GARRISON ENGINEER I GOS
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
SPECIAL REPAIR TO BLDG NO P 404 NEAR KURUKSHETRA TRAINING AREA AT GMS UNDER GE I GOS
2021_MES_482983_1
8000/70/21-22/0969/E8
Open Tender
Civil Works
Item Rate
180 days
GOPALPUR ON SEA
PLEASE REFER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER I GOS
₹90,000
Yes
17 Dec 2021
21 Oct 2021
26 Nov 2021
21 Oct 2021
24 Nov 2021
18 Nov 2021
Amount
Demolition of Cement Concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified & directed.
M&L for 10mm thick Light shade vitrified ceramic tiles in floors, not exceeding 0.36 sqm, set & jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed.
M&L for 10mm thick Light shade vitrified ceramic tiles in skirtings/ vertical surfaces, not exceeding 0.36 sqm, set & jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed.
Dismantling of floor, hearth, walls, roof tiles including bedding (but not backing), and rubbish off permises complete all as specified and directed.
M&L for Rendering 10 mm thick in cement mortar 1 : 4 for fixing of wall tiles complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring average 25 mm thick surface finished even and rough (as in levelling course) to receive the topping layer complete all as specified and directed.
M&L for screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:6 for laying of floor tiles complete all as specified and directed.
Dismantling of Wooden Wall Panelling with base plywood work incl all hardware items and removing to store complete all as specified and directed.
M&L Plywood, grade BWR, type BB, 12 mm thickness in first layer for making the base for second layer for panelling fixed with nails to timber framework complete all as specified and directed.
M&L Plywood, grade BWR, type BB, 12 mm thickness in second layer for making the base for Wooden panelling fixed with screws complete all as specified and directed.
M&L Wooden Wall Panelling with 12 mm thick teak wood board planks of width 300 mm finishing plain and even complete all as specified and directed.
M&L for preparation of newly untreated wooden surfaces of any description not other wise described over 10cm width or girth and applying two coats of wood varnishing over one coat of transparent wood filler liquid complete all as specified and directed.
M&L Wooden lining top border of size 35 mm x 50 mm all along the Wall Panelling complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs /blankets, any thickness, including cover fillets complete all as specified and directed.
S&F 12 mm thick Perforated particle board for insulation and accoustic purposes, 60 x 60 cm in size, fixed with screws to timber framework or with staples on snap grid, fixer flat or sloping or in ceiling complete all as specified and directed.
M&L Wood wool building slabs, 20 mm thick light weight, type 1, fixed with nails to timber framework, fixed flat or sloping complete all as specified and directed.
S&F 12 mm thick plain Gypsum Board False Ceiling with GI frame including all necessary drilling cutting to fix electric items complete all as specified and directed with following:- (a) GI Grid channel 30x25x20 mm of 24 gauge fixed with rawl plug and screw 450 mm centre to centre alongwith perimeter walls. (b) GI channel made to shape 50x40x40 mm of 24 gauge placed @ 600 mm centre to centre from perimeter at wall except long wall (in one span). (c) GI intermediate runners of size 45x10x10 mm of 24 gauge fixed @ 1200 mm centre to centre leaving frame of one side walls (in other span). (d) GI sheet 25 mm wide and 20 mm gauge suspended fixed with steel fastner to roof ceiling and 1200 mm centre to centre including pluging of RCC Slab. (e) 12 mm thick gypsum board filling joints with POP and finishing complete with two coat of plastic emulsion paint over one coat of primer on ceiling.
Excavation in trenches in soft/ loose soil, not exceeding 1.5m wide and not exceeding 1.5 m in depth for foundation, n exc 10 sqm in plan and getting out complete all as specified and directed.
M&L for Cement concrete Type D-2, 1:4:8 (Using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified & directed.
M&L for Reinforced cement concrete (Design mix) M-30 (using 20 mm graded aggregates) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for Reinforced cement concrete (Design mix) M-30 (using 20 mm graded aggregates) as in Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for Reinforced cement concrete (Design mix) M-30 (using 20 mm graded aggregates) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L for Reinforced cement concrete (Design mix) M-30 (using 20 mm graded aggregates) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, Flat, with fair finished surfaces complete all as specified and directed.
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions (circular on plan) with fair finished surfaces complete all as specified and directed.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. Flat, with fair finished surfaces complete all as specified and directed.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) Flat, with fair finished surfaces complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as speified and directed.
M&L for Mild steel TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as speified and directed.
M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as speified and directed.
Dismantling wrought iron or mild steel work/ old railing of any description complete all as specified and directed.
M&L for Cutting holes in existing concrete treads, supply and fixing Guard Bars of 100 mm centre to centre spacing and Wooden railing of approved pattern using sections where handrails are of wood of depth 200 mm and thickness 70 mm and , fixing with adequate support from bottom and side walls, making good the holes with PCC 1:2:4 including necessary fabrication, finishing the joints etc complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L for Brick work with fly ash bricks straight or curved on plan exceeding 6 m mean radius complete built in cement mortar 1:6 complete all as specified and directed.
M&L for Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed.
S&F Providing precast cement concrete type B-0 1:2:4 (using 12.50 mm graded stone aggregate) louvres and jallies, 35mm thick (measured solid), including all mouldings set in CM 1:4 complete all as specified and directed.
Taking down cement plaster on brick or concrete surface including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for Rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) complete all as specified and directed.
M&L for applying 2mm thick Birla / JK Putty in two layers on newly plastered walls surfaces making absolutely even and smooth, rubbing with sand paper complete all as specified and directed
M&L for applying 2mm thick Birla / JK Putty in two layers on old wall surfaces including complete removal of existing wall finish of any type with wire brush, brooming, dusting and finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc. and surfaces absolutely even and smooth, rubbing with sand paper complete all as specified and directed.
M&L for applying two coats of oil bound distemper on wall or concrete surfaces on prepared surfaces including, rubbing with sand paper complete all as specified and directed.
Taking down chowkhat or frames exc 1.50 Sqm but n exc 4 Sqm each with shutters (without taking off shutters from the frame) and removing to store complete all as specified and directed
S & F Powder coated three track Aluminium sliding window with frame not less than 1.8 mm thick excluding aluminium grill and including 4 mm thick tinted glass, beading & necessary rubber packing, locking & opening arrangement, all fitting and fixture complete all as specified and directed.
S&F Door closer hydraulically regulated designation No 2, universal type, suitable for door shutter of weight between 36 to 60 Kg of aluminium (Die cast) body complete all as specified and directed.
S&F Powder coated Fixed Aluminium Partition with frame not less than 1.8 mm thick including 5 mm thick tinted glass with or without 12 mm thick prelaminated particle board, exterior grade, prelaminated both sides with decorative choice laminations beading & necessary rubber packing, all fitting and fixture complete all as specified and directed.
S&F 7mm thick aluminium grills of make "Decogrill' model DG 104 surrounded by aluminium 'C' channel with mesh size 99 X 105mm complete all as specified and directed.
S&F aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples complete all as specified and directed.
M&L for applying two coats of acrylic exterior weather proof emulsion paint over a coat of exterior primer on newly plastered wall surfaces/ old decorated wall surfaces, in case of old decorated wall surfaces includes complete removal of existing wall finish of any type with wire brush, brooming, dusting & finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc complete all as specified and directed.
M&L for Complete removal of existing treatment and preparation stone surface (Khandolite tiles ) and applying two coats of Paints on stone walls of approved make and colour complete all as specified and directed.
M&L for hard core of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 100 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as sub base of floor complete all as specified and directed.
M&L for 10 mm thick heavy duty exterior designer tiles of size 300 mm x 300 mm as in floor set, jointed in neat cement slurry and pointed with grey cement and pigment complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN Dbs/TPN DBs/ Main switch including old unserviceable MCCBs/ MCBs isolators etc and making good to disturbed surface complete all as specified and directed.
Taking down care fully copper/ aluminium sub main wiring of any size from surface / concealed / esisrting conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed
M&L for point wiring with 1.5 Sqmm signle core PVC insulated unsheathed copper FRLSH multi stranded conductor cable in and including concealed PVC conduit of size 20/25 MM ISI marked inclusive of tees, bend, elbows etc upto and including GI sunk boxes of size 1.2 mm thick and 60mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switch/ socket of suitable size complete including PVC insulated multi stranded copper conductor 1.5 Sqmm FRLSH cable as earth wire to common earth dolly for connection to ceiling rose to earth terminal incuding cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for following:- (a) One light point controlled by one , one way switch 5 Amp
(b) One fan point/ exhaust fan point controflled by one, one way switch 5 Amps and regulator
(c) One 3 pin 5 Amps witch socket outlet point controlled by one switch on the same board
(d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board
All as per item No 58 above but using 2.5 Sqmm single core copper conductor cable of multistranded flame retardent PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combition point including necessary running of 2.5 Sqmm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly.
All as per item No 58 above but using 4.0 Sqmm single core copper conductor FRLSH cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combition point including necessary running of 2.5 Sqmm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F Modular switch 1 way 6A, 1 module, 230 volts complete all as specified and directed.
S&F in replacement of modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed.
S&F modular Switch socket Combination 16A, 6 pin, 3 module complete all as specified and directed.
S&F in repairs modular Switch socket outlet 3 pin 5 amp' flush type complete all as specified and directed
S&F for modular Switch socket outlet multipurpose 3 pin, 15 amp and one pin, 5 amp controlled by one switch complete all as specified and directed.
S&F for modular Fan step regulator, 120W - 2 module, 230 volts complete all as specified and directed.
S&F for Sheet metal enclosure factory made double door for mounting MCBs with 200A rated bus bar capacity SPN 16 way AC 240 Volts with IP-43 protection, complete all as specified and directed.
S&F Ceiling rose 3 terminals of PVC/ polycarbonate, as per relevant IS code, ISI marked isolated body complete all as specified and directed.
M&L Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, burried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less'than 1.5 meters below normal ground level, connected to galvanised iron earth lead wire of 4 mm dia GI pipe mediam grade 15 mm dia upto 7.5 mtr including provn of conrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 kg/sqm) and frame of angle iron 25x25x3 mm with lugs 02 Nos and with 6.0 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for earth plate, common sald and charcoal filing, test point made out of Bronze/ Gun metal with fixing arrangement, funnel, wire mess and excavation/ earthwork in hard/ dense soil, to a distance not exceeding 50 mtr all as per electrical plate No 3 of SSR 2010 Part I and connecting to earth test point complete all as specified or indicated incl testing on completion.
M&L Submain wiring with two single core 6 Sqmm size stranded copper conductor PVC insulated unsheathedcable FRLS in and incl PVC rigid non metalic conduit concealed/ surface type and one PVC cable of 4.0 Sqmm size solid copper conductor PVC insulated andunsheathed for continous earth wire with junction boxes covered with laminated sheet 3 mm thick and other accessories complete all as specified and directed.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of capacity 40 to 63 Amp SPN 240 Volts and current carrying capacity in the MCB DB complete with connection testing and commissioning
S&F of 12W mondern LED long glass gold pendant lamp ceiling light 220 volts complete all as specified and directed.
S&F Recess mounting LED slim ceiling light with extruded aluminium housing and milky diffuser of capacity 45 watt 2x2 ft ceiling recess fitting with capacity 45W 220 volts complete all as specified and directed.
S&F 6 watt led crystal up and down wall lamp (warm white) 220 volts complete all as specified and directed by. Make : Smartway or equivalent of high cost.
S&F LED Round Surface PDC Aluminium Housing Downlights 18W 220 watt complete all as specified and directed. Make: C&S model No LTCRSUR18HPLEDRND/W or equivalent of high cost
S&F LED step light wall lamp 3 watt capacity (warm white) polyresin body complete all as specified and directed.
M/S. KISHAN ENGINEERING
DHABALESWAR ENGINEERING WORKS
M/S SIWALIK AND CO
M/s Ats Electricals
M/s MAA BHAIRABI ENTERPRISES
HARAGOURI SUPPLIERS
M/S S.K GHOSE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .