| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.8 LAccepted-AOC HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹14.5 L+₹1.7 L (12.9%)Rejected-Finance AIRPORT ROAD SKALZANGLING LEH LADAKH 194101 | LEH LADAKH | LADAKH | 194101 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹14.6 L+₹1.8 L (14.0%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD PIN 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹15.6 L+₹2.8 L (21.6%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹41,000
Closing Date
9 Aug 2021, 6:00 pmClosed
Col S S Babu
Headquarters 138 Works Engineers Pin-914138 C/o 56 APO
SPECIAL REPAIR TO LT PANELS AND LT CABLES UNDER GE 865 EWS AT LEH
2021_MES_459080_1
138WE/L-38/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 865 EWS
As per NIT
8 documents required · 8 mandatory
₹500
GE 865 EWS
₹41,000
Yes
1 Sept 2021
12 Jul 2021
11 Aug 2021
12 Jul 2021
9 Aug 2021
26 Jul 2021
Amount
Excavation in trenches n exc 1.5 m wide and n. exc 1.5 m in depth, for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n exc 10 Sqm on plan and n exc 1.5 m in depth and getting out in soft and loose soil complete all as specified and as directed.
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed. Note: Punned thickness shall be measured.
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type-I, flat, size 250mmx150mmx40mm, complete all as specified and directed.
M&L GI tubing light grade of 100 mm dia bore with all fittings and fixtures laid in trenches complete all as specified and directed.
M&L GI tubing light grade of 50 mm dia bore with all fittings and fixtures laid in trenches/ floor or fixed to wall complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil, complete all as specified and directed.
Removing surplus excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed.
M&L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 300 Sqmm 3.5 core, laid in trenches or passing through pipes, ducts or fixed to wall /poles including making necessary connections at both ends, complete all as specified and as directed.
M&L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 70 Sqmm 3.5 core, laid in trenches or passing through pipes, ducts or fixed to wall /poles including making necessary connections at both ends, complete all as specified and as directed.
M&L XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 25 Sqmm 4.0 core, laid in trenches or passing through pipes, ducts or fixed to wall /poles including making necessary connections at both ends, complete all as specified and as directed.
M&L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm 4.0 core, laid in trenches or passing through pipes, ducts or fixed to wall /poles including making necessary connections at both ends, complete all as specified and as directed.
M&L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 6 Sqmm 2.0 core, laid in trenches or passing through pipes, ducts or fixed to wall /poles including making necessary connections at both ends, complete all as specified and as directed.
Supply, Instalation, Testing and Commissioning in replacement of LT Panel cubical type out door floor mounted weather proof totally enclosed, (CPRI approved ) factory made and made out of 3 mm thick CRCA powder coated sheet and angle iron complete with bus bar of Aluminium of suitable size for capacity 800 Amps 3 phase and neutral 415 volts 50 Hz mounted on epoxy type insulator with PCC flooring and angle iron base frame including taking down of old unserviceable panel complete all as specified and as directed for the following:-
(a) MCCB 400 Amps Cap 4 Pole 36 KA 415 volts - 02 Nos for incoming
(b) MCCB 400 Amps Cap 4 Pole 36 KA 415 volts - 01 Nos (Bus Coupler)
(c) MCCB 320 Amps Cap 4 Pole 25 KA 415 volts - 04 Nos
(f) LED Indicating Lamp - 02 Set
(g) Protection MCB 6 A SP - 18 Nos
Note:- (i) The Bus coupler MCCB should be interlocked with the incoming MCCB by Mechanically and Electrically.
(ii) The Design of Panel, Make of Complete accessories and drawing of LT Panel should be submitted by the contractor for pre- approval from Engineer-in Charge before order and execution at site. (IB Pump House).
S&F Sheet metal enclousers with 4 Nos insulated Bus bar of capacity 100 Amps 6 Way capacity with epoxy insulators and at bottom opening for cable connection with 50x6mm thick angle iron base frame including PCC foundation and connecting of incoming and out going cables complete including taking down old unserviceable bus bar complete all as specified and as directed.
S&F On Load Change over switch 415 volts in sheet metal enclousers 4 Pole of capacity 200 Amps with connecting accessories complete including taking down old unserviceable change over complete all as specified and as directed.
Supply, Instalation, Testing and Commissioning in replacement of LT Panel cubical type out door floor mounted weather proof totally enclosed, (CPRI approved ) factory made and made out of 3 mm thick CRCA powder coated sheet and angle iron complete with bus bar of Aluminium of suitable size for capacity 400 Amps 3 phase and neutral 415 volts 50 Hz mounted on epoxy type insulator with PCC flooring and angle iron base frame including taking down of old unserviceable panel complete all as specified and as directed for the following:-
(a) MCCB 200 Amps Cap 4 Pole 25 KA 415 volts - 01 Nos for incoming
(b) MCCB 63 Amps Cap 4 Pole 16 KA 415 Volts - 02 Nos
(c) MCCB 40 Amps Cap 4 Pole 16 KA 415 Volts - 03 Nos
(f) LED Indicating Lamp - 01 Set
(g) Protection MCB 6 A SP - 18 Nos
Note :- (i) The Bus coupler MCCB should be interlocked with the incoming MCCB by Mechanically and Electrically.
(ii) The Design of Panel, Make of Complete accessories and drawing of LT Panel should be submitted by the contractor for pre- approval from Engineer-in Charge before order and execution at site. (Near Highmast)
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground.(earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr. Below ground level connecting to galvanised iron strip 25x4mm as earth lead by means of bolts, check nuts and washers of GI and earth strip protected by provision of GI pipe light grade, 40mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM ( weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil,returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I and connection all as specified and testing on completion. Note: The cost of excavation and earth work, PCC pit and pit covers, funnel and watering pipe, wire mesh, charcoal dust and common salt, 40mm dia, medium grade, GI pipe as protection to earth lead and earth lead as 32x6mm dia GI strip (main earthing lead from earth electrode to test point length not less than 7.5mtrs) shall be deemed included in the unit rate for earthing.
M/S NANCY ENTERPRISES
national engineering
M.S Sharma Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .