Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹83.5 LAccepted-AOC | ₹83.5 L Quoted ₹86.2 L | 1 | Accepted-AOC Lowest Quoted bidder, hence accepted |
| 2 | 2₹90.6 LRejected-Finance | ₹90.6 L | 2 | Rejected-Finance Second Lowest quoted bidder, hence rejected |
| 3 | 3₹98.7 LRejected-Finance NO 17 NEW CAUVERY NAGAR THANJAVUR 613 001 | THANJAVUR | TAMIL NADU | 613001 | ₹98.7 L | 3 | Rejected-Finance Third Lowest quoted bidder, hence rejected |
| Sl No | Description | Qty | Unit | SRI JAGATHI CONSTRUCTION L3 | B SARAVANAKUMAR L2 | SIVASUBRAMANIAN RAMASAMY L1 |
|---|---|---|---|---|---|---|
| 1.00Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of walls | ||||||
| 1.01 | Dismantling Brick work - under 3m high | 32.13 | M3 | 350 ₹11,245.50 | 320 ₹10,281.60 | 305 ₹9,799.65 |
| 2.00 | Supply and filling in foundation and basement with Gravel in layers of not more than 15cm.thick well rammed watered and compacted with surface vibrator, watered and consolidated etc. complete complying with standard specification and as directed by the departmental officers. | 277.8 | M3 | 1,280 ₹3.6 L | 1,250 ₹3.5 L | 1,230 ₹3.4 L |
| 3.00Brick work in following Cement Mortar using best quality Burnt Clay Brick of size 8 3/4” x 4 1/4” x 2 1/4” with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge. | ||||||
| 3.01In Cement Mortar 1:5 | ||||||
| 3.02 | In Ground Floor | 17.35 | M3 | 7,200 ₹1.2 L | 7,150 ₹1.2 L | 7,100 ₹1.2 L |
| 3.03 | In First Floor | 32.55 | M3 | 7,400 ₹2.4 L | 7,350 ₹2.4 L | 7,300 ₹2.4 L |
| 4.00Brick partition walls of 10.80cm thickness using best quality Burnt Clay Brick of size 8-3/4” x 4-1/4” x 2-1/4” with class designation of 7.5 conforming to IS 1077-1992 in Cement Mortar 1:3 (One Cement and Three CS Sand) using hoop iron reinforcement if found necessary including Cost of Mortar Plasticizer, curing etc. complete complying with standard specification and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) | ||||||
| 4.01 | First floor | 59 | M2 | 1,050 ₹61,950 | 1,000 ₹59,000 | 990 ₹58,410 |
| 5.00 | Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers. | 337.16 | M2 | 380 ₹1.3 L | 350 ₹1.2 L | 310 ₹1.0 L |
Tender Value
₹83.5 L
EMD Value
₹52,000
Closing Date
9 Apr 2026, 12:00 pmClosed
Superintending Engineer
Office of Superintending Engineer, PWD, Buildings C and M Circle, PWD Campus, Tiruvarur-1.
Providing Barricading Arrangements for Strong Room and Counting Hall for 166-Thiruthuraipoondi, 167-Mannargudi, 168-Thiruvarur, 169-Nannilam in Thiru.Vi.Ka. Government Arts College Building at Thiruvarur for Assembly Constituency Election of 2026
2026_PWD_675470_1
60-01/ BCM/TVR/2025-26
Open Tender
Civil Works - Others
30 days
Tiruvarur
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹52,000
13 Apr 2026
2 Apr 2026
9 Apr 2026
2 Apr 2026
9 Apr 2026
2 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of walls | |||||
| 1.01 | Dismantling Brick work - under 3m high | - | M3 | - | - |
| 2Supply and filling in foundation and basement with Gravel in layers of not more than 15cm.thick well rammed watered and compacted with surface vibrator, watered and consolidated etc. complete complying with standard specification and as directed by the departmental officers. | |||||
| 3Brick work in following Cement Mortar using best quality Burnt Clay Brick of size 8 3/4” x 4 1/4” x 2 1/4” with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge. | |||||
| 3.01 | In Cement Mortar 1:5 | - | - | - | - |
| 3.02 | In Ground Floor | - | M3 | - | - |
| 3.03 | In First Floor | - | M3 | - | - |
| 4Brick partition walls of 10.80cm thickness using best quality Burnt Clay Brick of size 8-3/4” x 4-1/4” x 2-1/4” with class designation of 7.5 conforming to IS 1077-1992 in Cement Mortar 1:3 (One Cement and Three CS Sand) using hoop iron reinforcement if found necessary including Cost of Mortar Plasticizer, curing etc. complete complying with standard specification and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) | |||||
| 4.01 | First floor | - | M2 | - | - |
| 5Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers. | |||||
stage.html
html • 0.04 MB
techsummary_811833.pdf
finsummary_811833.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.58 MB
BOQ_811833.xls
BOQ • 0.33 MB
Tiruvarrurelectionworkcondition.pdf
Tender Documents • 1.69 MB
Download all tender documents and submit your bid