Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | ₹1.3 Cr | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹1.3 Cr+₹3.0 L (2.33%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹1.3 Cr+₹3.0 L (2.33%) | L2 | Rejected-Finance Higher Bidder |
| 3 | L3₹1.3 Cr+₹3.3 L (2.55%)Rejected-Finance | ₹1.3 Cr+₹3.3 L (2.55%) | L3 | Rejected-Finance Higher Bidder |
| 4 | L4₹1.4 Cr+₹4.7 L (3.63%)Rejected-Finance COLABA MUMBAI | ₹1.4 Cr+₹4.7 L (3.63%) | L4 | Rejected-Finance Higher Bidder |
| 5 | L5₹1.4 Cr+₹8.4 L (6.43%)Rejected-Finance PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | ₹1.4 Cr+₹8.4 L (6.43%) | L5 | Rejected-Finance Higher Bidder |
Tender Value
₹1.3 Cr
EMD Value
₹2.1 L
Closing Date
1 Nov 2022, 6:00 pmClosed
SH A K SINGH SE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
REPAIR MAINTENANCE INCLUDING MANNING AND OPERATION OF AC PLANTS AT HTL WHJBC PMS IGLOO DBM MTP PLANTS AND REPAIR MAINTENANCE OF DUCT TOWER ACS INCLUDING FIRE ALARM SYSTEM UNDER GE SB KARWAR
2022_MES_550385_2
85595/E8
Open Tender
Civil Works
Item Rate
330 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹1,000
Yes
GE (SB) KARWAR
₹2.1 L
Yes
12 Nov 2022
11 Oct 2022
3 Nov 2022
11 Oct 2022
1 Nov 2022
18 Oct 2022
Amount
SCH 'A' PART-I (MAINTENANCE OF AC PLANTS)
M&L dismantling electric motor of any make, 3 phase 415V of following capacity, opening the motor for rewinding using super enamelled copper wire of suitable gauge to match with the existing winding as per manufacturer design including varnishing & drying and re-assembling the motor, connecting with proper alignment and testing complete including transporting to workshop for rewinding complete all as specified and as directed.
(e) 1 to 3 HP
M & L for Servicing of water pump split casing type set by removing & dismantling pump and connected pipes & electric connections etc and replacing of unserviceable parts with new gland packing set Gun metal bushes, bearing, water seal packing complete cleaning of impeller greasing etc reassembling and refixing in original position complete with packing and necessary nut & belt etc including testing for smooth functioning etc of following capacity all as specified and as directed.
Supply & Fix in repairs scroll compressor 13 TR from the unit after disconnecting electrical wiring & piping connection nuts & bolts etc supply & install of new scroll compressor 13 TR capacity and connecting pipe line for existing piping brazing & electric connection etc. at IGLOO,DBM,PMS complete all as specified and as directed.
All as per item No. 3 but for 5.5 TR
M & L for disconnecting condenser for descaling & Plugging them & providing of 15 mm tee out let for local circulation of mild acid solution in the condenser (separate container and small pump set to circulate diluted acid solution to be used) PH value of solution to be circulated & to be kept 4 and checking frequently i.e. every one hour during the operation Scalgun WS solution to be used for descaling purpose after 2 to 3 hours of cleaning if ph value remains less than 7 flush with fresh water mixed with sodium carbonate tubes and cleaning with nylon brush after closing the end covers, circulating diluted acid solution as specified above & PH value to be maintained as above & flushing the same with fresh water including recharging of stored refrigerant up to required pressure complete all as specified and as directed for the following :
(a) 3x 120 TR at MTP
(b) 3x26 TR at IGLOO
(c) 3x30 TR at PMS
(d) 2x30 TR at WHJBC
(e) 3x39 TR at DBM
Pumping down the plant to preserve the existing refrigerant gas & leak testing of 26/30/39TR chiller package unit by charging of Nitrogen gas in to entire plant & monitoring for 24 Hrs to find the leakages, rectification of leak by brazing and replacement of necessary gasket packing as wherever required including copper tubes of suitable size vacumizing of the plant by vaccum pump and keeping 24 hrs for testing including rectification of leakages if any finally recharging of existing refrigerant gas to the plant & topping up of refrigerant if required to maintain the standard pressure complete testing of the plant for smooth functioning at IGLOO , DBM ,PMS , WHJBC complete all as specified and as directed
All as per Item No.6 but for 11 TR chiller unit of Package AC plant at HTL complete all as specified and as directed.
Supply & charge refrigerant (R - 22) gas as per requirement complete all as specified and as directed
Topping up / Replacement of compressor oil with new compressor oil complete all as specified and as directed
Supply & Fix in repair for the following Items complete all as specified and as directed.
(a) Water Flow Switch complete all as directed .
(b) Moisture liquid indicators.
(c) Single phase preventor for compressor /Motor for SM 101 GIC
(d) Strip type 3 KW Heaters
(e) Strip type 2.0 KW Heaters
(f) Pressure gauge 0-300 PSI .
(g) Pressure gauge 0-150 PSI
(h) Crank case heater 250 W suitable for 39/30/26 TR CHW plant
(j) Filter drier core for 120/39/30/26 TR Central AC Plant
(k) LP/HP cut out switch for 39/30/26 TR Central AC Plant
(l ) V belt for Cooling tower . Make : Fenner/Dunlop
(m) Float Valve for 25 mm
(n) Cooling tower fins of size 4'x6'
(o) AHU belt
M&L for applying one coat of synthetic enamel paint as per colour code with spray machine on surfaces of 3X120/3x30/3x26/3x39 TR central AC plant comprising compressor motor, Pump, water pipe lines etc by filling cavities if any with filler including preparation of surfaces & indication markings at PMS/WHJBC/IGLOO/DBM/MTP complete all as specified and as directed
Taking down motor, blower fan assembly from cooling Tower, removing unserviceable fins , & providing new PVC fins of size 4"x6" ,after cleaning of Louvers, drift eleminators fill surface by moderate pressure water nozzle to remove all surface impurities incl removal of rust/scale, scrapping down the hard water deposited from bottom tray with chemical and preparing the surfaces and painting with one coat of anticorrosive paint to match with existing colour, servicing of fan and motor assembly including removal of dust, oil, scale of motor body and replacing of unserviceable nozzle,bearings , painting with anti corrosive paint, draining and filling of bearing housing with new SAE 20 grade mineral oil, greasing of bearing with IOCL mobilux etc , & reassembling complete of following cooling towers complete all as specified and as directed
(a) FRP Cooling tower capacity 450 USGPM AT MTP
(b) 101 USGPM at IGLOO
(c) 141 USGPM at DBM
(d) 75 USGPM at PMS/WHJBC
Note: (a)Defective parts of plants will be replaced and measured under respective item of this schedule. (b) Fins, bearing , float valve reqd for replacement will be measured under under respective item of this schedule.
Supply & fixing in repair Nitrile insulation layers of size 25 mm thickness sticking on the chiller surface by using approved adhesive and ceiling joint by weather proof tape after removing unserviceable nitrile insulation from the chiller & cleaning complete all as specified and as directed.
Supply and fixing in repair fine filters 5 Microns as per exisiting make complete all as specified and as directed.
Supply and fixing in repair pre filters 10 Micron as per exisiting make complete all as specified and as directed.
Supply & Fix in repairs MS pipe heavy grade 80 mm dia including removing of unserviceable MS pipe medium grade of 80 mm dia complete all as specified and as directed
(b) Supply & Fix in repairs MS pipe heavy grade 100 mm dia including removing of unserviceable MS pipe medium grade of 100 mm dia complete all as specified and as directed
(c) Supply & Fix in repairs MS pipe heavy grade 40 mm dia including removing of unserviceable MS pipe medium grade of 40 mm dia complete all as specified and as directed
(d) Supply & Fix in repairs MS pipe heavy grade 50 mm dia including removing of unserviceable MS pipe medium grade of 50 mm dia complete all as specified and as directed
(e) Supply & Fix in repairs butter fly valve 50 mm dia including removing of unserviceable butter fly valve of size 40/50 mm dia complete all as specified and as directed
(f) Supply & Fix in repairs butter fly valve 100 mm dia including removing of unserviceable butter fly valve of size 100 mm dia complete all as specified and as directed
M&L dismantling electric motor of any make, 3 phase 415V of 120 TR capacity, opening the motor for rewinding using super enamelled copper wire of suitable gauge to match with the existing winding as per manufacturer design including varnishing & drying and re-assembling the motor, connecting with proper alignment and testing complete including transporting to workshop for rewinding complete all as specified and as directed
Labour only for overhauling Compressor 120 TR of make "YOKE" , reassambling with new spares, reinstalling, relighting, testing on load to recover the existing gas, flushing the system and leakage testing , presure testing & gas charging etc complete all as specified and as directed.
Note :- (a) Spares require will be measured and paid seperately. (b) Labour for fixing the spares is included in the rate quoted for above item.
Supply only following spares required for Compressor complete all as specified and as directed
(a) Suction retaining plate
(b) Suction Reed
(c ) DV assembly
(d) Suction spring
(e) Unloader Spring
(f) Gasket set Non absestor
(g) Connecting rod
(h) Piston
(j) Piston lock ring
(k) Piston ring set
(l) Piston pin
(m) Cylinder liner
(n) Main bearing
(o) Main thrust ring
(p) Unloader pin lock
(q) Oil pressure regulating valve
(r ) Oil pump assembly
(s) Oil filter
(t) Liner Aluminium sims
M & L Expansion valve of AC plant capacity 26/30/39/120 TR including taking down unserviceable valve complete all as specified and as directed.
All as per Item No.26 but for 7.5 TR
PART-II :ROUTINE MAINT DUCT/ TOWER AC INCL COLD & COOL ROOM
M&L for rectification of defects and making functional duct / floor mounted AC and cold room/cool room of any capacity incl rectification of minor defects such as tripping of MCBs, replacement of MCBs wherever necessary, rectifying loose electrical connections, making fresh connections in electric panel / connector / contactor/capacitor/relay etc, making functional of defective plug / cap etc, arresting condensate water leakage, checking function of compressor of any capacity etc complete all as specified and as directed. Note :- (i) Unit rate quoted shall include for maintaining proper record and obtain the signature of concerned user unit. (ii) Unit rate quoted shall include for sundry items / materials as required. (iii) MCB TPN 32/40 Amps will be measured and paid separately. (iv) Spare parts required will be measured and paid separately.
M&L for periodical maintainance of duct AC of 5 Ton capacity including cleaning of overhead ceiling supported indoor unit complete, duct system, blower, outdoor unit, wiring system, cool air vent, checking function of fire damper, cleaing including, oiling / greasing of movable parts of indoor unit such as motor bearing etc, fresh electrical connections, checking insulation of wiring etc complete, all as specified and as directed.
All as per item No 29 above but 7.5 Ton duct AC.
All as per item No 29 above but for 3 Ton Tower AC
Labour only for leak testing including all allied works such as vaccumising the complete system, soap leak test, nitrogen gas pressure test, replacement of copper filters, capillary, copper tubing of suitable size and required length, flux, flare nut, dead plug, dead cap, brazing etc including necessary welding work, testing and commissioning upto satisfactory performance for the following :-
(a) Refrigeration circuit of floor mounted Tower AC of capacity 3 Ton .
(b) Refrigeration circuit of Duct AC of capacity 5 Ton .
(c) 3 Nos of Refrigeration circuit of 2.5 Ton each for Duct AC of capacity 7.5 Ton. Note :- Qty of gas will be measured and paid separately.
S&F in repairs reciprocationg compressor 3 phase 415 V, 2.5 Ton capacity Model No CR 36 K 6TF 6101- 01 No of existing make suitable for duct AC factory tested including taking out old compressor, pumping down refrigerant, bracing and flaring, topping up of refrigerant (labour only) connecting, testing and commissioning the compressor complete all as specified and as directed
All as per item No 33 but for 3 Ton capacity for floor mounted AC and Tower AC complete all as specified and as directed.
All as per item No 33 but 5 Ton capacity for duct AC AG5560. complete all as specified and as directed.
S&F in repairs propeller type fan / blower motor, single end shaft, single phase, 240 volts, 1/4 HP metallic body/PVC body for outdoor unit of duct / floor mounted AC suitable for Blue Star make all as specified and directed. complete all as specified and as directed
All as per item No 36 but 1/2 HP for 5 TR duct AC complete all as specified and as directed
S&F in repairs fan / blower centifugal type motor, double end shaft, single phase, 240 volts, 3/4 HP metalic body for indoor unit of duct AC suitable for Blue Star make complete all as specified and as directed
S&F in repairs fan blade assembly for outdoor unit suitable for Blue Star make following capacities complete all as specified and as directed
(a) 3.0 TR Capacity of floor mounted AC /tower AC
(b) 5 TR capacity of duct AC
(c) 7.5 TR capacity of duct AC
M&L for taking down unserviceable fan blower motor of 1/4 HP capacity from outdoor unit of duct / floor mounted AC and rewinding motor, varnishing, drying etc, replacement of bush, assembly etc suitable for Blue Star make and fixing it back complete all as specified and as directed.
M&L for taking down unserviceable fan blower motor of 1/2 HP capacity from outdoor unit of duct / floor mounted AC and rewinding motor, varnishing, drying etc, replacement of bush, assembly etc suitable for Blue Star make and fixing it back complet all as specified and as directed.
M&L for taking down unserviceable fan blower motor of 3/4 HP capacity from outdoor unit of duct / tower AC by removing ceiling boards, disconnecting electrical connection, rewinding motor varnishing, drying etc, replacement of bush, assembly etc suitable for Blue Star make and fixing it back complet all as specified and as directed.
S&F in repairs 12 way wiring connector terminal for duct AC / tower AC complete all as specified and as directed
S&F in repairs PVC air filter for floor mounted AC 3 Ton capacity complete all as specified and as directed
S&F in repairs pendent control assembly with cord and PC circuit Model 050D suitable for Blue Star make duct AC of 5/ 7.5 Ton capacity complete all as specified and as directed
S&F in repairs overload relay for 5 Ton compressor of Duct AC complete all as specified and as directed
S&F in repair overload relay for 2.5/3 Ton compressor of Duct AC complete all as specified and as directed
S&F in repairs flexible cord, 3 core, copper conductor 2.5 Sqmm complete all as specified and as directed
S&F in repairs single phase preventer cum controller for operation of floor mounted AC of 3 Ton capacity complete all as specified and as directed
S&F in repairs including brazing of copper tube size 5/8 suitable for duct / floor mounted Acs complete all as specified and as directed.
S&F in repair including brazing of copper tube size 3/8 suitable for duct / floor mounted Acs complete all as specified and as directed
S&F in repair copper tube insulation with heatlon or Superlon insulation material complete all as specified and as directed
Supply only 3 phase contactor 3 TF 3101-08, 400 V suitable for duct AC / floor mounted AC complete all as specified and as directed
Supply & fix in repairs capacitor of 10-36 mfd, plastic body complete all as specified and as directed
Taking out carefullly old Old unserviceable cooling coil condensor of 7.5 TR duct AC ( outdoor unit) and supply and fixing new cooling coil condensor of outdoor unit of 7.5 TR duct AC and make functional including testing complete all as specified and as directed
Supply and fixing in repair MCB TPN 32 to 40 Amps complete all as specified and as directed
Supply and fixing in repair remote control unit for 5 TR , 7.5 TR duct AC and 3TR floor mounted AC, complete all as specified and as directed
M&L for rectification of defects and making functional cold room,cool room of any capacity incl rectification of minor defect such as tripping of MCBs, replacement of MCBs labour only wherever necessary, rectifying loose electrical connections, making fresh connections in electric panel / connectorr etc, making functional of defective drain pipe blockage/leakage etc, checking of functionality of compressor of any capacity etc complete all as specified and as directed. Note :- (i) Unit rate quoted shall include for maintaining proper record and obtain the signature of concerned user unit. (ii) Unit rate quoted shall include for sundry items / materials as required.
Cool room with capacity 4 ton reciprocating compressor
Cold room with capacity 9 ton reciprocating compressor
Supply only R-134 A refrigerant gas in sealed container.
Supply only R-404(a) refrigerant gas in sealed container.
Labour only for gas charging with required quantity with R-134 a and R- 404 arefrigerant gas including all allied works such as vaccumising the complete system, soap leak test, nitrogen gas pressure test, replacement of copper filters, capillary, copper tubing of suitable size and required length, flux, flare nut, dead plug, dead cap, brazing etc including necessary welding work, testing and commissioning upto satisfactory performance for the following complete all as specified and as directed Note :- Qty of gas will be measured and paid separately.
Refrigeration circuit of cool room of capacity 4 Ton.
Refrigeration circuit of cold room of capacity 9 Ton.
S&F in repairs reciporcationg /rotary compressor 3 phase 415 V, 4 TON capacity Model No MT -50 of make RINAC / suitable for temperature 4 Deg Cen with ref 134 a factory tested including taking out old compressor, pumping down refrigerant, bracing and flaring, topping up of refrigerant (labour only) connecting, testing and commissioning the compressor complete all as specified and as directed
S&F in repairs open type compressor 3 phase 415 V, 9 Ton capacity Model No MT 4 CC - 6.2 Y (BITZER) of make RINAC / suitable for temperature mines 10 deg Cenwith ref 404 a factory tested including taking out old compressor, pumping down refrigerant, bracing and flaring, topping up of refrigerant (labour only) connecting, testing and commissioning the compressor complete all as specified and as directed
S&F in repair as per existing new fan / blower motor, single end shaft, single phase, 240 volts, 2 HP metallic body including fan blade assembly suitable for 9 TR and 4 TR make Alstom/Marthom for outdoor unit of floor mounted AC complete all as specified and as directed
S&F in repair single phase preventer cum controller for operation of floor mounted AC of 4 and 9 Ton capacity.complete all as specified and as directed.
S&F in repair HP/LP cut out for floor mounted AC of 4 and 9 Ton capacity complete all as specified and as directed
Supply and fixed in repairs expansion valves thermostatical type for cold storage of capacity 9 ton compressor complete all as specified and as directed
Supply and fixed in repairs expansion valves thermostatical type for cold storage of capacity 4 ton compressor complete all as specified and as directed
Supply and fixed in repairs filter drier model DG -304 suitable for refrigerant 404 (a) for cold storage of capacity 9 ton compressor complete all as specified and as directed
Supply and fixed in repairs filter drier for cool room suitable for refrigerant 134 (a) of capacity 4 ton compressor complete all as specified and as directed
S&F 3 phase Contactor Make : ABB Model No ( A-16-A-30-10-240Volt) suitable for 9TR compressor of Cold room complete all as specified and as directed
S&F 3 phase Contactor Make : ABB Model No ( A-9-30-10-240 Volt ) suitable for 9TR compressor of Cold room complete all as specified and as directed
S&F 3 phase Contactor Make : ABB Model No ( B-25-30-10-240 Volt ) Volt suitable for 9TR compressor of Cold room complete all as specified and as directed
S&F in repair 8 Pin Pla relay suitable for 4TR and 9 TR compressor of Cold room & Cool room complete all as specified and as directed
S&F in repair 3 phase Contactor Make : ABB Model No ( B-9-30-10-240V) suitable for 4TR compressor of Cool room complete all as specified and as directed
S&F in repair 3 phase Contactor Make : ABB Model No ( MNX-18-240) suitable for 4TR compressor of Cool room complete all as specified and as directed
Supply and fixing in repairs sub zero suitable for 4 TR and 9TR compressor complete all as specified and as directed
Supply and fixed in repairs overload relay for capacity 9 ton and 4 Ton compressor complete all as specified and as directed
PART-III :ROUTINE MAINT OF FIRE ALARM SYSTEM
Supply & Fix in repair Manual Call Point (MCP) complete all as specified and as directed
Supply & Fix in repair Glass break MCPcomplete all as specified and as directed
Supply & Fix in repair Addresable thermal detector with flash scan complete all as specified and as directed
Supply & Fix in repair Addresable Relay module with flash scan provides two form-C dry contacts that switch together complete all as specified and as directed
Supply & Fix in repair Addresable control module with flash scan configured for one class A or Class B NAC complete all as specified and as directed
Supply & Fix in repair Addresable mini monitor module with flash scan supervises either a class A or class B circuit of N.D. dry-contact input devices complete all as specified and as directed
Supply & Fix in repair Hooter cum strobe system sensor complete all as specified and as directed
Supply & Fix in repair UV detector complete all as specified and as directed
Supply & Fix in repairs Adressable duct detector complete all as specified and as directed
Supply & Fixing in repair of Network Announciator Panel complete all as specified and as directed
Supply & Fixing in repair of OFC Network card complete all as specified and as directed
Labour only for Non Comprehensive Routine maintenance checkup of Fire alarm system's error and alarms, necessary inspection of the Fire alarm system and take necessary corrected actions,resolve any issues regarding the system and take corrective actions for the problems , check connectivity and communication at all terminations,check all power sources and outlets used in the system complete for 12 Nos panels of Fire alarm system by authorised service engineer of OEM and furnish the report complete all as specified and as directed
Supply & Fix in repairs lead acid type battery of 12 Volts 7 AH capacity complete all as specified and as directed
PART-IV :MANNING AND OPERATION
Manning and operation of package type AC plant at HTL of capacity of 11 ton-02 Nos. ( 1 W ,1 S) Make : Blue Star, Model DPA-1052 S running daily 24 hrs. in 3 shifts for smooth functioning of entire system and to maintain specific temperature as directed complete. AC plants consists of the following accessories:- a) Package type Air conditioning Plant sealed compressor condenser Model DPA 1052-02 Nos. (1 W,1S) b) Electric control panel cubical type main switches,, starter voltmeter, ammeter contractors -01Set. c) Control devices such as expansive valve thermostat solenoid valve HP/ LP/CP cut outs with panel board installed gauges-01 Set. d) Sealed AHU with cooling coil and blower motor-02Set. e) Ducting for supply air with grills diffusers dampers per and re heater etc.-01Set.
Manning & operation of central AC plant with package chiller condensing unit complete of 3 Nos. 26 Ton (Make :-BLUE STAR , Model No. LCWS2-026 at IGLOO complete with cooling tower, AHU & other accessories each for 24 hrs 3 shifts around the clock run daily a) Water cooled package chiller unit model LCWS2-026 -03Nos. b) Chiller water pump motor Model ND-112 M capacity 5 hp, Make - Crompton Greaves -03Nos c) Chiller water pump set Model 2U1 capacity 83 USGPM at 25 Mtr head , Make Becon Weir Ltd -03Nos d) Condeser water pump set Model 2U1 capacity 83 USGPM at 25 Mtr head , Make Becon Weir Ltd -03Nos e) Condeser water pump motor Model ND-112M capacity 5 hp, Make - Crompton Greaves -03Nos
f) Air handling unit model ESHW06-220 of capacity 22277 cmh with blower motor, cooling coil, heater bank, humidity and temperature controller, electric panel complete -02 No. Make - Blue Star g) FRP Cooling tower capacity 101 USGPM , Model No SM2/6C/1.5 with CT fan-03No. Make Mihir Engr Ltd h) Electrical control panel cubical type floor mounted with maint switch MCB's voltmeter , Ammeter, Starter Condenser etc. complete-01Set.
j) Control devices such as expansive valve thermostat solenoid valve HP/ LP/CP cut outs with panel board installed gauges-01 Set. k) Digit type thermometer-01 Set l) Air supply duct with grill diffusers dampers and heater etc.complete-01 Set. m) Condenser piping MS 100/80/50mm dia with valves pressure gauge temperature gauge complete -1Set.
Manning & operation of central AC plant with package chiller condensing unit complete of 3 Nos. 39 Ton (Make :-BLUE STAR , Model No. LCWS3-039 at DBM complete with cooling tower, AHU & other accessories each for 24 hrs 3 shifts around the clock run daily
a) Water cooled package chiller unit model LCWS3-039 -03Nos.
b) Chiller water pump motor Model ND-112 M capacity 5 HP, Make - Crompton Greaves -03Nos
c) Chiller water pump set Model 2U1 capacity 141 USGPM at 25 Mtr head , Make Becon Weir Ltd -03Nos
d) Condeser water pump set Model BWC 50/80 capacity 141 USGPM at 25 Mtr head , Make Becon Weir Ltd -03Nos
e) Condeser water pump motor Model ND-132S capacity 7.5 HP , Make - Crompton Greaves -03Nos
f) Air handling unit model ESHW06-270 of capacity 29549 cmh with blower motor, cooling coil, heater bank, humidity and temperature controller, electric panel complete -02 No. Make - Blue Star
g) FRP Cooling tower capacity 141 USGPM ,Model No SM2/7.5C/2 with CT fan-03No. Make Mihir Engr Ltd-03 Nos
h) Electrical control panel cubical type floor mounted with maint switch MCB's voltmeter , Ammeter, Starter Condenser etc. complete-01Set.
j) Control devices such as expansive valve thermostat solenoid valve HP/ LP/CP cut outs with panel board installed gauges-01 Set.
k) Digit type thermometer-01 Set
l) Air supply duct with grill diffusers dampers and heater etc.complete-01 Set.
m) Condenser piping MS 100/80/50mm dia with valves pressure gauge temperature gauge complete -1Set.
Manning & operation of central AC plant DX type condensing unit complete of 3 Nos. 30Ton (Make :-BLUE STAR , Model No. WCUS2-030 at PMS building, MTP complete with cooling tower AHU & other accessories each for 24 hrs 3 shifts around the clock run daily
a) Water cooled DX unit model WCUS2-030 -03Nos.
b) Condeser water pump set Model 2U1 capacity 75 USGPM at 25 Mtr head , Make -Becon Weir Ltd -03Nos
c) Condeser water pump motor Model ND-112 M capacity 5 HP, Make - Crompton Greaves -03Nos
d) Air handling unit with blower motor, heater bank, cooling coil, electric control panel complete installed in AHU room -01 No. Make - Blue Star Model ESHX6-160 of 19440 cmh
e) FRP Cooling tower capacity 75 USGPM ,Model No SM1/9B/1.5 with CT fan-03No. Make Mihir Engr Ltd-03 Nos
f) Electrical control panel cubical type floor mounted with maint switch MCB's voltmeter , Ammeter, Starter Condenser etc. complete-01Set.
g) Control devices such as expansive valve thermostat solenoid valve HP/ LP/CP cut outs with panel board installed gauges-01 Set.
h) Digit type thermometer-01 Set
j) Air supply duct with grill diffusers dampers and heater etc.complete-01 Set.
k) Condenser piping MS 100/80/50mm dia with valves pressure gauge temperature gauge complete -1Set.
Manning & operation of central AC plant DX type condensing unit complete of 2 Nos. 30Ton (Make :-BLUE STAR , Model No. WCUS2-030 at WHJBC building, complete with cooling tower AHU & other accessories each for 24 hrs 3 shifts around the clock run daily
a) Water cooled DX unit model WCUS2-030 -02 Nos.
b) Condeser water pump set Model 2U1 capacity 75 USGPM at 25 Mtr head , Make -Becon Weir Ltd -02 Nos
c) Condeser water pump motor Model ND-112 M capacity 5 HP, Make - Crompton Greaves -02 Nos
d) Air handling unit with blower motor, heater bank, cooling coil, electric control panel complete installed in AHU room -01 No. Make - Blue Star Model ESHX4-120 of 14076 cmh
e) FRP Cooling tower capacity 75 USGPM ,Model No SM1/9B/1.5 with CT fan-03No. Make Mihir Engr Ltd-03 Nos
f) Electrical control panel cubical type floor mounted with maint switch MCB's voltmeter , Ammeter, Starter Condenser etc. complete-01Set.
g) Control devices such as expansive valve thermostat solenoid valve HP/ LP/CP cut outs with panel board installed gauges-01 Set.
h) Digit type thermometer-01 Set
j) Air supply duct with grill diffusers dampers and heater etc.complete-01 Set.
k) Condenser piping MS 100/80/50mm dia with valves pressure gauge temperature gauge complete -1Set.
Manning & Opeartion of Central AC Plant with package chiller condensing unit complete of 02 Nos working & 01 No Stand by, Each 120 Ton Capacity (Make :-BLUE STAR, Model No. LCWR 1-120 at MTP storages AC Plant complete with cooling tower, AHU & other accessories in 3 shifts as per timings decided by Engineer in charge for efficient and continuous running / operation of central AC Plant and its electrical panel board with other installation / equipments as mentioned below:-
(a) Water cooled package chiller unit model LCWR 1-120 - 03 Nos
(b) Chiller water pump motor model ND-160 M capacity 15 HP,Make- Crompton Greaves - 03 Nos
(c) Chiller water pump set Model BWC 80/100 capacity 360 USGPM at 30 Mtr head,Make-Beacon Weir -03 Nos
(d) Condenser water pump set Model BWC 80/100 capacity 450 USGPM at 25 Mtr head,Make-Beacon Weir-03 Nos
(e) Condenser water pump motor Model ND-160 L capacity 15 HP,Make- Crompton Greaves - 03 Nos
(f) Air handling unit model ESHW4-350 of capacity 36396 cmh with blower motor, cooling coil, heater bank, humidity and temperature controller, electric panel complete-04 Nos. Make- Blue Star
(g) FRP Cooling tower capacity 450 USGPM, Model AQ 3870 with CT fan-03 Nos Make- Paharpur
(h) Electrical control panel cubical type floor mounted with maint switch MCBs volmeter, Ammeter, Starter Condenser etc. complete-01 set
(j) Control devices such as expansive valve thermostat solenoid valve HP/LP/CP cut outs with panel board installed gauges-01 set.
(k) Digit type thermometer - 01 set
(l)Air supply duct with grill diffusers, dampers and heater etc complete - 04 sets
(m) Condenser piping MS 100/80/50 mm dia with valves pressure gauge, temperature gauge complete -01 set.
Notes for item No.92 to 97. (a) Contractor has to employ following staff for manning & operation of the AC plants at each shifts of 8 hours
(i) One No operator having minimum ITI qualification in Ref Mech/Electrician trade from Govt recognised institute with minimum 2 years experience in maintenance & operation of AC plants in each shift of 8 hrs (Total 3 shifts )( for item No. 92 to 97)
(b) Contractor will maintain proper records of all kinds of daily, weekly , monthly, quarterly, half yearly, yearly or whatsoever maintenance is carried out during contract period in a binded book/register and will obtain the signature of Engineer-in-Charge
(c) The operator/helper will ensure general cleanliness and upkeep of the installation on daily basis.
(d) The routine maintenance/checks shall be strictly carried out by the operator all as per the list of routine maintenance activities with periodicity as per appendix 'A' to PS hereinafter attached.
(e) The unit rate quoted shall deemed include for maintenance for earthpits, cutting & removing of vegitation and upkeep of the surrounding area, all around the bldg upto 6m from the plinth protection all as directed by Engr-in-Charge. In case of failure, a penalty of Rs 2000/- per month will be levied and recovered from dues. (f) The contractor shall provide 02 uniforms to each operator & helper and design of uniform shall be got approved. In case of failure, a penalty of Rs 2000/- per uniform will be levied and recovered from dues. (g) In case of failure due to absence of operative staff, the contractor shall be liable to pay compensation at twice the cost of a day’s Manning & Operation derived from pro rata rate of Sch ‘A’ quoted rates.
(h) The Contractor shall pay the wages to the operators/helpers (as applicable) through e-payment i.e Adhaar linked bank accounts (credit to their bank account). Engineer-in-charge shall ensure that e-payment made to operator/helpers and their wages shall not be less than minimum wages fixed by state Govt or Central Govt whichever is more. Monthly e-banking statement shall be furnished by the contractor to the Engineer-in-charge and the same shall be kept in record duly verified. (j) It is the responsibility of contractor to deposit the employees provident fund (EPF) to the concerned authority as per the prevaling scales as laid down by Ministry of labour for all operator/helper (as appliable) and necessary proof to this regard shall be submitted to the Engineer-in-charge for verification & record. The quoted rates shall be deemend to be included of above provisions. In case contractor fails to produce the proof of EPF, the same shall be recovered from his dues as per the prevailing scale plus 15 percent profit. (k) The contractor shall maintain all the registers under various labour law rules, 2017 and shall be produced to the Engineer-in-Charge as well as officers detailed by central labour department.
(l) Defective parts of plants will be replaced and measured under respective item of this schedule.
(m)Power supply for operating the installations will be made availiable by department free of cost.
Shree Ayyappa Engineering
BRITE INDUSTRIES
Veer High Tech Solution
shakti engineering and electrical works
Darpan Construction
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .