Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹13.2 LAccepted-AOC NAGLA UDHA NEAR PRIMARY SCHOOL POST DHANOLI AGRA UP AGRA 282010 | AGRA | AGRA | UP | 282010 | 1 | Accepted-AOC Due to credit and L-1 | |
| 2 | 2₹15.5 L+₹1.5 L (10.9%)Rejected-Finance | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹16.8 L+₹2.8 L (20.1%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | 3 | Rejected-Finance Being other than L-1 | |
| 4 | 4₹18.1 L+₹4.1 L (29.4%)Rejected-Finance KE 100 B KAVERI KUNJ PHASE I KAMLA NAGAR AGRA 282005 | AGRA | AGRA | UTTAR PRADESH | 282005 | 4 | Rejected-Finance Being other than L-1 | |
| 5 | 5₹18.2 L+₹4.2 L (30.1%)Rejected-Finance 38 49 D OLD IDGAH COLONY AGRA U P 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | 5 | Rejected-Finance Being other than L-1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
15 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Adm Area Agra 282008
GE (AF) Adm Area Agra 282008
REPAIR AND MAINT TO STREET LIGHTS BUS BAR BOXES AND OTHER CONNECTED WORKS IN 4 AREA AND MAP PH II UNDER GE AF ADM AREA AT AF STATION AGRA
2023_MES_597002_1
8000-2046/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF Station Agra
Class E
cat b i
8 documents required · 8 mandatory
₹500
GE AF Adm Area Kheria Agra
₹40,000
Yes
24 Jun 2023
20 May 2023
17 Jun 2023
20 May 2023
15 Jun 2023
3 Jun 2023
20 May 2023 - 2 Jun 2023
Amount
Taking down street light fitting any type any wattage from street tubular/PCC Poles/High mast poles of any height incl disconnection of electrical connections repair the same complete in all respect, refixing and reconnection at existing/new position all as specified and directed.(all UNSV accessories shall be replaced under respective items).
Supply and fixing of driver suitable for LED light fitting 15 to 30 Watt complete all as directed.
Supply and fixing of driver suitable for LED light fitting 45/60 Watt. complete all as directed.
Supply and fixing of driver suitable for LED light fitting 90/120 Watt. complete all as directed.
Material and labour for replacement of existing unsv street light fittings with LED street light fitting 45 Watts, IP 66, having pressure die cast alumnium alloy housing with heat resistant toughned glass with individual peanut LED lenses and Driver shall be IP-66 for water protection, including surge protection device 5 KV including making connections with PVC insulated and sheathed three core multi stranded aluminium conductor cable of size 1.5 Sqmm complete all as specified and directed. Make: Havells Cat Ref ENDURASUNDOWNSL45WLED 765PASY BOTG/ Philips Cat Ref BRP409 LED 040 CW HO MR FG S1 PSU GR/ Orient Cat No: LSFC-045-C
Material and labour for replacement of existing unsv street light fittings with LED street light fitting 60 Watts, IP 66, having pressure die cast aluminium alloy housing with heat resistant toughned glass with individual peanut LED lenses and Driver shall be IP-67 for water protection, including surge protection device 5 KV including making connections with PVC insulated and sheathed three core multi stranded aluminium conductor cable of size 1.5 Sqmm complete all as specified and directed. Make: Havells Cat Ref ENDURAOMNIPLUSSL 60W LED757SASY TOPC/ Philips Cat Ref BRP409 LED 060 CW HE NR PC S1 PSU GR/ Orient Cat No: LSFC-060-C
M&L for replacement of existing unsv street light fittings with LED street light fitting 90 Watts, IP 66, having pressure die cast aluminium alloy housing with heat resistant toughned glass with individual peanut LED lenses and Driver shall be IP-67 for water protection, having surge protection device 10 KV, including making connections with PVC insulated and sheathed three core multi stranded aluminium conductor cable of size 1.5 Sqmm complete all as specified and directed. Make: Havells Cat Ref ENDURAPEARLPLUSSL90WLED757PASYTOPCAS TCC/ Philips Cat Ref BRP410 LED 091 CW HE MR PC S2 PSU GR/ Orient Cat No: LSFC-090-C-PC
M&L for replacement of UNSV GI bracket made out of GI pipe 40 mm bore medium grade bent to required shape of 0.90 mtr long and fixing to pole/wall with suitable size of nut, bolts and clamps all as specified and directed. Note :- Taking down and re-fixing of Street light if required shall be the part of this item.
S & F in replacement post top lantern 30/35 Watts, 230 volts, 50 Hz with IP65 protection, mushroom or oval shaped in opal/ prismatic finish made out of polycarbonate, suitable all accessories and prewired complete all as specified and directed. Make:- Havells Cat Ref RUBYPT35WLED830PSYMTOPC/ Orient Cat No: LLOP-30-C or equivalent to Phillips.
S & F in replacement LED bollard of 9/10 watts, 230 volts, 50 Hz with IP 65 protection with robust design and efficient light distribution complete all as specified and directed. Make:- Havells Cat Ref MOUNTBL 10WLED857 PSYMTOPMMA (0.6M)/ Orient Cat No: LLSBL-10-W-B/ Phillips Cat Ref BCP400 LED09 D CW PSU GR S1
M&L for replacement of existing unsv flood light fittings with LED flood light fitting 120 Watts, IP 66, having pressure die cast alumn alloy housing with heat resistant toughned glass with individual LED lenses, having surge protection device 10 KV and Driver shall be IP-67 for water protection, including making connections with PVC insulated and sheathed three core multi stranded alumn conductor cable of size 2.5 Sqmm complete all as specified and directed. Make: Havells Cat Ref JETAIRISFL120WLED757ARWBLTG/ Phillips Cat Ref BVP192 LED110 CW HO NB FG GR PSU/ Orient Cat No: LFAP-120C
M&L for replacement of existing unsv flood light fittings with LED flood light fitting 150 Watts, IP 66, having pressure die cast alumn alloy housing with heat resistant toughned glass with individual LED lenses, having surge protection device 10 KV and Driver shall be IP-67 for water protection, including making connections with PVC insulated and sheathed three core multi stranded alumn conductor cable of size 2.5 Sqmm complete all as specified and directed. Make: Havells Cat Ref JETAIRISFL150WLED757ARNBLTG/ Phillips Cat Ref BVP122 LED150 CW HE NB FG XTFCL S4/ Orient Cat No: LFAP-150C
Excavating in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc or for laying for cables etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any type of soil including removal of sand, bricks/PCC covers laid for cable proection complete all as specified and directed.
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layers not exc. 25 cm in any type of soil complete all as specified and directed.
Removing surplus excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
Supply & laying in replacement of brick, double walled corrugated (DWC) HDPE duct pipe in 6 m lenght conforming to IS 16205 Pt-24 of approved colour complete with fittings for cable protection of size 50 mm inner dia and 63 mm outer dia complete all as directed.
Taking out old unserviceable LT UG cables of size 10 to 70 Sq mm 2/3.5/4 Core from trenches, poles/walls and floor for removing of fault or re-laying (Necessary earth work shall be measured and paid under respective item of sch.) complete all as directed.
Re-Laying XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of 10 to 70 Sqmm 3.5/4 Core (Item retreived from item 17 here-in-before) laid in trenches or fixed on wall/floor/poles after removing fault complete all as specified and directed.
S&L XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 50 Sq mm 3.5 core laid in trenches or fixed on wall/floor/poles complete all as specified and directed.
All as per Srl Item No 19 here-in-before but size of cable 35 Sqmm 3.5 Core complete all as specified and directed.
All as per Srl Item No 19 here-in-before but size of cable 25 Sqmm 3.5 Core complete all as specified and directed.
All as per Srl Item No 19 here-in-before but size of cable 16 Sqmm, 4 Core complete all as specified and directed.
All as per item No 19 here in before but size 10 Sqmm 4 core complete all as specified and directed.
Material and labour for replacement of GI tubing light grade 40 mm bore for passing through cables laid under the floor, along the wall or along the pole complete all as specified and directed .
Material and labour for replacement of GI tubing light grade 50 mm bore for passing through cables laid under the floor, along the wall or along the pole complete all as specified and directed .
Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP – 31), 09 meter long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be painted with two coats of aluminum paint from 1.5 mtr above ground level to top of pole and a height of 1.5 mtr from the ground level synethetic enamel paint in alternate strips / layer (30 cm wide) with white and blue colour including writing the pole number in white letters on black background including taking out old unsv pole complete all as specified and directed.
M&L for PCC 1:4:8 type D2 ( using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M&L for PCC1:3:6 Type C2 (using 40mm graded stone aggregate) as in coping of poles etc. complete all as specified and directed.
Trimming up of tree branches upto 3 mtr all around overhead line, removing cut branches from site as directed. Note :- (i) The overhead lines will be kept clear from all trees by trimming of tree branches with 3 mtr all around the line. (ii) Necessary permission will be obtained from department by contractor one day prior to trimming in particular area and shut down of that area will be arranged by department.
M&L for prepration of old painted surface of steel tubular poles of 9 mtr long including cross arms, cable protection pipe, bus bar box and painting of complete area with one coat of aluminum paint from 1.5 mtr above ground level to top of pole and a height of 1.5 mtr from the ground level synethetic enamel paint in alternate strips / layer (30 cm wide) with white and blue colour including writing the pole number in white letters on black background and cleaning /cutting the grass/bushes at a radius of 2 mtr surrounding the pole all as directed.
M&L in replacement of existing unsv MCCB 160 Amps current carrying capacity 25 KA , AC 415 Volts four pole with magnetic/ thermal fixed setting complete all as specified and directed.
M&L in replacement of existing unsv MCCB 125 Amps current carrying capacity 16 KA , AC 415 Volts four pole with magnetic/ thermal fixed setting complete all as specified and directed.
M&L in replacement of existing unsv fixed type MCCB with MCCB 63 amps, 4 pole, 415 volts, 16 KA complete all as specified and directed.
Supply and fixing in replacment nature switch complete with timer, contactor, relays and suitable rating MCBs for incoming and out going in built in suitable IP 66 enclosure (Hensel) of three phase integrated models of capacity 8 KW complete all as specified and directed.
All as per item No. 34 above but of single phase integrated models of capacity 8 KW
Supply and fixing thermoplastic polystyrene /polycarbonate enclosure bus bar chamber, shock proof, vermin proof and dust proof complete with 04 Nos aluminium strip of capacity 100 Amps including non metalic clamps and GI nut bolts and washers of suitable size and fixed on pole / wall complete all as specified and directed.
S&F in replacement Weather proof thermo (Polysterene) cable junction box, having protection class IP-66 and overall minimum size 155 x 210 x 92 mm having metric knockouts on the wall, dully fixed on the pole with aluminium strip 25 x 3 mm clamp, GI bolts, nuts, washers and 2 Nos. polymide weather proof cable glands of cable sealing range 10 mm to 17 mm (complete with check nut) and including 1 No 30 Amps with cable connector and 1 No. 0.50 Amps MCB SP complete all as specified and directed. Make :- Hensel Cat Part No. DK 1616 G or equivalent in ABB/ Seimens
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth pit not less than 3.25 mtr deep below the normal ground level) with top edge of plate not less than 2.5 mtr below the normal ground level connected to galvanized earth strip 32X6mm thick by means of nuts, bolts, washers and check nuts of galvanised iron or steel and welding full length of strip with earth plate, 40 mm bore GI pipe light grade proection pipe up to test point, 20mm dia light grade GI pipe for watering, meshed funnel, alternate layer of charcoal and common salt complete all as per SSR with PCC chamber, 50mm thick RCC cover in 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8mm dia TMT bar @ 80mm c/c both way in lieu of CI pit cover and protection including necessary excavation and earth work complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth pit not less than 3.25 mtr deep below the normal ground level) with top edge of plate not less than 2.5 mtr below the normal ground level connected to galvanized earth wire 4 mm dia by means of nuts, bolts, washers and check nuts of galvanised iron or steel and welding full length of strip with earth plate, 40 mm bore GI pipe light grade proection pipe up to test point, 20 mm dia light grade GI pipe for watering, meshed funnel, alternate layer of charcoal and common salt complete all as per SSR with PCC chamber, 50mm thick RCC cover in 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8mm dia TMT bar @ 80mm c/c both way in lieu of CI pit cover and protection including necessary excavation and earth work complete all as specified and directed.
S&F in replacement timer switch, 16 A, 240 Volts, single phase complete all as specified and directed. Make:- Havells cat part No. DHTMNX5016 or equivalent in Siemens/L&T/ Legrand
M&L for making service connection from MCB DB to LED flood light fitting of high mast with PVC sheathed 1.5 Sqmm five core multi-stranded copper conductor cable of required length complete all as specified and directed.
M&L for drilling suitable dia horizontal bore holes for insertion / laying of up to 50 mm bore GI tubing/HDPE pipe of any description below/under road surface/floors etc. with using mechanical or manual devices as required at site including making good disturbed surface to match with the existing streta after laying pipes complete all as specified and directed.
S&F in repair MCB single pole 240 volts, 'C' curve of rating 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
S&F in repair MCB SPN 240 volts, 'C' curve of rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
S&F in repair flexible wire three core, PVC insulated 1.5 Sqmm multi stranded copper conductor, 1100 V grade for making connections from pole to street/flood lights complete all as specified and directed.
M & L in replacement Bus Bar Panel of capacity 100 Amps copper bus bar 04 Nos, four way with fixed on insulator including fixed on pole with bracket made out of FI of size 25x3 mm -02Nos including providing new nut, bolt & washers all as specified and directed. Make : Havells Cat Part No IHBC010004 or equivalent in Legrand/L&T.
M&L for replacement of existing unsv cable end terminal joints with new cable end terminal joints (heat shrinkable) with long sleeve minimum 0.50 m, any type along Pole/panel etc. suitable for XLPE LT 1100 Volts aluminium conductor cable of size 16-35 Sqmm 3.5 core and testing after jointing. Note:- Rate quoted including necessary excavation, returning filling, removal etc for taking out loop/ cutting of burnt cable for required length for making end joint.
All as per item No. 47 but for cable size 10 Sqmm 2/4 core
Cutting the existing road/ Hard standing minimum depth 60 cm and minimum width 45 cm for passing pipe/ cable and making good the disturbed surfaces by using 15 mm thick 1:4:8 in foundation type D-1 (using 20mm graded crushed stone aggregate) as in mass concrete complete all as specified exists complete all as specified.
M&L for locating and repairing street light feeder fault (OH lines or UG cables) such as short circuiting, snapping of conductors, phase/ neutral loss in UG cables etc. and making the defective circuit serviceable in all respects complete all as directed. Note:- (a) Repairing of fault in one circuit, irrespective of any number of street lights/ poles/ junction boxes etc at any location shall be treated as one job. (b) Earth work, if required shall be measured and paid separately under respective item. (c) All type of T&P, PVC insulation tape, minor nuts/bolts/washers/ thimble/lugs etc. required shall be provided by the contractor without any extra cost to the Govt. (d) Any loose/ broken overhead conductor shall be restringed/ repaired to make the system functional in all respects and unit rate quoted shall deemed to include the cost of the same.
M&L for disconnecting of burnt/damaged cables from panels/ junction boxes etc. cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tapes etc. and reconnecting using new nuts/bolts/washers/ thimble/lugs etc. and restoring three phase and neutral connection in the junction box for 10/16/25 Sqmm 2/3.5/4 core size LT underground cable complete all as specified and directed. Note:- Earth work required for extending the incoming/outgoing cable in junction box/ panel etc. shall deemed to be included in unit rates.
M& L for numbering of street light poles of any type by painting 150 mm dia base with enameled paint of approved colour and writing pole No with white enameled Paint complete all as specified.
M & L for repairing of existing damaged earth pit by casting new earth pit chamber using PCC (1:3:6) type C-1 and RCC(1:2:4) type B-1 pit cover 50 mm thickness using 8 mm dia bars 100 mm c/c complete all as shown in electrical plate No 3 of SSR part-I and all as directed.
Labour of taking down the high mast light bracket of 16/21 m high pole and cleaning of motor, gear box chamber and greasing of chain and other movable part and re-fixing in same position after the repair complete all as specified and directed. Note:- Copper cable/ gear box chamber replaced shall be paid separately under respective item as supply only.
Supply only stainless steel rope high mast light 5 to 7 mm dia. complete all as directed.
Supply only gear box set suitable for high mast light complete as per existing shape, size and make and all as directed.
M&L for electric / gas welding in panel / pole/ any other work complete all as specified and directed.
Dismantling of cross arms of MS channel or angle iron section with clamps etc. and supply and fixing Cross arms, bracing supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as directed.
M&L for replacement of existing unsv street light fittings with LED street light fitting 36 Watts with dusk dawn sensor, automatic switch on and switch off operation based on ambient lux lavels, having cast alumn housing, polycarbonate diffuser, secondary optical lance, IP 65, including making connections complete all as specified and directed. Make: Orient Cat Ref LSFT 036C -DLS or equivalent to Phillips / Wipro / Havells
S&L/ fixing in replacement of unsv 1100 volts grade, 16 core 2.5 Sqmm PVC insulated and PVC round sheathed multicore bright annealed bare copper conductor cable as per IS:694/1990 complete all as specified and directed .
All as per Srl Item No 60 here-in-before but size of cable 2.5 Sqmm 4 Core complete all as specified and directed.
All as per Srl Item No 60 here-in-before but size of cable 2.5 Sqmm 2 Core complete all as specified and directed.
Dsmantling of existing light and Supply and fixing of Lithium based Energy Efficient integrated Solar street light of 40 Watt in single FRP body with duly polylurethane coating, encases with Monocrystalline solar PV Panel of 64/66 Wp, litium battery 11.1/12.8 V, 36.0 AH with inbuilt BMS, IP65 high brightness W LED 160-180Lm/watt) lamp with Aluminium reflector, CRI>70, Colour Tempeture 5700K-6500K micro controller based charge controller cum driver automatic dimming function(First four hours at full brightness & rest at lower light level with PIR motion sensor), dust to dawn operation suitable to working tempreture -100 C to +550 C, weight more than 6-18 Kg with suitable size of GI bend pipe, adjustable MS clamp suitable for pole/wall mounting etc complete all as specified and directed. Make - Cat part no.- Axxon -AXN-40 watt of Xxxon Tech Industries./ Orient /Okaya Power Pvt Ltd / Havells
Balaji Associate
Unnati Engineers
M/s Sumer Associates
GUPTA ENGINEERING WORKS
CHAHAR CONTRACTOR AND SUPPLIERS
m/s Agra Builder
M/S Mamta Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .