Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC | ₹1.3 Cr | L1 | Accepted-AOC ACCEPTED |
| 2 | L2₹1.4 Cr+₹5.8 L (4.35%)Rejected-Finance | ₹1.4 Cr+₹5.8 L (4.35%) | L2 | Rejected-Finance NOT THE LOWEST BIDDER |
| 3 | Rejected-Technical | - | - | Rejected-Technical REJECT DUE TO ESIC NOT SUBMITTED |
| Sl No | Description | Qty | Unit | Athengsa Tamai L1 | ARRYA ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.00Total amount of Sch 'A' Part-I Building Works Note :- This schedule is not pre-priced by MES and the rate indicated as "Rs. 0.00" under column 6 signifies this fact only. | |||||
| 2.00 | Design, Fabrication and Construction of Central MI Room for the 368.10 Sqm at Tezu Mil Stn as shown in line plan / site plan and detailed DPR , such as RCC framed structure as per site plan and line plan and revised thereof. Specification given in Sch A Note and particular specifications including complete RCC foundation and plinth, flooring Joinery and Finishes complete all as specified.
(i) Size – As per Arch drawing (ii) Height – as per Drg
(iii) Fdn – To be design as per SBC report with RCC framed construction. (iv) Plinth – Burnt Brick wk in CM 1:6
(v) DPC – 40 mm thick PCC 1:2:4 with WPC
(vi) Super Structure – All RCC structure to be M25 design mix burnt brick wk wall upto ceiling.
(vii) Seismic Zone – Strengthening measures for Zone V
(viii) RCC Roof slab 150 mm thick shall be provided as per shown in structural design drawing with APP roof treatment.
(ix) Ceiling : False ceiling with powder coated snap grid frame work.
(ix) Internal Plaster – Internal 15 mm thick in CM (1:6)
(x) Mirror polished kota stone on, verandah & non skid ceramic tiles in toilet and bathroom over 15 mm thick screed bed in base of CM 1:6 over a layer of PCC 1:2:4 over sub base of 1:5:10.
(xi) Dado/Skirting – Glazed ceramic tiles over 10 mm thick cement screed in CM (1:3) up to lintel height.
(xii) Joinery – Frames – pressed steel, shutter – Factory made flush door shutter (TD Drg No CESZ/2015/TD/03 Sheet 1/2 & 2/2) & molded / WPC doors in toilet bathroom
(xiii) Joinery Window – aluminum powder coated window with Guard bars/grill
(xiv) Stainless steel routing on first floor of verandah & staircase.
(xv) Iron monger – Prefabricated aluminum anodized fittings. (TD Drg No CESZ/2015/TD/03 Sheet 1/2 & 2/2)
(xvi) Plinth Protection – 75 mm thick PCC 1:3:6 over stone hard core. (xvii) Painting – Synthetic enamel paint on steel/wooden surface.
(xviii) Finishes – Internal - 02 coats of oil emulsion distemper incl 1mm thick wall care putty over a coat of primer. External - 02 Coats of weather proof exterior emulsion over one coat of primer. (xix) Antitermite treatment - As per IS-6313 Part-II : 2001 (xx) Mosquito proofing - All external doors & Windows (xxi) 18mm thick granite over CM 1:3 for steps
(xxii) Sanitory Fitting – Vitreous China EWC, WHB ect of approved make including plumbing work (TD Drg No CESZ/TD-38 Sheet No 1/2 & 2/2 and TD Drg No CESZ/TD-31 Sheet No 1/2 & 2/2).
(xxiii) Mosquito Proofing – All external Door and window.
(xxiv) Green marbles on steps & raiser on staircase. | 1 | LUMP SUM | 1,08,50,000 ₹1,08,50,000 Lowest | 1,13,00,000 ₹1,13,00,000 |
| 3.00NOTE: Schedule ‘A’ Part II to X are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured. | |||||
| 5.00 | Total amount of Sch ‘A’ Part II (Air conditioning & Refrigeration ) | 1 | LUMP SUM | 1,67,000 ₹1,67,000 Lowest | 1,71,969.38 ₹1,71,969.38 |
| 6.00 | Total amount of Sch ‘A’ Part III (Fire alarm system ) | 1 | LUMP SUM | 1,60,000 ₹1,60,000 Lowest | 1,64,305.4 ₹1,64,305.4 |
| 7.00 | Total amount of Sch ‘A’ Part IV (DG Set) | 1 | LUMP SUM | 44,700 ₹44,700 Lowest | 45,864.99 ₹45,864.99 |
| 8.00 | Total amount of Sch ‘A’ Part V (Road/Path/culverts) | 1 | LUMP SUM | 1,05,000 ₹1,05,000 Lowest | 1,07,646.32 ₹1,07,646.32 |
| 9.00 | Total amount of Sch ‘A’ Part VI (External Water Supply) | 1 | LUMP SUM | 61,500 ₹61,500 Lowest | 63,161.94 ₹63,161.94 |
| 10.00 | Total amount of Sch ‘A’ Part VII (External Electrification) | 1 | LUMP SUM | 66,000 ₹66,000 Lowest | 67,775.21 ₹67,775.21 |
| 11.00 | Total amount of Sch ‘A’ Part VIII (Sewage Disposal) | 1 | LUMP SUM | 2,90,000 ₹2,90,000 Lowest | 2,98,328.3 ₹2,98,328.3 |
Tender Value
₹1.4 Cr
EMD Value
₹1.6 L
Closing Date
24 Mar 2026, 6:00 pmClosed
CWE DINJAN
COMMANDER WORKS ENGINEER DINJAN
PROVN OF CENTRAL MI ROOM AT TEZU MIL STN UNDER GE P LOHITPUR
2026_MES_754432_1
84525/E8
Open Tender
Civil Works
Lump-sum
455 days
GE (P) Lohitpur
AS PER TENDER DETAILS
8 documents required · 8 mandatory
₹1,000
GE (P) Lohitpur
₹1.6 L
Yes
10 Jun 2026
26 Feb 2026
31 Mar 2026
26 Feb 2026
24 Mar 2026
19 Mar 2026
Total amount of Sch 'A' Part-I Building Works Note :- This schedule is not pre-priced by MES and the rate indicated as "Rs. 0.00" under column 6 signifies this fact only.
Design, Fabrication and Construction of CENTRAL MI ROOM AT TEZU MIL STN in RCC Framed Structure as per Site plan and line plan and revised thereof. Specification given in Sch A Notes and Particular Specifications including complete RCC foundation and plinth, Flooring, Joinery and Finishes complete all as specified. (i) Size – As per Arch drawing (ii) Height – as per Drg (iii) Fdn – To be design as per SBC report with RCC framed construction. (iv) Plinth – Burnt Brick wk in CM 1:6 (v) DPC – 40 mm thick PCC 1:2:4 with WPC (vi) Super Structure – All RCC structure to be M25 design mix burnt brick wk wall upto ceiling. (vii) Seismic Zone – Strengthening measures for Zone V (viii) Roof – 0.50mm thick Pre-painted Galvalume sheet with MS steel frame structure on living area, roof slab with roof treatment - 150 mm thick on ground floor roof verandhah & Bathroom. (ix) Ceiling : False ceiling with powder coated snap grid frame work. (ix) Internal Plaster – Internal 15 mm thick in CM (1:6) (x) Mirror polished kota stone on, verandah & non skid ceramic tiles in toilet and bathroom over 15 mm thick screed bed in base of CM 1:6 over a layer of PCC 1:2:4 over sub base of 1:5:10. (xi) Dado/Skirting – Glazed ceramic tiles over 10 mm thick cement screed in CM (1:3) up to lintel height. (xii) Joinery – Frames – pressed steel, shutter – Factory made flush door shutter (TD Drg No CESZ/2015/TD/03 Sheet 1/2 & 2/2) & molded / WPC doors in toilet bathroom (xiii) Joinery Window – aluminum powder coated window with Guard bars/grill (xiv) Stainless steel routing on first floor of verandah & staircase. (xv) Iron monger – Prefabricated aluminum anodized fittings. (TD Drg No CESZ/2015/TD/03 Sheet 1/2 & 2/2) (xvi) Plinth Protection – 75 mm thick PCC 1:3:6 over stone hard core. (xvii) Painting – Synthetic enamel paint on steel/wooden surface. (xviii) Finishes – Internal - 02 coats of oil emulsion distemper incl 1mm thick wall care putty over a coat of primer. External - 02 Coats of weather proof exterior emulsion over one coat of primer. (xix) Antitermite treatment - As per IS-6313 Part-II : 2001 (xx) Mosquito proofing - All external doors & Windows (xxi) 18mm thick granite over CM 1:3 for steps (xxii) Sanitory Fitting – Vitreous China EWC, WHB ect of approved make including plumbing work (TD Drg No CESZ/TD-38 Sheet No 1/2 & 2/2 and TD Drg No CESZ/TD-31 Sheet No 1/2 & 2/2). (xxiii) Mosquito Proofing – All external Door and window. (xxiv) Green marbles on steps & raiser on staircase.
NOTE: Schedule ‘A’ Part II to X are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured.
Total amount of Sch ‘A’ Part II (Air conditioning & Refrigeration )
Total amount of Sch ‘A’ Part III (Fire alarm system )
Total amount of Sch ‘A’ Part IV (DG Set)
Total amount of Sch ‘A’ Part V (Road/Path/culverts)
Total amount of Sch ‘A’ Part VI (External Water Supply)
Total amount of Sch ‘A’ Part VII (External Electrification)
Total amount of Sch ‘A’ Part VIII (Sewage Disposal)
Total amount of Sch ‘A’ Part IX (Area Drainage)
SCH 'A PART X (Miscellaneous B/R and E/M works) Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 6 signifies this fact only
M & L for boring 100 mm dia hole in all kind of soil upto maximum depth 6 meter or up to refuse (N=100) whichever meet earlier including collection of undisturbed sample from cohesive soil only conducting standard penitration test at 6 meter and 1.5 meter interval alternatively as per relevant IS code complete all as directed.
Completion of field work & lab test result and submission of report in Per Job quadruplicate suggesting depth of foundation type of fundation and safe bearing capacity with CD-1 (one) copy complete all as specified and directed.
Supply and laying DWC 50mm pipe SN8 laid in trenches for protection of cable all as specified and directed by the Engr-in-Charge.
Supply and Fix DOL Starter FOR 1 HP Motor all as specified and as directed by Engr-in-charge.
Supply and fixing pumpset,cetrifugal,electric driven 1 HP AC single phase 230V inclusive of electrical connections and PCC foundation with MS frame and GI sheet cover all as specified and as directed by Engr-in-charge.
Supply and fix Voltage stabilizer for automatic operation,single phase and naturally air cooled indoor type and designed for input variation between 130V to 280V with output voltage stabilized at 230V with accuracy of ± 2.5% and of capacity upto 5KVA complete all as specified and directed
Supply, installation, testing and commissioning of silent type Direct Injection water cooler Diesel engine driver Generating set of capacity 35KVA comprising of 4 cylinder in line, 4 stroke rated at 1500 RPM in line not less than 50 BHP, with AMF Control Panel with necessary protection & measures and accessories complete as per the standard design of original OEM of DG Set including sound proof canopy confirming to BS-5514 with the following specifications- ENGINE (i) In line fuel pump with mechanical governor suitable for 35 KVA DG Set. (ii) Stainless steel exhaust flexible coupling and exhaust pipe to insulated with glass fire wool to be claded with plain Gl sheet and extended outside the building. (iii) Silencer extended outside to the building complete. (iv) Radiator. (v) Coolant inhabitor. (vi) Plate type lubricant oil cooler. (vii) Spin-on-filter-coolant, fuel & lubricant oil. (viii) Dry type heavy duty replaceable paper element air cleaner with restriction indicator, (ix) Flywheel housing and flywheel to suit single bearing alternator. (x) Battery charging alternator. (xi) 12Volts 80Ah Battery with multistranded copper cable for connecting wire and terminals complete. (xiii) First Fill Lub Oil. ALTERNATOR (i) Self excited, self regulated. (ii) Voltage regulation plus/minus 1 percent. (iii) Class H insulation. (iv) Silent pole revolving field. (v) Digital automatic voltage regulator. (vi) Telephone interference factor-50. (vii) Total harmonic factor Better than 2%. (viii) Supplying power to variable electriaci load for inlimited hours. Prime power (PRP) is in acordance with ISO 8528. Ten percent over load capacity for one hour every 12 Hrs of operation and will be suitable tropical conditions. FUEL TANK (i) Fule tank suitable capacity for minimun 12 hrs run with provision for supply and return lines, level indictor, drain value, cleaning cover, vent pipe & locking devices shall be provided. (ii) Fule pipe line from fuel tank to FIP suitable size. (iii) The fule tank has to be mounted/located in side the cubicle ACOUSTIC ENCLOSURE (i) Designed to meet stringent MoEF/CPCB norms 75dBA @ 1 Meler. (ii) Air inlet louvers to be designed to operate at rated load even at 50 degree centrigrade air inlet temp (iii) Cubical to be powder coacted for long lasting service life and super finish with UV resistent power coating, it has to with stand extrame enviornment. Has to be use stainless steel hard ware. (iv) Insulation meaterial has to ments exacting IS 5183 speces for etter sound. (v) Provision of a controller Engine & alternator
ACCESSORIES, (i) Periodical maintenance tools as per manufacture. (ii) Minimum two uears spares as manufactures design (iii) Operational, spare parts & installation guide line catalogue. AMF CONTROL PANEL FOR DG SET. (i) MCCB 63 Amps, 4 pole, 415 volls, 25 KA, 50 Hz with thermal magnetic and electronic earth leakage module-01 or equivalent in specified Makes. (ii) Power contactors of suitable sizes, Air breake type-02 Nos (iii) Digital type multi functional meter-01 Nos. (iv) Current transformer (CT) of rating 100/5, tape wound, rated burden 5VA-03 Nos. (v) Micro processor based relay manual switch-01 Nos (vi) Sutiable annunciation with features of following protections:- Over voltage, under voltage, under frequency, Low pressure oil. (vii) Chage over switch four pole-two way with Center off -400 Volts, 63 amps, open execution type, equivalent in specifed makes. Note :- (a) Provision of PCC plateform as per manufacturer guidelines/ specifications, the cost of the same shall be deemed to be included in the unit quoted rates. Nothing shall be admissible on this account (b) Testing of the DG Set shall be carried out by the rep of the accepting office/ IEM (c) The Contractor shall submit the drawing for approval of the GE before procument of the DG Set (d) Resistive load whether water load or strip heaters of suitable capacity and POL/ DHPP for testing of DG Set to be made abailable during test by the contracotr. (e) The DG Set shall be procured from authorized OEM and of same group. The accoustic panel shall also be manufactured by the same OEM (f) Anything missed out above bht is requried for efficient working of GD set is deemed to be included in the unit quoted rate (g) Eartings LT cable and other connected works shall be measured and paid seperately under releveant schuedule.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.22 MB
TenderDocuments84525.pdf
Tender Documents • 1.34 MB
BOQ_844999.xls
BOQ • 0.23 MB
drawings.pdf
Additional Documents • 11.36 MB
Amendment1.pdf
PDF • 0.07 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .