RequiredOEM Authorization Certificate Bid to RA enabled No X-Ray Machine (500 MA) ( 1 pieces ) ( Under PAC ) Make genuine Model gxld500 Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Standards Conformity to Certification CDSCO/AERB * Certification number and date GJ-23740-MF-XRE-001 05/03/2019 * Type test approval Yes * 1/7 from AREB required AREB approval certificate number of Particular Model 16-TA-91939 * Confirmity to manufacturing standards ISO 13485 * Conformity to safety standards IEC 60601-2-54 or BIS equivalents * Performance Parameters Purpose For Radiography examinations * Type of Frequency generator High frequency generator High frequency generator Frequency generator output in kW 40 * KVP range in KV 40 -125 * Current output 500 mA or more at 100 kV * Provision of Anatomical programming radiography Yes Yes Over loading protection Yes * X-ray tube positioning Floor Mount Tube stand * X ray tube should be high speed rotating anode and must have dual focus Yes * Tube rotation in degree 120 * Size of large focal spot in mm Upto 2 mm * Size of small focal spot in mm Upto 1 mm * Anode Rotation Speed (minimal) per minute 2800 * Permanent Filtration 0.9 mm Al/75 kV * Anode heat storage capacity 300 * Heat dissipation rate 1000 * Automatic exposure control device provided Yes * Maximum Exposure time in milli second upto 15 upto 15 Digital display for KVP & mAs provided Yes * 2/7 Range of tube movements in vertical planes in cm 150 * Range of tube movements in longitudinal in cm 150 * Range of tube movements in lateral planes in cm 150 * Electromagnetic brakes with fully counter balanced mechanism for tube movement Yes * Facility to display tube angulation Yes * Centering devices to be provided Yes * Maximum source to image distance (SID) in vertical position in cm 150 * Maximum source to image distance (SID) in horizontal position in cm 100 * Collimeter rotation in degree ±180 * Multileaf collimator having halogen lamp/bright light source
Requiredwith auto shut off provision of the light
Requiredshould be available Yes * Minimum intensity of light field lamp ≥150 lux ≥150 lux Full coverage size at a 100 cm SID(collimeter size) with ± 5 percent tolerances 430 x 430 * Type of table provided Floating table top * Table top material with low attenuation and scratch resistant surface Melamine Melamine Table Length in mm with ± 1 percent tolerances 1800 * Table Width in mm with ± 1 percent tolerances 600 * 3/7 Table Height in mm with ± 1 percent tolerances 650 * System should have longitudinal and horizontal table top movements Yes * Table should have provision for lateral imaging
Requiredwithout patient movement No Yes
RequiredNo Range of movements for the table Transverse movements of + 10cm or more & Longitudinal movements+ 40 cm with electromagnetic brakes * Facilities of height adjustments Yes Yes Maximum Patient weight supported by table in kgs 200 * Foot switches for adjusting longitudinal/side to side movements
Requiredlocking
Requiredand light adjustment No Yes
RequiredNo Movable Grid with grid ratio 10:1 or more * Anti-collision and safety devices provided Yes Yes Counterbalanced
Requiredadjustable height
Requiredwall and floor mounted
Requiredvertical Bucky Yes * SID range of radiographic application including chest radiography in mm 1000 to 1800 * Provision of doing chest radiography without grid Yes Yes Power supply Three Phase AC ( 380-440 V
Required50/60 Hz) * Number of installations of the X- ray machines in >3 <3
Required>3 4/7 Central/State/PSU Govt Hospitals (Note: Seller should furnish a performance certificate of the device to the buyer in case demanded after placement of the order) OEM and Reseller (if supplier is re-seller) shall ensure uninterrupted availability of all spares for 10 years Yes * Availability of toll free facility for technical support maintened by OEM or authorized agencies Yes Yes User/Technical/Mainten ance manuals to be supplied in English in hard and soft copy Yes * Demonstration of equipment and training to be provided after completing supplies before acceptance Yes * Warranty in years 5 * Additional Parameters Patient fixing belts and compression device (for performing excretory urography
Requiredetc) Yes Yes Voltage stabilizer servo controlled in kVA 50 * Lead lining for doors Yes * Lead Aprons - Full body and Skirt type (Each ) 2 each (0.5pb) * Light weight zero lead radiation protection aprons provided Yes Yes Thyroid shields supplied 4 * Gonad sheet Male supplied 2 * 5/7 Gonad sheet Female supplied 2 * Wall mounted stand for radiation protection aprons supplied Yes * Lead glass window Supplied Yes * Footsteps for the table supplied Yes * Lateral cassette holder provided No Yes
RequiredNo Reports The Principal Manufacturer must have direct Presence/approved service center In India Yes * Copies of reports and certifications to be furnished to buyer on demand at time of supplies Yes * QA
RequiredQC and other tests as per NABH shall be carried out by OEM or authorized agency of OEM Yes * Copies of all calibration and test reports to be submitted at the time of Supply of Machine Yes * * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.