the address codes. Further, the panel must be able to automatically switch
ON respective control module when ever any alarm is triggered, The panel shall have rectifier,
Loop cards, with 4.7 inch Graphical touch Screen LCD display along with LED Zonal indicators
event historical logging facility & Fire/Fault Signal with address and analog output. The panel
shall be duly backed up with 24 volt SMF batteries capable of running for a minimum of 24
hours normal working and 30 minuts (minimum) during emergency with automatic battery charger
240 volt AC power supply. The panel shall have required power supply for public address system
with hooter and Talk back Communication. 4007 ES UL Listed / FM approved. Battery To Be
precured locally by Client.
Supply installation testing and commissioning of UL/EN listed addressable plug-in type optical
(photoelectric) Smoke detectors as per detailed specifications including base plate mounting
accessories with end of line resistance complete as required. AD 338-2L, LPCB Approved (at
Supply installation testing and commissioning of Recess/surface mounting dust and vermin proof
UL/EN listed Manual call station, with back box as approved by Engineer incharge for fixing of
the station, unbreakable glass cover mounting accessories etc. complete as per specifications and
as required. ( AD110-BL )
Supply installation testing and commissioning of Recess/surface mounting dust and vermin proof
8.13 Sounder/ Hooter, with back box as approved by Engineer incharge for fixing of the station, Nos 6 1450 8700
complete as per specifications and as required. UL Listed / FM Approved ( 49AO-WRF )
Supply ,installation , testing and commissioning of Addressable fault isolators, UL Listed / FM
Approved, 4090-9116
S.No Description UOM QTY RATES AMOUNT
Supply ,installation , testing and commissioning of telephonic Jack Plates with back Boxes as
required to complete.
Supply ,installation , testing and commissioning of Handsets for fire fighter communication
Supply, laying, testing and commissioning of 2.0 x 1.5 Sq. mm Cu wire in existing PVC / MS /
conduit complete with accessories etc. as required.
Supply & fixing of following sizes of PVC Heavy Duty conduit on surface and/or recess along
with the accessories including cutting the wall & making good the same in case of recessed
conduit including providing & fixing of MS suspenders for fixing of conduits above false ceiling
etc. as required with fish wire of size 2mm (14 SWG) provided along with conduit.
J PUBLIC ADDRESS SYSTEM
Supply, laying, testing and commissioning of 2.0 x 1.5 Sq. mm Cu wire in existing PVC / MS /
conduit complete with accessories etc. as required.
Supply & fixing of following sizes of PVC conduit on surface and/or recess along with the
accessories including cutting the wall & making good the same in case of recessed conduit
including providing & fixing of MS suspenders for fixing of conduits above false ceiling etc. as
required with fish wire of size 2mm (14 SWG) provided along with conduit.
Supply ,installation , testing and commissioning of Fire Alarm sounder & speaker having an
8.26 audible range of 25 meters with line matching transformers, Ceiling Type complete as Meters 5 2400 12000
required. HNCL/06
S.No Description UOM QTY RATES AMOUNT
Supply ,installation , testing and commissioning of Power / Booster Amplifier, 250 W integrated
PA (DVC) with PA Rack complete with 4 way selection switch with power supply + battery
8.28 charger + battery housing + Talk Back Master Station and battery . PA CONSOLE including Nos 1 65000 65000
Distribution rack and housing for amplifier, SMPS Power Supply, 05 Amp. 24v DC as required to
complete the system
Supply, Installation, Testing & Commissioning of Distribution rack and housing for amplifier,
SMPS Power Supply, 05 Amp. 24v DC as required to complete the system
Supplying & laying of following 1.1 KV grade XLPE insulated, PVC inner sheathed and PVC
outer sheathed Copper conductor armoured cables as per specification in existing trenches, cable
trays, ducts, clamped to wall with suitable clamps including, saddles fixing bolts, connecting
testing and commissioning.
K CCTV SYSTEM COMPONENT:
Supply, installation, testing and commissioning of UL/CE Listed CCTV Coloured Camera,1.3
megapixel (1280 x 960) high resolution,1/3” Progressive scan CMOS, 0.2 lux with 4/6 mm auto
iris lens or equivalent high definition, motion detection,120dB wide dynamic range, H.264 /
1 MPEG4 / MJPEG, Dual stream, Bit rate 32 Kbps-16Mbps, 2 way audio, 12 VDC ± 10%, PoE Nos 15 8500 127500
(802.3af), with ONVIF supported, in built HD card slot up to 32 GB, connectors complete as
required in dome shape fixed type for mounting recessed in false ceiling or mounted on wall
complete as per tender specifications required. (Hikvision/CP Plus/ Godrej)
Supply, installation, testing and commissioning of 32" totally flat colour LCD monitor to display
the required Nos. of Camera's in Multiscreen.
S.No Description UOM QTY RATES AMOUNT
Supply, installation,testing & commissioning of 32 channel DVR capable of handling upto 32
cameras with HD real time recording with camera upto 5 MP, pentaplex operation -
simentuneious view, record, play back, backup & remort monitering. should have auto discovery
of camera with no programmeing. Should have drive mirroring between upto 4 internal HDD's,
sports 4x sata HDD's upto 6TB, esata sport for 4 external drives. Should have remort access via
iOS, android, PC / MAC on cloud. (Hikvision/CP Plus/ Godrej)
5 Supply ,Installation,testing and commissioning of 6 TB Hard Disk (Storage capacity of 180 Days) Nos 1 24500 24500
Supply Installation, testing and commissioning of 6U Indoor Rack with accessories (For DVR ,
Switches at control room) .
Supply ,Installation ,termination, testing and commissioning of Cat 6 Cable including all
accessories as required to complete.
10 Supply installation testing & Commisioning of 5 KVA UPS with 30 min backup including Trolley Nos 1 140000 140000
Supply, installation, testing and commissioning of user Client control software ( web based
)complete along with PC as per spec with valid licenses. The software should enable the user to
view multiple cameras in any combination available on the network (maximum 16 Nos) along
with all necessary accessories.
Supply and fixing of ISI marked (IS:9537-part 3 & 3419) 2 mm thick PVC conduit in concealed /
exposed system in wall, ceiling or on floor including cutting of brick / rcc work, laying of conduit
and fixing it with M.S. hooks and then plastering with cement, sand motar finished to the level,
providing necessary sockets, bends, tees, junction boxes of required sizes etc as directed at site by
the engineer-in-charge with supply of all material labour and T & P required for proper
completion of work. conduit being laid either in concealed system in ceiling slab or wall or on
surface or under the frame of false ceiling including flexible conduits or through wooden partition
including clamping arrangements as required.
S.No Description UOM QTY RATES AMOUNT
b 25 mm dia. conduit (Heavy duty) Meters 300 165 49500
c 32 mm dia. conduit (Heavy duty) Meters 100 210 21000
Supplying, receiving, storing, handling, fixing, wiring for CCTV wiring using ISI marked (IS 694)
1100 Volts grade, PVC insulated, flexible, flame retardant low smoke (FRLS) copper conductor
wire, drawn in existing solid / flexible conduits / casing caping including connections to the
detectors, manual call points, hooters, response indicators, accessories, fire alarm control panel
etc. including termination with bottle type copper lugs, connectors etc as required to complete the
D PANEL & DISTRIBUTION BOARDS
4 DISTRIBUTION PANELS
Design, manufacture, supply,including supervision during installation, testing and commissioning
of following Panels fabricated out of 2 mm thick CRCA sheet steel fabricated, cubicle type Panel
dust and vermin proof complete with hinged and lockable doors . The Sheet Steel shall under go
minimum eight tank treatment followed by finishing treatment of powder coating with 70 micron
minimum thickness. All the panels shall be floor mounted and dead front construction complete
with interconnections.
a) The panels shall be FRONT operated, with cable entry from the top. Earth bus shall be part of
the panel.) (All MCB to be "C" Curve)
b) The following provisions shall be required to be made in the Distribution Panel as detailed below:
S.No Description UOM QTY RATES AMOUNT
i) All live accessible parts shall be shrouded with 1mm thick polycarbonate/3 mm thick FRP sheet
and all equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable
sleeves according to the colour code. SMC shrouds and busbar supports shall be used. All MCCB
door handle shall be interlocked and lockable in OFF position.
ii) Galvanised hardware with zinc passivation shall be used in fabrication of Switchboards.
iii) Suitable Aluminium earth bus to be provided throughout the length of Switchboards.
iv) All indication lamps / illuminated push buttons shall be LED type.
v) Coil of all motor starters shall be fed from 440 V / 230 V Control Transformer.
vi) 2A SP MCBs shall be used as backup protections.
vii) All MCCBs shall be variable plug setting type with thermal magnetic up to & including 400 A
rating and with microprocessor based releases above 400 A rating, line load reversibility, Ics =
100% Icu,& rotary handle.
viii) All control& power wiring shall be broughtout upto the cable alley in the terminal blocks.
ix) An approval shall be taken for each panel before manufacturing.
x) Provision of one 6/16 amp socket & compartment lighting for each vertical section of main panel.
xi) Illuminated push button on Starter Panels of Pumps.
aa) Interlocking / Auto start command terminals for Starter panels. All Ventilation & pressurisation
fans shall be interlocked with Fire Alarm Panel as per given logic.
ab) All breaking Capacity for MCCB to be Ics=100%Icu.
ac) All MCB to be C Curve
COMMON AREA PANEL
IP Rating : IP 42
1 No. 100 A 35 KA, 4P MCCB of motor duty (Adjustable Magnetic release upto 250A MCCB OR
Micro-Processor based release above 250A MCCB). MCCB shall have 1NO + 1NC auxiliary contacts
+ a trip contact.
Incomer Metering & Indication:
S.No Description UOM QTY RATES AMOUNT
415V / √3 / 110V/ √3 PT's, Cast Resin type, 3 Phase for metering & indications, suitable rated 6A,
TP MPCB of the fault withstand capacity as of the panel on the primary side of PT & suitable rated
6A, TP MCB on the secondary side of PT. This metering PT shall be of Class-1 accuracy.
R,Y,B phase indication lamps (110V) LED Type
ON' & Trip indication lamps (110V) LED Type
Cast resin metering CT's for each phase of class-1 accuracy & of suitable burden & ratio
1 No. Digital VAF + PF Meter (110V) (With RS 485 Port)
100 A, TPN Aluminium Bus bars of electrolytic grade with heat shrinkable sleeve 35 KA.
1 Nos. 100/70 A 35 KA, 4P, MCCB's, motor duty for Lift Panel of Tower.
2 No. 100/32 A 35 KA, 4P, MCCB's, Common Area DB at Tower.
Vendor to ensure selection of MCCB & MCB through cascading effect to mitigate the
prospective fault circuit current.
Common Area Panel as Described Above. Nos 1 125000 125000
Meter Board Panel
Design, manufacture, supply,including supervision during installation, testing and commissioning
of following Panels fabricated out of 2 mm thick CRCA sheet steel fabricated, cubicle type Panel
dust and vermin proof complete with hinged and lockable doors . The Sheet Steel shall under go
minimum eight tank treatment followed by finishing treatment of powder coating with 70 micron
minimum thickness. All the panels shall be floor mounted and dead front construction complete
with interconnections.
a) The panels shall be FRONT operated, with cable entry from the top. Earth bus shall be part of
the panel.) (All MCB to be "C" Curve)
S.No Description UOM QTY RATES AMOUNT
b) The following provisions shall be required to be made in the Distribution Panel as detailed below:
i) All live accessible parts shall be shrouded with 1mm thick polycarbonate/3 mm thick FRP sheet
and all equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable
sleeves according to the colour code. SMC shrouds and busbar supports shall be used. All MCCB
door handle shall be interlocked and lockable in OFF position.
ii) Galvanised hardware with zinc passivation shall be used in fabrication of Switchboards.
iii) Suitable Aluminium earth bus to be provided throughout the length of Switchboards.
iv) All indication lamps / illuminated push buttons shall be LED type.
v) Coil of all motor starters shall be fed from 440 V / 230 V Control Transformer.
vi) 2A SP MCBs shall be used as backup protections.
vii) All MCCBs shall be variable plug setting type with thermal magnetic up to & including 400 A
rating and with microprocessor based releases above 400 A rating, line load reversibility, Ics =
100% Icu,& rotary handle.
viii) All control& power wiring shall be broughtout upto the cable alley in the terminal blocks.
ix) An approval shall be taken for each panel before manufacturing.
x) Provision of one 6/16 amp socket & compartment lighting for each vertical section of main panel.
xi) Illuminated push button on Starter Panels of Pumps.
aa) Interlocking / Auto start command terminals for Starter panels. All Ventilation & pressurisation
fans shall be interlocked with Fire Alarm Panel as per given logic.
ab) All breaking Capacity for MCCB to be Ics=100%Icu.
ac) All MCB to be C Curve
Meter Board (4 Meters):
Incoming Cable connection link work & Bus Bars:
4 Pole 100 Amp 25 KA Aluminium link work & bus bars with heat shrinkable sleeves.
LED type R,Y,B Phase Indication lamps with suitable rating CTs.
4 Nos.40 A, 4P, MCB's
S.No Description UOM QTY RATES AMOUNT
4 Nos. Dual source KWH meter, Class-1 accuracy, (Direct reading type without CT's) 0-40A, 3
Phase, 4 Wire with auto cut-off, With pre-paid facility with room unit and complete with internal
HR FRLS PVC Insulated unsheathed flexible copper conductor wiring of adequate size and input &
output wiring terminal blocks as required.
Meter Board (4 Meters) as described above. Nos 6 85000 510000
MAIN & SUB MAIN CABLES
1.0 Supply of following sizes of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC
sheathed armoured cable conforming to relevant IS (Cable shall be purchased only after approval of cable
schedule by architect / consultant)
1.1 3.5 core, 300 sq.mm. Meter 1446
1.3 3.5 core, 185 sq.mm. Meter 936
2.0 Supply and making end termination with brass single compression glands and aluminium lugs following
sizes of XLPE insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade of the
following sizes as required.
S.No Description UOM QTY RATES AMOUNT
Supplying, installing by suspension on ceiling/along the wall, testing and commissioning of following
capacity Sandwich Type Bus Duct (Outdoor Type) for use on 3 phase 4 wire 415 V, 50Hz A.C. supply with
metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm
thick steel sheet duly powder coated in convenient sections complete with 4 Nos. aluminium bus bars
having current density of 130 A/sq. cm at nominal current rating, necessary joints, elbow joints & expansion
joints and bends, fire barrier at each floor, provision of tapping at every meter, adopter box and copper
flexible for joints, continuous earthing with 2 Nos. aluminium strip of suitable size (one on each side)
including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing
system etc. as required
400 Amp Meter 17,562
2.0 END FEED UNIT-
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, Installation, Testing & Commissioning of
following End Feed Unit housing fabricated out of 14G CRCA powder coated (as approved) sheet steel for
the Rising Mains fitted with following MCCB. The End Feed Unit should complete with solid aluminium
links of rated capacity of MCCB to Rising Mains. The End Feed Unit should be complete with suitable size
of glands plate for incoming cables. All MCCB shall have Ics value of 50 KA. Each end feed unit shall have
a set of 3 nos. phase LED Type indicating lights with control fuses.
2.1 250 A, Isc = 50 kA for 1 second Set 1 85,600 85600
2.3 400 A, Isc = 50 kA for 1 second Set 1,15,600
3.0 TAP OFF UNIT-
S.No Description UOM QTY RATES AMOUNT
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, Installation, Testing & Commissioning of
cubical type tap off unit box fabricated out of 2.0 mm thick CRCA sheet, dust and vermin proof, with hinged
detachable doors and painted front, comprising LED type indication lamps with toggle switches and 4 pole
MCCB terminated directly with tap off box with Bus Bar links on the incoming side and suitable for cable
connection on the outgoing side including making connections, interconnections, earthing complete as
required. All MCCB shall have Ics value of 36 KA and Thermal Magnetc release for over current & short
3.1 Tap Off Box with 160 Amp FP MCCB. 21,560 172480
4 Supply & fixing of end capTap Set 1 8,560 8560
SUPPLY & FIXING OF LIGHT FIXTURES & FANS INTERNAL LIGHTING-
1.0 Supply, Installation, Testing & Commissioning of 1x22 Watt LED Light Fixture surface mounted as per
technical specification. (Philips Make - Cat No BN021C LED20S PSU CDL GR) or equivalent fixture as per Nos 80 1035.85 82868
2.0 Supply, Installation, Testing & Commissioning of 10 W Surface Mounted LED down light Philips make cat
no - DN097B LED10S-6500 PSU WH) or equivalent fixture as per tender make. Nos 120 2192.28 263074
3.0 Supply, Installation, Testing & Commissioning of 15 W Recess Mounted LED down light Philips make cat
no - DN194B LED15S-6500 PSU WH) or equivalent fixture as per tender make. Nos 80 2978.25 238260
4.0 Supply, Installation, Testing & Commissioning of 1x10 Watt LED Light Fixture surface mounted as per
technical specification. (Philips Make - Cat No BN021C LED10S PSU CDL GR) or equivalent fixture as per Nos 60 749.65 44979
5.0 Supply, Installation, Testing & Commissioning of Light Fixture surface mounted. (Philips make cat no-
WT140 LED6S NW PSU S2 PC or equivalent.) Nos 40 1189.85 47594
6.0 Supply, Installation, Testing & Commissioning of GARRNET 12W LED BULB suitable for batten holder.
(Wipro Make or equivalent.) Nos 54 1407.77 76020
7.0 Supply, Installation, Testing & Commissioning of Bracket Light Fixture surface mounted. (Philips make cat
no- 30762 Delight or equivalent.) Nos 45 1598.08 71914
S.No Description UOM QTY RATES AMOUNT
8.0 Supply of following sizes of heavy duty exhaust fan for single phase 230 volt, 50HZ AC supply complete
with motor, blades, frame, bracket, louver/ shutter etc as required. (HavellS Make, Cat No - Ventil Air-DX
or equivalent.)
8.1 250 mm Exhaust Fan Nos 40 2811.18 112447
9.0 Supply of following sizes of ceiling fan complete with double ball bearing, motor, blades, downrod, canopy,
capacitor etc. suitable for operation on 230 volt, 50 Hz, A.C. supply complete as required. (Havells Make,
Cat No-ES-50 Premium 5 or equivalent.)
TOTAL OF ELECTRICAL CARRIED TO SUMMARY 69,50,448
BOQ Fire fighting
Grand Total 23,99,614
Name of Work : Construction of WRPC firefighting works.
Sub Head : Suppy, Installation, Testing & commissioning of fire fighting system.
The rate of each item of work for Fire Detection and Alarm System shall also include the following :
(a) All materials, fixing materials, accessories, appliances, tools and equipment.
(b) Approved cover plates for inspection, junction and outlet boxes.
(c) 1.6 mm thick outlet boxes and junction boxes.
(d) All fixing accessories such as clips, nails, screws etc.
(e) Providing and fixing approved saddles, hooks and grouting the same as required, in the case of all exposed conduit
(f) Providing ,fixing and embedding conduits of suitable dia and accessories in wall, floors etc. during construction
and / or cutting chases and making good as necessary in the case of all concealed conduit work.
(g) Testing and commissioning of each device, circuit as per the requirements of NFPA 72, TAC, local authorities and to
be witnessed by the Construction Manager / Architect / Consultant / Client’s Site representatives and or fire
protection consultant.
S. No. Description of items Unit Qty. Amount
Supplying, installation, Testing and commissionig of electric driven
terrace pump suitable for automatic operation and consisting of
following : complete in all respect as required.
A) Horizontal type, multistage,centrifugal, split casing pump of cast
Iron body & bronze impeller with stainless steel shaft, mechanical
and flow of 900 LPM at 45 M head confirming to IS: 1520.
B) Suitable HP SQ cage induction motor ,TEFC type suitable for
opeartion on 415V , 3 phase 50HZ. AC with IP55 class of protection
for enclosure, horizontal foot mounted type with class -'F'
insulation, confirming to IS: 325.
C) M.S fabricated common base plate , coupling, coupling guard ,
foundation bolts etc. as required.
D) suitable cement concrete foundation duly plastered with anti
vibration pads.
Digitally signed by AMIT JAIN
S. No. Description of items Unit Qty. Amount
Fabrication, Supplying, installation, Testing and commissionig of
electrical control panel of cubical construction , floor mounted
type , fabricated out of 2mm. Thick CRCA sheet,
compartmentalised with hinged lockable door , dust and vermin
proof, powder coated of approved shade after 7 tank treatment
process, cable alley , inter-connection , having switchgears and
accessories mounting and internal wiring , earthing terminals ,
numbering etc. complete in all respect suitable for operation on
415V, 3 phase , 50HZ , AC supply with enclosure protection class IP
(A) COMMON PANEL IN FIRE PUMP HOUSE
(a)63 AMPS . FP MCCB.
(b)Voltmeter (0-500Volts) with selector switch.
(c)Ameter (0-250 Amps) with selector switch and CT's Etc.
(d)Set of three phase indicating Lamp.
(e)Set of Al.bus bar 315amps.
Supplying of XLPE insulated , PVC sheathed alluminium conductor
3 1.1 KV grade armoured Cable of following sizes on surface / in
existing cable tray suitably clamped as required.
4 LT CABLE LAYING AND TERMINATIONs
(a) Laying and fixing of one number PVC insulated and PVC
sheathed / XLPE power cable of 1.1 KV grade of following size on
wall surface as required.
4.1 Upto 35 sq. mm (clamped with 1mm thick saddle) m 25 25.00 625.00 signed by AMIT JAIN
S. No. Description of items Unit Qty. Amount
Supplying and making end termination with brass compression
5 gland & Al. lugs for following sizes of PVC sheathed / XLPE Al.
conductor cables of 1.1 KV grade as required.
Earthing with G.I earth plate 600mm X 600mm X 6mm thick
6 including accessories and providing masonry enclosure with cover set 2 4,327.00 8,654.00
plate having locking arrangement and watering pipe of 2.7M long
etc. with charcoal / coke and salt as required.
Earthing with G.I earth pipe 4.5Meter long, 40mm dia including
7 accessories, and providing masonry enclosure with cover plate each 2 3,672.00 7,344.00
having locking arrangement and watering pipe etc. (with charcoal/
coke and salt as required).
providing and fixing 6 SWG dia GI wire on surface on in recess for
loop earthing complete as required.
Fabrication and Installation of following sizes of perforated MS
cable tray including horizontal and vertical bends, reducers, tees,
9 cross-members and other accesseries as required duly suspended
from the ceiling with MS Suspenders and including painting with
post office red synthetic paint as required.
Digitally signed by AMIT JAIN
S. No. Description of items Unit Qty. Amount
Providing, laying, testing & commissioning of 'C' class heavy duty
MS Pipe conforming to IS 3589 and 1239 including fittings like
10 elbows, tees, flanges, tapers, nuts bolts, gaskets etc., fixing the
pipe on the wall/ceiling with suitable clamps and painting with two
or more coats of synthetic enamel paint of required shade
complete as required.
Supplying and fixing single headed internal hydrant valve with
11 instantaneous Gun metal couplings of 63 mm dia with cast iron Nos. 12 6,698.00 80,376.00
wheel ISI marked conforming to IS 5290 (Type -A) with blank
Gunmetal cap and chain as required.
Supplying, fixing, testing and commissioning of butterfly valve PN
12 1.6, with Bronze/Gunmetal seat duly ISI marked complete with
Nuts, Bolts, washers, gaskets, conforming to IS 13095, of following
sizes as required.
Providing installation, testing & commissioning of dual plate non-
13 return valve of following sizes confirming to IS:5312 complete with
rubber gasket, GI bolts,nuts,washers etc. as required.
Digitally signed by AMIT JAIN
S. No. Description of items Unit Qty. Amount
Providing Installation, testing & commissioning of stainless steel
14 strainer fabricated out of 1.6 mm. thick stainless steel sheet with 3
mm. dia holes with stainless steel flange.
Providing installation, testing & commissioning of gun metal valves
of following sizes as required.
Supplying and fixing 63 mm. dia, 15 mtr. Long RRL hose pipe with
16 63 mm. dia male and female Gun metal couplings duly binded with Nos 24 3,590.00 86,160.00
GI wire, rivets etc. conforming to IS:636 (type-A) as required.
Supplying and fixing First -Aid Hose Reel with MS construction
spray painted in post office Red , conforming to IS: 884 with upto
date amendments, cpmplete with the following as required.
(a) 20/30/40 m. long 20 mm(nominal internal) dia water hose
17 thermoplastic (textile reinforced ) type -2 as per IS:12585. Nos 12 5,371.00 64,452.00
(b) 20 mm(nominal internal) dia gun metal globe valve & nozzle.
(c)Drum and brackets for fixing the equipmets on wall .
(d) connections from riser with 40 mm dia stop valve (gun metal)
Digitally signed by AMIT JAIN
S. No. Description of items Unit Qty. Amount
Supplying and fixing of hose cabinet size 800 mm X 600 mm X 200
mm made of 2 mm thick MS sheet with 6 mm thick glazed glass
doors i/c necessary locking arrangement suitable to accommodate
18 external hydrant with butterfly valve ,2 nos. 15mtr. long Hose Nos 2 6,260.00 12,520.00
pipe, 1No. branch pipe ,mounted on wall OR raised brick platform
& duly painted with post office red externally and white internally
with synthetic enamel paint complete in all respect , for hydrant at
terrace, as required.
Supplying and fixing 63 mm. dia, Gun metal branch pipe with 20
19 mm (nominal internal diameter) size gun metal nozzle conforming Nos 24 2,512.00 60,288.00
to IS 903 , suitable for instantaneous connection to interconnect
hose pipe coupling as required.
Supplying and fixing air vessel made of 600 mm dia ,8 mm thick
MS sheet, 2100 mm. in height with air release valve on top and
20 flanged connection to riser, drain arrangement with 25 mm dia No 2 28,457.00 56,914.00
Gun metal wheel valve ,with required accessories , pressure gauge
and painting with synthetic enamel paint of approved shade as
Providing & fixing Pressure Switch in the M.S,Pipe Line including
connection etc. as required
Supplying and fixing of hose cabinet size 900 mm X 600 mm X 500
mm made of 2 mm thick MS sheet with 6 mm thick glazed glass
doors i/c necessary locking arrangement suitable to accommodate
22 external hydrant with butterfly valve ,2 nos. 15mtr. long Hose Nos 12 6,144.00 73,728.00
pipe, 1No. branch pipe ,mounted on wall OR raised brick platform
& duly painted with post office red externally and white internally
with synthetic enamel paint complete in all respect , for external
hydrant, as required.
Digitally signed by AMIT JAIN
S. No. Description of items Unit Qty. Amount
Providing & fixing angle iron (40 mm x 40 mm x 5 mm) door frame
and M.S sheet (2 mm.thick) cum glass shutter of size 2.1 mtr. x 1.2
mtr. (N.S.) with 25 mm. x 25 mm. x 3 mm. angle frame all around
23 & stiffened in between i/c hinges, handle, locking arrangement, Nos 12 6,144.00 73,728.00
painting with approved synthetic enamel paint i/c sign writing on
glass at internal hydrant including providing & fixing M.S.Sheet 2
mm.thick on remaining portion above door to close opening i/c
painting etc.as required.
Providing and fixing dial type pressure gauge with isolation
24 cock and pipe at hydrant station & sprinkler line. Each 12 680.00 8,160.00
a) Diameter 100 mm calibration 0-8 Kg.
Providing and fixing CO2 type fire extinguishers with steel cylinder
25 with a discharge valve and conforming to IS:15683. Extinguishers Each 12 6,569.00 78,828.00
shall be painted with red enamel paint and fixed to wall with
brackets capacity 4.5 Kg.
Providing and fixing ABC powder type fire extinguisher suitable for
inverted operation and fabricated from 1.6 mm M.S. sheet
internally protected with anticorrosive treatment and hydraulically
26 tested to a pressure of 25 Kg/Sqcm. Extinguishers externally Each 12 3,365.00 40,380.00
painted with red enamel and fixed to wall with brackets complete
with internal charge and spanner (Conforming to IS:13849
capaicity 6 Kg.).
Providing and laying rubber mats suitable for 1.1. KV as per IS
Grand Total 12,66,250.00
Grand Total 12,66,250.00
Digitally signed by AMIT JAIN
SCHEDULE OF WORK
Name of Work : Construction of WRPC firefighting works.
Sub Head : Suppy, Installation, Testing & commissioning of fire fighting system.
The rate of each item of work for Fire Detection and Alarm System shall also include the following :
(a) All materials, fixing materials, accessories, appliances, tools and equipment.
(b) Approved cover plates for inspection, junction and outlet boxes.
(c) 1.6 mm thick outlet boxes and junction boxes.
(d) All fixing accessories such as clips, nails, screws etc.
(e) Providing and fixing approved saddles, hooks and grouting the same as required, in the case of all exposed conduit
Providing ,fixing and embedding conduits of suitable dia and accessories in wall, floors etc. during construction
and / or cutting chases and making good as necessary in the case of all concealed conduit work.
(g) Testing and commissioning of each device, circuit as per the requirements of NFPA 72, TAC, local authorities and to
be witnessed by the Construction Manager / Architect / Consultant / Client’s Site representatives and or fire
protection consultant.
Description of items Rate Unit
S. No. Unit Qty. Amount
Supplying, installation, Testing and commissionig of electric driven
terrace pump suitable for automatic operation and consisting of
following : complete in all respect as required.
A) Horizontal type, multistage,centrifugal, split casing pump of cast
Iron body & bronze impeller with stainless steel shaft, mechanical
and flow of 900 LPM at 45 M head confirming to IS: 1520.
B) Suitable HP SQ cage induction motor ,TEFC type suitable for
opeartion on 415V , 3 phase 50HZ. AC with IP55 class of protection
for enclosure, horizontal foot mounted type with class -'F'
insulation, confirming to IS: 325.
C) M.S fabricated common base plate , coupling, coupling guard ,
foundation bolts etc. as required.
D) suitable cement concrete foundation duly plastered with anti
vibration pads.
Digitally signed by AMIT JAIN
Description of items Rate Unit
S. No. Unit Qty. Amount
Fabrication, Supplying, installation, Testing and commissionig of
electrical control panel of cubical construction , floor mounted
type , fabricated out of 2mm. Thick CRCA sheet,
compartmentalised with hinged lockable door , dust and vermin
proof, powder coated of approved shade after 7 tank treatment
process, cable alley , inter-connection , having switchgears and
accessories mounting and internal wiring , earthing terminals ,
numbering etc. complete in all respect suitable for operation on
415V, 3 phase , 50HZ , AC supply with enclosure protection class IP
42 as required.
(A) COMMON PANEL IN FIRE PUMP HOUSE
(a)63 AMPS . FP MCCB.
(b)Voltmeter (0-500Volts) with selector switch.
(c)Ameter (0-250 Amps) with selector switch and CT's Etc.
(d)Set of three phase indicating Lamp.
(e)Set of Al.bus bar 315amps.
Supplying of XLPE insulated , PVC sheathed alluminium conductor
3 1.1 KV grade armoured Cable of following sizes on surface / in
existing cable tray suitably clamped as required.
4 LT CABLE LAYING AND TERMINATIONs
(a) Laying and fixing of one number PVC insulated and PVC
sheathed / XLPE power cable of 1.1 KV grade of following size on
wall surface as required.
4.1 Upto 35 sq. mm (clamped with 1mm thick saddle) m 25 25.00 625.00
Digitally signed by AMIT JAIN
Description of items Rate Unit
S. No. Unit Qty. Amount
Supplying and making end termination with brass compression
5 gland & Al. lugs for following sizes of PVC sheathed / XLPE Al.
conductor cables of 1.1 KV grade as required.
Earthing with G.I earth plate 600mm X 600mm X 6mm thick
6 including accessories and providing masonry enclosure with cover set 2 4,327.00 8,654.00
plate having locking arrangement and watering pipe of 2.7M long
etc. with charcoal / coke and salt as required.
Earthing with G.I earth pipe 4.5Meter long, 40mm dia including
7 accessories, and providing masonry enclosure with cover plate each 2 3,672.00 7,344.00
having locking arrangement and watering pipe etc. (with charcoal/
coke and salt as required).
providing and fixing 6 SWG dia GI wire on surface on in recess for
loop earthing complete as required.
Fabrication and Installation of following sizes of perforated MS
cable tray including horizontal and vertical bends, reducers, tees,
9 cross-members and other accesseries as required duly suspended
from the ceiling with MS Suspenders and including painting with
post office red synthetic paint as required.
Digitally signed by AMIT JAIN
Description of items Rate Unit
S. No. Unit Qty. Amount
Providing, laying, testing & commissioning of 'C' class heavy duty
MS Pipe conforming to IS 3589 and 1239 including fittings like
10 elbows, tees, flanges, tapers, nuts bolts, gaskets etc., fixing the
pipe on the wall/ceiling with suitable clamps and painting with two
or more coats of synthetic enamel paint of required shade
complete as required.
Supplying and fixing single headed internal hydrant valve with
11 instantaneous Gun metal couplings of 63 mm dia with cast iron Nos. 12 6,698.00 80,376.00
wheel ISI marked conforming to IS 5290 (Type -A) with blank
Gunmetal cap and chain as required.
Supplying, fixing, testing and commissioning of butterfly valve PN
12 1.6, with Bronze/Gunmetal seat duly ISI marked complete with
Nuts, Bolts, washers, gaskets, conforming to IS 13095, of following
sizes as required.
Providing installation, testing & commissioning of dual plate non-
13 return valve of following sizes confirming to IS:5312 complete with
rubber gasket, GI bolts,nuts,washers etc. as required.
Digitally signed by AMIT JAIN
Description of items Rate Unit
S. No. Unit Qty. Amount
Providing Installation, testing & commissioning of stainless steel
14 strainer fabricated out of 1.6 mm. thick stainless steel sheet with 3
mm. dia holes with stainless steel flange.
Providing installation, testing & commissioning of gun metal valves
of following sizes as required.
Supplying and fixing 63 mm. dia, 15 mtr. Long RRL hose pipe with
16 63 mm. dia male and female Gun metal couplings duly binded with Nos 12 3,590.00 43,080.00
GI wire, rivets etc. conforming to IS:636 (type-A) as required.
Supplying and fixing First -Aid Hose Reel with MS construction
spray painted in post office Red , conforming to IS: 884 with upto
date amendments, cpmplete with the following as required.
(a) 20/30/40 m. long 20 mm(nominal internal) dia water hose
17 thermoplastic (textile reinforced ) type -2 as per IS:12585. Nos 8 5,371.00 42,968.00
(b) 20 mm(nominal internal) dia gun metal globe valve & nozzle.
(c)Drum and brackets for fixing the equipmets on wall .
(d) connections from riser with 40 mm dia stop valve (gun metal)
Digitally signed by AMIT JAIN
Description of items Rate Unit
S. No. Unit Qty. Amount
Supplying and fixing of hose cabinet size 800 mm X 600 mm X 200
mm made of 2 mm thick MS sheet with 6 mm thick glazed glass
doors i/c necessary locking arrangement suitable to accommodate
18 external hydrant with butterfly valve ,2 nos. 15mtr. long Hose Nos 2 6,260.00 12,520.00
pipe, 1No. branch pipe ,mounted on wall OR raised brick platform
& duly painted with post office red externally and white internally
with synthetic enamel paint complete in all respect , for hydrant at
terrace, as required.
Supplying and fixing 63 mm. dia, Gun metal branch pipe with 20
19 mm (nominal internal diameter) size gun metal nozzle conforming Nos 6 2,512.00 15,072.00
to IS 903 , suitable for instantaneous connection to interconnect
hose pipe coupling as required.
Supplying and fixing air vessel made of 600 mm dia ,8 mm thick
MS sheet, 2100 mm. in height with air release valve on top and
20 flanged connection to riser, drain arrangement with 25 mm dia No 1 28,457.00 28,457.00
Gun metal wheel valve ,with required accessories , pressure gauge
and painting with synthetic enamel paint of approved shade as
Providing & fixing Pressure Switch in the M.S,Pipe Line including
connection etc. as required
Supplying and fixing of hose cabinet size 900 mm X 600 mm X 500
mm made of 2 mm thick MS sheet with 6 mm thick glazed glass
doors i/c necessary locking arrangement suitable to accommodate
22 external hydrant with butterfly valve ,2 nos. 15mtr. long Hose Nos 8 6,144.00 49,152.00
pipe, 1No. branch pipe ,mounted on wall OR raised brick platform
& duly painted with post office red externally and white internally
with synthetic enamel paint complete in all respect , for external
hydrant, as required.
Digitally signed by AMIT JAIN
Description of items Rate Unit
S. No. Unit Qty. Amount
Providing & fixing angle iron (40 mm x 40 mm x 5 mm) door frame
and M.S sheet (2 mm.thick) cum glass shutter of size 2.1 mtr. x 1.2
mtr. (N.S.) with 25 mm. x 25 mm. x 3 mm. angle frame all around
23 & stiffened in between i/c hinges, handle, locking arrangement, Nos 1 6,144.00 6,144.00
painting with approved synthetic enamel paint i/c sign writing on
glass at internal hydrant including providing & fixing M.S.Sheet 2
mm.thick on remaining portion above door to close opening i/c
painting etc.as required.
Providing and fixing dial type pressure gauge with isolation
24 cock and pipe at hydrant station & sprinkler line. Each 6 680.00 4,080.00
a) Diameter 100 mm calibration 0-8 Kg.
Providing and fixing CO2 type fire extinguishers with steel cylinder
25 with a discharge valve and conforming to IS:15683. Extinguishers Each 6 6,569.00 39,414.00
shall be painted with red enamel paint and fixed to wall with
brackets capacity 4.5 Kg.
Providing and fixing ABC powder type fire extinguisher suitable for
inverted operation and fabricated from 1.6 mm M.S. sheet
internally protected with anticorrosive treatment and hydraulically
26 tested to a pressure of 25 Kg/Sqcm. Extinguishers externally Each 6 3,365.00 20,190.00
painted with red enamel and fixed to wall with brackets complete
with internal charge and spanner (Conforming to IS:13849
capaicity 6 Kg.).
Providing and laying rubber mats suitable for 1.1. KV as per IS
Grand Total 7,67,321.00
Grand Total 7,67,321.00
Digitally signed by AMIT JAIN
BILL OF QUANTITIES FOR ELECTRICAL WORKS FOR WRPC
SUMMERY OF COST
S. No. DESCRIPTION OF ITEM
DSR NON DSR TOTAL (DSR & NON DSR)
BILL OF QUANTITIES FOR ELECTRICAL WORKS FOR WRPC
S. No. DESCRIPTION OF ITEM UNIT QTY RATE AMOUNT
VI LIFT SYSTEM-
1.0 PASSENGER LIFT-(WITH MACHINE ROOM)-
Design, manufacturing, testing at works, supply and
delivery, receiving, unloading, storing, inspection, handling,
assembling, installing in correct assigned position, effecting
proper connections, testing and commissioning of following
capacity passenger-lifts, having speed of 1.5 MPS 5 stops
and 5 openings and total travel of 20.00 meters approx.
with VVVF drive, full collective duplex/Simplex control on
415 V, 50 cycles, 3 phase power complete in accordance
with specifications and drawings as required with Car, Car
Door & Hoistway Door in stainless steel hairline
finish,CCTV provisioning, inclusive of built in ARD and as
per specification.
TOTAL OF LIFT SYSTEM CARRIED OVER TO
S. No. Description of item Amount
1 EXTERNAL WATER SUPPLY & GARDEN HYDRANT SYSTEM 20,84,468.90
2 EXTERNAL SEWERAGE, DRAINAGE AND RAIN WATER HARVESTING 64,07,153.37
EXTERNAL ELECTRICIFICATION, TRANSFORMERS, DG SETS, LIGHTS
4 UNDERGROUND TANK & PUMPS 37,42,718.41
5 SOLID WASTE DECOMPOST MACHINE 2,38,000.00
GRAND TOTAL 2,20,43,352.80
GRAND TOTAL 2,20,43,352.80
GRAND TOTAL 2,60,11,156.30
GRAND TOTAL 2,60,11,156.30
BILL OF QUANTITIES
EXTERNAL WATER SUPPLY & GARDEN HYDRANT SYSTEM
S. No. DSR-2023/ Description of item Unit Rate Amount
Providing and laying cPVC pipes of the following dia conforming to
IS:1239 and ISI marked (medium grade) in trenches complete with
cPVC fittings & flanges including excavating in trenches in any type
of soil, including back filling, spreading of surplus earth in layers not
exceeding 20 cm in depth including consolidating each deposited
layer by ramming, watering within the site as per direction of
PD/Architect and anti corrosive treatment (painting pipes with two
coats of Bitumastic paint, wrapping polythene tape and applying a
final coat of bitumastic paint) covering pipes 10 cm all around with
sand of grading zone V or coarser grade, testing and dis-infection
with water containing bleaching powder complete all as specified
and as directed by Project Director/Architect.
Providing and fixing cPVC ball Valve of approved quality complete
all as specified of following sizes.
Providing and fixing C.I. double acting air valve of approved quality
3 18.59 with bolts, nuts, rubber insertions etc and testing complete including
the cost of tail pieces all as specified for following sizes.
Providing and fixing C.I. sluice valve conforming to IS: 14846-2000
of PN 1.6 class 1 and I.S.I. marked with cap complete including
4 18.31 fixing with rubber packing 3 mm thick, nuts and bolts etc. and
testing complete including the cost of tail pieces all as specified for
following sizes.
EXTERNAL WATER SUPPLY & GARDEN HYDRANT SYSTEM
S. No. DSR-2023/ Description of item Unit Rate Amount
Providing and laying 1:2:4 cement concrete (1 cement: 2
coarse sand: 4 graded stone aggregate 20mm nominal size) for
thrust block including necessary excavation, centering, shuttering
and plastering etc. complete.
Material and labour for construction of masonry chamber 60x60x75
cm inside with bricks of class designation 7.5 in cement mortar 1:4
(1 cement : 4 coarse sand) for sluice valve with C.I. surface box
100mm dia at top,160 mm dia at bottom and 180 mm deep (inside)
with hinged cover fixed in R.C.C. slab 1:2:4 mix ( 1 cement : 2
coarse sand : 4 graded stone aggregate 20 mm nominal size)
6 18.36.1 necessary excavation in any type of soil, foundation concrete 1:5:10 Nos 10.00 10,354.95 1,03,549.50
( 1 cement : 5 coarse sand: 10 graded stone aggregate 40 mm
nominal size) and inside plastering with cement mortar 1:3 ( 1
cement : 3 coarse sand ) 12 mm thick finished with a floating coat of
neat cement complete as per standard design including disposal of
excavated earth within the plot as per direction of PD/Architect and
all as specified and shown on drawings.
Material and labour for construction of masonry chamber 30x30x50
cm inside with bricks of class designation 7.5 in cement mortar 1:4 (
1 cement : 4 coarse sand) for stop cock with C.I. surface box
100x100x75 mm (inside) with locking arrangements and RCC top
slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size ) necessary excavation in any type
of soil, foundation concrete 1:5:10 ( 1 cement : 5 coarse sand : 10
graded stone aggregate 40 mm nominal size ) and inside plastering
with cement mortar 1:3 ( 1 cement : 3 coarse sand ) 12 mm thick
finished with a floating coat of neat cement complete as per
standard design including disposal of excavated earth within
AWHO plot as per direction of PD/Architect.
Structural steel work welded in built up sections, trusses and framed
work including cutting, hoisting, fixing in position and applying a
priming coat of approved steel primer and two or more coats of
enamel paint all complete.
EXTERNAL WATER SUPPLY & GARDEN HYDRANT SYSTEM
S. No. DSR-2023/ Description of item Unit Rate Amount
Providing & fixing of Garden hydrant outlet consisting 20mm dia.
Ball valve, Bib cock (Brass) for connecting rubber hose, pipes &
fittings incl. brick masonry chambers complete all as specified &
shown on drawings.
Providing & fixing BUTTERFLY VALVE (MANUAL) with C I body
10 SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for
chilled water/hot water circulation as specified.
Providing & fixing NON - RETURN VALVE with duel plate of C I
ELECT. DSR body SS plates vulcanized NBR seal flanged end & PN 16 pressure
2022 / 16.7.3 rating for chilled / hot water circulation including insulation as
Providing and fixing in position 25 mm diameter mosquito proof
coupling of approved municipal design.
Material & labour for making connection of Water line with existing
municipal water supply line including cutting of road/ footpath &
making good the same complete all as specified and as per
direction of PD/Architect.
Providing and fixing C.I. dirt box strainer with bulk type water meter
duly approved by municipal authority along with pressure gauge,
14 18.61 nuts, bolts, rubber insertions etc. complete conforming to IS : 2373
Providing, laying, Jointing, Testing and commissioning of UPVC
pressure pipes of 10Kg/Sqcm pressure rating class 5 (IS : 4985-
2000) including fittings, tees, bends, clamps, coupling and adaptors
supports, and jointing with solvent joint, testing and necessary earth
15 NSI work in excavation, backfilling, disposal of surplus earth with a lead
upto 50m complete, compaction and consolidation Including laying
cement concrete 1:2:4 alround UPVC pipe including bed concrete
and thrust blocks at bends as per standard design (For garden
EXTERNAL WATER SUPPLY & GARDEN HYDRANT SYSTEM
S. No. DSR-2023/ Description of item Unit Rate Amount
15.4 NSI 50 OD mm Each 388.38 -
Providing and fixing enclosed type water meter (bulk type)
conforming to IS : 2373 and tested by Municipal Board complete
with bolts, nuts, rebber insertions etc. (The tail pieces if required will
be paid seperately) :
Providing and fixing of cast iron wafer type butterfly valves (PN 10)
complete with 2 nos. matching flanges ( table-E) , bolts, nuts,
washers 3 mm thick insertion neoprene gasket conforming to IS
Supply, installation, testing and commissioning of PGP Gear Driven
Sprinkler with popup height of 4" & radius 4-5.8 m check valve for
drainage prevention seal and all other features including Swing
joints and all assessories as per specification complete .
Supply, installation, testing and commissioning of PGP Shrub
21.00 NSI Sprinkler with radius 4-5.8 m with ASTM pipe riser and all Each 10.00 2,500.00 25,000.00
accessories as per specification.
22.00 Providing and fixing brass automatic air vent at the top of each
TOTAL OF WATER SUPPLY & GARDEN HYDRANT CARRIED TO SUMMARY 20,84,468.90
BILL OF QUANTITIES
EXTERNAL SEWERAGE, DRAINAGE AND RAIN WATER HARVESTING
S. No. DSR-2023/ Description of item Unit Qty Rate Amount
EXTERNAL SEWERAGE SYSTEM
Excavating trenches of required width for pipes, cables, etc including
excavation for sockets, and dressing of sides, ramming of bottoms, depth
upto 1.5 m, including getting out the excavated soil, and then returning the
1 2.10 soil as required, in layers not exceeding 20 cm in depth, including
consolidating each deposited layer by ramming, watering, etc. and
disposing of surplus excavated soil as directed, within a lead of 50 m :
1.1 2.10.1 All kinds of soil
1.1.1 2.10.1.2 Pipes, cables etc. exceeding 80 mm dia. But not exceeding 300 mm dia Metre 460.00 415.50 1,91,130.74
Extra for excavating trenches for pipes, cables, etc. in ordinary/hard
2 2.14 rock exceeding 1.5 m in depth but not exceeding 3 m. (Rate is over
corresponding basic item for depth upto 1.5 metre)
2.1 2.14.1 Ordinary rock:
2.1.1 2.14.1.1 Pipes, cables etc. exceeding 80 mm dia. But not exceeding 300 mm dia Metre 46.00 861.16 39,613.54
Providing, laying and jointing glazed stoneware pipes class SP-1
3 19.1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement
: 1 fine sand) including testing of joints etc. complete :
Providing, laying and jointing non pressure NP2 class (light duty) RCC
pipes with collars jointed with stiff mixture of cement mortar in the
proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc.
complete for following sizes and all as specified
EXTERNAL SEWERAGE, DRAINAGE AND RAIN WATER HARVESTING
S. No. DSR-2023/ Description of item Unit Qty Rate Amount
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand: 10
graded stone aggregate of 40mm nominal size) all around SWG pipes
including bed concrete 15 cm thick as per standard design complete all as
Providing and laying in position cement concrete of grade 1:5:10 (1
6 4.1 cement: 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
including the cost of centering and shuttering all as specified
6.1 4.1.10 All works upto plinth level Cum 2.70 6,518.60 17,600.22
Material and labour for constructing brick masonry manhole with bricks of
class designation 7.5 in cement mortar 1:4 (1 cement: 4 coarse sand) RCC
top slab with 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone
aggregate 20mm nominal size) including nominal reinforcement,
necessary excavation in any type of soil and back filling in 20 cm thick
layers, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand: 8 graded
7 19.7 stone aggregate 40mm nominal size) inside plastering 12mm thick with
cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of
neat cement and making channels in cement concrete 1:2:4 (1 cement: 2
coarse sand: 4 graded stone aggregate 20mm nominal size) finished with
floating coat of neat cement including 12mm thick external plaster with
cement mortar 1:6 (1 cement: 6 fine sand) complete as per standard
design shown in drawing.
Inside size 90x80cm and 45cm deep including SFRC cover with frame
7.1 19.7.1 (medium duty) 450x600mm internal dimensions & conforming to IS: 12592. Each 10.00 12,770.55 1,27,705.50
Total weight of cover and frame shall not be less than 140 kg
8 19.8.1.1 Extra for depth for manhole size 90x80cm beyond 45cm. Each 10.00 8,825.40 88,254.00
EXTERNAL SEWERAGE, DRAINAGE AND RAIN WATER HARVESTING
S. No. DSR-2023/ Description of item Unit Qty Rate Amount
Material and labour for constructing brick masonry circular type manhole
1.22 m dia internal at bottom and 0.56 m dia at top with 7.5 class
designation bricks in cement mortar 1:4 ( 1 cement : 4 coarse sand ) inside
cement plaster 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse
sand) finished with a floating coat of neat cement and foundation concrete
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm
nominal size )and making necessary channel in cement concrete 1:2:4 (1
9 19.11.1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size
)finished with a floating coat of neat cement including 12 mm thick external
plaster with cement mortar 1:6 ( 1 cement : 6 fine sand ) and P.V.C.
encased on 12mm dia steel bar Footrest including cost of necessary
excavation in any type of soil and backfilling in 20 cm thick layers,
dewatering if any, shuttering and shoring and disposal of surplus
excavated soil within the AWHO plot complete as per specifications,
drawings and as per standard design.
1.68 m deep with S.F.R.C. cover and frame ( heavy duty HD 20 grade
designation) 560 mm internal dia. Conforming to IS 12592, total weight of
cover and frame to be not less than 182 kg fixed in cement concrete 1:2:4 Each 12.00 24,702.75 2,96,433.00
9.1 19.11.1.1 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal
size ) including centering shuttering all complete.
(Foot rests shall be paid separately under item hereinafter).
Extra depth for circular manhole 0.610 m internal dia (at bottom) excluding
PVC encased on 12mm dia steel bar footrests: -
EXTERNAL SEWERAGE, DRAINAGE AND RAIN WATER HARVESTING
S. No. DSR-2023/ Description of item Unit Qty Rate Amount
Providing orange colour safety foot rest of minimum 6 mm thick plastic
encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS :
1786, having minimum cross section as 23 mmx25 mm and over all
minimum length 263 mm and width as 165 mm with minimum 112 mm
space between protruded legs having 2 mm tread on top surface by
ribbing or chequering besides necessary and adequate anchoring
projections on tail length on 138 mm as per standard drawing and suitable
to with stand the bend test and chemical resistance test as per
specifications and having manufacture's permanent identification mark to
be visible even after fixing, including fixing in manholes with 30x20x15 cm
cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone
aggregate 20 mm nominal size) complete as per standard design.
Providing and fixing square mouth SW gully trap grade ‘A’ complete CI
grating brick masonry chamber with bricks of class designation 75 and
12 19.4 water tight CI cover with frame of 300 x 300 mm size (inside) the weight of
cover to be not less than 13.00 kg and frame to be not less than 5 kg as
per standard design.
12.1 19.4.3.1 180x150 mm size P type with FPS bricks Each 76.00 2,802.15 2,12,963.40
EXTERNAL DRAINAGE SYSTEM
Earthwork in excavation in any type of soil in all of foundation trenches
including dressing of sides, ramming of bottoms. Lifts upto 1.5 m including
getting out the excavated soil and then returning the soil as required in
layers not exceeding 20 cm in depth including consolidating each
13 2.8 deposited layer by ramming, watering etc, bailing out / pumping out water if Cum 958.00 260.30 2,49,367.40
any and disposing of surplus excavated soil including carriage/disposal of
earth/material by mechanical transport including loading/unloading/
stacking etc as directed by Project Director within or outside the AWHO
Providing and laying non-pressure NP2 class (light duty) RCC pipes with
collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1
cement: 2 fine sand) including testing of joints etc. complete. (for storm
EXTERNAL SEWERAGE, DRAINAGE AND RAIN WATER HARVESTING
S. No. DSR-2023/ Description of item Unit Qty Rate Amount
14.1 19.6.2 150 mm dia RCC pipe Metre 0 556.45 -
14.2 19.6.3 250 mm dia RCC pipe Metre 0 899.80 -
14.5 19.6.7 600 mm dia RCC pipe Metre 0 2,243.40 -
Constructing brick masonry road gully chamber 50x45x60 cm with bricks of
class designation 75 in cement mortar 1:5 (1 cement : 5 fine sand)
including 500 x 450 mm (heavy duty) precast RCC horizontal grating with
frame complete as per standard design.
With common burnt clay F.P.S. (non modular) bricks of
class designation 7.5
Providing and laying in position cement concrete of specified grade
excluding the cost of centering and shuttering by 1:4:8 (1 cement: 4 coarse
sand: 8 graded stone aggregate 40 mm nominal size) - for PCC bed of
Brick work with F.P.S. bricks of class designation 7.5 in foundation and
plinth in cement mortar 1:6 (1 cement: 6 coarse sand).
Providing and laying in position cement concrete of specified grade
excluding the cost of centering and shuttering (for filling of drain haunches)
by 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
Providing and laying Plain cement concrete coping 40mm thick with
19 4.1.4 cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone Sqm 150.00 7,780.30 11,67,045.00
aggregate 12.5mm nominal size).
Material and labour for 12 mm thick cement plaster of mix 1:6 (1 cement: 6
Providing and fixing factory made precast RCC perforated drain covers,
having concrete of strength not less than M-25, of size 1000x450x50 mm,
reinforced with 8 mm dia four nos. longitudinal & 9 nos. cross sectional
T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to
125 mm c/c, including providing edge binding with M.S. flats of size 50 mm
x 1.6 mm complete, all as per direction of PD/Architect.
EXTERNAL SEWERAGE, DRAINAGE AND RAIN WATER HARVESTING
S. No. DSR-2023/ Description of item Unit Qty Rate Amount
Reinforced cement concrete work in RCC culvert slab with 1:1.5:3 (1
22 4.1.2 cement: 1.5 coarse sand and 3 graded stone aggregate of 20 mm nominal Cum 12.00 8,340.85 1,00,090.20
size) excluding centering and shuttering and reinforcement.
Steel reinforcement Thermo Mechanically Treated (TMT) bars for R.C.C.
23 5.22.6 work including straightening, cutting, bending, placing in position and Kg 266.00 107.85 28,688.10
binding all complete upto plinth level.
Centering and shuttering including strutting, propping etc and removal of
form for suspended floors roofs etc for culvert slab
Construction of Rain Water Recharge Pit of size as shown on drawings
from the invert level of drain inlet pipe including earth work in excavation
and drilling having 300mm dia bore size in all kind of strata, back filling
with available excavated earth with necessary compaction and disposal of
surplus earth, inside/outside AWHO plot as directed by the Project
Director, 200 mm thick PCC 1:4:8 (1 Cement:4 Coarse Sand: 8 Graded
Stone Aggregate 40 mm nominal size), brick work in cement mortar 1:4 (1
cement: 4 coarse sand), Internal plaster 12mm thick in cement mortar 1:4
(1 cement: 4 coarse sand), PVC coated safety steel foot rest of 12mm dia
MS bars grouted rigidly in cement concrete 1:2:4 of size 300x300x150mm
@ 300mm gap from centre of centre. Providing & fixing hard drawn steel
wire fabric 75x25mm mesh including priming coat and wall face uPVC rain
water of 110 dia pipe including jointing with seal ring leaving 10mm gap for
thermal expansion and RCC top cover slab of M-25 design mix as per
drawing including centering & shuttering. Providing and filling filter media,
150mm dia UPVC pipe medium well casing pipe conforming to IS: 12818
including fittings & accessories. Supplying, filling, spreading & leveling
layer of coarse sand of size ranges 1.5 to 2mm, layer of pea gravel of size
range 4.6mm to 4.8mm and stone boulders of size range 5cm to 20cm in
the required thickness, placing two numbers of 600x450mm (internal
dimensions) SFRC manhole covers (H.D) with frame conforming to
IS:12592 and 200mm dia SW pipe grade ‘A’ with stiff mixture of CM in the
proportion 1:1 (1 cement : 1 fine sand) including testing of joints complete
all as specified & shown in the drawings.
EXTERNAL SEWERAGE, DRAINAGE AND RAIN WATER HARVESTING
S. No. DSR-2023/ Description of item Unit Qty Rate Amount
Construction of Desilting chamber of size as shown on drawings from the
invert level of drain inlet pipe including earth work in excavation, back
filling available excavated earth with necessary compaction and disposal
of surplus earth inside/outside AWHO plot as directed by the Project
Director, 200 mm thick PCC 1:4:8 ( 1 Cement:4 Coarse Sand: 8 graded
Stone Aggregate 40mm nominal size), brick work in cement mortar 1:4 (1
cement: 4 coarse sand), PVC coated safety steel foot rest of 12mm dia MS
bars grouted rigidly in cement concrete 1:2:4 of size 300x150x150mm @
300mm gap from centre of centre, Internal plaster 12mm thick in cement
mortar 1:4 (1 cement: 4 coarse sand) and RCC top cover slab in design
mix M-25 as per drawing including centering & shuttering. Supplying,
filling, spreading & leveling layer of coarse sand of size ranges 1.5 to
2mm, placing two numbers 600x450mm SFRC manhole cover (H.D) with
frame conforming to IS:12592 200mm dia SW pipe grade ‘A’ with stiff
mixture of CM in the proportion 1:1 (1 cement : 1 fine sand) including
testing of joints complete all as specified & shown in the drawing.
Rerouting, making connection of Drainage lines with existing manhole in
all respects, including breaking into and making good the walls, floors with
cement concrete 1:2:4 mix (1cement: 2 coarse sand: 4 graded stone
aggregate 20mm nominal size) cement plastered on both sides with
27 MR cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat Job 1.00 2,00,000.00 2,00,000.00
of neat cement and making necessary channels for the drain etc. complete
for pipes 300 to 450 mm dia.
Note: No extra cost shall be paid for works required for rerouting and
connection of existing lines.
Rerouting, making connection of Sewerage lines with existing manhole in
all respects, including breaking into and making good the walls, floors with
cement concrete 1:2:4 mix (1cement: 2 coarse sand: 4 graded stone
aggregate 20mm nominal size) cement plastered on both sides with
28 MR cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat Job 1.00 3,00,000.00 3,00,000.00
of neat cement and making necessary channels for the drain etc. complete
for pipes 450 to 600 mm dia.
EXTERNAL SEWERAGE, DRAINAGE AND RAIN WATER HARVESTING
S. No. DSR-2023/ Description of item Unit Qty Rate Amount
Note: No extra cost shall be paid for works required for rerouting and
connection of existing lines.
TOTAL OF EXTERNAL SEWERAGE, DRAINAGE AND RAIN WATER HARVESTING
CARRIED TO SUMMARY
BILL OF QUANTITIES
EXTERNAL ELECTRICIFICATION, TRANSFORMERS, DG SETS, LIGHTS AND PANELS
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
S.H.-I SUB STATION WORK
1.0 TWO POLE STRUCTURE:
Supply, erection and commissioning of 2 pole structure for terminating 11
KV O.H. supply from State Electricity Boards as per specifications. The 2-
pole structure shall comprise of:
MS tubular swaged pole 11 mtrs high (410 SP 24 as per latest IS), in
cement concrete foundation 1:3:6 (1 cement : 3 coarse sand : 6 graded
aggregate 40mm nominal size) including excavation and refilling etc. as
required. The rate shall be inclusive of painting with 2 coats of aluminium
paint (on red oxide). The portion of pole under the ground shall be
provided with 2 coats of bituminous paint - 2 Nos.
Steel sections, channels angles, flats, clamps, GI nuts, bolts and required
hardware etc of different sizes for cross arms, bracings, supports etc. for
pole GOD etc. including anticlimbing barbed wires (conforming to latest
IS) having 4 points barbs spaced 75 ±12mm apart. All steel structure shall
be given 2 coats of red oxide primer and 2 finishing coats of aluminium
paint as required as per drawings and direction of Engineer-in-Charge. -
Supply,installation, testing and commissioning of 11 KV class
disc/pin/support insulators complete with clamps and fixing hard wares
etc. complete as required as per drawings and direction of Engineer-in-
Supply,installation, testing and commissioning of 11 KV station class
thyrite type lightning arrestors complete with mounting arrangement (on
all phases) - 3 Nos.
EXTERNAL ELECTRICIFICATION, TRANSFORMERS, DG SETS, LIGHTS AND PANELS
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
Supply,installation, testing and commissioning of drop out - lock out
(DOLO) fuse, gang operating device (Air Break Switch) with pad locking
arrangement (operating rod to be supported properly), complete with
operating handle and locking arrangement-1 Set
Supply,installation, testing and commissioning of GI stay set complete
with 20mm dia 1.8 M long stay rod with 450 x 450 x 7.5 mm anchor plate
with thimbles, stay clamps, 7/4.00 mm dia GI stay wire, turn buckle
(20mm x 600mm) strain insulator bow tightner in cement concrete 1:3:6
foundation as excavation and refilling - 2 Set
5.1 Two pole structure as described above. SET 1.0 1,80,000 180000
Note: The excavation and other civil works related to two pole structure
are to be included in cost.
The liasioning fee of KESCO is not included in the above costing.
2.1 11KV H.T. METERING PANEL (INDOOR TYPE):
Supply, Receiving, Unloading, Storing, Shifting, Installation, Testing &
Commissioning of indoor type floor mounted, dust, damp and vermin proof,
cubicle HT. Metering Panel made out of 14 gauge CRCA sheet steel complete
with 5Amp electronic trivector meter, C.T.'s of 200/5Amp, 0.5 Class, 10VA
Burden, and P.T's of 11KV/ /3, 110V/ /3, 100 VA conforming to relevant IS
Standards and complete as required. H.T. Metering cubicle along with C.T.'s,
P.T.'s and trivector meter shall be got tested and approved from local electricity
supply authority. The GA drawing shall be got approved by ELECTRICITY
BOARD authorities before fabrication.The HT panel shall be suitable for
software integration with BMS. One for office building and one for residential
building billing perposus.
2.2 11KV, ONE BREAKER PANEL- (INDOOR TYPE)
EXTERNAL ELECTRICIFICATION, TRANSFORMERS, DG SETS, LIGHTS AND PANELS
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
Supply, Receiving, Unloading, Shifting, Installation Testing & Commissioning of
11 KV VCB Single Breaker Panel Board as Icomming / Outgoing shall be metal
clad floor mounting complete as per specification and as described.
630 A VCB Breaker of (350 MVA) 18.4 KA ruputuring capacity at 11 KV rated,
totally enclosed, air insulated metal clad housing, floor mounting, horizontal
isolation, vermin proof, fully interlocked horizontal drawout type having isolation
features and control devices complete with the following.
Manually and motor operated, spring charged (release closing mechanism) trip
free type, triple pole truck mounted draw out, VCB, incorporating mechanical as
well as electrical ON/OFF indication. Spring charge/discharge mechanical
indication"OFF" push buttons for emergency trip (shrouded) test/service position
limit switches with 6 NO/6NC breaker auxilliary contacts in service position, 24
Volts DC shunt trip coil and strip heater to prevent moisture absorption.
11 KV HT VCB Breaker Panel Board (Indoor Type)
Supply, Receiving, Unloading, Shifting, Installation Testing & Commissioning of
11 KV Three Breaker Vacuum Circuit Breaker Panel Board as 1 Incomming & 1
Outgoing shall be metal clad floor mounting complete as per specification and
630 A Vacuum circuit breaker of (350 MVA) 18.4 KA ruputuring capacity at 11
KV rated, totally enclosed,air insulated metal clad housing, floor mounting,
horizontal isolation, vermin proof, fully interlocked horizontal drawout type having
isolation features and control devices complete with the following.
EXTERNAL ELECTRICIFICATION, TRANSFORMERS, DG SETS, LIGHTS AND PANELS
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
Manually and motor operated, spring charged (release closing mechanism) trip
free type,triple pole truck mounted draw out, vacuum circuit breaker,
incorporating mechanical as well as electrical ON/OFF indication. Spring
charge/discharge mechanical indication"OFF" push buttons for emergency trip
(shrouded) test/service position limit switches with 6 NO/6 NC breaker auxilliary
contacts in service position, 24 Volts DC shunt trip coil and strip heater to
prevent moisture absorption.
INCOMING PANEL - 1 NO.
1 No 630 A Vacuum circuit breaker of (350 MVA) 18.4 KA ruputuring capacity
at 11 KV rated, totally enclosed,air insulated metal clad housing, floor mounting,
horizontal isolation,vermin proof,fully interlocked horizontal drawout type having
isolation features and control devices complete with the following:
3 No. Single Phase double core current transformer 200/5 Amp epoxy cast
insulated class of insulation E.
Core 1-15VA burden class 1.0 for metering.
Core 2-15VA burden class 5P10 for protection.
P.T's of 11KV/1.732, 110V/1.732, 100VA with suitable rating H.T. & L.T. fuse
conforming to relevant IS Standards and complete as required.
One no. numerical microprocessor based three phase over current (IDMT
element) (2 O/C+1E/F) with earth fault relay with instantaneous elements.
1 No. Anti Pumping device.
1 No. Circuit breaker control switch for electrical (T/N/C).
1 No. limit switch for test & service position.
1 No. Voltmeter (0-12KV) with selector switch. (96mm square)
1 No. Ammeter (0-80Amp) with selector switch. (96mm square).
1 No. electronic type digital energy analyser having 30 days memory and
parameters of KW, KWH, Power factor, frequency etc. Suitable for BMS
compatible with all accessories.
1 Set of following indicating lamps.
Red, Yellow & Blue for phase indication.
EXTERNAL ELECTRICIFICATION, TRANSFORMERS, DG SETS, LIGHTS AND PANELS
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
Amber for Trip indication.
Red `ON' Green `OFF'
Spring charge indication.
Auto trip indication.
1 No. hooter with hooter acceptance and reset push button.
1 No. master trip relay. ( Electromechanical Type )
1 No.Trip ckt supervision relay. (Electromechanical Type )
600A color coded heat shrinkable sleeved TP Copper busbar of 350 MVA fault
1 Set of fuses, ferrules, wiring etc. as required.
1 Set of Power Pack 220 Volt A.C. / 24 Volt D.C. complete as required.
1 No. control Transformer of 1KVA for giving supply to indication lamps etc
having 11 KV/415-230V AC rating epoxy cast resin dry type Transformer. The
connection for control transformer shall be taken from the cable side before the
circuit breaker tapping.
Note: All spare contacts of breaker or any other equipment inside the breaker
shall be wired upto the outgoing terminal strip with appropriate ferrules / coding.
The terminal strip rating shall be suitable for connecting two wires of 2.5sqmm
subjected to providing minimum size strip suitable for 4/6sqmm.
Note: All spare contacts of breaker or any other equipment inside the breaker
shall be wired upto the outgoing terminal strip with appropriate ferrules / coding.
The terminal strip rating shall be suitable for connecting two wires of 2.5sqmm
subjected to providing minimum size strip suitable for 4/6sqmm.
H.T. Panel describe as above Set 1 250000 250000
3.0 TRANSFORMERS
3.1 TRANSFORMER 225 KVA (11 KV / 0.415 KV):
EXTERNAL ELECTRICIFICATION, TRANSFORMERS, DG SETS, LIGHTS AND PANELS
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
Design, manufacture, supply, installation, testing and commissioning of 11 KV
/0.433 KV, 3 phase, 50 Hz delta/star-11 connected, door type, transformer (rating
as specified below), oil immersed ONAN cooled, complete with all fittings such
as oil conservator, silica gel breather, thermometer, explosion vent with on Load
Tap changing (OLTC) arrangement on HV side with Tapping for variations of
high voltage from (+) 5% to (-) 15% in steps of 2.5% each with integrated
microprocessor based RTCC Panel, bi-directional roller, diagrams & rating plate,
Oil temperature indicator, & Winding temperature indicator, Buchholz relay,
weather proof Marshalling Box, lifting lugs, first filling of oil, weather proof
H.T/L.T cable box etc. complete as per specification. All relays, contacts & CT
terminals to be wired upto marshalling box. Transformer shall be as per latest
IS:1180, 1 Star.
225 KVA rating Set 1 360000 360000
4.0 11 KV H.T. CABLE:
Supplying of 11 KV grade aluminium conductor, cross linked polyethylene
(XLPE) insulated individual core screened, flat steel/strip armoured PVC
sheathed cable complete as required.
4.1 3C x 240 Sqmm, 11 KV XLPE Meter 200 1176 235292
5.0 DIESEL GENERATING SET:
5.0 DIESEL GENERATING SET: 250 KVA x 2 NOS
EXTERNAL ELECTRICIFICATION, TRANSFORMERS, DG SETS, LIGHTS AND PANELS
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, Storing,
Installation, Testing and Commissioning of Radiator Cooled DG sets of following
capacity (rating in kVA) compact packaged silent type, with Outdoor type
Acoustic Enclosure to reduce the noise level as per requirements of central
pollution control board, 415Volts, 3 phase, 50 Hz AC alternator coupled to diesel
engine with Electronic Governer Suitable for Auto Load Sharing and Auto
Synchronizing System complete with all accessories, standard specifications tool
kits, service manual, self starting device, fly wheel, coupling with guard, V velt,
radiator, instrument panel (starting switch with key, Water Temperature indicator
gauge, Lub OIl Pressure gauge, Lube oil temperature gauge, Battery Charging
Ammeter, indicating lamp, hour counter etc., residential silencer, common bed
plate, anti vibration isolation pads, extended cable termination box, grouting
bolts, first charge of engine oil, gear oil, high speed diesel oil, 24 volt
maintenance free chargeable battery set with Trickle/Boost Battery charger,
interface card for BMS connectivity complete as required of rating 415 Volts, 3
phase, 50 Hz. AC alternator coupled to Diesel Engine complete with all
accessories. NOC from concerned goverment authority for installation and
operation of D.G. set shall be taken by contractor.
5.1 250 KVA D.G. Set with suitable capacity of day oil fuel Tank with PCC 3.3 or
equivalent as per CPWD specification & Latest CPCB regulation. Set 2.00 1618875 3237750
5.2 EXHAUST PIPE & CHIMNEY
Supply, installation, testing and commissioning of following sizes MS exhaust
piping heavy duty conforming to IS: 3589 complete with all accessories such as
bends, flanges, stainless steel flexible bellows etc as complete as required.
5.2.1 250 mm dia (5.2mm thick) Metre 25 3580 89503
EXTERNAL ELECTRICIFICATION, TRANSFORMERS, DG SETS, LIGHTS AND PANELS
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
5.2.2 Providing & Fixing of Insulation of Exhaust Pipe with rockwool of min 75 mm
thickness min. 64 Kg/m3 density and 26 SWG Aluminium cladding Sq.m 200 1752 350460
5.2.3 Supply, Fabrication, & erection of MS structure for supporting of DG emission,
exhaust piping with RCC foundation and in cable trench for cable support etc.
complete in all respect. Kg 2000 218 436600
6.0 SAFETY EQUIPMENT
6.1 First aid box as approved by St.John Ambulance Brigade /Indian Red Cross
society conforming to IS : 2217 - 1963. Nos. 3 1883 5650
6.2 Shock treatment chart duly mounted on a wooden frame with glass on, as
required in 2 languages (Hindi & English). Nos. 3 1256 3767
6.3 Rubber mat 1000 mm. Wide to withstand 1.1 KV, 2.0 mm thick dielectric
strength as per latest IS 15652-2006. Meter 3 2260 6779
6.4 Rubber mat 1000 mm. Wide to withstand 11 KV, 2.5 mm thick dielectric
strength as per latest IS 15652-2006. Meter 3 2887 8662
S.H.-II DISTRIBUTION PANEL & DISTRIBUTION BOARDS-
1.4 INVERTER PANEL BASEMENT - 1, 2 & 3
1 No. 63 Amp FP Moulded Case Circuit Breaker.
1 No.0 to 500 Volt digital voltmeter with selector switch.
1 No.0 to 100 Amp digital Ammeter with selector switch and CT's.
1Set of phase indicating lamps with HRC fuses.
1Set of ON/OFF indicating lamps with HRC fuses.
EXTERNAL ELECTRICIFICATION, TRANSFORMERS, DG SETS, LIGHTS AND PANELS
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
150Amp TPN aluminium busbar with coloured heat shrinkable sleeve.
02 Nos. 63 Amp DP Miniature Circuit Breaker.
Panel described as above Set 3 48500 145500
1.5 MCCB BOX WITH MCCB (INCOMMING/OUTGOING)
INCOMING/OUTGOING
1 No. 63 Amp FP Moulded Case Circuit Breaker.
Panel described as above Set 4 15620 62480
2.0 DG Synchronizing Cum Changeover Panel (2x250)-01
EXTERNAL ELECTRICIFICATION, TRANSFORMERS, DG SETS, LIGHTS AND PANELS
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
Supply, Erection, Testing & Commissioning of Main DG Control panel with D.G.
Synchronizing controller & Micro PLC, this will be floor mounted, free standing,
compartmentalized, indoor duty, dust proof, vermin proof, front operated,
electrical panel fabricated, painted and manufactured exactly as per
specifications laid in this document and will be complete with the main and
auxiliary bus bars, interconnection, earth terminals, earth bus and will be
powdered coated finished. All the busbar joint shall be protected by clip on type
sleeve. The DG control panel shall use all draw out 3 position withdrawn type
breakers suitable for 415 V AC, 3 phase, 50 Hz, 4 wire supply system and will
have fault level of 50 KA or as required as per consultant approval. The panel
will be made as per detailed specifications and drawings forming part of this
document. (Under no case temperature of LT Panel shall be more at any point
of the panel, otherwise necessary exhaust fan shall be have to provided) Bus
bar calculations considering temperature derating, enclosure derating, sleeving
derating must be done and submitted for checking. (The D.G. Set controller
shall be part of D.G. Set).
The DG vendor shall make complete protection curves and discrimination chart
for relay settings and shall adjust all these readings at site. The bus bar size
shall not be less than the ampere sizes mentions after derating. The bidder will
show exact calculations & compare the figure of 0.66 and final calculations will
be adopted for more stringent condition. each incommer shall have surge
protection device. The PCC panel will comprise of the following :
Each incoming / outgoing breaker shall have microprocessor release with
adjustable over current, short circuit & earth fault protection with instantaneous
as mentioned in specification. The Panel will be made as per detailed
specifications & drawings forming part of this document. Fault level of panel shall
EXTERNAL ELECTRICIFICATION, TRANSFORMERS, DG SETS, LIGHTS AND PANELS
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
All the MCCB up to 250 Amp shall have thermal release with adustable overload,
short circuit & earth fault protection and above shall have microprocessor release
with adjustable overload, short circuit & earthfault protection. The panel shall be
manufactured as per BOQ, tech specification and drawing.
One set of Generator control relay for Each D.G. Set with accessories for AMF,
Load Management, Synchronizing and Interlocking through micro PLC. (Make of
relay - Woodword / Dief).
02 Nos 630 A feeder incomer and Each incomer breaker feeder shall have
following: (For 250 KVA DG SET )-
02 NOS incomer 3P 630 amps EDO breaker with 1000 Amp TP neutral
contactor. Each breaker shall have microprocessor based releases for O/C,S/C
& earth fault protection with instantaneous.
3 No. indicating lamps to show the incoming power along with HRC fuses.
1 No. digital ammeter, ammeter selector switch, digital voltmeter, Voltmeter
selector switch.
1 No. Load Manager EM 6400 with RS 485 port
1 no. REF relay
Announciation window to cover LLOP, HWT, OIL Pressure, U/V, O/V, U/F, O/F,
O/C, E/F, REF relay faults shall be provided. 2 nos phase reversal relay shall be
Engine should trip on LLOP, HWT, oil temp, O/V, O/F and breaker should trip on
Initially U/V & U/F will be bye passed till oil pressure is picked up.
Indicating lights for ACB ON / OFF, ACB trip, neutral contactor ON, D.G. on
mains, D.G. fails to start.
Generator start /stop facility through push button from panel, necessary cranking
relay shall be provided.
Suitable battery charger for 24V 360 AH with d.c voltmeter & d.c ammeter. D.C
voltmeter and ammeter will be analouge type.
EXTERNAL ELECTRICIFICATION, TRANSFORMERS, DG SETS, LIGHTS AND PANELS
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
Whenever D.G. stop through PB, load shall be disconnected first.
Incomming Feeder from Main L.T. Panel (Grid Supply): Transformer 1 Nos
1 No.630 Amp FP Electrically operated horizontal drawout type Air Circuit
Breaker microprocessor based releases for O/C,S/C & earth fault protection with
instantaneous. (For Incommer) (25 KA)
1 Nos. 630 Amp FP Electrically operated horizontal drawout type Air Circuit
Breaker as buscoupler with interlocking arrangement with incomers. (25 KA)
1 Sets of indicating lamps for ON & OFF of bus coupler.
800 Amp TPN busbars of aluminium alloy as per SLD.
03 No. 400 Amp FP Moulded Case Circuit Breaker for Resi. Tower 7,8 & 9
02 Nos. 400 Amp FP Moulded Case Circuit Breaker Spare
08 Nos 250 A TP+N Moulded Case Circuit Breaker. For Plumbing
02 Nos 160 A TP+N Moulded Case Circuit Breaker Extranal Light Panel
08 Nos 250 A TP+N Moulded Case Circuit Breaker. Spare
02 Nos 160 A TP+N Moulded Case Circuit Breaker. Spare
2 Nos. 0 to 500 Volt digital voltmeter with Voltmeter Selector Switch & Protective
SP MCB (96mm square) (one for each Incoming Breaker).
2 No. 0 to 1250 Amp digital ammeter (96mm square) with CT's.
2 Sets of phase indicating lights (RYB) with protection fuses (one set for each
incoming breaker).
2 Sets breaker 'ON' & 'OFF' indicating lamp (one set for each incoming breaker).
EXTERNAL ELECTRICIFICATION, TRANSFORMERS, DG SETS, LIGHTS AND PANELS
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
2 Sets trip circuit healthy indicating lamp (one set for each incoming breaker).
2 Sets auto trip indicating lamp (one set for each incoming breaker).
2 Nos. Multifunction Meter (one for each Incoming Breaker).
BATTERY & BATTERY CHARGER
1 No. 24V, 72AH SMF Battery with suitable battery charger for control supply.
D.G. Synchronizing Cum Changeover Panel describe as above Set 1 75000 75000
6.0 EXTERNAL LIGHTING PANEL (OUTDOOR TYPE)-
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, installation,
testing & commissioning of cubicle type totally enclosed free standing type
moisture, dust and vermin proof Floor Distribution Panel made out of 2.0 mm
thick & front cover 1.6 mm thick CRCA sheet complete with following
equipments, including 24 hours clock digital timer , digital ammeter with inbuilt
ammeter selector switch, digital voltmeter with inbuilt voltmeter selector switch,
indicating lamps, CT's, internal wiring with suitable size wires / cable,
interconnection,interlocking arrangment with outdoor street light lux sensor,
painting complete as per specification & drawing.
1 No. 100 Amp FP ( 35 KA Ics) Moulded Case Circuit Breaker.
1 No. 0 to 500 Volt digital voltmeter with inbuilt selector switch.
1 No. 60 Amp digital ammeter with inbuilt selector switch and CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
1 Set 24 Hrs TSQ Timer
1 Set outdoor light level lux sensor
1 Set 63 Amp, 4P Contactor & A/M switch and Push Button.
Interlocking with outdoor type lux sensor
EXTERNAL ELECTRICIFICATION, TRANSFORMERS, DG SETS, LIGHTS AND PANELS
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
150 Amp TPN aluminium busbar.
08 No. 25 Amp DP MCB.
03 No. 40 Amp TPN MCB.
Panel described as above Set 2 187050 374100
7.0 Supply, fixing, testing and commissioning of automatic Linear pneumatic Tube
Detection based Novec 1230 System for Electrical Panels (Linear Pnuematic
Heat Detection Tube Panel Protection System), consisting of the following
Mentioned components-
7.1 10 LB capacity Novec 1230 , DLP Assembly with automatic valve, push in
connector for tube, 10 LB Novec 1230 gas , mounting bracket, End of Line
adopter and low pressure switch for monitoring system activation. No 1 184146 184146
7.2 Linear Pneumatic Heat detection tube with all necessary & supperts Meter 150 3247 487104
7.3 Master Control Unit with Audio Visual Alarm with wiring to make complete
system operational . The control Panel should have provision for integration with
fire Alarm /SCAD/BMS System. No 1 8399 8399
S.H.-II MAIN & SUB MAIN CABLES
1.0 Supply of following sizes of 1.1KV grade multicore aluminium conductor XLPE
insulated and PVC sheathed armoured cable conforming to relevant IS (Cable
shall be purchased only after approval of cable schedule by architect /
1.1 3.5 core, 300 sq.mm. Meter 0 995 0
1.3 3.5 core, 185 sq.mm. Meter 0 644 0
1.4 3.5 core, 120 sq.mm. Meter 0 436 0
EXTERNAL ELECTRICIFICATION, TRANSFORMERS, DG SETS, LIGHTS AND PANELS
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
1.6 3.5 core, 70 sq.mm. Meter 0 281 0
1.8 3.5 core, 35 sq.mm. Meter 0 161 0
1.9 4.0 core, 25 sq.mm. Meter 0 140 0
1.11 4.0 core, 10 sq.mm. Meter 0 93 0
1.13 2.0 core, 10 sq.mm. Meter 0 70 0
2.0 Supply & Laying of following sizes of 1.1KV grade multistranded copper
conductor PVC insulated cable including termination complete as required in
existing cable tray.
2.1 1Cx16 sq.mm PVC Insulated cu wire including termination etc. for UPS neutral
earthing and UPS. Meter 500 65 32500
2.2 1Cx35 sq.mm PVC Insulated cu wire including termination etc. for D.G. neutral
earthing Meter 250 141 35250
S.H-III SUPPLY & FIXING OF LIGHT FIXTURES-
EXTERNAL ELECTRICIFICATION, TRANSFORMERS, DG SETS, LIGHTS AND PANELS
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
1.0 Supply Installation , testing & commissioning of 60 W Solar integral AIO (All-in-
One) streetlight with high pressure die-cast (LM6 Alloy) Aluminium housing,
reliable & robust construction with IP65 & IK08 protection, suitable for OD
50/60mm bracket, having Min 4500 system lumens,suitable for 24hrs (2 Nights)
Autonomy. The luminaire should work on Hybrid
mode with priority for solar, in case solar charging is not available then it should
automatically switch to AC grid supply for reliable operation. Dimming Profile:
From Dusk – First 04 hours full brightness level • Next fixed at 30% Brightness
• Lithium Pherrophosphate Battery capacity min [email protected] or 256Wh &
Battery Temp range -10 to +50℃. Panel capacity min 60Wp, CRI >=70, System
Efficacy >150lm/W, & system wattage should not be more than 30W ± 2%, if
wattages increases then the size of battery & panel shall also be increased in
similar percentage to maintain equal autonomy of the system. The fixture should
have designed for street light application & should have flexible angle of
mounting from 0-15 Degree for divers geographical condition. Life class of LED
System 50000hrs@L70. LED
Make:CREE/NICHIA/LUMILEDS/OSRAM/PHILIPS/BAJAJ. CE
Certified, charger efficiency >90% and standards IEC62109-1, IEC61547,
CISPR15,IEC62093, IEC61347-2-13, EN50530, IEC62384 or equivalent BIS
Standards. The PV module should be made up of crystalline silicon solar cells
"Mono-Crystalline" and must have a certificate of testing conforming to IEC
61215 Edition II / BIS 14286 ,IEC 61730-1,2 IEC60598, Operating temp -10
Degree C to 50 Degree C
EXTERNAL ELECTRICIFICATION, TRANSFORMERS, DG SETS, LIGHTS AND PANELS
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
2.0 SITC of 6mtr long hot dip Galvanized octagonal Pole with top of the pole
70 mm dia (A/F) and bottom of the pole 130 mm dia (A/F) made out of
3mm sheet with MS base plate of size 200mm (NS) x 200mm (NS) x
12mm (NS) on precast RCC foundation complete with suitable size
opening inside the pole with flush weather proof door with locking
facility preferably with LN key having proper arrangement with
Accommodating of 1 Nos. 6 Amp.,10 KA MCB & neutral link 4 way
connector suitable for 16 Sqmm cable complete with electrically safe
including inside cable termination with thimbles i/c wiring from pole box
to fitting with 3x1.5 sq.mm. FRLSH Green PVC insulated copper
conductor wire, earth connection, din channel, earth stud and other
accessories pertaining to this pole But without street light fitting etc as
reqd.including providing & laying in position suitable RCC foundation as Nos
required for 6 Mtrs. octagonal hot dip Galvanized Pole as per
Manufacturers drawing with 1:1.5:3 concrete (1 cement : 1.5 coarse
sand : 3 graded stone aggregate 20 mm nominal size ) including
excavation of all kind of earth such as all type of soil/soft rock or hard
rock etc. as per existing site condition i/c providing, cutting, bending and
placing reinforcement & J type foundation bolts , anchor plate and
templates in position as per manufacturer Standard and Providing PVC
Pipe for Cable Entry and Exits Including Disposal of Surplus Malba / Soft
rock / Hard rock Stone etc. as required.
EXTERNAL ELECTRICIFICATION, TRANSFORMERS, DG SETS, LIGHTS AND PANELS
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
3.0 Supplying and fixing of 1.0 meter Single Arm Bracket with suitable angle
having triangular stiffener of size 100x50x5 mm thick complete with nut
bolts etc at a height of 6.00 Mtrs. complete as required.(for 6 Mtrs pole)
4.0 Supplying and fixing of 1.0 Double Arm Bracket with suitable angle
having triangular stiffener of size 100x50x5 mm thick complete with nut
bolts etc at a height of 6.00 Mtrs. complete as required.(for 6 Mtrs pole)
5.0 Supplying, Installation, Testing and Commissioning of (28) Watt LED
post top lantern Having Lighting Colour Cool White Rated life 50000 hrs
With all Necessary Required Fixtures for Mounting etc as required.
6.0 Supplying, Installation, Testing and Commissioning of (11) Watt LED
Bollard garden light complete with required nos. lamps, control gears
etc. complete as required as per the standard catalogue item.
7.0 Supplying, Installation, Testing and Commissioning of (9) Watt LED of
spike light for tree complete with required nos. lamps, control gears etc.
complete as required as per the standard catalogue item.
8 MISCELLANEOUS ITEMS
EXTERNAL ELECTRICIFICATION, TRANSFORMERS, DG SETS, LIGHTS AND PANELS
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
Supply, laying, jointing, testing and commissioning of ISI marked (IS : 14930,
part 2) H.D.P.E. (DWC) Double wall Corrugated pipe for cable laying having
corrugation on outer wall and plain smooth surface at inner side including
8.1 transportation upto the site, jointing, providing and fixing all fittings i.e. sockets,
couplers, reducers, end caps etc including excavation in all kind of soil upto 1
meter depth of suitable width with back filling of soil into trenches to complete
the works in all respects.
Supplying & Laying of Following sizes 1100 volt grade Insulated PVC
sheathed Copper conductor armoured cables as per specification in
existing laid in ground including cost of digging upto required depth, 150
8.2 mm sand all around the cable, brick protection and back filling, clamped
to wall with suitable clamps including saddles fixing bolts, connection
testing and commissioning as Required.
2x10 + 1 x6 sqmm (for Guard Room/HT Room DB'S)
Supplying & Laying of Following sizes 1100 volt grade insulated PVC
sheathed Copper conductor armoured cables as per specification in
existing trenches/pipes, cable trays, ducts, clamped to wall with suitable
clamps including, saddles fixing bolts, connecting testing and
8.3 commissioning as Required.
9 G.I. EARTHING
EXTERNAL ELECTRICIFICATION, TRANSFORMERS, DG SETS, LIGHTS AND PANELS
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
SITC of Advance Chemical gel earthing system of Dual Pipe Technology (G.I.)
Chemrode of 3 mtrs long 46-50mm dia of outer pipe with 23- 25mm dia of inner
pipe with hot dip galvanizing filled with highly conducting metallic compounds
with the permanent sealings at both the ends with the lead terminal of
32x10mm size at the top with hole size of 12mm . The length of the electrode
shall be 3000mm excluding the lead terminal and the length of the lead
terminal at the top shall be 100mm. The electrode shall be duly tested and
certified by CPRI (Central Power Research Institute), Govt of India for a RMS
short-circuit current withstanding capacity of 33 KA and a peak short-circuit
withstanding capacity of 72 KA. To ensure the moisture content and electrical
conductivity, 50 Kgs of Reslow - resistance lowering grounding minerals shall be
used as a backfill compound. The compound shall be of low resistance & high
conductivity in nature with carbon as a major content which dramatically Set 22 6000 132000
lowers ground resistance system in difficult soil situations. Test certificate from
BIS (Bureau of Indian Standards), Govt of India accredited laboratory confirming
the contents. As per IEEE 80-2000 (clause 14.5d) standard, Test certificate from
NABL, BIS, DGS&D, MOEF, DGQA accredited laboratory confirming the ohmic
value of less than 0.12 ohm-mtr. The moisture retaining capacity (pH Value) of
the chemical back fill compound shall be between 7 to 7.2. The chemical backfill
compound shall be tested & certiifed by any BIS (Bureau of Indian Standards),
Govt of India accredited laboratory and also the testing laboratory shall be an
ISO 9001 & ISO 14001 certified. The earthing system manufacturer shall be an
ISO 9001 & ISO 14001 certified to ensure the quality.
EXTERNAL ELECTRICIFICATION, TRANSFORMERS, DG SETS, LIGHTS AND PANELS
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
SITC of Advance Chemical gel earthing system of Dual Pipe Technology (CU.)
Chemrode of 3 mtrs long 46-50mm dia of outer pipe with 23- 25mm dia of inner
pipe with hot dip galvanizing filled with highly conducting metallic compounds
with the permanent sealings at both the ends with the lead terminal of
32x10mm size at the top with hole size of 12mm . The length of the electrode
shall be 3000mm excluding the lead terminal and the length of the lead
terminal at the top shall be 100mm. The electrode shall be duly tested and
certified by CPRI (Central Power Research Institute), Govt of India for a RMS
short-circuit current withstanding capacity of 33 KA and a peak short-circuit
withstanding capacity of 72 KA. To ensure the moisture content and electrical
conductivity, 50 Kgs of Reslow - resistance lowering grounding minerals shall be
used as a backfill compound. The compound shall be of low resistance & high
conductivity in nature with carbon as a major content which dramatically Set 8 25000 200000
lowers ground resistance system in difficult soil situations. Test certificate from
BIS (Bureau of Indian Standards), Govt of India accredited laboratory confirming
the contents. As per IEEE 80-2000 (clause 14.5d) standard, Test certificate from
NABL, BIS, DGS&D, MOEF, DGQA accredited laboratory confirming the ohmic
value of less than 0.12 ohm-mtr. The moisture retaining capacity (pH Value) of
the chemical back fill compound shall be between 7 to 7.2. The chemical backfill
compound shall be tested & certiifed by any BIS (Bureau of Indian Standards),
Govt of India accredited laboratory and also the testing laboratory shall be an
ISO 9001 & ISO 14001 certified. The earthing system manufacturer shall be an
ISO 9001 & ISO 14001 certified to ensure the quality.
EXTERNAL ELECTRICIFICATION, TRANSFORMERS, DG SETS, LIGHTS AND PANELS
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
SITC of Heavy Duty Weather Proof Environment Friendly Polyplastic Earth
pit Chamber With Cover of Autolocking Facility with the following dimensions -
254mm dia (top), 330mm dia (bottom) and 260mm height. 4 knock-out Set 30 3000 90,000
openings are provided for the easy interconnection of earth strips between the
9.3 earth pits to form a grid.
Providing & fixing 6 swg wire in surface or in recess for loop earthing as required
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing
along with existing surface/ recessed conduit/ submain wiring/ cable as Meter 1400 15 21000
10 Light Management System
SITC of 4 Channel - mutlti operation relay, with each 16A channel with
high-inrush current capacity of 80A/20 ms. With detachable KNX
programmable upper module which can be fixed post the installation of
the lower relay unit. 4 different channel functions can be selected: -
Switching, ON/OFF Delay, Pulse function, Staircase light timer with
switch-off pre-warning. Possible integration of the channels into a Nos 2 25900 51800
maximum of 8 scenes. Adjustable response to bus failure and restoration
of the bus/mains power. Logical functions.
EXTERNAL ELECTRICIFICATION, TRANSFORMERS, DG SETS, LIGHTS AND PANELS
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
S. No. DESCRIPTION OF ITEM UNIT QTY RATE TOTAL AMOUNT
SITC of BUS Power Supply, 640mA Power Supply. For supplying power
to other Bus devices with bus voltage. One non-choked and one choked
output each. The non-choked output can be used for the supply of
another line or for function devices (smart sensor etc.) which require an
auxiliary voltage. Nominal voltage can be subdivided to outputs (choked
or nonchoked) as desired. With reset switch for bus lines. With short
circuit protection. With overvoltage protection.
SITC Of bus sytem to IP Router/Interface/Gateway, Connecting IP with
TP Bus system Supporting routing and tunneling functions Indicated
operation and filtering statuses by LEDs Connecting Bus IP/other devices
by a standard RJ45 connector directly and also via Ethernet networks A
rail-mounted device for installation in distribution boards on 35 mm DIN
rails Integrated bootloader function for remote firmware updates via IP /
Ethernet Temporary deactivation of filtering by a single button press Nos 1 42500 42500
(Eases commissioning because of short-time access to other lines.) No
need for an additional power supply
10.4 SITC of KNX Wire 4 core 2*2*0.8 sqmm Mtrs 600 180 108000
10.5 SITC of Automation DB with Incoming Protection Devices Nos 5 20000 100000
TOTAL OF EXTERNAL ELECTRICAL WORK CARRIED OVER TO SUMMERY 95,71,012.12
BILL OF QUANTITIES
UNDERGROUND TANKS & PUMPS
S.NO. DESCRIPTION OF ITEMS UNIT QTY RATE
SUB HEAD - PUMPS, & ALIED EQUIPMENTS
5.01 NSR Domestic Water Pump.
Providing, fixing and testing of packaged fixed drive type skid mounted hydropneumatic system
comprising of :-
Vertical, inline multistage centrifugal pumping set with stainless steel SS-304 stage casing and SS-
304 impellers with stainless steel SS-316L shaft as per IEC standards and GJL250 cast iron
suction & discharge casing, connected to TEFC ventilated induction motor of 2 pole, 2900rpm,
suitable for 400/440 Volts, 3 phase, 50 Hz A.C. supply No. of Pumps: 3 (2 Working +1 Standby)=1
Control Panel with programmable logic controller (PLC) for cyclic operation of pumps. Pump
working sequence should change after every operation.Contractor overload relays and MCBs
should confirm to IEC 898 – 1995/ specifications. Blinking indications for pumps start, trip, low
level trip, health supply should be provided in the panel along with the ammeter & voltmeter.
Control panel should also consist of cooling fan.
Pressure switches bellow type fitted with micro switch and having maximum pressure and
differential scale should confirming BS-6134 standards and IP55 protection class. Solonoid valve
at terrace tank for start stop.
Stainless steel suction and delevery header, ball valve on each pump on section delivery side,
non return valves, Y stainer complete in all respect.
Ball valves to be used should be Hot Pressed brass OT-58 with stainless steel ball and P.T.F.E
seal and O-Ring. NRVs to be used should be with Springs and O-Ring arrangement.
Complete set system to be mounted on a common base frame and shall follow following
A NSR 47 For Domestic Water Supply
Set of Three Pumps( 2 Working+ 1 Standby)
UNDERGROUND TANKS & PUMPS
S.NO. DESCRIPTION OF ITEMS UNIT QTY RATE
Capacity : app. 250 lpm
C NSR 49 Water Make up Pump to STP & Irrigation Pumps
Set of Two Pumps( 1 Working+ 1 Standby)
Capacity : app. 200 lpm
5.02 Drainage Sump Pumps
Submersible pumps for basement drainage & Pump Room drainage.
NSR Submersible single stage single entry pumps with C.I.body and C.I. two vane enclosed type
impeller connected to TEFC submersible motor for 415 volts, 3 phase, 50 cycles including MCC
panel with level controllers, auto control, sequential change over facility with one proper working at
low level & two proper working at high level with an audible alarm including all interconnectivity
cables, with both pumps connected to common outlet header including valves, non return valves,
lifting chains etc. complete in all respect
No. of Pumps: 2 (1 Working +1 Standby)=1 set
B NSR 51 For Pump Room Drainage
(Solid handiling capacity 12mm)
Capacity- 200 lpm (Each)
UNDERGROUND TANKS & PUMPS
S.NO. DESCRIPTION OF ITEMS UNIT QTY RATE
3.15 NSR Supply, Installation, Testing And Commissioning of Compact Self Contained Skid Mounted
Hydropneumatic System As Follows:(A) Vertical, In-Line, Multisage, centrifugal pumps with SS-
304 casing and impeller and SS-316 shaft, CI base & head CI material shouldbe CED coated
TEFC motor (with mechanical seal) with single VFD suitable for automatic operation and delivering
the specified discharge at the specified head,VFD should be of class IP-20 with pressure vessel,
pressure vessel should be matching of specied requirement of pump.(B) b. External Pump
mounted or wall mounted microprocessor PID controller and frequency inverter integrated in a
single body or as separate components with pressure sensor transmitter minimum two lined LCD
display, diodes to indicate pump ready, pump running and fault and capable to communicate with
other controllers following MODBUS-RTU or BACNET Class-2 protocall through RS485 port.
System should be capable to compensate for frictional losses at lower flows. All alarms should be
displayed in the controller. System should be equiped with dry running protection. ( C) Complete
(Skid mounted wall mounted / floor mounted) electrical control panel comprising of all accessories
such as PLCs, pressure switches, pressure transducers, control wiring and any other necessary
imports etc. (list to be provided by the vendor) (D)Precharged diaphram pressure vessel with food
grade membrane, charging connection, connected to outlet header with necessary flanges,
gaskets, isolating valves, nuts/bolts etc complete.(E)Set of accessories such as pressure switches,
pressure transducers, inter connecting power and control cabling etc. complete(F) Accessories like
pressure gauge, MS base frame (Synthetic enamel painted over a coat of primer)(G) GI suction
and delivery header with flanges for inlet connection, common outlet header with flanges for outlet
connections as required, and inter connecting piping with flexible connections, eccentric type
reducers etc. all necessary indigenous accessories like valves, strainer & NRV as required to
complete the installation.
NSR 52 Domestic Water booster Pumps at Terrace Each 3 2,86,523.00
Set of Three Pumps( 2 Working+ 1 Standby)
Capacity 200 LPM
HP 2.5 HP ( Approx.).
5.03 For Water level indicators with following details:
UNDERGROUND TANKS & PUMPS
S.NO. DESCRIPTION OF ITEMS UNIT QTY RATE
Underground tanks
A NSR 53 Minimum 4 level Multi level indicators with magnetic type sensor probes complete. Each 3 18,560.00
B NSR 54 Minimum 4 level Multi level indicators with magnetic type sensor probes complete. Each 3 16,230.00
5.04 NSR Providing, fixing and testing of factory fitted packaged type skid mounted pumping system
comprising of :-
Horizontal inline centrifugal pumping set with CI casing and SS-304 impellers with stainless steel
SS-316L shaft as per IEC standards and GJL250 cast iron suction & discharge casing,
a) connected to TEFC ventilated induction motor of 2 pole, 2900rpm, suitable for 400/440 Volts, 3
phase, 50 Hz A.C. supply.
Motor Control Panel with DOL starter MCB and controller for cyclic operation of pumps. Pump
working sequence should change after every operation.Contractor overload relays and MCBs
should confirm to IEC 898 – 1995/ specifications. Blinking indications for pumps start, trip, low
b) level trip, health supply should be provided in the panel along with the ammeter & voltmeter.
Control panel should also consist of cooling fan and liquid level controller with controll wiring from
UG tank to UG tank with float switch for contrlloing cut-off and cut-in of pumps and dry run
protection complete in all respects.
Suction and delivery header with Ball valves Hot Pressed brass OT-58 with stainless steel ball
c) and P.T.F.E seal and O-Ring. NRVs to be used should be with Springs and O-Ring
Complete set system to be mounted on a common base frame and shall follow following
5.04.1 NSR 55 Filter Feed Pump
No. of Pumps: 3(2Working + 1 Stand by )
Capacity : 100 lpm
UNDERGROUND TANKS & PUMPS
S.NO. DESCRIPTION OF ITEMS UNIT QTY RATE
5.05 NSR Providing and fixing vertical pressure filter with dual media filter (comprising of 600mm bed depth
of graded sand gravel and 600mm bed depth of Anthracite) fabricated from high performance M.S
plate of minimum 8mm thick for shell & 10mm thick for dished ends with top and bottom flanged
openings including top and bottom hub and lateral distribution and collection system complete with
initial charge of filter media, face piping, valves, accessories, painting, testing and commissioning
complete.(Tested to 6 Kg/m2)
Discharge : 100 lpm
Filtration Rate : 15000 lit./m2/h
Suggested dia app. : 0.60 m Each 1 1,80,950.00
5.06 NSR 57 Activated carbon Filter (Domestic Water)
Providing and fixing vertical activated carbon filter comprising of activated carbon filter media
fabricated from high performance M.S plate of minimum 8mm thick for shell & 10mm thick for
dished ends with top and bottom flanged openings including top and bottom hub and lateral
distribution and collection system complete with initial charge of filter media, face piping, valves,
accessories, Epoxy painting, testing and commissioning complete.(Tested to 6 Kg/m2)
Discharge : 100 lpm
Filtration Rate : 15000 lit./m2/h
Suggested dia app. : 0.60 m Each 1 1,85,610.00
5.07 NSR Providing, fixing, testing & commissioning of MSEP water softening plant (suitable for 3 Kg/Sqcm
working pressure) complete with initial charge with T-40 NA Resin, multiport valve with built in
ejector for controlling all operations), regeneration system and HDPE tank, pressure gauge at inlet,
outlet and back wash (each with isolation cock), valves, fittings and water hardness testing kit &
associated works. Softener shall be suitable for the following duty:
UNDERGROUND TANKS & PUMPS
S.NO. DESCRIPTION OF ITEMS UNIT QTY RATE
5.07.1 Note:The successful contractor will have to carry out a test of raw water from all the sources of
water for the Commercial, Residential & apartment at their own cost from a reputed lab as
approved by the Engineer-in-Charge / Consultant. On the basis of these results the contractor has
to submit his shop drawings, design calculations and specifications accordingly.
Please note that it is ultimately the responsibility of the contractor to provide treated water for
different use as per International Standard as given in the attached guidelines.
5.07.1 NSR 58 Raw water hardness 500 Mg/L
Treated water hardness 100 Mg/L
Regeneration Period 12 Hrs.
Capacity : 100 lpm Set 1 2,18,000.00
5.09 NSR 59 Supplying, installing, testing and commissioning of dosing system (for domestic water treatment
plant) consisting of one HDPE tank of 100 litres capacity with a positive displacement diphragm
dosing pump having variable flowrate of 0-6 lph. The motor shall be suitable for operation at 240 V
/ single phase/50 Hz. Supply. The pump shall be supplied complete with necessary polypropylene Set 1 45,707.40
piping, valves, strainers, low level switch and injection fittings. The pump shall be speed & stroke
control Asia LMI / equivalent make.
The cost shall be inclusive of providing salt for the testing and operation of system before
handover to the owner.
5.10 NSR 60 Supplying, installing, testing and commissioning of annunciation and indication panel with
interlocking arrangement complete in accordance to specification for level controller etc with Each 1 37,952.55
control cabling from field to MCC as required.
The system shall be complete to ensure automatic operation of pump in accordance to water level
in respective tanks.
5.11 NSR 61 Providing & fixing level controllers for water pumps to start/stop the pump at set level. Including
wiring, cabling from pump to panel & all other accessories as required to operate the system Each 1 76,110.52
UNDERGROUND TANKS & PUMPS
S.NO. DESCRIPTION OF ITEMS UNIT QTY RATE
5.12 NSR 62 Providing & fixing pressure switch for water pumps to start/stop the filter feed pump at set
pressure. Including wiring, cabling from pump to panel & all other accessories as required to Each 1 15,098.85
operate the system automatically.
5.13 NSR 63 Supply, installation, testing and commissioning of tanker inlet connection complete with 100 mm
dia GI (heavy) inlet piping, hose inlet connection, MS cabinet enclosure (epoxy painted after
fabriction), pad locking arrangement, inlet flexible hose complete with all necessary arrangement. Each 1 9,944.78
5.14 NSR Providing & fixing butterfly valve Rated for PN16 pressure rating. Including rubber gasket, flanges,
nuts, bolts, washers & painting complete as required.
5.15 NSR 69 Providing & fixing CI `Y' Strainer (screwed/ flanged) with stainless steel fine wire mesh perforated
sheet basket with necessary flange/ unions nuts, bolts and washers complete as required (on
UNDERGROUND TANKS & PUMPS
S.NO. DESCRIPTION OF ITEMS UNIT QTY RATE
5.16 NSR Providing & fixing dual plate CI wafer type check valve tested to a pressure of 15 Kg/sqcm.
Including rubber gasket, flanges, union, nuts, bolts, washers & painting complete as required
5.17 NSR Providing and fixing Heavy class GI pipe (IS 1239 up to 150 mm dia. and IS3589 6.35 mm
thickness above 150 mm dia.)header complete for pump suction / discharge manifold comprising
of flanges, unions, check nuts, tee elbow etc. including all flanged connections as per drawing /
site requirement. Supports from wall, floor and ceiling etc. Including dead end flanged connection
complete as required. The header size shall also include tee connections with blank flanges for the
future connections. two coats of synthetic enamel paint of approved shade as per IS : 2379 pipe
a) NSR 72 50 mm dia RM 10 821.71
5.18 NSR 76 Providing & fixing neoprene rubber double flanged rubber expansion joint (anti vibration bellow)
of standard length as per manufacturers specifications. suitable for hydrostatic test pressure of 15
kg/sqcm including all necessary fittings i.e. rubber gasket, nuts, bolts, washers etc complete as
UNDERGROUND TANKS & PUMPS
S.NO. DESCRIPTION OF ITEMS UNIT QTY RATE
5.20 NSR Providing & fixing brass ball valve with CW617N grade brass with hard chrome plated ball inside
PTFE (Teflon) seat & ring with chrome plated centre handle with female BSP threads tested to a
pressure not less than 15 Kg / sqcm complete:in all respects.
SUB HEAD VII -ELECTRICAL PANEL BOARDS FOR PHE WORKS.
7.1 NSR 81 CUBICAL PANEL BOARD - PLUMBING
i) For 2 x 3.0 HP Domestic Water fixed speed hydroneumatic Pumps (1 duty + 1 stand by) Item 1 3,48,856.93
ii) For 2 x 2 HP sump Pump (1 Duty + 1 Stand by)
Supply, installation, testing and commissioning of Cubical type sectionalised floor standing switch
board of 31 MVA fault capacity at 415 V complete with 3.5 strip, 160 A capacity Aluminium Bus -
Bar Electrolytic grade, cable alley, switchgears of following capacity & as per specifications.
100 A TP MCCB with heavy duty solid neutral link with (0-100A) ammeter with 3 CT and selector
switch, (0 - 500 V) voltmeter with selector switch, phase indication light with protection fuse. - 01
i) i) For 2 x 3.0 HP Domestic Water fixed speed hydroneumatic Pumps (1 duty + 1 stand by)
II) For 2 x 2 HP sump Pump (1 Duty + 1 Stand by)
UNDERGROUND TANKS & PUMPS
S.NO. DESCRIPTION OF ITEMS UNIT QTY RATE
40 A TP MCB with 40 A DOL starter, overload relay, 96 mm (0-40A) ammeter with single CT, start
/ stop push buttons, on / off / trip indication lights with protection fuse, single phase preventer. - 01
25 A TP MCB with 25 A DOL starter, overload relay, 96 mm (0-25A) ammeter with single CT, start
/ stop push buttons, on / off / trip indication lights with protection fuse, single phase preventer. - 01
SUB HEAD RO SYSTEM
Supplying, lifting at the terrace, assembly, erection, testing and commissioning of RO Water
treatment system including centalised water cooler for cold water provided all its components of
required size as per water test analysis to make the water suitable for drinking, complete including
the following as mentioned below. The cost will include testing of permeate water sample from a
CPCB approved test laboratory, generating and providing membrane analysis data form the
licensed manufacturer's software etc.
Permeate water quantity = 200 lit/hr.
Minimum Recovery = 70%-75%
Raw Water Characteristics - As per Water Test Analysis Report of Shriram Test Laboratory to be
got done by the supplier
Raw water Quality
Total Dissolved Solids: < 990 PPM
Turbidity : <1NTU
Chlorides : 205 ppm
Sulphates : 105 ppm
Treated Water Quality
Turbidity : <1NTU
Chlorides : < 10 ppm
Sulphates : < 5 ppm
UNDERGROUND TANKS & PUMPS
S.NO. DESCRIPTION OF ITEMS UNIT QTY RATE
a SS Vertical centrifugal Raw Water Pump (1 Working + 1 Stand-by)
b FRP Dual Media Filter
c Activated Carbon Filter
c Antiscalant Dosing System including pump chemical dosing pump, tanks etc.
d Polypropylene Micron/cartridge Filter and SS housing
Stainless steel vertical multistage inline high pressure pump (1 Working) including dry running
f Spirally wounded 6 nos. of RO Membranes
g Composite FRP RO pressure tube/vessel
h Automatic RO Module Cleaning System including chemical pump, cartridge filter, tanks etc.
i pH correction system incl. chemical dosing pump, tanks etc.
Instrumentation including flow meters, digital TDS meter, digital pH meter, pressure gauges, low
pressure switch, high pressure switch etc. complete.
SS-316L (8 kg/cm2) piping and ABS valves for low pressure and SS-316, schedule 10 piping and
SS-316 L valves for high pressure piping in the plant.
Electrical panel including all starters, overload relays, single phase preventers, voltmeters,
l ammeters, MCB's, indicating lights, push buttons, rocker switches, incomers, auto-manual
switches etc. complete.
m All cabling , connections, terminations etc. required for the job. Each 1 1,80,000.00
TOTAL OF UNDERGROUND TANK & PUMPS CARRIED TO SUMMARY
WRPC ANDHERI WEST MUMBAI
SCHEDULE OF WORK
SLOID WASTE (ORGANINC & INORGANIC WASTE ) DECOMPOSITION MACHINE
S. No. DSR-2023/ Description of items Unit Qty. Rate Amount
Supply of the solid waste (organic waste ) Semi-Automatic Compost machine
with curing system for 50-60 kg/day
Waste Processing Capacity: 50-60 kg/day
Composting Method: Micro- Organism Based Natural Composting
Cycle Operation Time: 10-15 Min. Approx.
Input: All kinds of Segregated Organic Waste.
Output: Organic Manure.
Volume Reduction: 80-85%
Dimension of Machine: AS PER OEM (in feet)
Electrical Supply: 415-440 V (3 phase supply)
Tank Capacity: 45 Liters
Shredder Motor Rating: 2 HP
Composting Motor Rating: 2 HP
Composting Tank Material: S.S.304
External Body Material: MS Powder Coated
Composter Gearbox: Make-Classic
Shredder Blade: Alloy Steel (EN 8)
Supply Installation Testing and Commissioing of the curing system (basket type
with baskets and stand frame decompost machine at site as per site-in-charge.
3 MR Forwarding , pakaging and freight charges Nos. 1 10000 10,000
Installation Testing and Commissioing of the Semi automatic decompost
machine at site as per site-in-charge.
SLOID WASTE (ORGANINC & INORGANIC WASTE ) DECOMPOSITION MACHINE
S. No. DSR-2023/ Description of items Unit Qty. Rate Amount
Includeing OTHER REQUIREMENTS TO BE ARRANGED AT SITE:-
Spacerequirement:sq.ft that includes segregation, Treatment and storage area.
Shed with PCC platform,chain-link or Green net at surroundings
and AC Sheet Roof.
1)3HP,3Phase Power supply with Neutral
I)32/40 Amp-4 Pole MCB –1No.for MACHINE
2)Single Phase–5 Amp–3 Pin Switch Socket
I)2 Nos.for Double Curing System
Single Phase connection–3 Nos for Tube Lights and Fan 1/2” Dia Tap for water
connection.(Regular)
TOTAL OF EXTERNAL FIRE FIGHTENING WORK CARRIED OVER TO
aoc.pdf