Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | ₹10.4 L Quoted ₹12.4 L | L1 | Accepted-AOC Accepted due to lowest rate quoted |
| 2 | L2₹16.7 L+₹4.3 L (34.5%)Rejected-Finance RZ 50D GALI NO 13 VASHISHT PARK PANKHA ROAD NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | ₹16.7 L+₹4.3 L (34.5%) | L2 | Rejected-Finance Rejected due to highest rate quoted. |
| 3 | L3₹16.8 L+₹4.4 L (35.0%)Rejected-Finance | ₹16.8 L+₹4.4 L (35.0%) | L3 | Rejected-Finance Rejected due to highest rate quoted. |
| 4 | L4₹21.4 L+₹8.9 L (71.9%)Rejected-Finance RZ 1 7 167 GALI NO 6 DURGA PARK NASIRPUR SOUTH WEST DELHI DELHI 110045 | SOUTH WEST | DELHI | 110045 | ₹21.4 L+₹8.9 L (71.9%) | L4 | Rejected-Finance Rejected due to highest rate quoted. |
| 5 | L5₹23.6 L+₹11.2 L (90.0%)Rejected-Finance N A | NEW DELHI | DELHI | 110001 | ₹23.6 L+₹11.2 L (90.0%) | L5 | Rejected-Finance Rejected due to highest rate quoted. |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
18 Oct 2024, 6:00 pmClosed
GE (AF) GURGAON
GE (AF) GURGAON
REPAIR/MAINTENANCE AND IMPROVEMENT/DEVELOPMENT OF BOREWELL REWINDING OF SUBMERSIBLE PUMP/CENTRIFUGAL PUMP SETS MOTOR STARTER AND ALLIED WORKS AT AF STN GURGAON UNDER AGE E/M (AF) GURGAON
2024_MES_675646_1
GE/GUR-/NIT-29/2024-25
Open Tender
Civil Works
Item Rate
240 days
GE (AF) GURGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) GURGAON
₹60,000
9 Nov 2024
20 Sept 2024
21 Oct 2024
20 Sept 2024
18 Oct 2024
4 Oct 2024
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 m depth and n.exc 1.5 m wide for laying of pipes/cables etc and getting out complete all as specified and as directed.
M & L for Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and as directed.
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
Taking up or down CI Pipes including all fittings such as spigot and socket ends, bends, belows tee etc laid complete in trenches all as specififed of sizes :-
(a) 80mm bore.
(b) 100mm bore.
(c ) 150mm bore.
(d) 200mm bore .
Taking up or down DI water mains pipes including all fittings with spigot and socket ends and rubber tytan joints including removing out joints complete in trenches all as specified and directed of sizes :-.
(a) 100mm bore.
(b ) 150mm bore.
Supply, Laying and Testing of cast iron pipes with spigot and socket ends and centrifugally cast class LA, in any length, laid in trenches complete all as specified and directed of following sizes :-
(a) 80mm bore .
(b) 100mm bore .
(c ) 150mm bore .
(d) 200mm bore .
Supply, Laying and Testing of DI water mains pipes including all fittings with spigot and socket ends and rubber tytan joints Class K9 in any length laid in trenches complete all as specified and directed of following size:-
(a) 100mm bore.
(b ) 200mm bore.
Taking up or down steel tubing and connections including all fittings such as bends, belows tee, unions, sockets etc laid complete in trenches all as specififed of sizes :-
(a) 15mm bore .
(b) 20mm bore .
(c ) 25mm bore .
(d) 40mm bore .
(e) 50mm bore .
(f) 80mm bore .
(g) 100mm bore .
S & F in repair steel tubing and connections including all fittings such as bends, belows tee, unions, sockets etc laid complete in trenches all as specififed of sizes :-
(a) 15mm bore .
(b) 20mm bore .
(c ) 25mm bore .
(d) 40mm bore .
(e) 50mm bore .
(f) 80mm bore .
(g) 100mm bore .
S & F in replacement Gun metal Gate valve with iron wheel head screwed both ends complete all as specified and as directed by the Engineer-in-Charge of sizes :-
(a) 40 mm dia .
(b) 50 mm dia.
(c ) 20 mm dia .
(d) 25 mm dia .
S & F check valve heavy duty of gun metal both end threaded and leaf spring loaded vertical type including removing unserviceable foot valve from the suction pipe of the pump set complete all as specified and directed by Engr in charge of following sizes :-
(a) 100 mm dia.
(b) 80 mmm dia.
(c) 50 mm dia.
S & F in replacement CI non return valve complete all as specified and directed by Engr in charge of following sizes :- .
a) 150 mm dia.
b) 100 mm dia.
c ) 80 mmm dia.
d) 50 mm dia.
M & L for Cutting existing CI or steel tubing of any size for alterations or additions and screwing complete all as specified and as directed.
Demolition of existing valve pit and M&L for construction of valve pit consisisting of 230mm thick, old size brick masonry wall in cement mortar (1:6), PCC (1:4:8) type D2, using 40mm graded stone aggregete as in fondation, PCC (1:2:4) type B1, using 20mm graded stone aggregete in coping/bed, finished even and smooth, rendering 15mm thick in cement mortar (1:6) internally and 10mm thick in cement mortar (1:4) externally, finished even and smooth without using extra cement incuding three coats of white wash and earth work in any type of soil and including 3mm thick MS sheet cover fixed on 40mmx40mmx6mm thick angle iron frame ambeded in PCC coping with locking arrangement and mild steel hold fast & handle and duly painted with two coats of synthetic enamel paint over one coat of primer etc. complete all as shown on drawing NO TD/2004/26 Sh 1/1 to 1/3 and as specified and directed for the following sizes:-
(a) 900mm x 750mm x 900mm.
(b) 900mm x 600mm x 1000mm.
S & F in replacement Cast Iron sluice valve, class PN- 1.6 with flanged and drilled ends any pattern including necessary jointing and jointing materials complete (with rubber gaskets, bolts and nuts etc) complete all as specified and directed by Engr in charge including taking down the old worn out sluice valve complete all as specified and directed by Engr in charge for the following sizes :-
(a) 150 mm dia.
(b) 100 mm dia.
(c ) 80 mm dia.
Supply only high strength Calcium Hypochlorite based granular chlorination chemical having 60% to 70% available chlorine granuler must contain appropriate quantities of disinfectants/corrosion inhibitors to prevent encrustation/scaling in distribution, packed in 40/45 Kg plastic Drum complete all as specified and as directed.
Supply only high strength TCC 90 based granular chlorination chemical having >90% available chlorine granuler must contain appropriate quantities of disinfectants/corrosion inhibitors to prevent encrustation/scaling in distribution, packed in 40/45/50 Kg plastic Drum complete all as specified and as directed.
M&L for CI fittings for flanged pipes upto 150 mm bore ,bends ,cross Tee any type any radius and straight connecting pieces complete complete all as specified and as directed.
Lifting and lowering submirsible pump moter with the help of machine/ hydra/chain pully block with sufficent manpower including taking submersible cable dismentling and reconnectioing the pipe line including replacement of worn out/ rusted/old nuts & bolts, gasket with new proper size . Job includes cutting, welding any rusted pipe and flanges for safe working of submersible pump with motor of capacity UPTO 25 HP complete all as specified and as directed. Note:- During lifting/lowering of pump motor from borewell if falls in the borewell then contractor will arrange to take out the pump motor without any extra cost.
M&L for servicing submersible pump to make the pump functional, Servicing of defective submersible pump of following capacity by dismantling the pump & removing unserviceable parts and assemble the pump properly after replacements of unserviceable parts complete all as specified and as directed of the following capacity:- Note:- (a) The quoted rates are inclusive of transporting the pump from bore well site to repair work shop & back to site. (b) The quoted rates are inclusive of any spare required including seal, bearing/bush of pump to make the pump functional irrespective of item in this schedule.
(a) For motor of capacity 25 HP.
(b) For motor of capacity 15 HP.
(c) For motor of capacity 12.5 HP.
(d) For motor of capacity 10 HP.
M&L for Servicing of Submersible motor by taking out copper winding, cleaning the casing & slots with wire brush & washing with pressure water & shall be dried. Making the winding leak proof & taking out the electric connection with suitable size of submersible cable for the pump of following capacity complete all as specified and as directed :-
(a) For submerible motor of capacity 25 HP.
(b) For submerible motor of capacity 15 HP.
(c) For submerible motor of capacity 12.5 HP.
(d) For submerible motor of capacity 10 HP.
M&L for servicing of Centrifugal pump set by disconnecting, dismantling the three phase induction motor 415 Volts 50 Hz of centrifugal pumpset 1440 RPM and winding the same with super enamelled copper wire of best quality of existing size/gauge and weight including replacement of insulation material, varnish,bearing, connection plate and all other petty items like Shaft sleeve DE/NDE made of Bronze, casing wear ring DE/NDE made of Stainless steel, Bearings as per sample etc required to make motor functional and re-assembling the motor including installation, commissioning and testing on full load complete all as specified and as directed. Notes :- (a) Transportation charges from installation to contractor's workshop and back after repair are deemed included in the rate quoted in the item. (b) Cost of nuts, bolts, washers, connection plate, grease lubrication to bearing bushes etc are deemed included in this rate. (c) Old dismantled winding wire will be contractor’s property for which credit shall be affected as per schedule of credit.
(a) For motor of capacity 60 HP.
(b) For motor of capacity 40 HP.
(c) For motor of capacity 20 HP.
(d) For motor of capacity 7.5 HP.
(e) For motor of capacity 5 HP.
(f) For motor of capacity 3 HP.
(g) For motor of capacity 2 HP.
Disconnecting, dismantling of Centrifugal monoblock pumpset of capacity as following of 1440 RPM and dismantling of defective parts such as Impeller nut , gland , impeller key, gland packing, water deflector, bush bearing sleeve, gaskets, volute stud and nuts , suction and delivery flange and stud and nuts, gland bolts and nuts Gun metal impeller etc and all other petty items like split gland made of Cast Iron, set of gasket made of asbestos, gland packing, coupling of suitable size for motor etc required to make pump functional and re-assembling the pump with motor including installation , commission and testing on full load complete all as specified and as directed. Notes:- (i) Transportation charges from installation to contractor work shop and back after repair are deemed included in the rate quoted for the above item. (ii) Cost of nuts, bolts, washers,, grease lubrication to bearing bushes etc are deemed included in this rate :-
(a) For motor of capacity 60 HP.
(b) For motor of capacity 40 HP.
(c) For motor of capacity 20 HP.
(d) For motor of capacity 7.5 HP.
(e) For motor of capacity 5 HP.
(f) For motor of capacity 3 HP.
(g) For motor of capacity 2 HP.
Supply and fixing in replacement of flat submersible 3 core 10 Sqmm cable PVC insulated unsheathed multistranded copper conductor water proof suitable for submersible pump set complete all as specified and as directed.
Supply and fixing in replacement of flat submersible 3 core 6 Sqmm cable PVC insulated unsheathed multistranded copper conductor water proof suitable for submersible pump set complete all as specified and as directed.
Supply and fixing in replacement of flat submersible 3 core 4 Sqmm cable PVC insulated unsheathed multistranded copper conductor water proof suitable for submersible pump set complete all as specified and as directed.
S & F in replacement GI Coloumn pipe of bore 50 mm and 6 meter length with socket/flange of size 50 mm dia and 5 mm thick duly screwed as well as welded on both ends , lowering and fixing into the borewell by using nuts, bolts , gasket and washers complete all as specified and as directed. Note:- Cost of welding of flange nuts,bolts & gasket is included in the unit rate.
S & F in replacement GI Coloumn pipe of bore 80 mm and 6 meter length with socket of size 80 mm dia 6 mm thick duly screwed as well as welded on both ends , lowering and fixing into the borewell by using nuts, bolts , gasket and washers complete all as specified and as directed.
Supply and fixing in replacement of fully automatic star delta starter suitable for 15 HP summersible/monoblock pump motor set AC 440V 50 Hz with single phase priventor over current, short circuit protection built in voltmeter, ammeter complete with sheet metal enclosure including fixing/mounting as per L&T Cat No MU-15 (SS9985) and dismentling old unservicable complete all as specified and as directed.
Supply and fixing in replacement of fully automatic star delta starter suitable for 25 HP summersible/monoblock pump motor set AC 440V 50 Hz with single phase priventor over current, short circuit protection built in voltmeter, ammeter complete with sheet metal enclosure including fixing/mounting and dismentling old unservicable complete all as specified and as directed.
Disconnecting/removing the old unserviceable burnt parts from the FASD starters and supply and fix the new items as per exiting the model for AC 415 V,50 HZ 3 phase suitlable for lthe motors complete all as specified and as directed of the following capacity:-
(a) Power Contactor MNX-25 with Aux contacts 1 NO + 21NC of range AC1 - 45 A & AC3 - 25 A complete all as specified and as directed.
(b) Power Contactor MNX-40 with Aux contacts 1 NO + 1 NC of range AC1 - 55 A & AC3 - 40 A complete all as specified and as directed.
(c) Power Contactor MNX-45 with Aux contacts 2 NO + 2 NC of range AC1 - 80 A & AC3 - 45 A complete all as specified and as directed.
(d) Power Contactor MNX-50 with Aux contacts 2 NO + 2 NC of range AC1 - 80 A & AC3 - 50 A complete all as specified and as directed.
(e) Power Contactor MNX-70 with Aux contacts 2 NO + 2 NC of range AC1 - 70 A & AC3 - 100 A complete all as specified and as directed.
(f) Power Contactor MNX-80 with Aux contacts 2 NO + 2 NC of range AC1 - 80 A & AC3 - 100 A complete all as specified and as directed.
(g) Bimetal ver load relay MN-5 type directly mounted/operated of range 30-50 Amp complete all as specified and as directed.
(h) Bimetal ver load relay MN-5 type directly mounted/operated of range 66-110 Amp complete all as specified and as directed.
(j) single phase preventer suitable for 3 HP to 50 HP pump sets complete all as specified and as directed.
S & F in replacement MCB TPN of capacity 40 Amp,3 phase, AC complete all as specified and as directed.
S & F in replacement MCB TP of capacity 63 Amp,3 phase, AC complete all as specified and as directed.
S & F in replacement MCB TP of capacity 100 Amp,3 phase, AC complete all as specified and as directed.
S & F in replacement FASD starter suitable for motor of capacity of 7.5 HP, 3 phase, AC, 415 Volt with single phase preventer Make- L&T or equivalent complete to be fixed in existing LT panel complete all as specified and as directed.
S & F in replacement FASD starter suitable for motor of capacity of 12.5 HP, 3 phase, AC, 415 Volt, complete with single phase preventer, Make- L&T or equivalent complete to be fixed in existing LT panel complete all as specified and as directed.
S & F in replacement FASD starter suitable for motor of capacity of 40 HP, 3 phase, AC, 415 Volt, complete with single phase preventer , Make- L&T or equivalent complete to be fixed in existing LT panel complete all as specified and as directed.
S & F in replacement FASD starter suitable for motor of capacity of 10 HP, 3 phase, AC, 415 Volt, complete with single phase preventer, Make- L&T or equivalent complete to be fixed in existing LT panel complete all as specified and as directed.
M & L for development of existing deep borewell to improve yield of the borewell by using compressed air blowing method & with 25% extra capacity pump by pumping of muddy water and lifting up water complete all as specified and as directed. Note:- (a) The quoted rates are inclusive oflifting/lowerging of the pump motor from bore well. (b) During lifting/lowering of pump motor from borewell if falls in the borewell then contractor will arrange to take out the pump motor without any extra cost.
Taking down the old deterioted/damaged rubber mats from the sub stations, supply & lay synthetic insulating rubber matsof size: 2m x 1mx 19 mm for up to 3.3 KV complete all as specified and as directed.
M&L for earthling complete with galvanised iron earth plate electrode of the size 600 mm x 600 mm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanised iron strip 32 x 6 mm by means of bolts ,nuts.chuck nuts and washers of galvanised iron or .steel watering pipe of 20 mm bore , galvanised iron medium grade of 40 mm bore galvanised iron light grade of earth wire protection including all excavation earth work in any type of soil ,PCC pit with RCC pit cover , charcoal,salt,funnel complete all as shown in electrical plate No-3 of SSR Part-I & Testing on completion complete all as specified and as directed. Note: Quoted rates shall be including for earth strip with protection pipe upto 7.5 mtr length.
M&L for rectification of defective run lead joing by burning out lead joint in position including recovering lead and making new lead joint all as specified including bailing out water coming from defective joints by means of electric/diesel driven pump set, testing of the joint under full working pressure for the following CI Pipe lines complete all as specified and as directed:-
(a) 200 /150mm dia.
(b) 100/80 mm dia.
M&L for rectification of defective rubber gasket flanged joints including replacing rubber gasket, bolts, nuts and washers for the following CI/MS pipe line complete all as specified and as directed:-
(a) 200/150 mm dia.
(b) 100/80 mm dia.
M & L for carrying sample testing of drinking water as per relevant IS of drinking water and submission of detailed test report to the office of the Engr-in-charge and testing in Govt approved laboratory as approved by GE. (a) Carrying out minimum essential testing of drinking water as per relevant IS mandatory for Colour,odour, Taste, Turbidity, PH value,TDS, Total Hardness, Chloride,Calcium, Magnesium, Fluoride, Sulphate, Alkalinity, Iron, Residual Chlorine and other characterstics as per relevant IS of drinking water. (i) Cost of sterilized bottle as required. (ii) cost of sample collection from Site to laboratory including transportation charges are included in the quoted rate.
Supply and fix in replacement MCCB 100 A ,3 pole ,25 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning complete all as specified and as directed.
Supply and fixing in replacement of MCCB 250 A, 4 pole, 36 KA with adjustable thermal magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning complete all as specified and as directed.
Supply and fix in replacement MCCB 160 A ,3 pole ,36 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning complete all as specified and as directed.
Supply and fixing GI Powder coated perforated type cable trays 18 SWG 100mm width 50mm height complete all as specified and as directed.
M/S PARKASH ENTERPRISES (BID ID -3136227)
D P ENTERPRISES (BID ID -3135260)
YASHVI ENGINEERS (BID ID -3142662)
M/S Rohit Enterprises (BID ID -3138243)
k k enterprises (BID ID -3136021)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .