Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.4 CrAccepted-AOC GLYPTIC RAIPUR P O BHITA BURDWAN 713102 | BURDWAN | PURBA BARDHAMAN | WEST BENGAL | 713102 | ₹1.4 Cr | L-1 | Accepted-AOC LOA placed to L-1 bidder |
| 2 | L-2₹1.4 CrRejected-Finance | ₹1.4 Cr | L-2 | Rejected-Finance L-2 Bidder |
| 3 | L-3₹1.7 CrRejected-Finance | ₹1.7 Cr | L-3 | Rejected-Finance L-3 Bidder |
| 4 | L--4₹2.1 CrRejected-Finance 501 DELTA TECHNOLOGY STREET HIRANANDANI GARDENS POWAI MUMBAI 400076 | MUMBAI SUBURBAN | MAHARASHTRA | 400076 | ₹2.1 Cr | L--4 | Rejected-Finance L-4 Bidder |
Updated dates
Tender Value
Refer Docs
EMD Value
₹2.8 L
Closing Date
19 Mar 2026, 3:00 pmClosed
CE (P)
Room 42, SCM Section, Dronagiri Bhavan, Uran Plant
REVAMPING AND EXPANSION OF EXISTING SMOKE DETECTION SYSTEM AT ONGC URAN PLANT AND ONGC TROMBAY TERMINAL WITH FIVE YEARS POST WARRANTY COMPREHENSIVE AMC
2026_ONGC_267781_1
UA5CC26001
Open Tender
Miscellaneous Works
210 days
ONGC URAN PLANT
Please refer Tender documents.
11 documents required · 11 mandatory
₹0
₹2.8 L
12 May 2026
19 Feb 2026
20 Mar 2026
19 Feb 2026
19 Mar 2026
19 Feb 2026
Lum-Sum Price for LSTK Component: Lump sum price for Design, Engineering, Supply, Installation, Integration, Networking, Testing and Commissioning of the new intelligent addressable microprocessor based Smoke Detection Systems (SDS) including replacement of existing SDS at ONGC URAN & Trombay Terminal as per the enclosed scope of work. Rates are inclusive of all taxes, duties, levies, insurance, octroi, cess etc. including but not limited to applicable custom duty, excise duty sales tax,work contract tax, GST as applicable to complete the job.
Lump sum Charges for comprehensive annual maintenance contract (AMC) for 5 years for the entire system for “Revamping & Expansion of Existing Smoke Detection Systems at ONGC Uran Plant & Trombay terminal" after 1 year warranty period including the batteries for all power supplies of the panels inclusive of all taxes as per Scope of Work.
TOTAL LUMP SUM PRICE (I.E. A + B = C)
Description of Item
Microprocessor based fire alarm control panel, expandable to minimum 8 loops fully networkable with each loop capable of taking at least 126 devices with a min loop length support of 1500mtrs. The system should be in accordance with NFPA- 72 and UL/FM Listed approved or EN 54 with VDS/LPC approval. Electronics, power supply and batteries for continuous 8hrs operation with full load
Microprocessor based fire alarm control panel, expandable to minimum 4 loops fully networkable with each loop capable of taking at least 126 devices with a min loop length support of 1500mtrs. The system should be in accordance with NFPA- 72 and UL/FM Listed approved or EN 54 with VDS/LPC approval. Electronics, power supply and batteries for continuous 8hrs operation with full load
Microprocessor based fire alarm control panel, expandable to minimum 2 loops fully networkable with each loop capable of taking at least 126 devices with a min loop length support of 1500mtrs.. The system should be in accordance with NFPA- 72 and UL/FM Listed approved or EN 54 with VDS/LPC approval. Electronics, power supply and batteries for continuous 8hrs operation with full load
Microprocessor based repeater Panel
Intelligent Multisensor Addressable smoke detectors (Model - 58000-700 APO)
Intelligent Addressable Heat Detectors (Model - 58000-400APO)
Apollo Discovery Multisensor Detector Base (Model -45681-210APO)
LED type Response indicator having coloured LED lamp including connections etc..
Addressable intelligent MCP (Model Ravel RE-716P1T )
Mini Switch Monitor Module (Model -55000-760APO)
Apollo Addressable base sounder with Red Cap. (Model - 45681-277APO)
Relay modules for potential free contacts (Model - 55000-847SIL)
LHS Zone Interface Unit (Model - 55000-845APO)
Fault Isolator (Model - 55000-720APO)
Hardware required for modification & interfacing with Mimic Panel
LHS cable
HMI PC/workstation with necessary Graphical User Interface sofwares
Network components eg, FO converters, Patch cords, Ethernet Switches, LIU/Patch panels, Components for fiber termination etc.
Foldable Step Ladder 1) Min Height - 2mtr 2) Min Height 4 mtrs (MOC - Aluminium)
Supply of Six core Single mode/ Multimode Fibre optic cable with PVC conduit for interconnection of all the SDS panels for looping Fire Control Room Panel-6 & APU SRR Panel-9
Supply of 3Cx 2.5 sq.mm , 1.1 kV FRLS copper conductor flexible armoured cable with steel braided including connectors, PVC conduit etc.. as required
Supply of 2Cx 1.5 sq.mm (14SWG), 1.1 kV grade flexible FRLS copper conductor armoured twisted cable with steel braided and overall shielded with aluminum mylar tape, including connectors, PVC conduit etc.. as required
Description
Laying of 2Cx 1.5 sq.mm , 1.1 kV grade flexible FRLS copper conductor armoured twisted cable with steel braided and overall shielded with aluminum mylar tape, including connectors, PVC conduit etc. as required
Laying of Six core single / multi mode armoured fibre optic cable that integrates all the SDS control panel at Uran Plant with PVC conduit etc. and termination of all six cores of FO cables at respective locations.
Laying of LHS cable
Installation and Commissioning of new system & revamping of existing system that includes SDS control panels, Repeater panels, Smoke Detectors, MCPs, Hooters, Relay modules & LHS Zone Interface Modules etc. including Engineering, Configuring, Testing & Documentation etc. of the entire system as per the Scope of Work including Dismantling of the old system and shifting of all the scrap materials generated during execution of the work to the site designated by ONGC.
Revamping and Commissioning of Mimic Panel, 02 No HMI workstation, Network Switch, Processor Node or any other controller necessary for successful integration of all SDS control panel for centralized monitoring facility at Fire Control Room including Engineering, Software Designing, Configuring, Testing & Documentation etc. of the entire system as per the scope of work.
Description
Charges for Post Warranty Comprehensive AMC, including supply of spares for 5 years (20 quarters) for Uran Plant & Trombay Terminal inclusive of applicable tax etc. as per scope of the comprehensive AMC for Intelligent Addressable Smoke Detection Systems (SDS).
TENDER DOCUMENT/ BEC CLAUSE REFERENCE
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.26 MB
UA5CC26001.rar
Tender Documents • 5.58 MB
BOQ.xls
Additional Documents • 0.06 MB
Download all tender documents and submit your bid