GE (AF) Jaisalmer
GE (AF) Jaisalmer
REPAIR/MAINT OF LT DISTRIBUTION/LIGHTENING PROTECTION EARTHING, LEDs AND OTHER CONNECTED ITEMS AT WSA AND REPAIR OT FIRE FIGHTING SYSTEM AT SRE COMPLEX AT AF STATION JAISALMER
2022_MES_530510_1
8832/GE/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (AF) Jaisalmer
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Jaisalmer
₹70,000
Yes
1 Aug 2022
13 Jun 2022
23 Jul 2022
13 Jun 2022
21 Jul 2022
27 Jun 2022
14 Jun 2022 - 19 Jun 2022
Amount
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc. or for laying of cables, pipes, erection of poles, structs/stays etc. or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sqm on plan and getting out any type of soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified.
Removal of excavated soil/ material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified.
Stone patti 40 to 50mm thick rough dressed Jodhpur stone slab cover in trenches for protection of cable 25 to 35cm wide and not less than 80cm in length laid dry abutting each other with gap between adjacent slab not exceeding 10mm over sand cushioning complete all as specified and directed.
Dry tibba sand cushioning to underground cable provided with a layer of 8cm deep before laying cable and 15cm after laying of cable and punned to 18cm after laying of cable and cover for protection of underground cable complete all as specified and directed. Notes :- (i) Approved dry sand free from vegetation, grass and other deleterious substances shall be used. (ii) For the purpose of payment only punned thickness shall be measured for payment.
Plain cement concrete (1:4:8) Type D-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete for foundation of walls complete all as specified and directed.
Plain cement concrete (1:2:4) Type B-1 (using 20 mm graded stone aggregate) as in copping of poles including necessary form work and finished the surfaces complete all as specified and directed.
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one coat primer, one under coat and one finishing coat of synthetic enamel paint including disconnecting & taking down old unserviceable complete all as specified and directed.
Earthing complete with galvanished earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5 deep below normal ground level and connected to galvanished iron earth lead strip 32mmx6mm upto 7.50 metre, by means of GI nuts, bolt, check nuts, washers, thimbles, etc as shown in electrical plate No. 5 SSR Part-I and connection to main switch board or panel and testing on completion including excavation and earth work in any type to soil, returning fitting in and removal of surface spoil to a distance not exceeding 50 metre, PCC chamber (1:2:4) type B-1, charcoal and salt mixed layer 15cm thick all around the earth plate electrode, MS funnel with wire mesh, 20mm bore, Galvanised Iron pipe light grade, 1.50 metre long for watering and 40mm bore Galvanised Iron pipe light grade for earth lead protection 5.00 metre long fixed with poles with two clamps, made from earth lead strip 32mm x 6mm, bolts, nuts and washers, 80mm thick pre cast RCC cover 1:2:4, type B-1, reinforced with hard drawn steel wire fabric wieghing not less than 4 Kg/Sqm in lieu of CI cover etc including dismantling & taking out old unserviceable earthing complete all as specified & as directed. Note : (i) Excavation and earth work for drilling hole for electrode in any type of soil shall be included in this item. (ii) The unit rate shall be deemed to included for Test Point, 32mmx6mm GI strip from top of the earth plate upto 7.50m above ground level. In case, GI protection pipe required is less than 7.50m, no price adjustment shall be made. (iii) PCC Pit shall be provided at least 500mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junctions, elbow etc shall be deemed to be included in the unit rate quoted by the tenderer.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 35 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 25 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 16 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 10 sqmm 2 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old unserviceable cable complete all as specified and directed.
Galvanized steel water tubing light grade of 40mm bore with & including all fittings complete, laid in trenches or fixed to wall/pole with clamp of 25x3mm flat iron including taking up or down old unserviceable steel water tubing and connections of 40mm bore, complete all as specified and directed.
Polypropylene random copolymer concealed (PPR) Pipes, 3 Layer, UV stabilised having thermal stability upto 93 degree centrigrade complete and fixed with the pole by providing Flat Iron clamps, nuts and bolts of size 25x25x3mm with nuts & bolts for protection of connecting wires, connection from Junction box to light fittings complete for outer dia 20mm (PN-16), including taking up or down old unserviceable pipe and connections of 20mm bore, complete all as specified and directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4mm GI strip including taking down old unserviceable complete all as specified and directed. Note : Nut, bolt and other items included in quoted rate by the tenderer.)
PVC insulated and fire retardant PVC sheathed, copper conductor of round cable size 1.5 sqmm, 3 core for electric connection from feeder /looping box /street light over head line to street light fittings including taking out old unserviceable cable from pole all as specified and directed.
Boring Hole/Driling (Horizontally) under the road / pavement / hard standing with the help of trenchless and necessary machine for inserting Galvanised steel pipe of size 100/80mm not less than one metre below ground level complete all as specified and directed. Note : GI pipe shall be measured and paid for seperately in respective items.
Pre Stressed concrete Pole 9.00 mtr long, 102mm x 152mm at top and 102mm x 289mm at bottom, class 10 complying with requirements of IS-1678-1978 including painting of poles with two coats of synthetic enamel paint over a coat of primer with black and white strips 30cm wide each upto 1.5mtr height from top of PCC foundation block and numbering of poles, including disconnecting & taking down old unserviceable broken RCC Pole complete all as specified and directed. Note: (i) Excavation in trenches in any types of soil, returning filling in and well ramming including watering and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (ii) PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundation bedding complete all as specified and directed. (iii) PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate as upto ground level complete all as specified. (iv) PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in coping including necessary form work complete all as specified and directed. (v) Painting of Pole upto 1.5mtr of height from coping level with alternative strip black and sky blue of width not less than 0.30 mtr and writing pole Number with yellow shade on black base using synthetic enamel paint having height of words exceeding 5cm complete all as specified and directed. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
Preparation of RCC surfaces LT/HT electric poles and apply one coat of synthetic enamel paint upto 1.50 mtr length and making of pole number and five strips each 30cm wide in navy blue & white colour using synthetic enamel paint upto 1.50mtr height from top of RCC foundation block complete all as specified and directed.
Preparation of steel surfaces for steel tubular electric poles, rail pole, swan neck pole of HT/LT over head line and all mild steel clamps, cross arms work on poles with apply one coat of superior aluminium paint upto 1.50 mtr length and making of pole number and five alternate strips each 30cm wide with black and navy blue colour for LT Poles and black and red colour for HT Poles using painted upto 1.50mtr height from top of PCC foundation block complete all as specified and directed.
Disconnecting, dismantling of existing old unserviceable LT Panel/Feeder pillar box and Design, supply, erection, commissioning and testing of outdoor type LT Panel, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type main copper bus bars of 200 Amps, looping & branch connection system shall be made with suitable rating copper bus bar having sleeves of colour coded .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 9 tank pre-treatment of surfaces. The LT Panel shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The LT Panel shall be made out of 3.15mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (02 layers) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom. All incoming MCCBs shall be marked with location and rating of MCCBs. The Feeder Pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation in and including dismantling of old unserviceable LT Panel complere and including the followings : CONTROL WIRING: All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated multi-flexible type copper wire of cross sectional area 1.50 sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges. CABLE ALLEY: Cable alley shall be provided in both side of the panel of suitable space for all incoming and outgoing cables. Cable terminals shall be provided for conencting of all incoming and outgoing cables.
For serial item No. 22.00 (Contd...) INCOMING: (a) MCCB, 4 Pole, 160 Amps rating, rupturing capacity 25 kA, 415 volt grade, AC supply, 50 Hz, Electronic release protection unit - 01 Nos OUTGOING:(a) MCCB, 4 Pole, 40 Amps rating, rupturing capacity 16 kA, 415 volt grade, AC supply, 50 Hz, Thermal Magnetic protection unit - 04 Nos (b) Digital voltmeter 96x96mm suitable to read 0 to 500 volt accuracy class 1% - 01 Nos, (c) Digital ammeter 96x96mm suitable to read 0 to 630 volt accuracy class 1% - 01 Nos, (d) Current Tranformer (CT) of rating 630/5, tape wound, rated burden 5 VA - 03 Nos (e) LED indicator lamps complete with integral circuit and cluster LED, suitable to operate in 230-240 Volts AC supply - 1 set of 03 Nos ({RYB) (Red-01, Yellow-01, Blue-01)}.
For serial item No. 22.00 (Contd...) OUTGOING: (f) Control fuse holder, 16 Amps rating, stud type, panel door mounting complete with 01 No 02 Amps HRC fuse of suitable type - 03 Nos, (g) Copper bus bar 20mm wide, 5mm thick suitable length duly mounted on FRP bus bar insulators and marked with standard colour coded sleeves / tapes for all outgoing MCCBs - 04 Nos (h) LED Pilot Lamp of following colours:(i) Red-01No, Yellow-01No, Blue-01No. (j) Danger Notice Plate - 02 Nos (k) Power contactor Four Pole with coil voltage 230 volt of capacity 63 Amps, 50 cycles - 01 Nos (l) Time switch microrex analog time switch - 01 Nos (m) Panel box made up of CRCA mild steel 3.15mm thick, duly powder coated with bus bar and internal wiring all as per CPRI approved. Note : (i) The panel shall not be less than 1.5 sqm front area. (ii) Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panel to the Engineer-in-Charge before procurement of LT panel for approval alongwith CPRI approval. Foundation will prepared as per instructions of manufacturer and rate of foundation shall be deemed to be included in the quoted rates.
Disconnecting, dismantling & taking down existing old unserviceable LT Panel/Feeder Pillar box of any size and capacity with fixtures and Supply, installation, testing and commissioning of LT cubical panel board of outdoor type comprising of 3 phase, 4 wire, 415 volt AC supply and having 4 Nos stepped type main copper bus bar capacity 800 Amp, looping and branch connection system shall be made with suitable rating copper bus bar having sleeves of colour coded including multi functional digital meters to read voltage, current frequency, hooter and power factor, having individual compartment type made out of 3.15mm thick CRCA MS sheet and 3.00mm thick gland plate, front door (02 layers) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom. All incoming MCCBs shall be marked with location and rating of MCCBs. The Feeder Pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation in and including dismantling of old unserviceable LT Panel complere and including the followings : CONTROL WIRING: All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated multi-flexible type copper wire of cross sectional area 1.50 sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges. CABLE ALLEY: Cable alley shall be provided in both side of the panel of suitable space for all incoming and outgoing cables. Cable terminals shall be provided for conencting of all incoming and outgoing cables.
For serial item No. 23.00 (Contd...) INCOMING (a) MCCB, 4 Pole, 630 Amps rating, rupturing capacity 50 kA, 415 volt grade, AC supply, 50 Hz, Electronic release protection unit - 01 Nos OUTGOING (a) MCCB, 4 Pole, 250 Amps, rupturing capacity 36 kA, 415 volt grade, AC supply, 50 Hz, thermal Magnetic protection unit - 01 Nos (b) MCCB, 4 Pole, 200 Amps rating, rupturing capacity 25 kA, 415 volt grade, AC supply, 50 Hz, Thermal Magnetic protection unit - 01 Nos (c) MCCB, 4 Pole, 160 Amps rating, rupturing capacity 25 kA, 415 volt grade, AC supply, 50 Hz, Thermal Magnetic protection unit - 02 Nos (d) Digital voltmeter 96x96mm suitable to read 0 to 500 volt accuracy class 1% - 01 Nos, (e) Digital ammeter 96x96mm suitable to read 0 to 630 volt accuracy class 1% - 01 Nos, (f) Current Tranformer (CT) of rating 630/5, tape wound, rated burden 5 VA - 03 Nos (g) LED indicator lamps complete with integral circuit and cluster LED, suitable to operate in 230-240 Volts AC supply - 1 set of 03 Nos ({RYB) (Red-01, Yellow-01, Blue-01)}.
For serial item No. 23.00 (Contd...) OUTGOING : (h) Control fuse holder, 16 Amps rating, stud type, panel door mounting complete with 01 No 02 Amps HRC fuse of suitable type - 03 Nos, (j) Copper bus bar 20mm wide, 5mm thick suitable length duly mounted on FRP bus bar insulators and marked with standard colour coded sleeves / tapes for all outgoing MCCBs - 04 Nos (k) LED Pilot Lamp of following colours : (i) RED - 01 No, YELLOW - 01 No, BLUE - 01 No. (l) Danger Notice Plate - 02 Nos (m) Power contactor Four Pole with coil voltage 230 volt of capacity 25 Amps, 50 cycles - 01 Nos (n) Time switch microrex analog time switch - 01 Nos (o) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with bus bar and internal wiring all as per CPRI approved (The panel shall not be less than 2.0 sqm front area). Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panel to the Engineer-in-Charge before procurement of LT panel for approval alongwith CPRI approval. Foundation will prepared as per instructions of manufacturer and rate of foundation shall be deemed to be included in the quoted rates.
Dismantling of old unservicable bus bar chamber and Design, supply, erection, testing and commissioning of outdoor type LT Bus Bar Chamber box, platform mounted, suitable for 3 phase, 4 wire, 415 volts AC supply and having 4 Nos stepped type Aluminium bus bars (32mmx5mm) for looping and branch connection system, Bus bar chamber made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and angle iron frame of 40x40x6mm thick including mounting legs of same angle iron 50cm long embedded in PCC foundation 1:2:4 type B-1 using 20mm graded crushed stone aggregate complete and suitable neoprene rubber gasket to make its completely dust and vermin proof both side openable with locking arrangement, proper 4 side slanting canopy tye roof projection on top and having required cable entry glands of suitable size including stud type aluminium cable lugs for incoming and outgoing cables of suitable, front door (01 layer) and rear door (01 layer) opening facility. The bus bar chamber shall be provided with ventilation facility in the form of louvers for better heat dissipation. The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 7 tank pre-treatment of surfaces. The bus bar chamber shall be provided with suitable degree of protection not less than IP-55 and general construction conforming to IS : 13947 complete all as specified and directed. Note: The bus bar chamber Box shall be designed in such a way that adequate workable space is made available inside the compartments and the size of the chamber shall not be less than 500mm height (without base frame & canopy), 500mm width and 450mm depth).
Cable Junction box made out of polycarbonate with IP 55/IP 65 protection of size 200mm x 160mm x 98mm, 5 way having terminals for termination of cable with necessary nuts and bolts including 02 Nos polycarbonate cable gland, 01 Nos DIN rail for mounting of MCB and including MCB, Single Pole, rupturing capacity 10 kA, 6 Amps in and including fixing clamp of FI 50 x 6mm with necessary nuts and bolts complete including taking down old unserviceable junction box of any type complete all as specified and directed.
Supply installation, commissioning and testing of tripode ring earthing complete with CPRI tested 50mm dia copper cladded (250 micron) earth electrode 3000mm in length with NABL tested RoHS complaint earth enhancement compound 30 Kg in each bore hole in tripod configuration with copper strip of 25x3.15mm inter connected by means of exothermic brazing & protected by GI pipe light grade 32mm bore upto the test point i.e 7.50mtr in length and PCC 1:3:6 type C-1 earth chamber & earth pit cover 300x300mm connecting to test point & testing on ground complete including excavation, earth work, boring in any type of soil strata & cleaning of site including taking down old unserviceable earth complete all as specified and directed. Make: JMV earthing/Daksh Power Solutions/Ashlok Note: (i) Copper strip of size 20x3.15mm required to connected to the electrode upto test point is deemed to be included in quoted rate by the tenderer. (ii) The boring will take place for 3mtr depth & 350mm dia. Earth enhancement compound to be filled around the earth electrode in 100mm dia in 3 layers of 1mtr each by means of PVC pipe of 100mm dia as casing/form work. The ramaning valume of bore shall be filled with clay soil (available from vicinity) in 3 layers of 1mtr each. The PVC pipe to be removed simultaneously. The cost of all this is deemed to be included in the quoted rates. (iii) Cost of excavation, earth work, boring, PCC earth pit, CI cover including testing & commissioning etc is deemed to be included in the quoted rates by the tenderers. (iv) Marking & painting of earth pit with iron, plate of suitable size is deemed to be included in the quoted rates. (v) Minimum distance between each earthing is not less than 3 RM. (vi) Testing of earthing shall be conducted and result should be less than 1.00 Ohm.
Energy efficient LED street light fittings of 60 Watt, pressure die cast alluminium housing & toughened glass with IP-66 degree of protection, individuals LED's should have lenses for better throw across & along road range 140-280 volts fittings should be provided 5 KV surge protection external and apart from this surge, arrestor driver should have additional 4 KV surge protector in built in driver for maximised protections, should have lumens output of 100 lumens watt minium protections facility in drivers, driver should be potted type for viberation proof performance & includings making electrical connections including taking down old unserviceable complete all as directed and directed. Note :- Driver should be BIS registered with "R" marking.
Single pointed air termination copper rod 12mm dia and 300mm long fixed with necessary fixing arrangement including taking down old unserviceable complete all as directed and directed.
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3 Nos, 8mm dia, 25mm long hexagonal head screw including taking down old unserviceable complete all as specified and directed.
Copper strip 20x3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground level including taking down old unserviceable complete all as specified and directed.
Porcelain insulator suitable for fixing earthing strip to the wall/floor etc including taking down old unserviceable complete all as specified and directed.
Supply (in company sealed cylinders of any capacity) and charging refrigerant gas R-22 for filling in compressors as per requirement complete all as specified and directed. Note : If the recharged refrigerant gas is leaked within 45 days of running of AC plant, the contractor shall recharge gas (including supply) without any extra cost to the department.
Supply (in company sealed cylinders of any capacity) and charging refrigerant gas R-407 c for filling in compressors as per requirement complete all as specified and directed. Note : If the recharged refrigerant gas is leaked within 45 days of running of AC plant, the contractor shall recharge gas (including supply) without any extra cost to the department.
Fan Belt for AHU of size A-28/29/30 or any other size as per existing fixed as in repairs complete all as specified and directed.
Drier filter suitable for ductable Central AC plant/package type Air Conditioner Plant of capacity 17 TR to 22 TR and fixed as in repair complete all as specified and directed. Make: Danfoss/ indofoss complete all as specified and directed.
Expanion Valve for Chillar Plant as per existing size and fixed as in repair complete all as specified and directed.
Bearing Shaft as per existing size and fixed as in repair complete all as specified and directed.
Finding out the leakage and pressure test with filling N2 gas inside of the condensor and cooling coil of Chiller Package Air Conditioning Plant capacity 17 TR to 22 TR including dismantling the same for repair the leakage point by brazing /soldering including taking down and refixing the unit and testing the AC unit complete all as specified and directed.
Supply, installation, commissioning and testing Compressor scroll type Copper wound working on R-22, capacity 5.5 TR and compressor shall be equipped with sunction and discharge stop valves, sunctions, strainer, oil pump with oil strainer, high pressures switch and safety valves and gauges oil measuring the sunction and discharge pressure and the coil pressure shall be provied. Compressor shall be provided with unloading starting device and crank case heater system shall be provided including taking down old unserviceable compressor complete all as specified and directed. Make : Copeland Scroll Model Number ZR72KC-TFD-522, Serial No. 03B0903AT or equivalnet of Kirloskar/ELG.
Supply, installation, commissioning and testing of Compressor scroll type Copper wound working on R-407c, Capacity 8.75 TR and compressor shall be equipped with sunction and discharge stop valves, sunctions, strainer, oil pump with oil strainer, high pressures switch and safety valves and gauges oil measuring the sunction and discharge pressure and the coil pressure shall be provied.Compressor shall be provided with unloading starting device and crank case heater system shall be provided including taking down old unserviceable compressor complete all as specified and directed. Make : Danfoss Model Number HCP109T4LC6 or equivalent.
High pressure/ low pressure (HP/LP) cut out MP-5 complete all as specified and directed. Make : Indfoss/Danfoss as per existing
P No 205 (set of two) for AC blowers including turning the shaft as per reqirement at site complete all as specified and directed.
Induction Blower Motor capacity 2.0 PH, Three Phase, 415 Volt grade, 50 Hz, AC supply, 1400 RPM, (As per Sample) and fixed as in repair complete all as specified and directed. Make : CG/Kiroskar/Hindusthan
Power Contactor capacity 40 Amp, 3 Pole, 415 Volt, 50 Hz, type MNX, conforming IS/IEC 60947-4-1 complete with all accessories including disconnecting & taking down old existing unserviceable contactor complete all as specified and directed.
Power Contactor capacity 32 Amp, 3 Pole, 415 Volt, 50 Hz, type MNX, conforming IS/IEC 60947-4-1 complete with all accessories including disconnecting & taking down old existing unserviceable contactor complete all as specified and directed.
Condenser PVC fan Blade 24" fixed as in repair complete all as specified and directed.
Repair/maint and servicing of condensor fan motor for outdoor unit i/c ball bearing, studs, nuts, bolts, washers, gland packing, greasing etc as required complete all as specified and directed.
Canvas from pakage unit to inlet duct including accessaries and fixed as in repair in return grill with accessaries complete all as specified and directed.
PLC controller for 33 TR chillar unit fixed as in repair complete all as specified and directed. Make : Softhard automation model No-33 TR/ HMI (5-30A) /Ser No-02/2K13-50 or equivalent.
MPD of current range 5-30 Amp, Aux supply 0-11 VAC, 0-13 VAC Volt, 5 sec curve MPD fixed as in repair complete all as specified and directed. Make : Softhard automation Model - SCR 33 TR (MPD) or equivalent.
Complete control panel suitable for Package type AC plant of capacity 22 TR (11 TR working and 11 TR standby) make : Voltas (Comprising of two compressors of capacity 5.5 TR Each unit) including all accessories like incomming MCB TPN of minimium capacity 40 Amp, seperate contactors of suitable size for each compressor, blower motor and outdoor unit including complete wiring and connecting to the existing system complete all as specified and directed.
Complete evaporative coil suitable for 11 TR (2x5.5 TR compressor) package type AC with R-22 refrigerant complete including necessary brazing and connection with existing system complete all as specified and directed.
Dismantling of existing Cylinder bank from site at AF Station Jaisalmer/ re-installation, disconnecting of all electrical connections, testing of all components, servicing of all cylinder valve, local conveyance, loding and boarding complete all as specified and directed. Note : One Job consisting of 06 Nos of Cylinders.
Mounting of Cylinder valve protection cap complete all as specified and directed.
Cylinder pressure gauge fixed as in repair complete all as specified and directed.
Refilling of cylinders with FM-200 + Nitrogen to the set pressure complete all as specified and directed.
Supply and filling of HFC gas, FM-200 in all cylinders with N2 at site complete all as specified and directed.
Transportation of 06 Nos of cylinders from Jaisalmer to Vasi works site and back to Jaisalmer complete all as specified and directed.
SANJOLI CONSTRUCTION COMPANY
M/s Ramesh & Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .