Tender Value
₹15.4 Cr
EMD Value
₹9.2 L
Closing Date
23 Feb 2026, 3:00 pmClosed
Yes (up to 3 members)
No
Two Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
SOUTH
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N OR 'V' Whichever is less; where. V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per ANNEXURE-XXXIII, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- "Work of Supply, Installation & Commissioning Of DAC." OR "Any Signalling work involving Supply, Installation & Commissioning of DAC."
7 conditions
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tender document, Scope of work & GCC 2022 are attached with the tender.
Replacement of overaged AFTCs at Bhandup, Mulund and Parsik stations and Mid life rehabilitation of Axle counters in Mumbai division of Central Railway.
CR-BB-SnT-SOUTH-2026-08
CR-BB-SnT-SOUTH-2026-08
Open
Works - General
12 Months
Mumbai, Maharashtra
₹0
₹9.2 L
23 Feb 2026
23 Jan 2026
147 items across 6 schedules · ₹9,00,42,393.93 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Supply of Relay Rack Assembly complete with scaffolding, fixtures and accessories including MS Bars for fixing of relay plug board, string rods, fuse strips with bracket, 11 Way Bus Bars with cover and mounting brackets, runway for cable/wires, frame, base assembly etc. Siemens type & as per extant practice on C. Rly. Typical part list as per Annexure- and Rack arrangement as per Sketch no SK-727 and Rack plan as approved by Engineer in charge. (Inspection Agency-Consignee) | Set | 3.00 | 33,949.01 | 1,01,847.03 |
| 2 | Supply of Tag Blocks 200/160/120 way with polycarbonate cover as per IRS S 77-2006(Rev.1) RDSO DRG. No. SA 24751, SA 24752 & SA 24753. Requirement of each type shall be specified by Engineer-in-charge. (Inspection Agency-RDSO) | Numbers | 10.00 | 1,360.69 | 13,606.9 |
| 3 | Supply of Indoor Jumper Wire of various colour as per Railways standard practice of type ATC 1 x 0.6 mm dia.conforming to IRS 76/89 (Amd.3) or latest. (Inspection Agency-Consignee) | Kilometre | 19.00 | 8,316.5 | 1,58,013.5 |
| 4 | Supply of PVC flexible copper cable single core multistrand 1 x 16 Sq.mm (126 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS:694/2010 with latest amendment if any with insulation thickness of 1.0mm nominal conductor resistance 1.121 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3). (Inspection Agency- Consignee) | Kilometre | 1.00 | 2,01,888.05 | 2,01,888.05 |
| 5 | Supply of PVC flexible copper cable single core multistrand 1 x 25 Sq.mm (196 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS:694/2010 with latest amendment if any with insulation thickness of 1.2mm nominal conductor resistance 0.780 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3). (Inspection Agency- Consignee) | Kilometre | 1.00 | 3,13,722.38 | 3,13,722.38 |
| 6 | Supply of wire 16/0.2 (Blue, Red, Grey, yellow, Brown, Black, White as per site engineer instruction) finolex/polycab/delton make. IRS S-76/89 (Amd.3), BS: 4808 Part-2. Wire to be procured from RDSO approved vender. (Inspection Agency-Consignee) | Kilometre | 10.00 | 6,198.32 | 61,983.2 |
| 7 | Supply of Program switches with acrylic cover, snap action, base mounting type along with cover and mounting bracket 25A-7 pole 3 position Siemens type (3 LAO-25/7Y) / L&T/HAVELLS type. Drg. No. RST.C.106 (Inspection Agency-Consignee) | Numbers | 3.00 | 7,131.88 | 21,395.64 |
| 8 | Supply of Battery Charger self regulating floor mounting type with 230 V AC single phase input and output 24V DC, 30A as per spec. IRS.S.86/2000 (Amd.1) with latest amendments for Axle counter applications (Amd.4). (Inspection Agency-Consignee) | Numbers | 3.00 | 57,432.14 | 1,72,296.42 |
| 9 | Supply of Plug In type Relay Metal to Metal type neutral relay mini groups (AC Immunised-1) Siemens make (No. RSSK 30/0078-1) (Ref. IRS:S46/74 with Amd. 1 & firms specification).or functional equivalent without base plates.Contact configuration 5F/3B or 6F/2B or 4F/4B to be specified by Engineer incharge. (Inspection Agency-RDSO) | Numbers | 40.00 | 8,354.16 | 3,34,166.4 |
| 10 | Lacing thread rolls, black, wax coated (100 mtrs). (Inspection Agency-Consignee) | Numbers | 20.00 | 63.61 | 1,272.2 |
| 11 | Supply of ARA Terminal blocks with links made of PBT Specn No.IRS/75/2006(Rev-2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4, SA-23745 Alt.5, SA-23746, SA-23748 Alt.4 & SA-23756A Alt.3. (Inspection Agency-RDSO) | Numbers | 1000.00 | 69.83 | 69,830 |
| 12 | Supply of Track Lead Juction Boxes as per C.Rly Drg. No.RST 11509 made from fiiber glass alongwith terminal blocks. (Inspection Agency-Consignee) | Numbers | 30.00 | 1,007.84 | 30,235.2 |
| 13 | Supply of B type choke to specn.No.IRS.S.65/83 (Amd.3) with latest amendments. (Inspection Agency- RDSO) | Numbers | 60.00 | 3,525.92 | 2,11,555.2 |
| 14 | Supply of adjustable Track Feed Resistance disc type 7.5/15/30 ohms as per RDSO Drg. No. SA 20161-66/M (Adv) with latest amendments (with Phenolic moulded base). (Inspection Agency-RDSO) | Numbers | 60.00 | 1,238.8 | 74,328 |
| 15 | Supply of Track feed battery chargers, 110V AC input 2, 4 to 6 V DC Output to Specn.No.IRS.89/2013 Ver.1.0 with latest amendments. Charger shall be suitable for charging 80 AH battery. (Inspection Agency- Consignee) | Numbers | 30.00 | 2,337.21 | 70,116.3 |
| 16 | Supply of Channel Pins single groove, galvanised, 7 m m suitable for 4mm dia bonding wire as per spec No. IRS: S 17-75 Revision 3. (Inspection Agency- Consignee) | Numbers | 200.00 | 1.93 | 386 |
| 17 | Supply of PVC jacketed wire rope for Track Lead connections. PVC jacketed wire rope should be of Galvanised steel wire rope 6 mm dia (6x19 stranded wire with steel core of 6 mm dia) sheathed with PVC 2mm wall thickness, overall thickness being 10 mm. PVC sheath should be made of type 6 compound as per IS 5831 of 1984 Reaffirmed 2001 and steel wire rope as per IS: 2266:2019. Reclaimed or recycled material should not be used. (Inspection Agency- Consignee) | Metre | 1000.00 | 50.29 | 50,290 |
| 18 | Supply of 8 SWG GI wire (4mm dia) suitable for track circuit rail bonding. As per IRS Specification S:13 -62 (Inspection Agency-Consignee) | Kg | 100.00 | 83.49 | 8,349 |
| 19 | 'Supply of Hydrometer, Exide make or similar for measuring specific gravity of Battery Graded acid with mounting stand in location Boxes.Consignee inspection under manufacturer certificate. (Inspection Agency-Consignee) | Numbers | 10.00 | 272.77 | 2,727.7 |
| 20 | Supply of Electronic Timers for DAC reset arrangement 3 sec to 30 sec with 2NO/2NC contact working voltage 24V/60V DC. Siemens/ABB/L&T or SELEC (642XA programmable electronic timer switch) make. (Inspection Agency-Consignee) | Numbers | 150.00 | 2,711.3 | 4,06,695 |
| 21 | Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239 PT. 1/2004 or latest with sockets and fittings. TATA/JINDAL/ZENITH BIRLA make. (Inspection Agency-Consignee) | Metre | 150.00 | 989.89 | 1,48,483.5 |
| 22 | Supply of DWC HDPE pipe with one snap fit coupler and 'O' ring fire resistant, anti rodent, in 6 meter length of size 120 mm outer dia as per RDSO/SPN/204/2011 Ver. 1.1 with Amd.1 or latest. (Inspection Agency-Consignee) | Metre | 360.00 | 309.12 | 1,11,283.2 |
| 23 | Supply of Modular terminal block of 2.5 sq.mm 2 in 2 out type disconnect type terminal along with as per RDSO/SPN/189/2004 Rev 3.0. The current capacity of 16 Amps and more. The terminal should have marking at centre to view description from front. Material to be procured from RDSO approved firms only. (Inspection Agency-RDSO) | Numbers | 1000.00 | 112.63 | 1,12,630 |
| Schedule total | ₹26,77,100.82 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
FINALNEWTENDERDOC2026-08.pdf
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY.pdf
CORRECTIONSLIP1GCC2022.pdf
CORRECTIONSLIP2GCC2022.pdf
CORRECTIONSLIP3GCC2022.pdf
CORRECTIONSLIP4GCC2022.pdf
CORRECTIONSLIP5GCC2022.pdf
CORRECTIONSLIP6GCC2022.pdf
CORRECTIONSLIP7GCC2022.pdf
CORRECTIONSLIP8GCC2022.pdf
CORRECTIONSLIP9GCC2022.pdf
CORRECTIONSLIP10GCC2022.pdf
CHECKLISTFORST.pdf
FINALNEWTENDERDOC2026-08.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .