Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
21 Dec 2019, 6:00 pmClosed
Garrison Engineer Nasik Road
Garrison Engineer Nasik Road AOP Complex Near AOP Gate PO Gandhinagar Nasik 422006
AS PER TENDER DOCUMENTS
2019_MES_299202_1
GE/NRC/8719/E8
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer Nasik Road
AS PER NIT
8 documents required · 8 mandatory
₹500
Garrison Engineer Nasik Road
₹40,000
Yes
10 Jan 2020
19 Nov 2019
26 Dec 2019
19 Nov 2019
21 Dec 2019
2 Dec 2019
Amount
Testing only for finding out cable fault location of cable PVC armoured copper conductor single core 16 sqmm (7/1.05) 5 KV from ATC to CCR, CCR to taxiway light fitting/main runway by applying voltage DC source using BICO (UK) cable fault detection test, sort & find out , pin out fault location all as specified and directed by Engr-in-Charge
M&L for maintenance of thyristor type NASU make CCR including repairing of defective CCRs by identifying the fault , replacement of defective PCBs and other components and service the same including caliberation of CCR and complete checking , servicing of quarterly base etc as required all as specified and directed.. Note : Spare parts required will be measured and paid separately under respective items.
20 KW Thyristor type NASU make CCR
Maintenance of Remote Controller Desk
Supply only for Main control card including RMS to DC convertor card.
Supply only Power supply + Driver card.
Supply only Insulation Monitor card.
Supply only Over current Trip- card.
Supply only Relay card.
Supply only TTM Card ( 02 Nos)
Supply only plug in type relays : VDC ( 01 No for each CCR )
Supply only plug in type relays : 48 V DC suitable for 11 pin socket.
Supply only plug in type relays : 240V AC ( 1 No for each CCR )
Supply only T1 300 Trip indication fuses
Supply only high speed semi-conductor protection fuses GS 1000/100 ( 01 no each for 20 KW CCR
Supply only thyristors : H 150 TB 15 ( 02 nos each for 20 KW CCR )
Supply only HRC Fuse link :100 Amps ( 2nos each 20 KW CCR)
Supply only HRC Fuse link : 32 Amps ( 1 nos each 20 KW CCR)
Supply only HRC Fuse link : 4 Amps ( 1 nos each for each CCR)
Supply only Digital TRUE RMS METERS: 10 Amp / 1 AMP ( 1 No for each 20 KW CCR)
Supply only Digital TRUE RMS METERS: 100 Micro Amp DC coil moving meter ( 96X96)..1 each
Supply only Lighting arrestors: 4.5 KV grade ( 2 nos each for all rating of CCR's)
Supply only 2 Pole 8 way brillancy switch ( Totary wafer, MBB type) ( 1 Each for each rating of CCR)
Supply only Power transmission MJ11016 ( 2 Nos each for all rating of CCR's
Supply only 72A contactors ( make : Siemen, model 3TF47) suitable for NASU ,make CCRS ( 20 KW)
Taking down un-directional / bi-directional / medium intensity elevated type omni directional or any other light fitting of any watt / amp / type / make by disconnecting electric connection and refxing the same by connecting electric connection in same location complete all as specified and directed.
Material and labour for earthing complete with copper earth plate electrode size 300 x 300 x 3.0 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including copper earth strip 20 x 3.0 mm earth lead by means of bolts, nuts, check nuts and washers of copper including GI pipe light grade of size of 40 mm dia for protection and GI pipe light grade 20 mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including testing on completion. Note : The unit rate includes for protection pipe and copper earth strip 20 x 3.0 mm from top of earth plate up to 7.5 meter above ground level.
Material and labour for earthing complete with galvanized steel earth plate electrode size 600x600x6.3mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized earth lead 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 15mm dia connected to main earth wire on pole or control board and GI pipe light grade 20mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including testing on completion Note : The unit rate includes for protection pipe and GI earth wire 4.00mm dia from top of earth plate up to 7.5 meter above ground level.
Supply and lay RCC hume pipe 150 mm, class NP2, laid and jointed complete with collars, complete all as specified and directed.
Supply & fix connector kit male suitable for runway copper cable 6 Sqmm to 16 Sqmm including breaking coupling for AMA AVN runway light fitting male type. Make -AMA or eqvt, complete all as specified and directed.
Supply & fix in repairs connector kit female suitable for runway copper cable 6 Sqmm to 16 Sqmm including breaking coupling for AMA AVN runway light fitting female type. Make -AMA or eqvt all as specified and directed..
Supply and fix in repairs straight through joint kit suitable for PVC XLPE HT under ground cable of size 6.0 to 16.0 Sqmm, 5 KV heat / cold shrink type for runway cables and taxi track cables complete all as specified and directed
Supply anf fix in repairs un-directional elevated type high intensity AMA APN runway Approach light fitting suitable for use with 200 Watt/6.6 Amps Halogen Lamp complete with all accessories including lamp and clear or green spreader lense, filters and CI base plate (Make-AMA) complete all as specified and directed.
Supply anf fix in repairs bi-directional elevated type high intensity AMA AUN runway edge light fitting suitable for use with 200 Watt/6.6 Amps Halogen Lamp complete with all accessories including lamp, lense, filters and CI base plate complete all as specified and directed.
Supply & fix in repairs medium intensity elevated type omni directional, AMA ALN LED Taxiway Edge Light Fitting suitable for Taxiway, Apron Edge Lights, Turning pad lifhts for operations at 6.6 Amps, series circuit supply, complete with omindirectional blue lens (glass), Lens clamping mechanims,breakable coupling, gasket, base plate with 6 Nos m - 10 stainless steel both and other acessories including white LED with an integrated encapsulated converter of power consumption approx 45W 6.6A, complete fitting confirming to latest ICAD requirment all as specified and directed. Make - Nasu systems/AMA/ GEC
Supply and fix in repairs Isolating Transformer 15 watt, 6.6 Amp, 500 Volt grade, Make - AMA or eqvt approved make all as specified and directed..
Supply and fix in repairs Isolating Transformer 200 watt, 6.6 Amp, 500 Volt grade, Make - AMA or eqvt approved make all as specified and directed..
Supply and fix in repairs for rolled mild steel work such as joint, channel, angle, or tee sections, fixed indpendently, without connecting plates, etc. (cut to ordinari lengths i.e. within 20mm of the length indicated, complete all as specified and directed. (Stand suitable for fixing LED Taxyway Edge Light approximately 10 Kg per stand x 20 Nos = 200 Kg)
Material and labour for cement concrete in foundation, filling and mass concrete Type C2, 1:3:6 (40 mm graded aggregate) complete all as specified and directed.
Supply and fix in repairs 180 degree filter-Red/Green/Yellow Clear for AMA AUN Runway Fitting (Make-AMA) complete all as specified and directed.
Supply and fix in repairs Red Spreader Lens for APN Eng Fitting (Make-AMA) complete all as specified and directed.
Supply, fix, connect and test LED street light fitting, pressure die cast aluminum housing, heat resistance toughened glass, IP 66 protection, better optics for uniform distribution, aesthetically designed roadway luminiare with excellent thermal management, including wiring from junction box / OH line to the fitting, complete all as specified and directed. (Make - Crompton, Cat Ref. LSTS-45-CDL-I or eqvt. make of Havells / Philips)
Supply, fix, connect and test LED flood light fitting, pressure die cast with IP 66 protection, efficient high output emmitter LED for better distribusion, surge protection device, including wiring from junction box / OH line to the fitting, complete all as specified and directed.(Make - Crompton, Cat Ref. LFL-50-CDL-M or eqvt. make of Havells / Philips)
Supply and fix in repairs Alpha Rex3 digital time switches D-22 Astro, multifunctional digital time switches all as specified and directed by Engineer-in-Charge. ( Make : L&T)
Supply and fix in repaires PVC insulated 3 core 2.5 sqmm multistranded (un armoured 2XY) copper conductor complete all as specified and directed. (Make-Havells or eqvt make of Crompton / Philips)
Taking down unserviceble, damaged, faulty LT/HT underground cable from trenches, wall, floor etc. of any size / core / type / make, removed against item No. 01 and 53 complete all as specified and directed.
Supply, Laying and testing XLPE cable insulated screened , PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty 5000 volts grade with standard copper conductor of size 6 sqmm single core all as specified abd directed. Make : Havells/Finolex /CCI/Ralison
EXCAVATION BY TENCHLESS TECH - Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia. Suitable for 0.4 mpa working pressure.
Excavation in trenches in soft / loose soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cable, RCC poles / stays and struts etc. and getting out including trimming sides and forming bottom surface complete all as specified and directed at site.
Returning, filling in including spreading, leveling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays , struts have been erected and tested , all as specified and directed.
Removing excavated surplus soil (Soft/hard soil) obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed.
Material and labour for high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches of size 50 mm suitable for cable protection of HT cable complete all as specified and directed.
M & L for Unwashed Sand cushioning to under ground cable provided with a layer of 8 cm deep before laying and 15 cm covering above the top edge of cable after laying complete all as specified.Note : measurement shall be done after puning down of sand.
Supply and laying burnt bricks for cable protection laid length wise perpendicular to the axis of cable complete all as specified and directed.
Supply and fix in repairs cable jointing kit of size 4 core 16 sqmm to 50 sqmm all as specified and directed.
Taking down partly unserviceable street/security lights fittings from pol/tower/water tank/wall/hanger for necessary repair to AGE E&M store yard and make serviceable in AGE E/M store yard in front of Department representative and make serviceable as per complaints given by Department through job card/complaint register on day to day basis all as specified and directed by engr-in-Charge.
Fixing only repaired serviceable street /security lights fittings of any size and any type and re-fixed at various location in pole/wall/tower/hanger etc complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs T5 High efficiency/High output FTL lamp, 24W T5 HO - 6500K complete all as specified and directed. (Make-Havells, Cat Ref. LHST27124699 or eqvt make of Crompton / Philips)
Supply and fix in repairs T5 High efficiency/High output FTL lamp, 14W T5 HE - 6500K complete all as specified and directed. (Make-Havells, Cat Ref. LHST27124699 or eqvt make of Crompton / Philips)
Supply and fix in repaires Electronic Ballasts for T5 Flourescent lamps - High Performance (THD<33%), 2x24W FTL complete all as specified and directed. (Make-Havells, Cat Ref. LHBTO1224034 or eqvt make of Crompton / Philips)
Supply and fix in repaires Electronic Ballasts for T5 Flourescent lamps - High Performance (THD<33%), 2x14W FTL complete all as specified and directed. (Make-Havells, Cat Ref. LHST271146994 or eqvt make of Crompton / Philips)
Supply and fix in repairs LED outdoor drivers, suitable for 40-45W street light fitting all as specified and directed. ( Make Crompton cat part No SODQL-65-700-45W or equivalent of Havells or philips )
Supply and fix in repairs lamp holder porcelein /PVC suitable for 14/24W , T-5 street light fitting of any approved make only all as specified and directed.
Supply and fix in repairs lamp holder porcelein for single ended E/T lamps of 70/100W SV/MV , 80/125MV and 150W MH E27 all as specified and directed.
Supply and fix in repairs 1 x 85W CFL, type E-27 all as specified and directed. Make : Crompton/Havells/Philips
Supply and fix in repairs 1 x 65W CFL, type E-27 all as specified and directed. Make : Crompton/Havells/Philips
Supply and fix in repairs power contactors ML-3 , 3 pole rating not less than 40A , 230 coil. All as specified and directed. (Make : L&T/ Siemens/ Legrand )
Supply and fix in repairs power contactors ML-4 , 3 pole rating not less than 70A , 230 coil. All as specified and directed. (Make : L&T/ Siemens/ Legrand )
S& F XLPE insulated armoured and pvc sheated heavy duty electric cable size of 2 core 10 sqmm aluminium conductor 1100 volt grade as per IS 7098 (Part-1) 1988 with latest amendment laid in tranches passing through pipes /ducts including testing complete note- rate is inclusive of cable gland & cable lugs Make- Havells / FINOLEX / GLOSTER / VISHAL
All as per item No 69 here in before but size 4 Core 10 Sqmm
All as per item No 69 here in before but size 4 Core 16 Sqmm
All as per item No 69 here in before but size 3.5 Core 35 Sqmm
All as per item No 69 here in before but size 3.5 Core 50 Sqmm
All as per item No 69 here in before but size 3.5 Core 95 Sqmm
NOTE :- AMOUNT OF SCHEDULE OF CREDIT RS. 46,340.00 WILL BE DEDUCTED FROM TOTAL AMOUNT OF BOQ.
Mayur Electro Enterprises
sapana enterprises
devang Electricals
SHRI SULAI ELECTRICALS
Bidder Name
SHRI SULAI ELECTRICALS
sapana enterprises
DURGAI ELECTRICALS
Mayur Electro Enterprises
devang Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .