Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹11.4 LAccepted-AOC | 1 | Accepted-AOC Being lowest | |
| 2 | 2₹11.8 L+₹2,050.20 (0.17%)Rejected-Finance | 2 | Rejected-Finance Not being lowest | |
| 3 | 3₹12.5 L+₹77,639.80 (6.62%)Rejected-Finance | 3 | Rejected-Finance Not being lowest |
Tender Value
₹16.5 L
EMD Value
₹33,060
Closing Date
4 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE Agra
112, Taj Road, Agra Cantt
SPECIAL REPAIR TO BLDG NO. T-32 MES BSO STORE AT AGE (I) MES FATEHGARH CANTT
2024_MES_664587_1
86185/E8
Open Tender
Civil Works
Item Rate
180 days
Fatehgarh
MES contractors enlisted for Class E and above and category a(i) for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work
8 documents required · 8 mandatory
₹500
AGE (I) Fatehgarh
₹33,060
14 Nov 2024
8 Jul 2024
11 Sept 2024
8 Jul 2024
4 Sept 2024
22 Jul 2024
8 Jul 2024 - 15 Jul 2024
Amount
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) exc 1.5 sqm each but not exc 4.00 sqm each complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed
S & F in repair 3 mm thick sheet glass ordinary quality and glazing with mitred beads or oil putty including glazing clips in square not exc 0.50 sqm in each pane complete all as specified and directed.
S & F in repair Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, welded tinned tacks, rivets, wooden beads etc. to steel windows/wodden doors/windows complete all as specified and directed.
Demolition of brickwork masonary built in lime or cement mortar including all quiens arches, pillars etc. but including concrete articles complete all as specified and directed.
M & L Brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in cm (1:6) complete all as specified and directed.
-ditto- all as per item No.6 above but except Bricks etc complete all as specified and directed.
Taking down cement plaster on brick wall or stone wall etc. including raking out joints hacking for key, scrubbing down with water etc and disposed off unserviceable material of out side MD land complete all as specified and directed.
M & L Rendering 15mm thick in CM (1:6) on fair faces of brick work or concrete surfaces to be finished even and smooth without using extra cement complete all as specified and directed.
M & L Rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete surfaces to be finished even and smooth without using extra cement complete all as specified and directed.
M & L three coat of white wash on new plastered wall surfaces including preparation all as specified and directed by Engineer-in-Charge.
M & L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar complete all as specified and directed
Demolition of PCC in Ground floors/PCC Path/Plinth Protection and paving n.exc 15cm thickness (below or above ground level) etc complete all as specified and directed.
M & L 75 mm thick PCC 1:3:6 type C-2 using 40mm graded aggregateds as in plinth protection, subbase of floors complete all as specified and directed.
M & L 75 mm thick PCC 1:4:8 type D-2 using 40mm graded aggregates in subbase of floors complete all as specified and directed
M & L for Machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over 20 mm thick screed bed in CM 1:6 complete all as specified and directed.
M & L for Machine cut kota stone slab in skirting 20-25 mm thick over 10 mm thick rendering in CM 1:3 laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including rubbing and polishing complete all as specified and directed.
Dismantaling of asbestos cement (Corrugated, semi corrugated etc) sheetiting in roof covering all as specified and directed by Engineer-in-Charge.
S & F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in ridge, roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Dismantling timber scantlings in framed work 40 sq. cm and over in section, in any position complete all as specified and directed.
S&F Rolled sections of grade Fe 410 - W (Gde E- 250) quality A as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed.
S&F Plates (plain or chequered) of grade Fe 410 - W (Gde E- 250) quality A channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed
S&F Mild steel screw bolts 11-15mm dia, length of bolt exc 5cm but n exc 10cm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square complete all specified and directed
S&F Framed work of grade Fe 410 - W (Gde E- 250) quality A as in doors or gates of angle or other section with gusset plates, rails, braces, framing for cladding, glazing, wire netting and the like etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings including mild steel hinges, mild steel hand made sliding bolt, mild steel handles, mild steel hold fast and all necessary fittings (exclusive of steel sheeting or other covering) and hanging; also fastening and fixing complete all as specified and directed
M&L Preparing new surfaces of steel and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and as directed.
M&L for preparing old painted surfaces of steel and applying two coats of synthetic enamel paint, complete all as specified and as directed.
S&F Wire netting of galvanised steel wire 1.40mm dia and 20mm mesh size fixed with tinned tacks of wire staples complete all as specified and directed
Taking down copper/aluminium point wiring of any description and any position (light, fan, socket or power point) complete, including fixture and fittings such as switches,socket, ceiling rose,lamp holder,pendants, bracket and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified and directed.
Taking down copper/aluminium sub main wiring and making good disturbed surfaces to match with the existing surface roof/wall/floor complete all as specified and as directed.
M&L for point wiring with 1100 volt grade PVC insulated and unsheathed 1.5 Sq mm (FRLS) multistranded copper conductor cable with continuous earth wire of 1.5 Sq mm (FRLS) multistranded copper conductor cable PVC insulated and unsheathed, drawn in & including concealed PVC rigid conduit medium grade with fittings (ISI marked) sunken pressed steel galvanised terminal boxes minimum 1mm thickness with top cover ISI marked plastic laminated hylam sheet for housing/ fixing switches etc for One light/ holder/fan/exhaust fan point controlled by one switch complete all as specified and directed for the following- Note- (i) The quoted rete is deemed to be included for the chases cutting. (ii) Cutting chases for concealed shall be made good using CM 1:4 and surface finished to match the existing surface & colour.
All as per item No.32 here in before but for One 5 pin 5 Amp switch socket combination point on an independent board complete all as specified and directed.
All as per item No.32 here in before but for One 5 pin 5 Amp socket point controlled by one switch on same board complete all as specified and directed.
All as per item No.32 here in before but for one 16 Amp 6 pin switch socket combination independent with 4.0 Sqmm FRLS unsheated copper conductor single core multistranded complete all as specified and directed.
S&F switch piano flush type 5 Amp single pole one way complete all as specified and directed
S&F socket outlet 2 in 1, 3 pin, 6 Amp complete all as specified and directed
S&F switch socket combination 2 in 1 flush type 5 Amp 3/5 Pin complete all as specified and directed
S&F switch socket combination 5 in 1 flush type 16 Amp 5/6 pin complete all as specified and directed
S&F fix electronic fan regulator 5 stepped type complete all as specified and directed.
S&F ceiling rose PVC / poly carbonate isolated body three terminal AC 230 volts complete all as specified and directed.
M&L for sub main wiring with two single core 6 Sqmm FRLS copper conductor PVC insulated and unsheathed cable including PVC conduit medium grade (appropriate size) concealed in wall for sub main connection including 6 Sqmm FRLS insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly complete all as specified and directed. ( Note :- Two runs of 6 sqmm FRLS and one run of 6 sqmm FRLS copper each conductor shall be measured as one unit length.)
Supply and fixing of VTPN DB suitable for mounting MCCB as incomer of rating 100 AMP vertical distribution board 12 way with suitable rated bus bar having IP-43 protection and double metal door concealed in wall including connection with aluminium thimbles as required complete all as specified and directed.
Supply and fixing of MCCB 100 Amp, 240 volt 'C' curve 10 KA complete all as specified and directed.
Supply and fixing of MCB distribution board SPN 240 Volt 8 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with copper thimbles as required complete all as specified and directed.
S&F of MCB SPN 63 Amp, 240 volt 'C' curve complete all as specified and directed.
S&F of MCB SP 6-32 Amp, 240 volt 'C' curve 10 KA complete all as specified and directed.
Supply & Fixing LED light fitting 1 x 20 W, 220 V, AC decorative box type with driver, holder including LED tube light connecting up with free core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick, burried directly into the ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts, and washers of galvanised iron or steel all as shown iln electrical plate No - 3 connected to earthing test point all as specified or indicated including excavation and connected earth work, PCC chamber and cover, watering pipe, funnel wire mesh but with earth lead protection pipe and test on completion after dismantling unserviceable erthing (above GL only) including dismantling of exsisting earthing complete all as specified and as directed.( Note :- On testing after completion if desired earth resistence is not obtained, the earthing will be redone at no extra cost.)
M/S Arvind Electricals (BID ID -3081109)
M/S Shree Gopal Engineers & Contractor (BID ID -3081595)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .