| 1 | | Digital Panel Ammeter range (0-400A)A.C, Specifications,-1.Measured scale- A.C R.M.S value 2.3-1/2 digit Seven segment red color 1Inchdisplay 3.CT Ratio 400/1 4.Opearting frequency of the system,50Hz 5.Size-96X96mm 6.Accuracy,0.5% of fsd 7.Test Voltage, 2KV for 1 Min. 8.A.C Input to meter , 0-1Amp. A.C 9.Operating Temp., 0 Deg. To + 55 Deg.10.Conforms to , I.S.1248/I.E.C 60051(Part 2) 11.Enclosure ,IP20 & IP50(Back & Front). 12.Mounting-Vertical flush mounting, 13. Aux supply, 40V-300V AC/DC, 14.Shape,Square 15.Mounting fastens/Clamps ,Easy mountable clamps &Nuts. Standard Make AE/RISHABH/Equivalent | 5 | NO | Arjun Ghosh 473111,NATIONALFERTILIZERS LIMITED VIJAIPUR | 60 |
| 2 | | Digital Panel Ammeter range (0-500/A)A.C,Specifications,-1.Measured scale- A.C R.M.S value 2.3-1/2 digit Seven segment red color 1Inchdisplay 3.CT Ratio 500/1 4.Opearting frequency of the system,50Hz 5.Size-96X96mm 6.Accuracy,0.5% of fsd 7.Test Voltage, 2KV for 1 Min. 8.A.C Input to meter , 0-1Amp. A.C 9.Operating Temp., 0 Deg. To + 55 Deg.10.Conforms to , I.S.1248/I.E.C 60051(Part 2) 11.Enclosure ,IP20 & IP50(Back & Front) 12.Mounting-Vertical flush mounting,13. Aux supply, 40V-300V AC/DC 14.Shape,Square 15.Mounting fastens/Clamps ,Easy mountable clamps &Nuts. Standard Make AE/RISHABH/Equivalent | 5 | NO | Arjun Ghosh 473111,NATIONALFERTILIZERS LIMITED VIJAIPUR | 60 |
| 3 | | Digital Panel Ammeter range (0-1000/A)A.C, Specifications,-1.Measured scale- A.C R.M.S value 2.3-1/2 digit Seven segment red color 1Inchdisplay. 3.CT Ratio 1000/5 4.Opearting frequency of the system,50Hz 5.Size-96x96mm 6.Accuracy,0.5% of fsd 7.Test Voltage, 2KV for 1 Min.8.A.C Input to meter , 0-5Amp. A.C 9.Operating Temp.,0 Deg. To + 55 Deg.10.Conforms to , I.S.1248/I.E.C 60051(Part 2)11.Enclosure,IP20 & IP50(Back & Front) 12.Mounting-Vertical flush mounting 13.Shape,Square ,14. Aux supply, 40V-300V AC/DC 15.Mounting fastens/Clamps ,Easy mountable clamps &Nuts. Standard Make AE/RISHABH/Equivalent | 5 | NO | Arjun Ghosh 473111,NATIONALFERTILIZERS LIMITED VIJAIPUR | 60 |
| 4 | | Digital Panel Ammeter range (0-800/A)A.C,Specifications,-1.Measured scale- A.C R.M.S value 2.3-1/2 digit Seven segment red color 1Inchdisplay 3.CT Ratio 800/1 4.Opearting frequency of the system,50Hz 5.Size-96X96mm 6.Accuracy,0.5% of fsd 7.Test Voltage, 2KV for 1 Min. 8.A.C Input to meter , 0-1Amp. A.C 9.Operating Temp., 0 Deg. To + 55 Deg.10.Conforms to , I.S.1248/I.E.C 60051(Part 2) 10.Enclosure,IP20 & IP50(Back & Front).11.Mounting-Vertical flush mounting, 12. Aux supply, 40V-300V AC/DC 13.Shape,Square 14.Mounting fastens/Clamps ,Easy mountable clamps &Nuts. Standard Make AE/RISHABH/Equivalent | 5 | NO | Arjun Ghosh 473111,NATIONALFERTILIZERS LIMITED VIJAIPUR | 60 |
| 5 | | Digital Panel Ammeter range (0-2000A)A.C, Specifications,-1.Measured scale- A.C R.M.S value 2.3-1/2 digit Seven segment red color 1Inchdisplay 3.CT Ratio 2000/5 4.Opearting frequency of the system,50Hz 5.Size-96X96mm 6.Accuracy,0.5% of fsd 7.Test Voltage, 2KV for 1 Min.8.A.C Input to meter,0-5Amp.A.C 9.Operating Temp.,0 Deg. To + 55 Deg.10.Conforms to , I.S.1248/I.E.C 60051(Part 2), 11.Enclosure ,IP20 & IP50(Back & Front)12.Mounting-Vertical flush mounting 13. Aux supply, 40V-300V AC/DC 14.Shape,Square 15.Mounting fastens/Clamps ,Easy mountable clamps &Nuts.Standard Make AE/RISHABH/Equivalent | 5 | NO | Arjun Ghosh 473111,NATIONALFERTILIZERS LIMITED VIJAIPUR | 60 |
| 6 | | Moving coil with rectifier type, analog Ammeter range (0-100/600Amp)A.C, without C.T Specifications,-1.Measured scale- A.C R.M.S value 2.Movement-Moving coil annular self shielded spring mounted jewel suspension. 3.CT Ratio 100/1 4.Opearting frequency of the system,50Hz 5.Size-96x96mm 6.Scale,Fullscale deflection 240 degree with end suppressed scale 7.Accuracy,1.0% 8.Test Voltage, 2KV for 1 Min. 9.A.C Input to meter , 0-1Amp. A.C 10.Operating Temp., 0 Deg. To + 50 Deg.11.Conforms to , I.S.1248/I.E.C 60051(Part 2) 12.Case-white 13.Housing Material, ABS 14.Glass Face plate, Flat glass ,clear transparent 15.Mounting-Vertical flush mounting 16.Shape,Square, 17.Mounting fastens/Clamps ,Easy mountable clamps &Nuts.Standard Make AE/RISHABH/Equivalent | 5 | NO | Arjun Ghosh 473111,NATIONALFERTILIZERS LIMITED VIJAIPUR | 60 |
| 7 | | Digital Panel Ammeter range (0-1250A)A.C, Specifications,-1.Measured scale- A.C R.M.S value 2.3-1/2 digit Seven segment red color 1Inchdisplay 3.CT Ratio 1250/1 4.Opearting frequency of the system,50Hz 5.Size-96X96mm 6.Accuracy,0.5% of fsd 7.Test Voltage, 2KV for 1 Min. 8.A.C Input to meter , 0-1Amp. A.C 9.Operating Temp., 0 Deg. To + 55 Deg.11.Conforms to , I.S.1248/I.E.C 60051(Part 2) 10.Case-white 11.Enclosure ,IP20 & IP50(Back & Front).12.Mounting-Vertical flush mounting,13. Aux supply, 40V-300V AC/DC, 14.Shape,Square 15.Mounting fastens/Clamps ,Easy mountable clamps &Nuts. Standard Make AE/RISHABH/Equivalent | 10 | NO | Arjun Ghosh 473111,NATIONALFERTILIZERS LIMITED VIJAIPUR | 60 |
| 8 | | Digital Panel Ammeter range (0-100A)A.C, Specifications,-1.Measured scale- A.C R.M.S value 2.3-1/2 digit Seven segment red color 1Inchdisplay 3.CT Ratio 100/1 4.Opearting frequency of the system,50Hz 5.Size-96X96mm 6.Accuracy,0.5% of fsd 7.Test Voltage, 2KV for 1 Min. 8.A.C Input to meter , 0-1 Amp. A.C 9.Operating Temp., 0 Deg. To + 55 Deg.10.Conforms to , I.S.1248/I.E.C 60051(Part 2) 11.Enclosure ,IP20 & IP50(Back & Front) 12.Mounting-Vertical flush mounting 13. Aux supply, 40V -300V AC/DC 14.Shape, Square 15.Mounting fastens/Clamps ,Easy mountable clamps &Nuts. Standard Make AE/RISHABH/Equivalent | 5 | NO | Arjun Ghosh 473111,NATIONALFERTILIZERS LIMITED VIJAIPUR | 60 |
| 9 | | Moving coil with rectifier type, analog Ammeter range (0-200/1200Amp)A.C, without C.T Specifications,-1.Measured scale- A.C R.M.S value 2.Movement-Moving coil annular self shielded spring mounted jewel suspension. 3.CT Ratio 200/1 4.Opearting frequency of the system,50Hz 5.Size-96x96mm 6.Scale,Fullscale deflection 240 degree with end suppressed scale 7.Accuracy,1.0% 8.Test Voltage, 2KV for 1 Min. 9.A.C Input to meter , 0-1Amp. A.C 10.Operating Temp., 0 Deg. To + 50 Deg.11.Conforms to , I.S.1248/I.E.C 60051(Part 2) 12.Case-white 13.Housing Material, ABS 14.Glass Face plate, Flat glass ,clear transparent 15.Mounting-Vertical flush mounting 16.Shape,Square, 17.Mounting fastens/Clamps ,Easy mountable clamps &Nuts. Standard Make AE/RISHABH/Equivalent | 10 | NO | Arjun Ghosh 473111,NATIONALFERTILIZERS LIMITED VIJAIPUR | 60 |
| 10 | | Digital Panel Ammeter range (0-2500A)A.C, Specifications,-1.Measured scale- A.C R.M.S value 2.3-1/2 digit Seven segment red color 1Inchdisplay 3.CT Ratio 2500/1 4.Opearting frequency of the system,50Hz 5.Size-96X96mm 6.Accuracy,0.5% of fsd 7.Test Voltage, 2KV for 1 Min. 8.A.C Input to meter , 0-1Amp. A.C 9.Operating Temp.,0 Deg. To + 55 Deg.10.Conforms to , I.S.1248/I.E.C 60051(Part 2)11.Enclosure ,IP20 & IP50(Back & Front).12.Mounting-Vertical flush mounting ,13. Aux supply, 40V-300V AC/DC,14.Shape,Square 15.Mounting fastens/Clamps ,Easy mountable clamps &Nuts. Standard Make AE/RISHABH/Equivalent | 10 | NO | Arjun Ghosh 473111,NATIONALFERTILIZERS LIMITED VIJAIPUR | 60 |