| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.6 LAccepted-AOC | L1 | Accepted-AOC Being a lowest bidder | |
| 2 | L2₹21.1 L+₹19,246 (0.92%)Rejected-Finance 0 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹21.8 L+₹88,158 (4.22%)Rejected-Finance 23 6 C LAL VIHAR EAST END BAMRAULI PRAYAGRAJ 211012 U P | PRAYAGRAJ | UTTAR PRADESH | 211012 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹24.8 L+₹4.0 L (19.0%)Rejected-Finance 41B 1H JAYANTIPUR PREETAM NAGAR ALLAHABAD | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹29.7 L+₹8.8 L (42.2%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹36.9 L
EMD Value
₹73,800
Closing Date
3 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Bamrauli
GE (AF) Bamrauli
SPECIAL REPAIR/REPLACEMENT OF POWER SUPPLY INFRASTRUCTURE FOR OMQS AT NEW PROJECT AND OTHER SANCTION WORK AT AF STN BAMRAULI
2024_MES_662871_1
8919/E8
Open Tender
Civil Works - Others
Works
180 days
GE (AF) Bamrauli
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE (AF) Bamrauli
₹73,800
Yes
15 Oct 2024
29 Jun 2024
5 Sept 2024
29 Jun 2024
3 Sept 2024
13 Jul 2024
Amount
Taking down carefully aluminium batten point, wiring for light/fan/socket/bell or power point including. All fittings i.e. switch, sockets, ceiling rose, regulators, batten holders, etc. Complete and making good disturbed surfaces of wall/floor to match with the surroundings of wall/ceiling/floor etc including taking down old light fittings. Note :- (i) Contractors quoted rate of this item deemed inclusive of unscrewing of the serviceable fittings and fixture as directed and deposit in MES store yard. (ii) Quoted rate also deem to be included cost of cutting chases for taking out concealed conduit and nitch for terminal box. (iii) Decision of GE shall be final and binding in respect of serviceability of fittings/fixture.
M&L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLSH cable 1100 volts grade with multi stranded copper conductor drawn through new PVC concealed conduit mediem grade, ISI marked and including provision of 1.5 sqmm PVC insulated copper cable FRLSH as earth continuty, fabricated branded modular metal flush box duly make embossed, concealed in walls with suitable modular inner and outer plate for housing switches , socket outlet and fan regulators etc, complete all as specified and as directed for the followings:-
(a) One light/fan/bell point controlled by one switch single pole one way
(b) All as per item No 2 here-in-before but one 3 pin 6 amp switch socket out let independent .
(c) All as per item No 2 here inbefore but one 3 pin 6 amps socket outlet on the same board with other switch complete .
All as per item No 2 here-in-before but using 02 Nos. 4.0 sq mm size for main cable and 01 No.4 sq mm size as earth conductor for one 16 Amp switch socket outlet on independent board.
S&F switch modular flush 6A single pole one way ISI marked
S&F modular sockets 6 Amp 2 in 1 2/3 pin combined all as specified and directed.
S&F switch modular flush type 15/16 Amp single pole one way 240 volt one module ISI marked
S&F modular sockets 16 Amp 2 in 1 3/5 pin combined all as specified and directed.
S&F Modular bell push flush type 5 Amps single pole 230 Volt white white finish complete all as specified and directed.
S&F ceiling rose surface bakelite 60x25mm three terminal
S&F electronic step type fan regulator 240 volt 50 Htz 120 watt (switch/sockets type in shape) modular type
S&F in replacement white cover plate with frame one module for modular switches and sockets complete all as specified and directed.
S&F in replacement white cover plate with frame two module for modular switches and sockets complete all as specified and directed.
S&F in replacement white cover plate with frame three module for modular switches and sockets complete all as specified and directed.
S&F in replacement white cover plate with frame four module for modular switches and sockets complete all as specified and directed.
S&F in replacement white cover plate with frame six module for modular switches and sockets complete all as specified and directed.
S&F in replacement white cover plate with frame eight module for modular switches and sockets complete all as specified and directed.
S&F in replacement white cover plate with frame twelve module for modular switches and sockets complete all as specified and directed.
S&F in replacement white cover plate with frame sixteen module for modular switches and sockets complete all as specified and directed.
S&F metal flush box 1/2 modul 1.6 mm for mounting modular switches and sockets complete all as specified and directed.
S&F metal flush box three module 1.6 mm for mounting modular switches and sockets complete all as specified and directed.
S&F metal flush box four module 1.6 mm for mounting modular switches and sockets complete all as specified and directed.
S&F metal flush box six module 1.6 mm for mounting modular switches and sockets complete all as specified and directed.
S&Fx metal flush box eight module 1.6 mm for mounting modular switches and sockets complete all as specified and directed.
S&F metal flush box twelve module 1.6 mm for mounting modular switches and sockets complete all as specified and directed.
S&F metal flush box sixteen module 1.6 mm for mounting modular switches and sockets complete all as specified and directed.
S&F MCB DB SPN12 way, double door, IP-43, IK-09, Isolated Neutral Bar and fixed flush to wall and suitable for universal mounting complete all as specified and directed.
S&F MCB, single pole and neutral, 230 volts, 40 to 63 Amp rating, 'C' series fixed in DBs catered here-in-before.
S&F MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge
S&F calling bell Ding dong as specified and directed.
M&L for Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 4 sqmm FRLSH, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 4 sqmm FRLSH 1100 volts grade cable continuous earth wire of green colour code complete. Note:- (a) Two runs of 4 sqmm cable and one run of 4 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish.
M&L for Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 6 sqmm FRLSH, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 6 sqmm FRLSH 1100 volts grade cable continuous earth wire of green colour code complete. Note:- (a) Two runs of 6 sqmm cable and one run of 6 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish.
S&F sheet metal enclosure with socket and plug top and MCB single pole and neutral enclosure with two Pin and earth plug and socket complete with one single pole MCB, 240 V, 20 Amp.
S&F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
S&F LED Light fitting mirror type with high out put diffuser 2 feet ,10watt ,220 v AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
S&F ceiling fans Robust and reliable inverter motor (brush less DC Motor) powered by ECM technology, BEE 5 star rating for energy saving, AC single phase 230/240 V of size 1200 mm sweep including making connection with three core flexible, copper cable pvc insulated of suitable length incl taking down old & deposited to MES store yard complete all as spd & directed. Note : Cost of remote cell included in this item
S&F wall mounted fan 400mm, 230 volts , 50 Hz 1420 RPM with 90 degree oscillation and having speed control by two pull cord system all as specified and directed.
S&F in repair Ventilating Fan 250mm sweep, non metallic resin body, single phase 240 volts AC 50 Hz including louvers, and copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all aspecified and directed by Engineer-in-Charge. Note : Old material deposited to MES store Yard
S&F exhaust fan, steel body AC single Phase. 230V of size 300m sweep heavy duty 1400 RPM with, blades, and frame and louvers complete with all accessories for hang and connecting with 3 run of 1.5 sqm, multicore, PVC insulated copper cable from ceiling rose as specified and directed.
Taking down carefully from existing place ceiling fan and removing to MES store yard Scraping, cleaning greasing/oiling and refixing at site complete incl electric connection with three core flexible wire 1.5 Sqmm and writing MES No all as specified and directed.
Cutting the existing wall/removing existing steel bar to make a hole for fixing of ventilation fan through packing of wooden ply to support the ventilating/ air circulating fan including necessary nut and bolts of suitable size incl making good of disturbed surface complete all as directed by Engr-in charge.
S&F in repair factory made epoxy powder coated Load line Distribution Board TPN-4 ways with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including insulated 200 Amp copper bus bar, Isolated neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB any capacity as incomer and 6 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623.
S&F in repair MCCB 160 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core
S&F connecting and testing LED street light 35 watt 6000k/3000k new generation energy saving and environmental friendly long life led street light made up of pressure die cast aluminium housing with high efficient led as lighting source and PC cover having toP opening seperate driver compartment with IP66 protection and impact resistance of IK07 roadway luminaries with high power LED as light source and electronic driver complete with connection and accessories for fixing with with including grade 40mm dia GI pipe as bracket in appropriate length complete including taking down old light fitting
Taking down carefully unserviceable distribution boards including disconnecting of incoming and outgoing connections complete all as specified and directed.
S&F MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
S&F MCB SPN 32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge
S&F factory made epoxy powder coated Distribution board (MCCB DB) TPN 4 way vertical type, IP - 43 Protection made out of min 1.6 mm thick CRCA sheet, fabricated, metal double door fixed to wall and suitable for universal mounting and including 200 Amps rated copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removeable gland plated with knockouts and suitable for TPN MCCB 125/160 Amps as incomer and 12 SP or 04 Nos TP MCBS as outgoing complete all as specified and confirming to IS : 8623 complete all as specified and directed.
S&F Sub main wiring complete with two runs of 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through PVC conduit in walls all as specified and as directed.
S&F Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 10 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through non metallic conduit in walls all as specified and as directed.
S&F blank plate of suitable size for open space in distribution boards complete all as specified and directed.
S&F flood light for building illumination 30 watt 240 volt 50 Htz 3000/6500K 120 lumen/watt IP-65 protection.
S&F in repair MCCB 125 Amps, FP 415 volts 25 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge.
S&F in repair MCCB 100 Amps, FP 415 volts 25 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge.
S&F in repair MCCB 63 Amps, FP 415 volts 25 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge.
M&L for in replacement for only twin core PVC insulated unarmoured cable 10 Sqmm Flat 1100 Volts with Aluminium multi stranded conductor complete all as specified and directed by Engr-in-Charge.
M&L for in replacement for only twin core PVC insulated unarmoured cable 6 Sqmm Flat 1100 Volts with Aluminium multi stranded conductor complete all as specified and directed by Engr-in-Charge.
MYL for Earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron wire 4mm dia as earth lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No. 3, MES SSR Part I- 2009 with 15 mm dia medium grade GI pipe as a protection to earthing lead and 20 mm dia medium grade GI pipe for watering purpose including excavation & earth work in any type of soil, funnel, wire mesh, RCC pit with cover, cast iron frame complete and connected to earthing test point all as specified or indicated including testing on completion. Notes (i) The concrete pit shall be PCC (1:3:6) type C-1, 40mm thick precast cover slab of RCC with suitable Mild steel handle in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I (ii) PCC pit shall be provide at least 500 mm away from the earth pit and not on just on the eath pit and extra cost of additional length of water pipes and fittings junction etc shall be deemed to be included in the rate. (iii) Item includes the cost of 7.5 metre earth lead wire and GI pipe for protection of earth wire. Any varriation in quantity shall be adjusted.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire
S&F in replacement PVC box comprising of switch socket combination multi - purpose 5 pin, 6/16 Amp box type complete all as specified and as directed.
M&L for preparing newly plastered surface and apply a coat of 1.5/2 mm thick wall care putty for making smooth surface and applying two coats of distemper oil emusion over coat of primer on surface of walls
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material
A S ENTERPRISES (BID ID -3076195)
Pleiad Complex On (BID ID -3079596)
Bharat Trading Company (BID ID -3079839)
Ambrish Builders (BID ID -3078825)
M/S MALHOTRA ENGINEERING WORKS (BID ID -3068194)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .