Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹98.8 LAccepted-Finance | L1 | Accepted-Finance QUALIFIED | |
| 2 | L2₹100.0 L+₹1.2 L (1.21%)Accepted-Finance | L2 | Accepted-Finance QUALIFIED | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹99 L
EMD Value
₹99,000
Closing Date
25 Oct 2024, 1:00 pmClosed
SE EDC-I BSR
SE EDC-I HYDEL COLONY BULANDSHAHR
Works related to system strengthening, construction of sub-centres, capacity increase, construction of HT line, dilapidated wires, replacement of poles etc.
2024_PVVNL_963857_1
T-48/EDC-I/B/2024-25
Open Tender
Electrical Works
Item Rate
30 days
BULANDSHAHR
PLZ REFER TENDER DOCUMENT
2 documents required · 2 mandatory
₹3,540
SE EDC-I
₹99,000
26 Oct 2024
9 Oct 2024
25 Oct 2024
9 Oct 2024
25 Oct 2024
9 Oct 2024
Amount
fctusl Iyku ;kstuk ds vUrxZr fo|qr forj.k [k.M&[kqtkZ ds dk;Z{ks= esa iz.kkyh lqn`hdj.k] midsUnzks ds fuekZ.k] {kerko`f)] ,p0Vh0 ykbZu fuekZ.k] ttZj rkj] iksy cnyus laca/kh bR;kfn dk;ZA
Safe carriage of stor mattrial from store center to site store with loading & unloading at both ends respectively without contractor porvading all item distance within- 0 to 50 Kms.
PCC Poles 8.5 mtr. long
PCC Poles 9 mtr. long
ST Poles 11 mtr. long
Loading, Safe carriage & unloading of heavy stock material V Type, Disc Insulator, Pin Insulator, channel, Angle and other site requerment any mattrial ETC from store center to site store with proper stacking of material, distance within-70Kms.
Loading, Safe carriage & unloading of LT/HT cable, T/F, VCB & control panal etc from store center to site store with proper stacking of material, distance within-70Kms.
LT T/F Lead any size
3x300 Sq.mm. XLPE Cable 11 KV
3x185 Sq.mm. XLPE Cable 11 KV
3x300 Sq.mm. XLPE Cable 33 KV
3x120+1x95+1x16 Sq mm AB Cable
3x95+1x50+1x16 Sq mm AB Cable
3x50+1x35+1x16 Sq mm AB Cable
ACSR Dog Conductor
ACSR Rabit/Wisel Conductor
11 Kv VCB
T/F 10 KVA 11/0.25 KV
T/F 25/63/100 KVA 11/0.4 KV
T/F 250 KVA 11/0.4 KV
33 KV Fuse Set complet
11 KV Fuse Set complet
Earthing rod all type
DISTRIBUTION BOX 3 PHASE Complet
Erection of Single pole ST Pole 11 mtr long of 33 KV fittings as per RESPO Drawing Top Channal, Dropper Channal, X Bracing Set, Disc Insulator, Pin Insulator, Guarding Angle F Bracket and etc as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Erection of Dobule pole ST Pole 11 mtr long of 33 KV fittings as per RESPO Drawing Top Channal, Dropper Channal, X Bracing Set, Disc Insulator, Pin Insulator, Guarding Angle F Bracket and etc as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Excavation of For Each and grouting of Single Pole as per RESPO Drawing and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. The support shall be grouted with cement, sand and stone ballast in ratio 1:4:8 including the cost of Cement, Sand, Bricks/Stone Ballast, etc. as per actual site requirement
Excavation of For Each and grouting of Dobule Pole as per RESPO Drawing and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. The support shall be grouted with cement, sand and stone ballast in ratio 1:4:8 including the cost of Cement, Sand, Bricks/Stone Ballast, etc. as per actual site requirement
Provading & Fixing of Planth of pole/Kiking of pole up nuturel Ground level.
Fixing of Garding of 11 Kv line 6/8 SWG wire.
Fixing of 11 Kv stay set
Grouting of 11 Kv stay set including the work of nozelling etc. as per RESPO manual and also including the cost of all The support shall be grouted with cement, sand and stone ballast in ratio 1:4:8 including the cost of Cement, Sand, Stone Ballast, Stone etc. as per actual site requirement , labour, T&P etc required for proper completion of work.
Laying sagging stringing and binding and jumpering in air area etc of following ACSR Conductor/ wisel/Rabit/ABC all size on the newly erected poles as per RESPO manual and as per direction of Supervising Engineer. It includes the cost of labour, T&P, carrier etc. required for proper completion of work.
LT T/F Lead any size
3x300 Sq.mm. XLPE Cable 11 KV
3x185 Sq.mm. XLPE Cable 11 KV
3x120/185 Sq.mm. XLPE Cable 33 KV
3x120+1x95+1x16 Sq mm AB Cable
3x95+1x50+1x16 Sq mm AB Cable
3x50+1x35+1x16 Sq mm AB Cable
ACSR Dog Conductor
ACSR Rabit/Weasel Conductor
Fixing of 11 Kv Cable jointing kit I/D
Fixing of 33 Kv Cable jointing kit I/D
Fixing of 11 Kv VCB
Fixing of T/F 10 KVA 11/0.25 KV
Fixing of T/F 25/63/100 KVA 11/0.4 KV
Fixing of T/F 250 KVA 11/0.4 KV
Making Jumpers on Section Points, by fixing of proper sizes, suitable for ACSR Conductor. Sectional Double/Four Pole.
Providing OF Danger Plate.
Fixing of Danger Plate.
Testing and commissioning of 11 kv VCB.
Providing & Fixing of Chemicle earthing Electrod rod.
Providing of G.I. Pipe for cable D/P
Fixing of G.I. Pipe for cable D/P
Drilling of Two Parallel bores by trench less Method by horizantal Boring by HDD Machine at RESPO ground Level For 11/33 kv cable
Providing of HDPE Pipe For 11/33 kv cable off size
Fixing of HDPE Pipe For 11/33 kv cable off size
Providing Interconnecting 6 Mtr. Long Pieces of HDPE Pipe shocket.
Fixing and Interconnecting 6 Mtr. Long Pieces of HDPE Pipe shocket.
Digging of Pits Of Size 4 Mtr X 4 Mtr X 1.5 Mtr. For Cable Loop
Restoration of Pit After Laying Of Cable loop
Restoration of kacha Road After Laying Of Cable.
Digging of cable trench for all type cable laying
11/33 KV XLPE Cable laying OVERHEAD
G.I.Wire 6/8 SWG
Fixing of T Off channel.
Fixing of Stone Pad
Providing & Fixing barbard wire
Fixing of Top/Drop channel Set
Fixing of MS Angle 65x65x6 Set
Fixing of 11 KV V CROSS-ARM
Fixing of 33 KV V CROSS-ARM
Provading of Nut-Bolts off size
Fixing of Garding Angle
Fixing of Nut-Bolts off size
Provading of Nut-Bolts off size for distubation box and No. plate/danger plate
Fixing of Nut-Bolts off size for distubation box and No. plate/danger plate
THE WORK OF MAKING 0F T/F PLANTH FOR 250/400 KVA T/F
THE WORK OF MAKING 0F T/F FANCING MS Angle & Jalie FOR 250/400 KVA T/F
Fixing of DISTRIBUTION BOX 3 PHASE
Provading of Peircing Clamp all size
Fixing of Peircing Clamp all size
Provading of Lock for distribution box
Fixing of Lock for distribution box
Provading of GI-Hook for guarding.
Fixing of GI-Hook
Fixing of Cross Bracing
Provading of J-Hook
Fixing of J-Hook
Provading of Dead End Clamp/Suspension Clamp
Provading & Fixing all tipe Cross arm Clamps.
Provading & Fixing F Clamps.
Provading & Fixing PRC
Provading & Fixing I Bolt.
Provading & Fixing TF Clamps.
Provading & Fixing LT Clamps.
Fixing of Dead End Clamp/Suspension Clamp
Fixing of 33 KV Fuse Set
Fixing of 11 KV Fuse Set
Provading of Stay insulator
Fixing of Stay insulator
Disconnecting the connection before starting the work and reconnecting it to the distribution box after completion of the work per unit.
Painting of Pole
Fixing of 11/33 Kv Stay Set complet
Fixing of 11/33 Kv Stay Set wire
Fixing of 11 KV pin Insulator
Fixing of 11 KV Disc Insulator
Fixing of 33 KV pin Insulator
Fixing DP CLAMP
Fixing of 33 KV Disc Insulator
Vivek Electricals
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .