RequiredAnnual Turnover
RequiredCertificate (Requested in ATC) Bid to RA enabled No Steel Porta Cabin ( 5 pieces ) ( Under PAC ) Make na Model veenaveems Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) GENERIC Configuration of Cabin With one Room only. With one Room only. Transportations Freight charges Offer Prices are on Free Delivery at Consignee site basis. * Approval of Advance No Advance Sample No Advance Sample 1/8 sample Foundation for Cabin Building of Foundation at site shall be the responsibility of the Consignee and the Seller shall Install Erect and Commission the structure on the foundation constructed upto plinth level by the Consignee. * Special Condition Scope of supply includes Supply and Erection of Cabin at consignee site hence Offer Price to include all these cost components. Further Offer Prices are on Free Delivery at Consignee site basis hence Transportation/Freight charges are to be included in Offer price. Building of Foundation at site shall be the responsibility of the Consignee and the Seller shall Erect the structure on the foundation constructed upto plinth level by the Consignee. In case advance sample is required - after award of contract - Seller shall have to get Advance sample approved from Buyer before manufacturing starting Bulk supplies. Buyer shall approve provide list of modifications required within 10 days of offer of advance sample. If there is delay in approval of advance sample from Buyer side - the delivery period shall be regularized for the period of delay in sample approval. * Time period for completion of Erection work at site Within 30 days of the date of receipt of consignee's Within 30 days of the date of receipt of consignee's 2/8 by seller confirmation regarding completion of ground and foundation work confirmation regarding completion of ground and foundation work Suitability structural stability completness of structures
Requiredthe structure is intended for use in In wind condition of 55m/s - in Seismic zone V and ambient temprature range 0 degree C to (+) 50 degree C - Roof slope 1 : 2 Cabin should be structurally stable and suitable to meet severity of these climatic condition. In wind condition of 55m/s - in Seismic zone V and ambient temprature range 0 degree C to (+) 50 degree C - Roof slope 1 : 2 Cabin should be structurally stable and suitable to meet severity of these climatic condition. Shape of Cabin Square * Type of slope(roof) One way slope. One way slope. Insulation of Wall/Roof door panels N.A * Ventilation 1 no. ventilator - made out of Aluminium adjustable Louvers type channel and to be fixed in wall panel with suitable fastners. * Storage provision N.A N.A Provision for Power Connection The seller to be liable to get the Electric connection through 3 core insulated underground cable covered with PVC pipe from the power supply point provided by the Buyer. The seller to be liable to get the Electric connection through 3 core insulated underground cable covered with PVC pipe from the power supply point provided by the Buyer. Wiring Surface wiring Surface wiring Provision for Cable
RequiredSwitches and Junction box connection Seller to make appropriate provisions for cable laying - installing meter junction box with switches - other related electrical accessories as may be require for the power supply to the Cabin. Seller to make appropriate provisions for cable laying - installing meter junction box with switches - other related electrical accessories as may be require for the power supply to the Cabin. Other requirements Not required. Not required. Completeness of the work Any fittings or items which may not be specially mentioned in the specifications but which are necessary for commissioning of Cabin * 3/8 are to be provided by the Seller without any extra charge. Electricity charges Charges applicable for obtaining Power connection and recurring monthly power consumption charges levied by sevice provider to be borne by Buyer/user depatment. * PANEL MATERIAL Side wall panel material 1.25 mm thick corrugated HR sheet 1.25 mm thick corrugated HR sheet Door panel material Waterproof BWP flush door 34 mm thick Waterproof BWP flush door 34 mm thick Window panel material Polycarbonate sheet of 6 mm thick. Polycarbonate sheet of 6 mm thick. Door and Window canopy material 18 gauge MS corrugated sheet. 18 gauge MS corrugated sheet. Floor panels material 24 mm Block board thickness with FRP coating checkers style. 24 mm Block board thickness with FRP coating checkers style. Roof panel material 18 gauge MS corrugated sheet 18 gauge MS corrugated sheet End panel material 1.25 mm thick corrugated HR sheet * Insulation material for sides and End walls N.A N.A Insulation material for Roof N.A N.A Inside panel material for sides
Requiredend walls & roof N.A N.A FRAME MATERIAL Roof frame Made of MS having stiffner Top 40 mm x 20 mm x 3.2 mm thick Made of MS having stiffner Top 40 mm x 20 mm x 3.2 mm thick Side Panel frame Made of MS having stiffner Top 40 mm x 20 mm x 3.2 mm thick Made of MS having stiffner Top 40 mm x 20 mm x 3.2 mm thick Floor panel frame MS having 50 mm x 50 mm x 1.2 mm MS having 50 mm x 50 mm x 1.2 mm Window panel frame Aluminium glazed sliding window anodized sections frame * Understructure/Base Made up of MS pipe 50 mm x 50 mm x 1.2 mm * 4/8 thick for vertical and beside - Centre block and outer ride with 25 mm x 25 mm x 2 mm thick MS pipe Door panel frame Other than aluminium frame. * Dimensions and Thickness Inside Length ± 15 mm 3050 mm 3050 mm Inside Width ± 15 mm 1220 mm 1220 mm Total Height (mm) ± 15mm 2135 mm 2135 mm Size of Window ± 10 mm 900 mm x 900 mm * Door Width ± 5 mm 915 mm * Door Height ± 10 mm 1980 mm * Size of Door handle SS 304 Latch 200mm * Size of Tower bolt SS 304 125 mm * Size of Aldrop 200 mm x 16 mm of SS 304 * Size of door hinges 100 mm of SS 304 * Size of Door/Window Chajja (projection if any) ± 10 mm 455 mm wide 45 degree slope * Roof projection (if any) ± 10 mm 305 mm to be given on all sides at full height of cabins. 305 mm to be given on all sides at full height of cabins. Total thickness of Wall panel ± 2 mm 20 mm 20 mm Total thickness of Door panel ± 2 mm 20 mm 20 mm Roof ridge height ± 10 mm N.A N.A Almirah/Cabinet size ± 5 mm N.A N.A Verandah size 1800 mm x 1800 mm * MISCELENIOUS Number of Door hinges 2 nos. * Number of Door handles 2 nos. (1 no. each inside and outside) * Number of Tower bolt 1 nos. * Number of Aldrop on each door 1 nos. * safety Grills (for windows) Made from MS square bar of 8 mm having * 5/8 equal spacing of 125 mm Position of door On one of the longer side * Electric fittings Only electric points to be provided for one fan - One light - One bulkhead fitting point - one 5 amp. power point with Switch board including Double pole MCB 20A with metal enclosure - continuous earth wires to be provided and also external earth terminal to be provided. Only electric points to be provided for one fan - One light - One bulkhead fitting point - one 5 amp. power point with Switch board including Double pole MCB 20A with metal enclosure - continuous earth wires to be provided and also external earth terminal to be provided. Number of Doors 1 * Number of Windows 1 no. window 1 no. window Doors (against water ingress in closed condition) N.A * Roof slope 1 : 4 (approx) Self Draining Type * Door opening Internal * Roof ridge To be made out from 0.45 mm thick PPGI sheet. To be made out from 0.45 mm thick PPGI sheet. Flashing item (U track
RequiredL corner etc) N.A N.A Locking/Security Cabin have to be provision of locking Door and Windows to prevent unwanted intrusion and theft. Cabin have to be provision of locking Door and Windows to prevent unwanted intrusion and theft. Overall covered area by Roof ± 10 mm 2745 mm x 3655 mm * COLOUR AND FINISH Colour As per Buyer's choice As per Buyer's choice Top coat Bituminous paint. Bituminous paint. Paint outside As per Buyer's choice As per Buyer's choice Inside finish As per Buyer's choice As per Buyer's choice Logo (if any) Approved logo of desired size to be painted as per Buyer's requirement. Approved logo of desired size to be painted as per Buyer's requirement. WARRANTY Guarantee/Warranty of bought out components OEMs guarantee warranty of all Bought out components to be * 6/8 extended to the user unit - Seller have to submit related documents to the Buyer alongwith supply of Goods. Service Maintenance Replacements/repairs to be borne by the seller in respect of fittings and fixtures during guarantee warrantee period. * Warranty 1 - Year * CERTIFICATION Test reports to be furnished to buyer's on demand Yes Yes OEM of offered product is ISO 9001:2015 certified No No OEM of offered product is ISO 14001:2015 certified No No OEM of offered product is ISO 18001:2007 certified No No * Bold specifications are the golden parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.