| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹24.5 LAccepted-AOC H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | 1 | Accepted-AOC BEING LOWEST | |
| 2 | 2₹28.3 L+₹2.7 L (10.5%)Rejected-Finance | 2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | 3₹30.4 L+₹4.7 L (18.4%)Rejected-Finance H NO 74 6 JUTOGH CANTT SHIMLA HP 171 008 | SHIMLA | HIMACHAL PRADESH | 171008 | 3 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
27 Jul 2022, 6:00 pmClosed
GE 863 EWS
GE 863 EWS C/O 56 APO
REPAIR MAINTENANCE OF EXTERNAL WATER SUPPLY PIPE LINES CONTROL VALVES PUMP MOTORS AND OTHER CONNECTED WORKS AT KARCHAM POARI AND POOH IN THE AREA OF AGE EM WE POOH UNDER GE 863 EWS
2022_MES_528418_2
GE863/EWS-T-09 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
Pooh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 863 EWS
₹48,000
Yes
2 Aug 2022
6 Jul 2022
29 Jul 2022
6 Jul 2022
27 Jul 2022
13 Jul 2022
Amount
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 m in depth in a hard/dense soil for laying underground Pipe/ cables/ errection of steel tubular poles / stay pit etc. complete all as specified and directed.
Returning, filling in incl spreading,levelling watering and well ramming in layer n exc.25 cm each layer, in soil, complete all as specified and directed.
Removing excavated surplus material to a distance n.exc 50 m and depostimg where directed at a level n exc. 1.5 m above the starting point in any type of soil complete all as specified and directed.
Supply and fixing in replacement High density polyethylene pipes (HDPE), 63 mm bore of pressure rating 6 kgf/sqcm fixed complete to walls, ceilings or in floors etc. incl all fittings complete all as specified and directed.
Supply and fixing in replacement High density polyethylene pipes (HDPE), 50 mm bore of pressure rating 6 kgf/sqcm fixed complete to walls, ceilings or in floors etc. incl all fittings complete all as specified and directed.
Supply and fixing in replacement GI Tubing , medium grade , 20 mm bore , laid in trenches/ wall/ceiling/floor/ road etc. complete all as specified & directed. Note: Road cutting shall be measured and paid seperatly under respective items.
Supply and fixing in replacement GI Tubing , medium grade , 25 mm bore , laid in trenches/ wall/ceiling/floor/ road etc. complete all as specified & directed. Note: Road cutting shall be measured and paid seperatly under respective items.
Supply and fixing in replacement GI Tubing , medium grade , 50 mm bore, laid in trenches/ wall/ceiling/floor/ road etc. complete all as specified & directed. Note: Road cutting shall be measured and paid seperatly under respective items.
S&F in replacement of gun metal gate valve (heavy duty) with iron wheel head screwed both ends for iron pipe of 20 mm dia bore complete all as specified & directed.
S&F in replacement of gun metal gate valve (heavy duty) with iron wheel head screwed both ends for iron pipe of 25 mm dia bore complete all as specified & directed.
S&F in replacement of gun metal gate valve (heavy duty) with iron wheel head screwed both ends for iron pipe of 50 mm dia bore complete all as specified & directed.
S&F in replacement Rotational moulded poly-ethylene water storage tanks (cylinderical vertical with closed top) of capacity 2,000 Ltr hoisted and fixed in position complete all as specified & directed. Note: Construction of tank foundation (not less than 450mm height from ground level) in PCC 1:3:6 type B-1, using 20 mm graded stone aggregate incl necessary form work of suitable size and accessories required for connection to tank inlet and outlet is deemed to be included in quoted rate.
M&L for road cutting/Hardstanding/Tile cutting upto 300mm deep and 200mm wide for crossing water pipe line through road including making good the disturbed surface by filling mass concrete complete all as specified and directed. Note: Mass concrete will be measured and paid as sapreartly in respective item.
M&L for Cement concrete in foundations, filling and mass concrete 1:4:8 ,type D2 (40mm graded stone aggregate), complete all as specified and directed.
M&L in replacement Cast Iron Air release valves PN 1.0 with two air outlets/orifice screwed end type, 50mm bore dia and fixing up in iron water supply mains, complete all as specified and directed. Note: Accessories like nipple, socket, flange etc required at site is deemed to be included in quoted rate.
S&F in replacement CI non-return (reflux) valve confirming to PN-1.0 with rubber seal ,screwed end type, 50 mm bore dia and fixing up in iron water supply mains, complete all as specified and directed. Note: Accessories like nipple, socket, flange etc required at site is deemed to be included in quoted rate.
S&F in replacement of chlorine/Chemical dosing system suitable to inject solution upto 30-50LPH, chlorine/Chemical dosing (metering) pump (speed adjustable) simplex diphram type couple with single phase electric motor of capacity 0.5-1HP, 900-1440 RPM as agitator (agitator with Engineer material plastic shaft & impeller ) and FRP tank of 100 Ltr capacity, along with suction discharge tubing, foot valve/ "Y' strainer, anti siphon valve, pressure relief valve etc. complete unit as specified and directed . Note: Old / unserviciable Chlorine / Chemical dosing system shall be deposit in MES store yard by the contractor and shall be taken on charge by the deptt.
Supply and fixing in replacement of DOL starter suitable for monoblock pumpset of capacity 5HP, 3 Phase, 415V, 50 Hz with relay range of 9-14 Amp along with complete wiring, complete all as specified and directed. Note: Fastner (not less than 6 inchs - 4 nos), nut bolt & washer deemed to be included in quoted rates for fixing timer wall/pole.
Supply and fixing in replacement of DOL starter suitable for monoblock pumpset of capacity 10 HP, 3 Phase, 415V, 50 Hz with relay range of 13-21 Amp along with complete wiring, complete all as specified and directed. Note: Fastner (not less than 6 inchs - 4 nos), nut bolt & washer deemed to be included in quoted rates for fixing timer wall/pole.
M&L for opening and rewinding of electric motor 5HP , 50 HZ 400/415 volts of mono block/centrifugal elctric motor of any make and type with super enameled copper winding wire of existing size including bearing bushes and other accessories etc required to make motor functional and testing on load and closing the motor after rewinding including transportation to workshop and back at site complete all as specified and as directed .
M&L for scrubbing, cleaning thoroughly for removing the dirts, sediments, silts etc from the internal surfaces of HDPE storage tanks of capacity upto 500 Ltrs from bottom and wall by using brushes, bleaching powder and other cleaning materials as directed including writing the words " TANK CAPACITY AND DATE OF CLEANING" in capital letters of suitable size on outside visible place of OH tank with synthetic enamel white paint over black back ground complete all as specified and as directed .
M&L for scrubbing, cleaning thoroughly for removing the dirts, sediments, silts etc from the internal surfaces of HDPE storage tanks of capacity 501 to 1000 Ltrs from bottom and wall by using brushes, bleaching powder and other cleaning materials as directed including writing the words " TANK CAPACITY AND DATE OF CLEANING" in capital letters of suitable size on outside visible place of OH tank with synthetic enamel white paint over black back ground complete all as specified and as directed .
M&L for scrubbing, cleaning thoroughly for removing the dirts, sediments, silts etc from the internal surfaces of HDPE storage tanks of capacity 1001 to 2000 Ltrs from bottom and wall by using brushes, bleaching powder and other cleaning materials as directed including writing the words " TANK CAPACITY AND DATE OF CLEANING" in capital letters of suitable size on outside visible place of OH tank with synthetic enamel white paint over black back ground complete all as specified and as directed .
M&L for scrubbing, cleaning thoroughly for removing the dirts, sediments, silts etc from the internal surfaces of HDPE storage tanks of capacity 2001 to 5000 Ltrs from bottom and wall by using brushes, bleaching powder and other cleaning materials as directed including writing the words " TANK CAPACITY AND DATE OF CLEANING" in capital letters of suitable size on outside visible place of OH tank with synthetic enamel white paint over black back ground complete all as specified and as directed .
Material and labour for cleaning of RCC sedimentation tank (each portion of 5500 gallon & of size 7.35x1.75x2.05 Metre -2 nos) of capacity 11000 gallon, draining/washing out complete through wash out pipe, and removing all mud, silt, scales, dirts etc from inside area and cleaning with bleaching powder, iron brush, broom and sand paper etc and marking date of cleaning and capacity of tank with synthetic enamel paint complete all as specified and directed . Note: (I) cleaning of raw water tanks of capacity 850 Gallon - 2 nos is deemed to be included in quoted rate. (ii) Rate quoted are inclusive of Removal of Sand & Gravels of different size from filteration plant & depositing at a distance not exceeding 30 mtrs away and leveling it as directed. (iii) Refilling of Sand & Gravels of different size shall be measured & paid saperatly under respective item.
Material and labour for cleaning of RCC sedimentation tank (each portion of 18000 gallon of size 8.13 x 3.7 x 2.7 metre -2 nos) of capacity 36000 gallon, draining/washing out complete through wash out pipe, and removing all mud, silt, scales, dirts etc from inside area and cleaning with bleaching powder, iron brush, broom and sand paper etc and marking date of cleaning and capacity of tank with synthetic enamel paint complete all as specified and directed . Note: (I) cleaning of raw water tanks of capacity 850 Gallon - 2 nos is deemed to be included in quoted rate. (ii) Rate quoted are inclusive of Removal of Sand & Gravels of different size from filteration plant & depositing at a distance not exceeding 30 mtrs away and leveling it as directed. (iii) Refilling of Sand & Gravels of different size shall be measured & paid saperatly under respective item.
Material and labour for cleaning of RCC sedimentation tank (each portion of 7500 gallon & of size 7.6 x 3.55 x 2.6 metre -2 nos) of capacity 15000 gallon, draining/washing out complete through wash out pipe, and removing all mud, silt, scales, dirts etc from inside area and cleaning with bleaching powder, iron brush, broom and sand paper etc and marking date of cleaning and capacity of tank with synthetic enamel paint complete all as specified and directed . Note: (I) cleaning of raw water tanks of capacity 850 Gallon - 2 nos is deemed to be included in quoted rate. (ii) Rate quoted are inclusive of Removal of Sand & Gravels of different size from filteration plant & depositing at a distance not exceeding 30 mtrs away and leveling it as directed. (iii) Refilling of Sand & Gravels of different size shall be measured & paid saperatly under respective item.
M&L filter media (Gravel) of size 40mm graded coarse stone aggregate (thickness - 400mm = 2 tanks) of filteration tank complete all as specified and directed.
M&L filter media (Gravel) of size 20 mm graded coarse stone aggregate (thickness - 300mm = 2 tanks) of filteration tank complete all as specified and directed.
M&L filter media (Gravel) of size 10/12.5 mm graded coarse aggregate (thickness - 150mm = 2 tanks) of filteration tank complete all as specified and directed.
S&F uncharged and non cogulant sand media and marble stone aggregate of 5mm graded (12 cum/12000 Kg) (thickness - 100mm - 2 tanks ) in white colour suitable for water filteration bed including removing of old silica sand from the site and depositing away from tank complete all as specified and directed.
Supply Only Chlorine Test Kit with coloured sample complete all Testing fitments & OT Solution in Rexine finish Box complete all as specified and directed.
Supply only for OT solution for chlorine test in 500 mililitre bottle complete all as specified and directed.
M&L for construction of Valve pit chamber 90 cmx90cm (inner dimension) and 90 cm deep , from the top of MS angle iron frame of 40x40x6 mm, fixed on 75 mm thick PCC Base/coping in (1:2:4) type B-I using 20 mm graded stone aggregate, top cover shall be of 3 mm thick MS Sheet with locking arrangement of pad lock of 50mm size including PCC block masonary in (1:3:6) type B-I using 20 mm graded stone aggregate set in cement mortar 1:4 including 15 mm thick plaster in cement mortar 1:4 (internally and externally) and necessray excavation, earth work in any type of soil including necessary form work and 150 mm thick PCC 1:4:8 , type D-2 , using 40mm graded stone aggregates as in floor including dismentaling of old valve pit complete all as specified and directed. Note: Quoted rates shall deemed to be included for following provisions:- (i) Exacavation and earth work. (ii) steel surfacesc shall be painted with two coats of synthetic enamal paint over a coat of red oxide primer. (iii) Exposed surfaces of valve pit shall be painted with two coats of cement base paint incl preperation of surfaces.
S & F in repair Sluice Valve of size 100 mm bore class PN 1.0 GI with iron wheel head , screwed both ends for GI tubing medium grade complete all as specified and directed.
Supply, Laying and testing in replacement, 3 layer PP-R polypropylene random copolymer concealed pipes, SDR 7.4 (PN-16) & SDR 11 UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PP-R Plain & brass threaded polypropylene random fitting of size 20mm (outer diameter of pipe) complete all as specified and directed. Note:- Excavation and earth wrok shall be measured and paid separately.
Supply, Laying and testing in replacement, 3 layer PP-R polypropylene random copolymer concealed pipes, SDR 7.4 (PN-16) & SDR 11 UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PP-R Plain & brass threaded polypropylene random fitting of size 25mm (outer diameter of pipe) complete all as specified and directed. Note:- Excavation and earth wrok shall be measured and paid separately.
Supply, Laying and testing in replacement, 3 layer PP-R polypropylene random copolymer concealed pipes, SDR 7.4 (PN-16) & SDR 11 UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PP-R Plain & brass threaded polypropylene random fitting of size 40mm (outer diameter of pipe) complete all as specified and directed. Note:- Excavation and earth wrok shall be measured and paid separately.
Supply and fixing lagging to pipes used in water supply for plumbing, all round with lagging, closed cell elastomeric nitrile rubber insulation with pipe section of density 60+20% Kg/cum, suitable for PPR pipe of size 20mm dia complete all as specified and directed.
Supply and fixing lagging to pipes used in water supply for plumbing all round with lagging closed cell elastomeric nitrile rubber insulation with pipe section of density 60+20% Kg/cum, suitable for PPR pipe of size 25mm dia complete all as specified and directed.
Supply and fixing lagging to pipes used in water supply for plumbing all round with lagging closed cell elastomeric nitrile rubber insulation with pipe section of density 60+20% Kg/cum, suitable for PPR pipe of size 40mm dia complete all as specified and directed.
M & L for providing aluminium cladding over insulation of PPR pipe of size 20mm dia with aluminium sheet having thickness 0.2mm all as specified and directed
M & L for providing aluminium cladding over insulation of PPR pipe of size 25mm dia with aluminium sheet having thickness 0.2mm all as specified and directed
M & L for providing aluminium cladding over insulation of PPR pipe of size 40mm dia with aluminium sheet having thickness 0.2mm all as specified and directed
Taking down old unserviceable gun metal gate valve and s&f PP-R Gate valves (brass insert) as per requirement of the site of size 20mm dia bore (outer dia of pipe in mm) compete all as specified and directed.
Taking down old unserviceable gun metal gate valve and s&f PP-R Gate valves (brass insert) as per requirement of the site of size 25mm dia bore (outer dia of pipe in mm) compete all as specified and directed.
Taking down old unserviceable gun metal gate valve and s&f PP-R Gate valves (brass insert) as per requirement of the site of size 32mm dia bore (outer dia of pipe in mm) compete all as specified and directed.
Taking down old unserviceable gun metal gate valve and s&f PP-R Gate valves (brass insert) as per requirement of the site of size 40mm dia bore (outer dia of pipe in mm) compete all as specified and directed.
Supply and fixing in replacement Ball brass valves, high pressure,with polythene float and flynut complete,screwed for iron pipe or brass ferrule and fixed, 20 mm bore dia with rod complete all as specified and directed
Supply and fixing in replacement Ball brass valves, high pressure,with polythene float and flynut complete,screwed for iron pipe or brass ferrule and fixed, 25 mm bore dia with rod complete all as specified and directed
S & F in replacement 1000 ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), 3 layered, with screwable lid, duly provided with necessary fittings/fixtures for connecting inlet, outlet, washout and overflow pipes, noisted incl ball brass valve, high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule 20 mm bore and fixed in position complete all as specified and directed.
S & F in replacement 500 ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), 3 layered, with screwable lid, duly provided with necessary fittings/fixtures for connecting inlet, outlet, washout and overflow pipes, noisted incl ball brass valve, high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule 20 mm bore and fixed in position complete all as specified and directed.
S&F in replacement PUF insulated, cylndrical tank, of capacity 500 Ltr, Vertical type, double layer duly filled with puf insulation of superior quality to resist in temp -30 to +35 degree centigrade alongwith hinged top lid of same material with locking arrangement and hoisted on platform complete with making pipeline connection with the following specification :- (a) Inner tank will be double layered HDPE food grade material. (b) Outer 4mm thick FRP jointless casing of tank. (c) Thickness of PUF insulation shall be 75mm. (d) Minimum density of PUF insulation shall be 44 kg per/cum +/- 10%.
S&F in replacement PUF insulated, cylndrical tank, of capacity 1000 Ltr, Vertical type, double layer duly filled with puf insulation of superior quality to resist in temp -30 to +35 degree centigrade alongwith hinged top lid of same material with locking arrangement and hoisted on platform complete with making pipeline connection with the following specification :- (a) Inner tank will be double layered HDPE food grade material. (b) Outer 4mm thick FRP jointless casing of tank. (c) Thickness of PUF insulation shall be 75mm. (d) Minimum density of PUF insulation shall be 44 kg per/cum +/- 10%.
Net Contract Sum will be after deducting Sch Of Credit of Rs. 1,11,186.50
JAMDAGNI ENGG WORKS
M/S SHIV NATH ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .